Digital Fiber Optic & Laser Optic Sensor Guide E32 Series Fiber Units E3X-DAC-S True Color Series Amplifier Units E3X-DA-S/-MDA Series E3X-NA/-SD Series Offering unsurpassed sensing solutions General purpose, standard detection requirements Special beam, non-standard requirements Application specific requirements CONTENTS Fiber Unit Overview Standard Models Flexible (New Standard).................................................................................................................. Standard......................................................................................................................................... Break-resistant................................................................................................................................ Fluorine Coated.............................................................................................................................. 4 4 4 5 Special-beam Models Long Distance, High Power............................................................................................................. Ultracompact, Ultrafine Sleeve........................................................................................................ Coaxial, Small Spot........................................................................................................................ Fine Beam (narrow Vision Field)..................................................................................................... Area Sensing................................................................................................................................... Retroreflective................................................................................................................................. Limited-reflective............................................................................................................................ 8 8 9 10 10 11 11 Environmental-resistive Models Heat-resistant.................................................................................................................................. 12 Chemical-resistant.......................................................................................................................... 12 Vacuum-resistant............................................................................................................................ 13 Application-specific Models Label Detection............................................................................................................................... Liquid-level Detection..................................................................................................................... Glass-substrate Alignment.............................................................................................................. Glass-substrate Mapping................................................................................................................ Water Mapping............................................................................................................................... True Color Detection....................................................................................................................... 14 14 15 15 16 16 Ordering Information Through-beam Fiber Units.............................................................................................................. Fiber Units with Reflective Sensors................................................................................................. Application-specific Fiber Units...................................................................................................... Through-beam Fiber Units used with E3X-DAC True Color Detection............................................. Fiber Units with Reflective Sensors used with E3X-DAC True Color Detection................................ Accessories..................................................................................................................................... 18 29 38 41 43 45 Ratings/Characteristics..................................................................................................................................................................................................... 49 Dimensions Through-beam Fiber Units.............................................................................................................. Fiber Units with Reflective Sensors................................................................................................. Application-specific Fiber Units...................................................................................................... Accessories..................................................................................................................................... 51 58 65 68 Precautions....................................................................................................................................................................................................................... 70 Amplifier Overview Ordering Information/Ratings/Characteristics E3X-SD Simple Fiber Optic Amplifiers with Digital Display............................................................ E3X-NA Simple Fiber Optic Amplifiers with Bar Graph Display....................................................... E3X-DA-S Dual Display Digital Fiber Optic Amplifiers.................................................................... E3X-MDA Two-channel Dual Display Digital Fiber Optic Amplifiers............................................... E3X-DAC-S True Color Fiber Optic Amplifiers with Digital Dual Display........................................ 73 73 75 77 79 Laser Optic Unit Overview Sensing Heads.................................................................................................................................................................................................................. 81 E3C-LDA Dual Display Laser Optics Amplifiers................................................................................................................................................................ 81 Ratings/Characteristics..................................................................................................................................................................................................... 83 Accessories...................................................................................................................................................................................................................... 85 Dimensions...................................................................................................................................................................................................................... 85 Accessories Accessories...................................................................................................................................................................................................................... 86 Dimensions Dimensions...................................................................................................................................................................................................................... 90 Index................................................................................................................................................................................................................................. 98 Fiber Unit Standard Models Solutions for General-Purpose Applications These Fibers Units can be used in a variety of applications, such as detecting the presence of workpieces and positioning. A Wide Variety of Shapes for Adapting to Different Installation Locations Choose the model that suits the installation space from a wide variety of shapes and sizes (7 shapes, in standard or small sizes). Space Savings and Simple Mounting Flat Models Flat models that allow simple screw mounting and straightforward wiring have been added to the lineup. Using these models eliminates the problem of fibers getting caught on surrounding objects. Screw-shaped Flat Cylindrical Detect Workpieces in Tight Spaces Custom-produced Sleeves Models with sleeves allow detection in tight spaces. We will perform the timeconsuming task of fashioning the sleeve, with a length and bends to suit the space (except for ultrafine sleeves). Flat model Bendable SUS304 sleeves Equipped with sleeve Flexible, Pliable Fiber That Can Be Handled Like Wire We have developed a broad range of fibers to meet a wide variety of needs. Multicore (flexible) fiber is a new type of standard fiber that can be used like wire without worrying about the bending radius. We have also produced fiber that will not break when used in moving parts and fiber that is not degraded by contact with oil. Cut to Length in the Field Omron's fibers marked with this symbol let you customize the length and eliminate excess fiber for a tidy, safe installation. Length Can Be Specified in 1-m Units Saving Energy and Work We will produce fiber of the required length (in meter units). For large-scale installations, specifications of up to 20 m can be handled. (Specifications of 0.3 m and 0.5 m are also possible.) Conventional fiber Flexible fiber You will certainly appreciate the ease of use that flexible fiber ensures. 2 Special-beam Models Detection with Increased Reliability A variety of heads incorporating the latest optical technology makes it possible to solve common problems related to detection and to increase reliability. * Resistant to dust and dirt * Capable of detecting small workpieces * Resistant to workpiece vibration Use these models to handle unstable detection conditions. Small-spot models E32-C42+ E39-F3A Area-sensing models E32-T16J Limited-reflective models E32-L24L Area-sensing models E32-T16J Environment-resistive Models High Resistance to External Conditions with Fiber We have developed model variations for adapting to a variety of environmental conditions. These models enable detection in high-temperature environments and vacuums. * High-temperature environments Heat-resistant models * Environments subject to the splattering of chemicals * Vacuums Use these models to handle applications in special environments. Chemical-resistant models Application-specific Models Fiber Units for the Food-packaging, Semiconductor, and Solar Industries These models, which were developed for specific applications, offer top-quality detection performance. * Label detection * Liquid-level detection * Alignment and mapping of glass substrates * Wafer mapping * True color detection * Distance measurement Use these models for specific applications. Label-detection models E32-G14 Alignment-check models E32-L16 Liquid-level detection models E32-D36T 3 Features/Applications Standard Models Flexible (New Standard) R : Flexible fiber * P erform wiring without worrying about the bending radius. * Choose the model to suit the installation space from a variety of shapes. Flexible fiber Feature: Multicore (Flexible) Fibers Cores Conventional fiber Cladding A large number of ultrafine cores are all surrounded by cladding. As a result, the fiber is flexible and can be bent without significantly reducing the light intensity. This helps solve problems, such as fiber being broken by getting caught on other objects. Ratings/Characteristics Fewer problems Light intensity affected by bends in fiber Fiber broken by getting caught on surrounding objects Min. sensing object 0.005-mm dia. Min. bending radius 1 mm Ambient temperature -40C to 70C (no icing or condensation) Fiber material Plastic Standard * C hoose the model to suit the installation space from a variety of shapes. * New flat models allow space savings and simple installation. Feature: Flat Models Flat models, which allow simple attachment and wiring, have been added to the lineup. Choose the model to suit the installation space from 3 sensing directions and 2 sizes, standard and small. Ratings/Characteristics Right-angle Screw-shaped Screw-shaped Cylindrical Flat Min. sensing object 0.005-mm dia. Min. bending radius 10 or 25 mm* Ambient temperature -40C to 70C (no icing or condensation) Fiber material Plastic Equipped with sleeve * Depends on the fiber diameter. Break-resistant B : Bendable fiber * B undle-fiber models can be used for moving parts. * Capable of withstanding at least one million repeated bends (in typical applications). Feature: Bundle Fibers The Fiber Units contain a large number of independent fine fibers, ensuring a high degree of flexibility. Ratings/Characteristics 4 Min. sensing object 0.005-mm dia. Min. bending radius 4 mm (withstands repeated bending) Ambient temperature -40C to 70C (no icing or condensation) Fiber material Plastic Standard Models Fluorine Coating U : Fluorine-coated fiber Feature: Fluorine Coating * F iber degradation due to oil is prevented using a fluororesin coating. * Free cutting is possible with cutter provided. (Cross section) Fluororesin coating Oil is blocked! Fluororesin is used as the sheath material to prevent fiber degradation resulting from oil adhesion. Note: The tip of the head is not chemical-resistant. Ratings/Characteristics Min. sensing object 0.005-mm dia. Min. bending radius 4 mm Ambient temperature -40C to 70C (no icing or condensation) Fiber material Plastic Fiber Customization Service (Fiber Length, Sleeve Length, and Bends) Fiber Length Applicable Models Standard models Model Number Used for Ordering Standard model number + Fiber length Fiber length: 0.3 m, 0.5 m, or any length from 1 to 20 m (in 1-m units) Sleeve Length and Bends This customization/delivery service applies to standard models. It is aimed at reducing industrial waste and simplifying the installation procedure. Model Number Used When Changing the Sleeve Length and Bends Total length Total length L1 L2 R R Through-beam Fiber Units E32-TC200B/E32-TC200F (Fiber length of 2 m corresponds to 100%.) Fiber Units with Reflective Sensors E32-DC200B/E32-DC200F (Fiber length of 2 m corresponds to 100%.) Sensing distance (%) Sensing distance (%) Fiber Length vs. Sensing Distance 100 80 60 Model Numbers Incorporating the Bending Radius, R, and Dimensions L1 and L2 Specifying L1 Only Bending Radius L1 (1) 10 E32- *1 C200 *2 -S *3 A1 15 E32- *1 C200 *2 -S *3 A2 R5 100 80 12.5 E32- *1 C200 *2 -S *3 B1 17.5 E32- *1 C200 *2 -S *3 B2 R7.5 60 40 40 20 20 15 E32- *1 C200 *2 -S *3 C1 20 E32- *1 C200 *2 -S *3 C2 17.5 E32- *1 C200 *2 -S *3 D1 22.5 E32- *1 C200 *2 -S *3 D2 R10 R12.5 0 2 5 10 15 20 0 2 5 Fiber length (m) 10 15 20 (Units: mm) Model number Fiber length (m) Model Number Used When Changing Only the Sleeve Length L Model: E32-*1C200*2-S*3 *1: Insert "T" for Through-beam Fiber Units and "D" for Fiber Units with Reflective Sensors. *2: Insert the "B" or "F" that appears at the end of the original model number. *3: Insert "50" if the total length is 50 mm. The total length must not exceed 120 mm. Specifying L2 Only Bending Radius L2 (1) (Units: mm) Model number 5 E32- *1 C200 *2 -S *3 A3 10 E32- *1 C200 *2 -S *3 A4 7.5 E32- *1 C200 *2 -S *3 B3 17.5 E32- *1 C200 *2 -S *3 B4 R5 R7.5 10 E32- *1 C200 *2 -S *3 C3 20 E32- *1 C200 *2 -S *3 C4 12.5 E32- *1 C200 *2 -S *3 D3 22.5 E32- *1 C200 *2 -S *3 D4 R10 R12.5 5 Features/Applications Sensing distance (mm) (See note 1.) Standard Models Overview of Model Variations Model Through-beam Fiber Units Type (See note 2.) Flexible (New Standard) Standard Break-resistant B R Fluorine coating U (Cross section) Fluororesin coating Shape of head Screwshaped Flexible and pliable M4 530 E32-T11R (top-view) E32-TC200 E32-T21R M4 (1.2-dia. sleeve) Cylindrical (top-view) E32-TC200BR E32-TC200F E32-T12R 130 3 dia. E32-T24 E32-T15XR E32-T15X E32-T25XR 130 E32-T25Y 210 E32-T15ZR 460 E32-T15Z 50 12 x 7 x 2 E32-T25ZR M4 E32-T25XB E32-T15Y E32-T25YR 15 x 8 x 3 150 460 50 12 x 7 x 2 Right Angle 220 210 15 x 8 x 3 680 E32-T15XB E32-T25X E32-T15YR (side-view) 760 130 12 x 7 x 2 (flat-view) 130 530 15 x 8 x 3 E32-T22B 460 50 (top-view) 200 E32-T14L E32-T24R (side-view) 220 210 1 dia. 680 E32-T12B E32-T222 E32-T14LR Flat 760 E32-T12 E32-T22R (side-view) E32-T21 220 530 1.5 dia. 200 E32-TC200B E32-TC200FR 130 E32-T25Z 350 E32-T11N Note 1. The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode). 6 680 E32-T11U 760 130 3 dia. E32-T11 E32-TC200E Cable protected against oil 680 220 530 M3 (0.9-dia. sleeve) 760 130 M3 (with sleeve) Withstands repeated bending Sensing distance (mm) (See note 1.) Standard Models Overview of Model Variations Model Fiber Units with Reflective Sensors Type (See note 2.) Flexible (New Standard) Standard Break-resistant B R Fluorine coating U (Cross section) Fluororesin coating Shape of head Screwshaped Flexible and pliable M6 170 E32-D11R (top-view) E32-DC200 E32-D21R M4 (2.5-dia. sleeve) Cylindrical (top-view) E32-DC200BR (side-view) E32-DC200FR 30 20 E32-D25Y 40 E32-D15ZR 100 E32-D15Z 8 E32-D25ZR M6 E32-D25XB 100 8 12 x 8 x 2 50 E32-D15Y E32-D25YR Right Angle 80 40 15 x 10 x 3 170 E32-D15XB E32-D25X E32-D15YR (side-view) 300 E32-D15X E32-D25X (flat-view) 30 E32-D24 E32-D15XR 12 x 8 x 2 E32-D22B E32-D14L 170 15 x 10 x 3 30 110 15 12 x 7 x 2 (side-view) 80 45 E32-D24R Flat 70 E32-D221B E32-D22 E32-D14LR (top-view) 230 E32-D12 E32-D22R 15 x 10 x 3 E32-D21 E32-DC200F 30 2 dia. 30 80 170 6 dia. E32-D11U E32-DC200B E32-D12R 3 dia. (1.5 dia.) 170 300 30 3 dia. E32-D11 E32-DC200E Cable protected against oil 170 80 170 M3 (1.2-dia. sleeve) 300 30 M3 (with sleeve) Withstands repeated bending 20 E32-D25Z 170 E32-D11N Note 1. The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode). 7 Features/Applications Special-beam Models Long Distance, High Power * P owerful beam reduces influence of dust and dirt. * Long sensing distance enables use in large-scale installations. Applications Detecting parts inside (translucent) containers Detecting workpieces in coating processes E32-T11L E32-T17L Ratings/Characteristics E32-T14 Ambient temperature -40C to 70C (no icing or condensation) Fiber material Plastic Overview of Model Variations Type Features Shape, sensing distance (mm)* Equipped with large lens Through-beam Reflective Model number 20,000 E32-T17L Side-view, screw mounting 3,400 E32-T14 M4 screw 1,330 E32-T11L Equipped with large lens 700 E32-D16 M6 screw 400 E32-D11L Ultracompact, Ultrafine Sleeve * U ltracompact head can be installed in tight spaces. * Ultrafine sleeve ensures reliable detection of small objects, such as electronic components. Applications Alignment inspections Detection of terminals E32-D33 E32-T33-S5 1 dia. 3 dia. E32-T223R 0.22 dia. E32-T334-S5 3 dia. 0.5 dia. E32-D33 Ratings/Characteristics Min. sensing object 0.005-mm dia. Ambient temperature -40C to 70C (no icing or condensation) Material Plastic Overview of Model Variations Type Features Shape, sensing distance (mm)* 1-dia. cylinder Through-beam 0.5-dia. sleeve (0.25-dia. opening) 0.22-dia. sleeve (0.1-dia. opening) Reflective 130 E32-T223R 44 E32-T33-S5 5 E32-T334-S5 0.8-dia. sleeve 16 E32-D33 0.5-dia. sleeve 3 E32-D331 *The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode). 8 Model number Special-beam Models Coaxial, Small Spot Applications * S mall spot diameter (0.1 mm min. in diameter) enables the reliable detection of small workpieces. * Use of red light ensures easy visual recognition and simple positioning. Detecting of CDs E32-C31+ E39-F3C Ratings/Characteristics E32-C42+ E39-F3A Min. sensing object 0.005-mm dia. Ambient temperature -40C to 70C (no icing or condensation) Fiber material Plastic Overview of Model Variations Type Coaxial, reflective Features Shape, sensing distance (mm)* Model number Coaxial, M6 screw 300 E32-CC200 Coaxial, 3-dia. cylinder 150 E32-D32L E32-C41+ E39-F3A-5 Small spot 0.1-dia. spot at a distance of 7 mm Small variable spot Spot diameter variable in the range E32-C42+ 0.1 to 0.6 mm at distances in the E39-F3A range 6 to 15 mm Long distance, small spot 0.5-dia. spot at 17 mm E32-C31+ E39-F3B Long distance, parallel light Spot diameter of 4 mm max. at distances in the range 0 to 20 mm E32-C31+ E39-F3C 11 mm 7 mm 6 mm 15 mm E32-C41+ E39-F3A-5 20 mm 17 mm 0.1 mm dia. spot Variable from 0.1 to 0.6 dia. E32-C4+ E39-F3A 0.5 mm dia. E32-C31+ E39-F3B 4 mm dia. E32-C31+ E39-F3C *The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode). 9 Features/Applications Special-beam Models Fine Beam (Narrow Vision Field) * F ine beam reduces unwanted light in surrounding area. * Powerful beam allows use in applications requiring a long sensing distance. Approx. 60 Applications Alignment inspection of orientation flats Approx. 6 E32-T22S Ratings/Characteristics 1300 mm E32-T24S Min. bending radius 10 mm Ambient temperature -40C to 70C (no icing or condensation) Fiber material Plastic Overview of Model Variations Type Through-beam Features Shape, sensing distance (mm)* Model number Top-view 1,900 E32-T22S Side-view 1,300 E32-T24S Area Sensing * T hese Fiber Units ensure greater reliability with the detection of position inconsistencies in passing workpieces and the presence of workpieces with holes. * Wide sensing bands of 11 and 30 mm (throughbeam models) enable the detection of large position inconsistencies. Applications Detecting passage of candies Detecting chips on film E32-T16WR E32-T16R 11 mm Ratings/Characteristics 30 mm E32-T16WR E32-D36P1 Ambient temperature -40C to 70C (no icing or condensation) E32-T16W only: -25C to 55C Fiber material Plastic Overview of Model Variations Type Through-beam Reflective Features Shape, sensing distance (mm)* Sensing width: 11 mm 840 E32-T16PR Sensing width: 11 mm Flat-view 750 E32-T16JR Sensing width: 30 mm 1,300 Beam width: 11 mm *The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode). 10 Model number 150 E32-T16WR E32-D36P1 Special-beam Models Retroreflective * T he return optical path ensures that more light is interrupted by transparent workpieces than with through-beam models. * Equipped with MSR function to eliminate light reflection. Applications Detecting translucent medicine E32-R21 Ratings/Characteristics E32-R16 Ambient temperature E32-R21: -40C to 70C E32-R16: -25C to 55C (no icing or condensation) Fiber material Plastic Overview of Model Variations Type Features Shape, sensing distance (mm)* MSR function, M6 screw Retroreflective MSR function, screw mounting, long distance Model number 250 E32-R21 1,500 E32-R16 Limited-reflective * L imited-reflective models eliminate light reflected from distant objects. * Small level differences can be reliably detected. * The optical-axis direction can be selected according to the installation space. Applications Detecting connector pins Detecting wafers (glass substrates) E32-L25L Non-detection range E32-L24L Ratings/Characteristics Detection range E32-L24L Min. sensing object 0.005-mm dia. Fiber material Plastic 200C models only: Glass Overview of Model Variations Type Features Shape, sensing distance (mm)* Ultracompact, flat-view Ideal for checking stocks of glass substrates Limitedreflective Heat-resistant up to 105C, top-view Model number 0 to 4 E32-L24S 5.4 to 9 (center: 7.2) E32-L25L Wide sensing range flat-view 0 to 15 E32-L16 Heat-resistant up to 200C, flat-view 4 to 10 E32-L86 *The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode). 11 Features/Applications Environment-resistive Models Heat-resistant Applications * T hese Fiber Units can be used for various applications in temperatures up to 400C. Detecting wafers in high-temperature environments E32-T61-S Ratings/Characteristics 200C and higher models Min. bending radius E32-T84S-S Fiber material 150C models E32-T81R E32-D81R 35 mm 10 mm 25 mm Plastic (fluororesin coating) Glass (fluoroesin coating) Glass (SUS spiral coating) All other models Overview of Model Variations Type Through-beam Reflective Ambient Temperature Features Shape, sensing distance (mm)* 760 Model number E32-T51 -40C to 150C M4 screw -40C to 200C L-shaped, long distance -60C to 350C M4 screw 450 E32-T61-S -60C to 350C M6 screw 90 E32-D61-S -40C to 400C M6 screw, with sleeve 60 E32-D73-S 1,300 E32-T84S-S Chemical-resistant * B uilt-in lens and high-power beam reduce the influence of dirt and drops of water. * Round design prevents drops of water sticking to the head (E32-T11F). Applications Detecting workpieces in cleaning processes E32-T12F Ratings/Characteristics All other models Ambient temperature -40C to 70C E32-T14F Fiber material E32-T51F E32-T81F-S -40C to 150C -40C to 200C Glass (fluororesin coating) Plastic (fluororesin coating) Overview of Model Variations Type Features Shape, sensing distance (mm)* Water-resistant round head 2,000 E32-T11F Through-beam Built-in lens, high power 3,000 E32-T12F Reflective Built-in lens, high power Heat-resistant up to 200C *The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode). 12 Model number 700 95 E32-T81F-S E32-D12F Environment-resistive Models Vacuum-resistant Applications (Configuration Example) * T hese models can be used in high-vacuum environments at pressures from 10-5 to 0.1 Pa. * The 4-channel multi-flange, which has a maximum leakage rate of 1x10-10 Pa*m3/s, contributes to space savings. Lens Unit E39-F1V Vacuum chamber Vacuum side Atmospheric-pressure side Fiber Unit on vacuum side (set of 2) Flange E32-T51V E32-VF4 (4ch) E32-T54V E32-VF1 (1ch) E32-T84SV Fiber Units on atmosphericpressure side (set of 2) E32-T10V Amplifier Unit E3X-DA-S E3X-NA Ratings/Characteristics 120C models 200C models Min. bending radius 30 mm 25 mm Fiber material Glass (fluororesin coating) Glass (SUS spiral coating) Atmosphericpressure side Plastic (fluororesin coating) Overview of Model Variations Type Features Shape, sensing distance (mm)* M4 screw, top-view, heat-resistant up to 120C, long distance Through-beam 1,000 Model number E32-T51V 1M+ E39-F1V L-shaped, heat-resistant up to 120C 130 E32-T54V 1M L-shaped, long distance, heat-resistant up to 200C 480 E32-T84SV 1M Fiber Units on Atmospheric-pressure Side Appearance Type Common Model number E32-T10V 2M Flanges Appearance Type Model number 4-channel flange E32-VF4 1-channel flange E32-VF1 Ratings/Characteristics Number of channels Item Model number 4 channels 1 channel E32-VF4 E32-VF1 Pa*m /s max. Leakage rate 1x10 Ambient temperature Operating: -25C to 55C Storage: -25C to 55C Material Aluminum (A5056) Flange-seal material Fluorocarbon rubber (Viton) Weight (packed state) Approx. 280 g -10 3 Stainless steel (SUS304) Aluminum (A5056) Approx. 240 g *The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode). 13 Features/Applications Application-specific Models Label Detection * B uilt-in lens and high-power beam enable the reliable detection of labels through a mounting board. * These Fiber Units can be washed with hydrogen peroxide, making them ideal for the food industry. Applications Detecting labels E32-G14 Ratings/Characteristics E32-G14 10 mm Ambient temperature -40C to 70C (no icing or condensation) Fiber material Plastic Degree of protection IP67 Overview of Model Variations Type Features Shape, sensing distance (mm)* Slot sensor, no adjustment of optical axis required Model number 10 E32-G14 3,400 E32-T14 Through-beam Screw mounting, side-view Liquid-level Detection * A rea sensing is possible with minimal influence from bubbles and drops of water (E32-A01/A02/D36T). * For safety when disconnections occur, two models have been developed, a light ON model for liquid presence and a light ON model for liquid absence (E32-A01/ A02). Tube-mounting model Liquid-contact model Operating Principle Tube-mounting Liquid-contact model Tube Liquid Air Air Liquid No liquid present E32-D36T E32-D82F1 Liquid present The presence/absence of liquid is detected using the refractive properties of light. More specifically, it utilizes the fact that the difference in refractive index between the air and the tip/tube is larger than the difference between the liquid and the tip/tube. Overview of Model Variations Type Through-beam Liquid-contact Features Shape, sensing distance (mm)* Light ON when liquid is present (ideal for checking lower limits) E32-A01 Light ON when liquid is absent (ideal for checking for overflow) Applicable tube: Transparent tube with a diameter in the range 6 to 13 mm and a recommended wall thickness of 1 mm E32-A02 No restriction on tube diameter, resistant to bubbles and drops of water Applicable tube: Transparent tube (no restriction on diameter) E32-D36T Heat-resistant up to 200C, shape prevents liquid buildup Liquid-contact model E32-D82F1 *The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode). 14 Model number Applicable tube: Transparent tube with a diameter of 3.2, 6.4, or 9.5 mm and a recommended wall thickness of 1 mm Application-specific Models Glass-substrate Alignment Engineering Data (E32-A07/A08/L16) Detection-Position Characteristics (Typical Examples) Sensing object: Raw glass (t = 0.7 mm, rounded edge) E32-A07 25 Sensing distance, Y (mm) * T here is little variation of detection position within the detection range (0.1 mm max.) * The different model variations can handle a variety of sensing distances and temperature conditions. E32-L16 X Y 20 E32-L16 15 10 E32-A08 5 0 2.5 3.0 3.5 4.5 5.5 6.0 Detection position, X (mm) Overview of Model Variations Type Features Shape, sensing distance (mm)* 0 to 15 mm, wide-range sensing Limitedreflective Long-distance sensing Heat-resistant up to 300C Model number 0 to 15 E32-L16 10 to 20 E32-A08 15 to 25 E32-A07E1 E32-A07E2 5 to 18 E32-L66 Glass-substrate Mapping Engineering Data (E32-A09) Digital Light-intensity Value vs Sensing Distance (Typical Examples) Angle Characteristics in Left and Right Directions (Typical Examples) Rate of change of digital light-intensity value (%) 300 Digital light-intensity value * T hese models can reliably detect thin glasssubstrate end faces (t = 0.5 mm, beveled edge). * Using a large-diameter lens makes it possible to cope with tilting of the glass substrates. 250 Beveled edge 200 Rounded edge 150 100 50 0 100 75 50 25 0 0 10 20 30 40 50 60 70 -10 Sensing distance, X (mm) Sensing object: Raw glass (t = 0.5 mm, beveled/rounded edge) X mm E32-A09 -8 -6 -4 -2 0 2 Angle, ( ) 4 6 8 10 Sensing object: Raw glass (t = 0.5 mm, rounded edge) 25 mm + Emission side - Reception side Overview of Model Variations Type Limitedreflective Features Large-diameter lens ensures resistance to tilting Shape, sensing distance (mm)* 15 to 38 (center: 25) Heat-resistant up to 150C Heat-resistant up to 300C Model number E32-A09 E32-A09H 20 to 30 (center: 25) E32-A09H2 *The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode). 15 Features/Applications Application-specific Models Wafer Mapping Features * W afers are reliable detected with an ultrafine beam. * The optical axis is adjusted before delivery to allow easy installation. Optical axis adjusted before delivery so that displacement is typically within 0.1. Direction of rotation E32-A03 Vertical rotation Engineering Data E32-A03-1 8-inch Wafer Mapping Characteristic (Typical Examples) Rate of change of digital light-intensity value (%) 180 160 Wafer piles can also be detected 140 120 100 80 170 mm 60 40 For 1 wafer For 2 wafers -10 2-wafer pile -9 -8 -7 -6 -5 -4 -3 -2 Fiber 6.35 mm 20 0 X Fiber -1 0 1 2 3 Silicon wafer (t = 0.75 mm) 4 Overview of Model Variations Type Features Shape, sensing distance (mm)* Opening angle: 1.5 Through-beam 890 With mounting flange Opening angle: 3 ultraslim 340 With mounting flange Model number E32-A03 E32-A03-1 E32-A04 E32-A04-1 True Color Detection * Use E32 fiber units with E3X-DAC amplifiers (see page 79) to accurately detect all RGB wavelengths Precise Color Detection Color vs. Detection Capability hi t Re e d Ye llo w Ye -re llo d Ye w llo G w-g re re e Bl n en ue Bl -gre ue e n Bl ue Vi vio ol le e t Re t dvio le t Color Detection (Color Sensing Type) W Intensity Detection (Conventional Type) Unstable... White Red Yellow-red Yellow Yellow-green Green Blue-green RGB ratio Incident light intensity 90 10 100 90 100 100 100 Blue Blue-violet 90 80 10 No Need to Select Separate Red, Green, Blue LED Amplifiers A high-power white LED and a multi-RGB processing system combine to cover all RGB wavelengths, enabling easy and accurate detection of workpieces without having to use a different light source to match each one. Resists Movement Changes in the three parameters are processed as a ratio, so they are not affected by light-intensity variations due to workpiece movement. *The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode). 16 Violet Red-violet Application-specific Models Applications Detecting Opaque Marks--Reflective Detecting Translucent Marks Because it distinguishes RGB ratios, detection is highly resistant to workpiece movement. Detecting color differences in translucent marks on film with easy-to-install U-shaped sensing head. Distinguishing Products Distinguishing Trays Detection is highly resistant to the effects of backgrounds and surface protrusions. Twin sensing and remote control functions simplify setup of color sortation on a multi-product line. Distinguishing Semi-Transparent Objects Detecting Wafers Through-beam Fiber Heads are capable of detecting color differences in semi-transparent objects. Workpieces that absorb a specific wavelength can be detected with a wide range of wavelengths. Overview of Model Variations Type Through-beam Reflective Features Shape Sensing distance (mm)* Opaque object Translucent object Model number 110 22 E32-T11R Long distance 3,200 600 E32-T17L Long distance 70 13 E32-D11L Coaxial, M6 screw 45 9 M4 screw E32-CC200 *The sensing distances apply for use in combination with the E3X-DAC-S Amplifier Unit (general-purpose, standard mode). 17 Ordering Information Through-beam Fiber Units *1. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. Indicates models that allow free cutting. *2. High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-MDA Unit. When used in combination with E3X-NA-F high speed unit. Type Appearance (mm) *2 When used in combination with E3X-NA or E3X-SD standard units. Sensing distance (mm) Standard object Min. (min. sensing bending object) (mm) *1 radius (mm) Features Model number M4 screw E32-T11R 3-dia. cylinder E32-T12R M4 700 530 140 3 dia. 450 350 140 280 80 Standard size 15 x 8 x 3 90 (40) ( ): E32-TC200B4R Flat shape M4 screw, with 90 mm M4 screw, with 40 mm 3-dia. cylinder, side-view 270 210 Flexible (new standard) Standard models E32-TC200B4R sleeve 3 dia. 50 170 130 50 110 33 15 x 8 x 3 E32-TC200BR sleeve 1 dia. (0.005 dia.) M4 1.2 dia. Min. bending radius of sleeve: 5 E32-T15XR E32-T14LR Flat shape, side-view E32-T15YR Flat shape, flat-view E32-T15ZR M3 screw (small) E32-T21R 2-dia. cylinder (small) E32-T22R 15 x 8 x 3 R R1 M3 160 130 30 100 75 30 60 18 2 dia. Small size 1.5 dia 12 x 7 x 2 90 (40) 1.5-dia. cylinder (small) Flat shape (small) 0.5 dia. (0.005 dia.) ( ): E32-TC200F4R M3 0.9 dia. Min. bending radius of sleeve: 5 E32-T222R E32-T25XR M3 screw (small), with 90 mm sleeve E32-TC200FR M3 screw (small), with 40 mm sleeve E32-TC200F4R 1 dia. 12 x 7 x 2 1-dia. cylinder (small), 60 50 10 35 27 10 30 9 side-view Flat shape (small), R : Flexible fiber B : Bendable fiber E32-T25YR side-view Flat shape (small), flat-view 12 x 7 x 2 18 E32-T24R U : Fluorine-coated fiber E32-T25ZR Through-beam Fiber Units *1. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. Indicates models that allow free cutting. *2. High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-MDA Unit. When used in combination with E3X-NA-F high speed unit. Type Appearance (mm) *2 When used in combination with E3X-NA or E3X-SD standard units. Sensing distance (mm) Standard object Min. (min. sensing bending object) (mm) *1 radius (mm) Features M4 screw Model number E32-TC200 M4 1,000 760 3-dia. cylinder 200 M4 650 500 Standard size Flat shape 200 400 120 15 x 8 x 3 90 (40) ( ): E32-TC200B4R M4 1.2 dia. Min. bending radius of sleeve: 5 3 dia. 600 460 1 dia. (0.005 dia.) 120 390 300 120 240 70 Standard 15 x 8 x 3 Standard models R25 E32-T12 E32-T15X M4 screw, with 90 mm sleeve E32-TC200B M4 screw, with 40 mm sleeve E32-TC200B4 3-dia. cylinder, side-view E32-T14L Flat shape, side-view E32-T15Y Flat shape, flat-view E32-T15Z 15 x 8 x 3 900 680 M3 180 580 450 E32-TC200A M3 screw (small) 180 360 100 E32-TC200E Small size M3 2 dia. 50 170 130 50 100 30 1.5 dia 12 x 7 x 2 90 (40) 2-dia. cylinder (small) 270 220 0.5 dia. (0.005 dia.) ( ): E32-TC200F4R : Flexible fiber B : Bendable fiber 1.5-dia. cylinder (small) E32-T222 Flat shape (small) E32-T25X M3 screw (small), with 90 mm sleeve E32-TC200F M3 screw (small), with 40 mm sleeve M3 0.9 dia. Min. bending radius of sleeve: 5 R R10 U E32-T22 E32-TC200F4 : Fluorine-coated fiber 19 Ordering Information Through-beam Fiber Units *1. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. Indicates models that allow free cutting. *2. High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-MDA Unit. When used in combination with E3X-NA-F high speed unit. Type Appearance (mm) *2 When used in combination with E3X-NA or E3X-SD standard units. Sensing distance (mm) Standard object Min. (min. sensing bending object) (mm) *1 radius (mm) Features Model number Small size Standard 1 dia. 12 x 7 x 2 1-dia. cylinder E32-T24 (small), side-view 160 130 30 100 70 30 90 27 0.5 dia. (0.005 dia.) R10 12 x 7 x 2 Standard size 900 680 M4 Flat shape E32-T25Y (small), side-view Flat shape (small), flat-view E32-T25Z M4 screw E32-T11 180 580 450 1 dia (0.005 dia.) 3-dia. cylinder 180 360 100 3 dia. Flat shape E32-T12B E32-T15XB Break-resistant 2 dia. Right angle Standard 20 : Flexible fiber 45 150 110 45 100 30 B R4 0.5 dia (0.005 dia.) 1.5 dia 12 x 7 x 2 R 240 200 M3 Small size Standard models 15 x 8 x 3 180 150 35 125 95 35 75 20 M3 screw (small) E32-T21 2-dia. cylinder (small) E32-T221B 1.5-dia. cylinder (small) E32-T22B Flat shape (small) E32-T25XB M4 screw, right angle E32-T11N 700 530 140 M4 B 450 350 140 280 80 : Bendable fiber U : Fluorine-coated fiber 1 dia (0.005 dia.) R R1 Through-beam Fiber Units *1. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. Indicates models that allow free cutting. *2. High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-MDA Unit. When used in combination with E3X-NA-F high speed unit. Right angle Standard Appearance (mm) *2 Sensing distance (mm) 4,000 3,700 970 3,100 2,400 970 2,100 M4 R 4 dia (0.005 dia.) R1 1 dia (0.005 dia.) R4 Features M4 screw, right angle, long distance Model number E32-T11N+ E39-F1 Standard size 900 M4 680 180 580 450 180 360 100 20,000*3 20,000*3 4,000 13,000 10 dia. 10,000 4,000 14,000 4,200 M14 4,000*4 4,000*4 1,500 4,000 3,700 1,500 3,000 900 Long-distance, high-power Special-beam models Standard object Min. (min. sensing bending object) (mm) *1 radius (mm) 630 Chemical resistant Standard models Type When used in combination with E3X-NA or E3X-SD standard units. 4,000*4 3,700 970 3,100 2,400 970 2,100 M4 4 dia. (0.1 dia.) U M4 screw, fluorine coating E32-T11U Large built-in lens, M14 screw E32-T17L M4 screw E32-TC200+ E39-F1 M4 screw, flexible fiber E32-T11R+ E39-F1 M4 screw, break-resistant E32-T11+ E39-F1 R25 R R1 630 4,000*4 3,700 930 3,000 2,300 930 2,000 B R4 600 *3. The optical fiber is 10 m long on each side permitting a sensing distance of 20,000 mm. *4. The optical fiber is 2 m long on each side permitting a sensing distance of 4,000 mm. : Flexible fiber : Bendable fiber : Fluorine-coated fiber R B U 21 Ordering Information Through-beam Fiber Units *1. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. Indicates models that allow free cutting. *2. High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-MDA Unit. When used in combination with E3X-NA-F high speed unit. Type Appearance (mm) *2 When used in combination with E3X-NA or E3X-SD standard units. Sensing distance (mm) 4,000*3 3,400 900 2,900 2,200 900 1,800 Standard object Min. (min. sensing bending object) (mm) *1 radius (mm) 4 dia. (0.1 dia.) Features Model number Screw mounting, side view E32-T14 M4 screw E32-T11L 3-dia. cylinder E32-T12L M4 screw, side-view E32-T11L+ E39-F2 M4 screw, side-view, flexible fiber E32-T11R+ E39-F2 M4 screw, side-view, break-resistant E32-T11+ E39-F2 M3 screw (small) E32-T21L 2-dia. cylinder (small) E32-T22L 540 1,700 1,330 M4 350 1,100 870 1.4 dia. (0.01 dia.) R25 350 700 3 dia. 210 910 800 600 520 Long-distance, high-power Special-beam models 180 180 220 65 520 400 100 330 260 100 220 65 M4 3 dia. (0.1 dia.) R R1 820 660 160 B 530 430 R4 160 360 100 540 440 M3 100 340 260 100 200 60 2 dia. *3. The optical fiber is 2 m long on each side permitting a sensing distance of 4,000 mm. : Flexible fiber : Bendable fiber : Fluorine-coated fiber R 22 B U 0.9 dia. (0.005 dia.) R10 Through-beam Fiber Units *1. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. Indicates models that allow free cutting. *2. High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-MDA Unit. When used in combination with E3X-NA-F high speed unit. Type Appearance (mm) *2 1 dia 3 dia. 0.5 dia. Ultracompact, thin-sleeve Special-beam models Sleeve cannot be bent. 3 dia. 0.25 dia. Sleeve cannot be bent. 3 dia. 0.22 dia. Sleeve cannot be bent. When used in combination with E3X-NA or E3X-SD standard units. Sensing distance (mm) Standard object Min. (min. sensing bending object) (mm) *1 radius (mm) Features Model number 160 130 30 110 85 30 60 18 0.5 dia. (0.005 dia.) 53 44 10 35 28 10 20 6 0.25 dia. (0.005 dia.) 12 10 4 8 6 4 5 1.5 0.125 dia. (0.005 dia.) 6 5 2 4 3 2 2.5 0.8 0.1 dia. (0.005 dia.) 0.22-dia. sleeve; 0.1-dia. opening E32-T334-S5 1.7 dia. (0.1 dia.) 3-dia. cylinder E32-T22S 3.5-dia. cylinder, side-view E32-T24S R R1 1-dia. cylinder, flexible fiber E32-T223R 0.5-dia. sleeve; E32-T33-S5 0.25-dia. opening R10 0.25-dia. sleeve; 0.125-dia. opening E32-T333-S5 2,500 1,900 500 3 dia 1,600 1,250 Fine-beam 500 1,000 300 R10 1,750 1,300 3.5 dia. 350 1,100 870 2 dia. (0.1 dia.) 350 700 210 R : Flexible fiber B : Bendable fiber U : Fluorine-coated fiber 23 Ordering Information Through-beam Fiber Units *1. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. Indicates models that allow free cutting. *2. High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-MDA Unit. When used in combination with E3X-NA-F high speed unit. Type Appearance (mm) *2 When used in combination with E3X-NA or E3X-SD standard units. Sensing distance (mm) Standard object Min. (min. sensing bending object) (mm) *1 radius (mm) Features Model number 1,100 840 220 R 730 560 E32-T16PR R1 220 450 130 Area width: 11 mm 1,500 1,100 11 300 970 R10 750 E32-T16P 300 600 180 980 (0.2 dia.) *3 750 R 600 480 Area-sensing Special-beam models 190 190 390 110 Area width: 11 mm; side-view 1,300 1,000 11 E32-T16JR R1 260 800 R10 650 E32-T16J 260 520 150 1,700 1,300 340 R 1,100 860 E32-T16WR R1 340 690 200 2,300 1,800 30 Area width: 30 mm (0.3 dia.) *3 450 1,400 1,100 R10 450 920 270 *3. This is the value for which detection is possible within the sensing area, with the sensing distance set to 300 mm. (The sensing object is stationary.) : Flexible fiber : Bendable fiber : Fluorine-coated fiber R 24 B U E32-T16W Through-beam Fiber Units *1. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. Indicates models that allow free cutting. *2. High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-MDA Unit. When used in combination with E3X-NA-F high speed unit. Type Appearance (mm) *2 When used in combination with E3X-NA or E3X-SD standard units. Sensing distance (mm) Standard object Min. (min. sensing bending object) (mm) *1 radius (mm) Features Model number 2,200 1,800 450 1,400 Area width: 50 mm E32-ET16WR-2 Area width: 70 mm E32-ET16WR-1 550 1,700 2,400 2,000 (5 dia.) *4 R R1 2,500 1,500 600 900 Area-sensing Special-beam models 500 3,700 2,800 740 10 2,400 1,800 (0.6 dia) *4 740 Area width: 10 mm; long distance E32-T16 Multi-point detection (4-head) E32-M21 Heat-resistant up to 150C E32-T51 Heat-resistant up to 150C; side-view E32-T54 1,500 450 R25 750 610 140 M3 2 dia. (0.1 dia.) 470 360 140 300 90 1,000 760 200 150C*5 650 500 Heat-resistant Environment-resistive models M4 200 400 120 2 dia. 300 230 60 190 150 60 130 35 1.5 dia. (0.1 dia.) R35 *4. This is the value for which detection is possible within the sensing area, with the sensing distance set to give a digital value of 1,000. (The sensing object is stationary.) *5. For continuous operation, use the products within a temperature range of-40C to 130C. : Flexible fiber : Bendable fiber : Fluorine-coated fiber R B U 25 Ordering Information Through-beam Fiber Units *1. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. Indicates models that allow free cutting. *2. High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-MDA Unit. When used in combination with E3X-NA-F high speed unit. Type Appearance (mm) *2 When used in combination with E3X-NA or E3X-SD standard units. Sensing distance (mm) Standard object Min. (min. sensing bending object) (mm) *1 radius (mm) Features Model number 360 280 M4 70 1 dia. (0.005 dia.) 230 180 70 180 50 Heat-resistant up to 200C *3 E32-T81R-S 3 dia. (0.1 dia.) Heat-resistant up to 200C *3; side-view E32-T61-S+ E39-F2 4 dia. (0.1 dia.) Heat-resistant up to 200C *3, long distance E32-T61-S+ E39-F1 1.7 dia. (0.1 dia.) Heat-resistant up to 200C *3; L-shaped; long distance E32-T84S-S 1 dia. (0.005 dia.) Heat-resistant up to 350C *3 E32-T61-S Fluororesin cover, round head E32-T11F R10 600 450 120 230 180 70 180 50 4,000*4 3,400 900 3,000 2,200 900 3,000 900 M4 Heat-resistant Environment-resistive models 200C M4 R25 1,750 1,300 3 dia. 350 1,100 870 350 700 210 600 450 M4 350C 120 390 300 120 900 Chemical-resistant 90 2,500 2,000 520 7.2 dia. 1,600 1,300 4 dia. (0.1 dia.) 520 1,050 380 *3. The maximum temperature that can be withstood varies with the location. Refer to dimensions diagrams for details. *4. The optical fiber is 2 m long on each side permitting a sensing distance of 4,000 mm. : Flexible fiber : Bendable fiber : Fluorine-coated fiber R 26 B U U R4 Through-beam Fiber Units *1. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. Indicates models that allow free cutting. *2. High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-MDA Unit. When used in combination with E3X-NA-F high speed unit. Type Appearance (mm) *2 When used in combination with E3X-NA or E3X-SD standard units. Sensing distance (mm) 4,000*3 3,000 800 2,600 2,000 800 1,600 5 dia. Standard object Min. (min. sensing bending object) (mm) *1 radius (mm) 4 dia. (0.1 dia.) Features Model number Fluororesin cover, long distance E32-T12F Fluororesin cover, side-view E32-T14F 480 500 400 Chemical-resistant Environment-resistive models 5 dia. 100 320 250 100 200 60 3 dia. (0.1 dia.) U R40 1,800 1,400 350 5 dia. 1,190 920 Fluororesin cover, heat-resistant up to 150C *4 4 dia. (0.1 dia.) 350 E32-T51F 700 200 920 700 6 dia. 190 1 dia. (0.005 dia.) 600 460 190 350 100 U R10 Fluororesin cover, heat-resistant up to 200C *5 E32-T81F-S M4 screw, heat-resistant up to 120C E32-T51V 1M M4 screw, heat-resistant up to 120C, long distance E32-T51V 1M+ E39-F1V 260 200 Vacuum-resistant 50 170 130 50 100 1.2 dia (0.01 dia.) R30 1,350 1,000 260 850 650 4 dia. (0.1 dia.) 260 600 *3. 2 m long on each side permitting a sensing distance of 4,000 mm. *4. For continuous operation, use the product within a range or -40 to 130C. *5. The maximum temperature that can be withstood varies with location. Refer to dimensions diagrams for details. : Flexible fiber : Bendable fiber : Fluorine-coated fiber R B U 27 Ordering Information Through-beam Fiber Units *1. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. Indicates models that allow free cutting. *2. High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-MDA Unit. When used in combination with E3X-NA-F high speed unit. Appearance (mm) *2 Sensing distance (mm) 210 130 35 110 85 35 65 Standard object Min. (min. sensing bending object) (mm) *1 radius (mm) 180 420 320 180 390 410 310 130 250 Flanges Appearance (mm) Model number E32-T54V 1M 4 dia. (0.1 dia.) L-shaped, heat-resistant up to 120C, long distance E32-T54V 1M+ E36-F1V 2 dia. (0.1 dia.) L-shaped, heat-resistant up to 200C, long distance T32-T84SV 1M R30 630 480 130 Features L-shaped, heat-resistant up to 120C 1.2 dia. (0.01 dia.) 660 500 Vacuum-resistant Environment-resistive models Type When used in combination with E3X-NA or E3X-SD standard units. R25 Lens Units Type 4-channel flange Model number Appearance (mm) Type Quantity Remarks 2 Long-distance Lens Unit Can be used for the E32-51V and the E32-T54V. Type Quantity Remarks E39-L54V 2 E39-F1V E32-VF4 Mounting Brackets 1-channel flange E32-VF1 Fiber Units for Atmospheric-pressure Side Appearance Type Amplifier-Flange Connection Fiber 28 Model number E32-T10V 2M Appearance (mm) Can be used for the E32-T54V. Fiber Units with Reflective Sensors *1. The sensing distances are for white paper. *2. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. *3. Indicates models that allow free cutting. High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-MDA Unit. When used in combination with E3X-NA-F high speed unit. Type Appearance (mm) *3 15 x 10 x 3 M6 Min. sensing object (mm) *2 Min. bending radius (mm) 300 170 50 300 170 50 90 30 Features E32-D11R 3-dia. cylinder E32-D12R M6 screw, with 90 mm sleeve 2.5 dia. 80 45 14 45 33 14 16 4 6 dia. 70 40 12 40 29 12 20 5 15 x 10 x 3 15 x 10 x 3 (0.005 dia.) R R1 M4 M3 Small size 3 dia. 12 x 8 x 3 50 30 8 30 22 8 15 5 : Flexible fiber B : Bendable fiber U E32-DC200BR E32-DC200B4R 6-dia. cylinder, side-view E32-D14LR Flat shape, side-view E32-D15YR Flat shape, flat-view E32-D15ZR E32-D211R M3 screw (small) E32-D21R 3-dia. cylinder (small) E32-D22R Flat panel (small) M3 1.2 dia. Min. bending radius of sleeve: 5 E32-T15XR M6 screw, with 40 mm sleeve M4 screw (small) R Model number M6 screw Flat shape Sleeve cannot be bent. Flexible (new standard) Standard size Sensing distance (mm) *1 M6 3 dia. Standard models When used in combination with E3X-NA or E3X-SD standard units. E32-D25XR M3 screw (small), with 90 mm sleeve E32-DC200FR M3 screw (small), with 40 mm sleeve E32-DC200F4R : Fluorine-coated fiber 29 Ordering Information Fiber Units with Reflective Sensors *1. The sensing distances are for white paper. *2. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. *3. Indicates models that allow free cutting. High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-MDA Unit. When used in combination with E3X-NA-F high speed unit. Type Appearance (mm) *3 Sensing distance (mm) *1 Min. sensing object (mm) *2 26 15 4 15 10 4 7 2.3 Small size 2 dia. Flexible (new standard) When used in combination with E3X-NA or E3X-SD standard units. 12 x 8 x 2 Features Model number 2-dia. cylinder E32-D24R (small), side-view R R1 14 8 2 8 5 2 4 1.2 12 x 8 x 2 Min. bending radius (mm) Flat shape E32-D25YR (small), side-view Flat shape (small), flat-view E32-D25ZR M6 screw E32-DC200 3-dia. cylinder E32-D12 500 300 90 M6 Standard models 300 210 90 150 5 400 230 Standard size Standard 230 160 70 120 40 500 300 M6 2.5 dia. Sleeve cannot be bent. 6 dia. 30 : Flexible fiber B R25 Flat shape E32-T15X 90 15 x 10 x 3 ( ): E32-DC200B4 R 70 3 dia. 90 (40) (0.005 dia.) 300 210 90 150 50 M6 screw, with 90 mm sleeve 200 110 36 110 80 36 40 13 : Bendable fiber U : Fluorine-coated fiber E32-DC200B M6 screw, with 40 mm sleeve E32-DC200B4 6-dia. cylinder, side-view E32-D14L Fiber Units with Reflective Sensors *1. The sensing distances are for white paper. *2. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. *3. Indicates models that allow free cutting. High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-MDA Unit. When used in combination with E3X-NA-F high speed unit. Appearance (mm) *3 Standard size Type When used in combination with E3X-NA or E3X-SD standard units. Sensing distance (mm) *1 Min. sensing object (mm) *2 170 100 30 100 70 30 50 15 15 x 10 x 3 15 x 10 x 3 Min. bending radius (mm) Features Flat shape, side-view E32-D15Y Flat shape, flat-view E32-D15Z R25 M4 screw (small) M4 M3 Standard 12 x 8 x 2 M3 1.2 dia. Min. bending radius of sleeve: 5 2 dia. Standard size Break-resistant 12 x 8 x 2 : Flexible fiber M6 15 x 10 x 3 B (0.005 dia.) 50 30 8 30 22 8 15 5 R10 M3 screw (small) E32-DC200E 3-dia. cylinder (small) E32-D22 Flat shape (small) E32-D25X M3 screw (small), with 90 mm sleeve E32-DC200F M3 screw (small), with 40 mm sleeve E32-DC200F4 Flat shape E32-D25Y (small), side-view 300 170 50 170 125 50 90 30 : Bendable fiber E32-D211 2-dia. cylinder E32-D24 (small), side-view 35 20 6 20 14 6 10 3.3 12 x 8 x 2 R 130 80 22 80 55 22 36 12 90 (40) ( ): E32-DC200F4 Small size Standard models 3 dia. Model number U Flat shape (small), flat-view E32-D25Z M6 screw E32-D11 B R4 Flat shape E32-D15XB : Fluorine-coated fiber 31 Ordering Information Fiber Units with Reflective Sensors *1. The sensing distances are for white paper. *2. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. *3. Indicates models that allow free cutting. High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-MDA Unit. When used in combination with E3X-NA-F high speed unit. Type Appearance (mm) *3 M4 Small size Break-resistant 3 dia. M3 1.5 dia. Standard models 12 x 8 x 2 Right angle Area-sensing R 32 : Flexible fiber B M6 M6 M3 When used in combination with E3X-NA or E3X-SD standard units. Sensing distance (mm) *1 Min. sensing object (mm) *2 Min. bending radius (mm) 110 70 20 70 50 20 35 10 50 30 8 30 22 8 15 5 Model number M4 screw (small) E32-D21B 3-dia. cylinder (small) E32-D221B M3 screw (small) E32-D21 1.5-dia. cylinder (small) E32-D22B B R4 85 50 15 50 35 15 25 8 Flat shape (small) E32-D25XB M6 screw, right angle E32-D11N M6 screw, right angle E32-C11N M3 screw, right angle E32-C31N (0.005 dia.) 300 170 50 170 120 50 90 30 R R1 280 170 50 160 110 50 90 30 B R4 40 25 7 24 16 7 10 3.3 : Bendable fiber Features U : Fluorine-coated fiber Fiber Units with Reflective Sensors *1. The sensing distances are for white paper. *2. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. *3. Indicates models that allow free cutting. High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-MDA Unit. When used in combination with E3X-NA-F high speed unit. Standard size Appearance (mm) *3 Chemical resistance Standard models Type M6 Long-distance, high-power Special-beam models 17.5 Min. sensing object (mm) *2 300 170 50 170 125 50 90 30 (0.005 dia. ) 40 to 1,000 40 to 700 40 to 240 40 to 600 40 to 490 40 to 240 40 to 400 55 to 70 -- Min. bending radius (mm) U Features Model number M6 screw, fluorine coating E32-D11U R4 Large built-in lens, screw mounting E32-D16 R25 M6 screw E32-D11L M4 screw E32-D21L 3-dia. cylinder E32-D22L 0.8-dia. sleeve E32-D33 0.5-dia. sleeve E32-D331 R4 B 650 110 M6 400 270 110 200 65 210 130 30 130 85 35 50 17 M4 3 dia. Ultracompact, thin sleeve Sensing distance (mm) *1 400 3 dia. Sleeve cannot be bent. R When used in combination with E3X-NA or E3X-SD standard units. 0.8 dia. 2 dia. 0.5 dia. Sleeve cannot be bent. : Flexible fiber B R10 (0.005 dia. ) 25 16 4 16 10 4 10 3.3 B R4 5 3 0.8 3 2 0.8 1.5 0.5 : Bendable fiber U : Fluorine-coated fiber 33 Ordering Information Fiber Units with Reflective Sensors *1. The sensing distances are for white paper. *2. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. *3. Indicates models that allow free cutting. High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-MDA Unit. When used in combination with E3X-NA-F high speed unit. Type Appearance (mm) *3 When used in combination with E3X-NA or E3X-SD standard units. Sensing distance (mm) *1 Min. sensing object (mm) *2 250 150 45 150 105 45 75 25 Min. bending radius (mm) R Model number E32-CC200R R4 M6 screw 500 300 M6 Features 90 300 210 90 150 50 Coaxial, small-spot Special-beam models 3 dia. M3 2 dia. E32-CC200 250 150 45 150 100 45 80 25 3-dia. cylinder E32-D32L M3 screw (small) E32-C31 2-dia. cylinder (small) E32-D32 (0.005 dia.) 120 75 22 75 50 22 40 13 R25 6 to 15 mm; spot diameter: 0.1 to 0.6 mm Spot diameter of 0.5 to 1 mm at distances in the range 6 to 15 mm Small spot (variable) Spot diameter of 0.1 mm at 7 mm E32-C42+ E39-F3A E32-D32+ E39-F3A E32-C41+ E39-F3A-5 Small spot Spot diameter of 0.5 mm at 7 mm E32-C31+ E39-F3A-5 Spot diameter of 0.2 mm at 17 mm E32-C41+ E39-F3B Spot diameter of 0.5 mm at 17 mm R 34 : Flexible fiber B : Bendable fiber U : Fluorine-coated fiber Long distance, small spot E32-C31+ E39-F3B Fiber Units with Reflective Sensors *1. The sensing distances are for white paper. *2. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. *3. Indicates models that allow free cutting. High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-MDA Unit. When used in combination with E3X-NA-F high speed unit. Appearance (mm) *3 Sensing distance (mm) *1 (0.005 dia.) Area-sensing 250 150 45 150 100 45 75 25 Retroflective (0.1 dia.) 150 to 1,500 150 to 1,500 150 to 1,500 150 to 1,500 150 to 1,500 150 to 1,500 150 to 1,500 150 to 1,500 E39-R1 Reflector 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 Limited-reflective : Flexible fiber (0.005 dia.) 10 to 250 10 to 250 10 to 250 10 to 250 10 to 250 10 to 250 10 to 250 10 to 250 E39-R3 Reflector Special-beam models Min. bending radius (mm) Features R25 Long-distance sensing, parallel light E32-C31+ E39-F3C Beam width: 11 mm E32-D36P1 R10 M6 screw E32-R21+ E39-R3 (Reflector supplied.) R25 Screw mounting, long distance E32-R16+ E39-R1 (Reflector supplied.) Small level differences, high power, side-view E32-L25 Small level differences, high power, top-view E32-L25A Ultracompact, flat-view E32-L24S 4-dia. spot M6 R Min. sensing object (mm) *2 Spot diameter of 4 mm max. at distances in the range 0 to 20 mm Coaxial, small-spot Type When used in combination with E3X-NA or E3X-SD standard units. R25 (0.005 dia.) 0 to 4 0 to 4 0 to 4 0 to 4 0 to 4 0 to 4 0 to 4 0 to 4 B : Bendable fiber (0.2 dia.) B R4 Model number U R10 : Fluorine-coated fiber 35 Ordering Information Fiber Units with Reflective Sensors *1. The sensing distances are for white paper. *2. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. *3. Indicates models that allow free cutting. High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-MDA Unit. When used in combination with E3X-NA-F high speed unit. Type Appearance (mm) *3 When used in combination with E3X-NA or E3X-SD standard units. Sensing distance (mm) *1 Min. sensing object (mm) *2 5.4 to 9 (center: 7.2) 5.4 to 9 (center: 7.2) 5.4 to 9 (center: 7.2) 5.4 to 9 (center: 7.2) 5.4 to 9 (center: 7.2) 5.4 to 9 (center: 7.2) 5.4 to 9 (center: 7.2) 5.4 to 9 (center: 7.2) Limited-reflective Special-beam models 2 to 6 (center: 4) 2 to 6 (center: 4) 2 to 6 (center: 4) 2 to 6 (center: 4) 2 to 6 (center: 4) 2 to 6 (center: 4) 2 to 6 (center: 4) 2 to 6 (center: 4) 4 to 10 4 to 10 4 to 10 4 to 10 4 to 10 4 to 10 4 to 10 4 to 10 Heat resistant up to 105C *4, top-view E32-L24L Heat resistant up to 105C *4, top-view E32-L25L (0.005 dia.) Heat resistant up to 200C, flat-view E32-L86 R25 Wide-range sensing, flat-view E32-L16 Heat resistant up to 150C E32-D51 72 150C Heat-resistant Environment-resistive models 36 Model number 400 230 M6 230 165 72 120 40 *4. For continuous operation, use the products within a temperature range of -40C to 90C. *5. For continuous operation, use the products within a temperature range of -40C to 130C. : Flexible fiber : Bendable fiber : Fluorine-coated fiber R Features R10 0 to 15 0 to 15 0 to 12 0 to 15 0 to 15 0 to 12 0 to 15 0 to 13 Min. bending radius (mm) B U (0.005 dia.) R35 Fiber Units with Reflective Sensors *1. The sensing distances are for white paper. *2. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. *3. Indicates models that allow free cutting. High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-MDA Unit. When used in combination with E3X-NA-F high speed unit. Appearance (mm) *3 350C 400C M6 M6 M4 1.25 dia. Min. bending radius of sleeve: 10 6 dia. Chemical-resistant Environment-resistive models Heat-resistant 200C Type Sensing distance (mm) *1 150 90 27 90 63 27 45 15 100 60 18 60 40 18 30 10 160 95 30 95 70 30 50 16 70 40 10 40 28 10 20 6.5 6 dia. When used in combination with E3X-NA or E3X-SD standard units. Min. sensing object (mm) *2 Min. bending radius (mm) Features Model number R10 Heat resistant up to 200C *4 E32-D81R-S E32-D81R R25 Heat resistant up to 350C *4 E32-D61-S E32-D61 R25 Heat resistant up to 400C *4, with sleeve E32-D73-S E32-D73 Fluororesin cover, long distance E32-D12F (0.005 dia.) (0.005 dia.) U R40 Fluororesin cover, side-view E32-D14F *4. The maximum temperature that can be withstood varies with the location. Refer to dimensions diagrams for details. : Flexible fiber : Bendable fiber : Fluorine-coated fiber R B U 37 Ordering Information Application-specific Fiber Units *1. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. Indicates models that allow free cutting. *2. High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-MDA Unit. When used in combination with E3X-NA-F high speed unit. Appearance (mm) *2 Sensing distance (mm) 10 10 10 10 10 10 10 10 Label-dection Type When used in combination with E3X-NA or E3X-SD standard units. 4,500 3,400 900 2,900 2,200 900 1,800 Standard object (min. sensing object) (mm) *1 4 dia. (0.1 dia.) Min. bending radius (mm) Features Model number Slot sensor (no adjustment of optical axis required) E32-G14 Screw mounting, side-view E32-T14 Compact E32-L25T R25 Application-specific models 540 Label-level detection Applicable tube: Transparent tube with a diameter in the range 8 to 10 mm and a recommended wall thickness of 1 mm R10 Applicable tube: Transparent tube (no restriction on diameter) No restriction on tube diameter, resistant to bubbles and drops of water Applicable tube: Transparent tube with a diameter of 3.2, 6.4, or 9.5 mm and a recommended wall thickness of 1 mm Light ON when fluid is present, resistant to bubbles and drops of water E32-A01 Light ON when fluid is not present, resistant to bubbles and drops of water E32-A02 Heat resistant up to 200C, fluororesin cover E32-D82F1 E32-D82F2 B R4 Applicable tube: Transparent tube with a diameter in the range 6 to 13 mm and a recommended wall thickness of 1 mm E32-D36T Liquid-contact models R40 R 38 : Flexible fiber B : Bendable fiber U : Fluorine-coated fiber Application-specific Fiber Units *1. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. Indicates models that allow free cutting. *2. High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-MDA Unit. When used in combination with E3X-NA-F high speed unit. Appearance (mm) *2 Sensing distance (mm) Glass-substrate-alignment 0 to 15 0 to 15 0 to 12 0 to 15 0 to 15 0 to 12 0 to 15 0 to 13 Standard object (min. sensing object) (mm) *1 Soda glass with reflection factor of 7% 10 to 20 10 to 20 Features R25 Variation of detection position within the detection range: 0.2 mm 5 to 18 5 to 18 5 to 18 15 to 38 (center: 25) 15 to 38 (center: 25) 20 to 30 (center: 25) 20 to 30 (center: 25) Water-mapping E32-A08 Edge of soda glass with reflection factor of 7% (t = 0.5 mm, rounded edge) Heat resistant up to 300C *4, *5 R25 Resistant to tilting R35 Heat resistant up to 150C *3 E32-A09H R25 Heat resistant up to 300C *4, *5 E32-A09H2 R1 1,150 890 250 2 dia. (0.1 dia.) R10 1,750 1,300 3.5 dia. E32-L16 R25 R 3 dia. Model number E32-A07E1 E32-A07E2 3 dia. Application-specific models Min. bending radius (mm) 15 to 25 15 to 25 Glass-substrate-mapping Application-specific models Type When used in combination with E3X-NA or E3X-SD standard units. 350 Opening angle: 1.5; optical axis adjusted before delivery Opening angle: 1.5; with mounting flange; optical axis adjusted before delivery Long distance; opening angle: 6 E32-L66 E32-A09 E32-A03 E32-A03-1 E32-T24S *3. For continuous operation, use the products within a temperature range of -40C to 130C. *4. The maximum temperature that can be withstood varies with the location. Refer to dimensions diagrams for details. *5. These values are based on the assumption that there are no repeated sudden changes in temperature. : Flexible fiber : Bendable fiber : Fluorine-coated fiber R B U 39 Ordering Information Application-specific Fiber Units *1. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. Indicates models that allow free cutting. *2. High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). High-resolution mode Standard mode Super-high-speed mode. When used in combination with the E3X-MDA Unit. When used in combination with E3X-NA-F high speed unit. 40 Appearance (mm) *2 Sensing distance (mm) Standard object (min. sensing object) (mm) *1 Min. bending radius (mm) 2 dia. 460 340 100 1.2 dia. (0.1 dia.) Features Ultra-slim (t = 2 mm); opening angle: 3; optical axis adjusted before delivery 2 dia. Water-mapping Application-specific models Type When used in combination with E3X-NA or E3X-SD standard units. R10 Ultra-slim (t = 2 mm); opening angle: 3; with mounting flange; optical axis adjusted before delivery Model number E32-A04 E32-A04-1 Through-beam Fiber Units used with E3X-DAC True Color Amplifier Long-distance, high-power Special-beam models Fluorine coating Break-resistant Standard models General purpose Type Applicable Fiber Units Sensing distance (mm) with opaque object Sensing distance (mm) with translucent object* High resolution mode Standard mode Super high-speed mode High resolution mode Standard mode Super high-speed mode E32-TC200 200 160 70 45 32 22 E32-T11R/ E32-T12R/ E32-T15XR/ E32-TC200BR/ E32-TC200 B4R 150 110 50 30 22 16 E32-T14LR/ E32-T15YR/ E32-T15ZR 55 4 19 12 8.5 E32-TC200E/ E32-T22/ E32-T222/ E32-T25X/ E32-TC200F/ E32-TC200F4 80 60 46 17 12 7 E32-T24/ E32-T25Y/ E32-T25Z 48 36 26 10 7 4 E32-T11/ E32-T12B/ E32-T15XB 190 140 60 40 28 20 E32-T21/ E32-T221B/ E32-T22B 70 55 40 15 11 6 E32-T25XB 55 42 30 11 8 4.5 E32-T11U 190 140 60 40 28 20 E32-T17L 4,300 3,200 1,400 900 600 460 E32-TC200+ E39-F1 1,100 850 360 220 160 120 E32-T11R+ E39-F1 1,000 750 340 220 150 110 E32-T11+ E39-F1 1,000 750 320 200 150 110 E32-T14 950 700 300 200 140 100 E32-T11L/ E32-T12L 350 250 120 75 55 40 E32-T11L+ E39-F2 220 160 75 46 32 25 E32-T11R+ E39-F2 110 85 36 22 16 12 E32-T11+ E39-F2 180 140 60 38 28 20 E32-T12L/ E32-T22L 160 120 90 34 24 14 6.5 *Note: These sensing distances are recommended to make the most of the detection capabilities of the Sensor. 41 Ordering Information Through-beam Fiber Units used with E3X-DAC True Color Amplifier Area-sensing Label detection (Slot Sensor) Heat-resistant Chemicalresistant Vacuum-resistant Environment-resistive models Special-beam models Fine beam Type Applicable Fiber Units Sensing distance (mm) with opaque object Sensing distance (mm) with translucent object* High resolution mode Standard mode Super high-speed mode High resolution mode Standard mode Super high-speed mode E32-T22S 500 400 170 110 80 55 E32-T24S 360 280 120 75 55 40 E32-T16 750 600 250 160 110 85 E32-T16PR 240 180 80 50 36 26 E32-T16JR 200 160 65 44 30 22 E32-T16WR 360 280 120 75 55 40 E32-G14 10 10 E32-T51 200 160 70 44 32 22 E32-T54 60 48 20 13 9.5 7 E32-T81R-S 75 60 26 16 11 8.5 E32-T61-S 120 95 42 26 19 14 E32-T61-S + E39-F1 950 700 320 200 140 100 E32-T61-S + E39-F2 120 95 42 26 19 14 E32-T84S-S 360 280 120 75 55 40 E32-T11F 550 420 180 110 80 60 E32-T12F 850 650 280 180 120 95 E32-T14F 100 80 35 22 16 12 E32-T51F 380 300 130 80 55 44 E32-T81F-S 190 150 65 40 28 22 E32-T51V 55 42 18 11 805 6 E32-T51V + E39-F1V 280 200 90 55 42 30 E32-T54V 36 28 12 705 5.5 4 E32-T54V + E39-F1V 140 100 46 28 20 15 E32-T84SV 130 100 45 28 20 15 *Note: These sensing distances are recommended to make the most of the detection capabilities of the Sensor. 42 Fiber Units with Reflective Sensors used with E3X-DAC True Color Detection Long-distance, high-power Coaxial Areasensing Special-beam models Fluorine coating Break-resistant Standard models General purpose Type Applicable Fiber Units Sensing distance (mm) with white paper Sensing distance (mm) with standard color card (11 colors) mutual determination High resolution mode Standard mode Super high-speed mode High resolution mode Standard mode Super high-speed mode E32-DC200 70 54 18 14 10 6 E32-D11R/ E32-D12R/ E32-D15XR/ E32-DC200BR/ E32-DC200B4R 42 32 11 8.5 6 3.5 E32-D14LR/ 11 8.5 2.5 2.4 1.7 1 E32-D15YR/ E32-D15ZR 10 7.5 2.5 2.1 1.5 0.9 E32-D211/ E32-DC200E/ E32-D22/ E32-D25X/ E32-DC200F/ E32-DC200F4 20 16 5 4.5 3 1.5 E32-D24/ 8.8 6.7 2.1 1.8 1.3 0.7 E32-D25Y/ E32-D25Z 5.8 4.5 1.4 1.2 0.9 0.5 E32-D11/ E32-D15XB 42 32 11 8.5 6 3.5 E32-D21B/ E32-D221B 19 15 4.5 4.1 3 1.5 E32-D21/ E32-D22B 8.8 6.7 2.1 1.8 1.3 0.7 E32-D25XB 14 10 3 3 2.1 1.1 E32-D11U 42 32 11 8.5 6 3.5 E32-A09 20 to 38 24 to 36 -- 20 to 38 24 to 36 -- E32-D11L 90 70 22 19 13 7.5 E32-D21L/ E32-D22L 35 26 8 7 5 2.5 E32-CC200 60 45 16 12 9 4 E32-CC200R 35 26 9 7.5 5 3 E32-D32L 35 26 9 7.5 5 3 E32-C31/ E32-D32 17 13 4.5 3.7 2.7 1.5 E32-D36P1 35 26 9 7.5 5 3 43 Ordering Information Fiber Units with Reflective Sensors used with E3X-DAC True Color Detection 44 Heatresistant Chemicalresistant Environment-resistive models Type Applicable Fiber Units Sensing distance (mm) with white paper Sensing distance (mm) with standard color card (11 colors) mutual determination High resolution mode Standard mode Super high-speed mode High resolution mode Standard mode Super high-speed mode E32-D51 55 42 14 11 8.5 4.5 E32-D81R-S/ E32-D61-S 20 15 5 4 3 1.5 E32-D73-S 13 10 3.5 2.8 2 1.2 E32-D12F 22 17 6 4.9 3.5 2 E32-D14F 9 7 2 2.1 1.4 0.6 Accessories *1. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. High-resolution mode Standard mode Super-high-speed mode When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). High-resolution mode Standard mode Super-high-speed mode When used in combination with the E3X-MDA Unit. When used in combination with E3X-NA-F high speed unit. When used in combination with E3X-NA or E3X-SD standard units. Lens Units Type Appearance Applicable Fiber Units Sensing distance (mm) Standard object (min. sensing object) (mm) *1 Features Lens model number 4,000*2 3,200 840 1,100 870 E32-T11L 350 700 210 4,000*2 4,000*2 1,500 4,000*2 3,700 1,500 3,000 900 Long-distance Lens Units Through-beam Lens Units E32-TC200 4,000*2 3,700 970 3,100 2,400 970 2,100 E32-T11R 630 4,000*2 3,600 930 3,000 2,300 930 2,000 E32-T11 4 dia. (0.1 dia.) Long-distance sensing; opening angle: 5 to 40 (heat resistant up to 200C) E39-F1 600 4,000*2 3,700 970 3,100 2,400 970 2,100 E32-T11N 630 4,000*2 3,600 930 3,000 2,300 930 2,000 E32-T11U 600 *2. The optical fiber is 2 m long on each side to permit a total sensing distance of 4,000 mm. 45 Ordering Information Accessories *1. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. High-resolution mode Standard mode Super-high-speed mode When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). High-resolution mode Standard mode Super-high-speed mode When used in combination with the E3X-MDA Unit. When used in combination with E3X-NA-F high speed unit. Type Appearance Applicable Fiber Units When used in combination with E3X-NA or E3X-SD standard units. Sensing distance (mm) Standard object (min. sensing object) (mm) *1 Features Lens model number 2,650 2,100 Long-distance Lens Units 520 1,600 1,300 E32-T81R-S 520 4 dia. (0.1 dia.) Long-distance sensing; opening angle: 5 to 40 (heat resistant up to 200C) E39-F1 3 dia. (0.1 dia.) Side-view, space-saving; opening angle: 20 to 60 (heat resistant up to 200C) E39-F2 1,050 380 4,000*2 3,400 900 3,000 2,200 900 3,000 900 E32-T61-S 910 800 Through-beam Lens Units 180 600 520 E32-T11L 180 500 150 840 700 160 Side-view Units E32-TC200 470 360 140 300 90 520 400 100 E32-T11R 330 260 100 220 65 820 660 160 E32-T11 530 430 160 360 100 *2. The optical fiber is 2 m long on each side to permit a total sensing distance of 4,000 mm. 46 Accessories *1. Sensing distance when operated with E3X-DA-S amplifier *2. Sensing distance when operated with E3X-MDA amplifier *3. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. High-resolution mode Standard mode Super-high-speed mode *When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). High-resolution mode Standard mode Super-high-speed mode *When used in combination with the E3X-MDA Unit. *When used in combination with E3X-NA-F high speed unit. Type Appearance Applicable Fiber Units *When used in combination with E3X-NA or E3X-SD standard units. Sensing distance (mm) *1 Standard object (min. sensing object) (mm) *3 Features Lens model number 820 660 160 530 430 E32-T11U Side-view Units 160 360 100 360 280 E32-T81R-S 70 190 150 60 130 35 3 dia. (0.1 dia.) Side-view, space-saving opening angle: 20 to 60 (heat resistant up to 200C) E39-F2 Long distance reflection (heat resistant up to 200C) E39-F3 600 450 Reflection Units E32-T61-S E32-T11L E32-TC200 E32-T11R E32-T11 E32-T11U E32-T81R-S E32-T61-S E32-C42 E32-D32 Small-spot Lens Units Through-beam Lens Units 120 390 300 120 390 130 -- -- Spot diameter variable in the range 0.1 to 0.6 mm at distances in the range 6 to 15 mm Small spot (variable) Spot diameter variable in the range 0.5 to 1 mm at distances in the range 6 to 15 mm E32-C41 0.1-dia. spot at a distance of 7 mm E32-C31 0.5-dia. spot at a distance of 7 mm E32-C41 0.2-dia. spot at a distance of 17 mm E32-C31 0.5-dia. spot at a distance of 17 mm E32-C31 E32-C41 Spot diameter of 4 mm max. at distances in the range 0 to 20 mm E39-F3A Small spot E39-F3A-5 Long distance, Small spot E39-F3B Long-distance sensing, parallel light E39-F3C 47 Ordering Information Accessories Protective Spiral Tube Appearance Application Applicable Fiber Units Tube length M3-screw models E32-D21 E32-DC200E E32-DC200F E32-C31 M3-screw models E32-T21 (Except the E32-T21R.) E32-TC200E E32-TC200F Fiber protection M4-screw models E32-T11 E32-TC200 E32-TC200B E32-T51 M6-screw models E32-D11 E32-DC200 E32-DC200B E32-CC200 E32-D51 Model number 500 mm E39-F32A5 1m E39-F32A 500 mm E39-F32B5 1m E39-F32B 500 mm E39-F32C5 1m E39-F32C 500 mm E39-F32D5 1m E39-F32D Note: Before using a Protective Spiral Tube, remove the protective tube that protects the area between the head and the optical fiber provided with some models. Other Accessories Appearance Application Used to cut the fiber. Attachments for inserting thin fibers into Amplifier Units Name Applicable Fiber Units Fiber Units that allow free cutting Provided with applicable Fiber Units. E39-F4 Thin-fiber Attachments Fiber Units that allow free cutting and have a 1.0-dia. sheath * 2 per set * Provided with applicable Fiber Units. E39-F9 Fiber Units that allow free cutting and have a 2.2-dia. sheath Fiber Units that allow free cutting Sleeve Bender -- E32-F10 E39-F13: Used for Fiber Units with a 2.2-dia. sheath. Fiber Connectors Easy-to-use, one-touch relay connectors 48 Model number Cutter Used to extend fibers. Used to bends in sleeves. Remarks E32-TC200B(4) E32-TC200F(4) E32-DC200F(4) E39-F14: Used for Fiber E39-F13 Units with a 1.0-dia. sheath. E39-F14 E39-F15: Used for Fiber E39-F15 Units with a sheath diameter between 1.0 and 2.2 mm. -- E39-F11 Ratings/Characteristics Fiber Units Type Standard models Flexible E32-T1 R E32-D1 R E32-T11N E32-D11N E32-C11N E32-C31N Item Ambient operating temperature *1 -40C to 70C Ambient humidity *1 35% to 85% Fiber material Plastic (PVC coating) Standard E32-T2 R E32-D2 R Break-resistant Plastic (PVC coating) Plastic (polyethylene coating) Fluorine-coating Plastic (fluororesin coating) Degree of protection IEC standard: IP67 Type Special-beam models Long-distance, high power Item All other models Ultracompact, ultrafine-sleeve E32-D16 Coaxial, small-spot Ambient operating temperature *1 -40C to 70C Ambient humidity *1 35% to 85% Fiber material Plastic (polyethylene coating) Plastic (PVC coating) Plastic (combination of PVC, polyethylene, and polyolefin sheaths) Degree of protection IEC standard: IP67 IEC standard: IP40 IEC standard: IP67 Type Plastic (PVC coating) Special-beam models Area-sensing Item Fine-beam (narrow vision field) All other models Ambient operating temperature *1 -40C to 70C Ambient humidity *1 35% to 85% Fiber material Plastic (PVC coating) E32-D36P1 E32-T16 E32-ET16WR-1 E32-ET16WR-2 Plastic (polyethylene coating) Retroreflective E32-T16W(R) E32-R21 E32-R16 -25C to 55C -40C to 70C -25C to 55C Plastic (PVC coating) Plastic (polyethylene coating) Degree of protection IEC standard: IP50 (IP67 for E32-T16) Type IEC standard: IP67 IEC standard: IP66 Special-beam models Limited-reflective Item All other models Ambient operating temperature *1 -40C to 70C Ambient humidity *1 35% to 85% Fiber material Plastic (polyethylene coating) E32-L25L E32-L24L -40C to 105C *2 E32-L86 -40C to 200C *3 Glass (SUS spiral coating) Degree of protection IEC standard: IP50 (IP40 for E32-L24S, E32-L16, and E32-L86) *1. There must be no icing or condensation within the range specified for the ambient operating temperature. *2. For continuous operation, use the products within a temperature range of -40C to 90C. *3. The maximum temperature that can be withstood varies with the location. Refer to dimensions diagrams for details. 49 Ratings/Characteristics Fiber Units Type Environment-resistive models Heat-resistant Item E32-T5 E32-D5 E32-T8 R-S E32-D8 R-S Ambient operating temperature *1 -40C to 150C *4 -40C to 200C *3 Ambient humidity *1 35% to 85% Fiber material Plastic (fluororesin coating) E32-T6 -S E32-D6 -S E32-D73-S -60C to 350C *3 -40C to 400C *3 E32-T84S-S Glass (fluororesin coating) Glass (SUS spiral coating) Degree of protection IEC standard: IP67 Type Environment-resistive models Chemical-resistant Item All other models Vacuum-resistant E32-T51F E32-T81F-S -40C to 150C *4 -40C to 200C *3 -25C to 120C -25C to 200C Glass (fluororesin cover) Glass (fluororesin coating) Glass (SUS spiral coating) Ambient operating temperature *1 -40C to 70C Ambient humidity *1 35% to 85% Fiber material Plastic (fluororesin coating) All other models Degree of protection IEC standard: IP67 32-T84SV -- Type Application-specific models Liquid-level detection Item Label-detection All other models Ambient operating temperature *1 -40C to 70C Ambient humidity *1 35% to 85% Fiber material Plastic (polyethylene coating) Degree of protection IEC standard: IP67 Other Wafer-mapping -40C to 70C Fluororesin cover Plastic (polyethylene coating) IEC standard: IP50 IEC standard: IP68 IEC standard: IP50 Repeat accuracy: 1 mm max. Repeat accuracy: 0.5 mm max. Plastic (fluororesin coating) Application-specific models Glass-substrate-alignment All other models Ambient operating temperature *1 -40C to 70C Ambient humidity *1 35% to 85% Fiber material Plastic (polyethylene coating) Glass-subtrate-mapping E32-L66 E32-A09 0C to 300C *3, *5 -40C to 70C -40C to 150C *4 -40C to 300C *3 Glass (SUS spiral coating) Plastic (polyethylene coating) Plastic (fluororesin coating) Glass (SUS spiral coating) Degree of protection IEC standard: IP40 *1. There must be no icing or condensation within the range specified for the ambient operating temperature. *2. For continuous operation, use the products within a temperature range of -40C to 90C. *3. The maximum temperature that can be withstood varies with the location. Refer to dimensions diagrams for details. *4. For continuous operation, use the products within a temperature range of -40C to 130C. *5. These values are based on the assumption that there are no repeated sudden changes in temperature. 50 E32-D82F -40C to 200C *3 Type Item E32-A01 E32-A02 E32-A09H E32-A09H2 Dimensions Through-beam Fiber Units Standard/Flexible Models Indicates models that allow free cutting. E32-TC200 E32-T11R E32-TC200E 1 dia. M2.6 x 0.45 3.2 Two hexagonal nuts Two toothed washers Sensing head: M4 x 0.7* Optical fiber: 2.2 dia. 3 2.4 7 Two hexagonal nuts Two toothed washers Sensing head: M3 x 0.5* Optical fiber: 1 dia. 0.5 dia. 2.5 14 1.8 2,000 Fiber Attachment (E39-F9) 2,000 11 5.5 *Material: Brass/nickel plating *Material: Brass/nickel plating E32-TC200A E32-T21R 1 E32-T22 E32-T22R Two hexagonal nuts Two toothed washers Sensing head: M3 x 0.5*2 Optical fiber: 2.2 dia. dia.*1 1.8 5.5 Heat-shrinkable tube 0.5 dia. 2 dia. Sensing head* 1.4 dia. Optical fiber: 1 dia. 17 3 dia. 25 10 Fiber Attachment (E39-F9) 2,000 *Material: Stainless steel (SUS303) *1. E32-T21R: 0.5 dia. *2. Material: Brass/nickel plating E32-T12 E32-T12R E32-T222 E32-T222R 2.4 dia. Sensing head: 3 dia.* 3 25 Optical fiber: 2.2 dia. Sensing head* 0.5 dia. 11 2,000 E32-T15X E32-T15XR Fiber Attachment (E39-F9) 10 *Material: Brass/nickel plating 10 Optical fiber: 1 dia. 1.5 dia. (14) 2,000 *Material: Brass/nickel plating E32-T25X E32-T25XR Sensing head* 2,000 15 Optical fiber: Two, 2.2 dia. Sensing surface 1 dia. 3 8 1.5 12 Sensing surface: 0.5 2 7 1 2.5 Sensing head* 2.5 7.5 5 E32-TC200(F4) E32-TC200F(F4R) Two hexagonal nuts Two toothed washers Sensing head: M4 x 0.7 (coarse thread) *2 Stainlesssteel tube 1 dia. 1.2 dia. max. (SUS304) 90 (40)*1 2.5 11 2,000 *1. ( ): E32-TC200B4 *2. Material: Brass/nickel plating 25 10 Fiber Attachment (E39-F9) 1.8 90 (40)*1 5.5 E32-T14L E32-T14LR Two hexagonal nuts Two toothed washers Sensing head: M3 x 0.5 *2 Optical fiber: 1 dia. Stainless0.5 dia. 0.9 dia. steel tube (SUS304) max. Optical fiber: 2.2 dia. 2.4 3.2 7 25 *Material: Aluminum Two, 2.2-dia. mounting holes with 4.4-dia. countersinks on both sides *Material: Aluminum E32-TC200B(B4) E32-TC200BR(B4R) 2,000 Optical fiber: 1 dia. Fiber Attachment (E39-F9) 5 4.5 Two, 2.2-dia. mounting holes with 4.4-dia. countersinks on both sides 11 2,000 *1. ( ): E32-TC200F4 *2. Material: Brass/nickel plating E32-T24 E32-T24R Sensing head: 3 dia.* Heat-shrinkable 45 tube Fiber Attachment (E39-F9) Stainless-steel 25 Heat-shrinkable tube tube: 1 dia. Sensing head: 10 2 dia.* 1.4 dia. Optical fiber: 1 dia. 45 Optical fiber: 2.2 dia. 2.8 3 dia. 12 22 2,000 9.5 13.5 1 dia. 25 10 1.5 1 1.5 30 35 12 2,000 1 0.5 1.5 15 15 35 Sensing surface *Material: Stainless steel (SUS304) 12 2,000 *Material: Stainless steel (SUS304) 51 Dimensions Through-beam Fiber Units Standard/Flexible Models Indicates models that allow free cutting. E32-T15Y E32-T15YR E32-T25Y E32-T25YR 4 3 Sensing head* Sensing head* 2 3 Sensing surface 1.5 Sensing surface 2,000 15 2,000 12 1 8 25 Optical fiber: 1 dia. 7 Optical fiber: Two, 2.2 dia. 7.5 5 2.5 *Material: Aluminum Two, 2.2-dia. mounting holes with 4.4-dia. countersinks on both sides E32-T15Z E32-T15ZR Fiber Attachment (E39-F9) 5 4.5 2.5 *Material: Aluminum Two, 2.2-dia. mounting holes with 4.4-dia. countersinks on both sides E32-T25Z E32-T25ZR Sensing surface 15 3 1.5 4 12 Sensing surface 2,000 2 Sensing head* 8 1 2,000 Sensing head* 3 25 Optical fiber: 1 dia. 7 2.5 Optical fiber: 2.2. dia. 7.5 5 Two, 2.2-dia. mounting holes with 4.4-dia. countersinks on both sides *Material: Aluminum 2.5 Fiber Attachment (E39-F9) 5 4.5 Two, 2.2-dia. mounting holes with 4.4-dia. countersinks on both sides *Material: Aluminum Break-resistant/Coated Models E32-T11 E32-T11U E32-T21 Sensing head: Two hexagonal nuts M4 x 0.7* Two toothed washers Sixteen, 0.265 dia. Protective tube M2.6 x 0.45 3.2 2.4 3.3 15 (14) 7 Sensing head: Two hexagonal nuts M3 x 0.5* Two toothed washers Four, 0.25 dia. Protective tube Optical fiber: 1 dia. Optical fiber: 2.2 dia. 2.5 2,000 1.8 15 Fiber Attachment (E39-F9) 2,000 *Material: Brass/nickel plating 11 5.5 *Material: Brass/nickel plating E32-T12B 25 10 E32-T221B Sixteen, 0.265 dia. 2.4 dia. Sensing head: 3 dia.* 3 Heat-shrinkable tube Optical fiber: 1 dia. Optical fiber: 2.2 dia. Four, 0.25 dia. 2 dia. Sensing head* 1.4 dia. 11 (14) 17 2,000 22 *Material: Brass/nickel plating 12 25 10 Fiber Attachment (E39-F9) 2,000 *Material: Stainless steel (SUS303) E32-T22B 25 Four, 0.25 dia. Sensing head* Optical fiber: 1 dia. 1.5 dia. 10 Fiber Attachment (E39-F9) 10 2,000 *Material: Brass/nickel plating E32-T15XB E32-T25XB Sensing head* Sensing surface: 15 Sixteen, 0.265 dia. 3 8 1.5 2,000 Optical fiber: 2.2 dia. 7 1 2.5 7.5 5 Two, 2.2-dia. mounting holes with 4.4-dia. countersinks on both sides 52 Sensing surface: Four, 0.25 dia. 2 *Material: Aluminum 2,000 12 Sensing head* 2.5 5 4.5 Two, 2.2-dia. mounting holes with 4.4-dia. countersinks on both sides Optical fiber: 1 dia. 25 Fiber Attachment (E39-F9) *Material: Aluminum Through-beam Fiber Units Right angle Models E32-T11N 8.4 dia. Model display tube Optical fiber, 2.2 dia. 5.5 7 7 Sensing head (brass/nickel plating) 3 10 1 4.7 1.5 2,000 (standard length) (45) M4 x 0.7 M2.6 x 0.45 1 dia. (sensing surface) Four, M4 nuts and washers provided. Long-distance/High-power Models E32-T17L E32-T14 Sensing head: M14 x 1* Two hexagonal nuts Heat-resistant ABS Nitrile rubber Lens (PMMA) 4.4 dia. 8.2 Lens: 10 dia. (PMMA) Optical fiber: 2.2. dia. 8 7.6 Optical axis R3.5 5 19 10.5 Two, 3.2 dia. Optical fiber: 2.2 dia. 7 8 23 42 100.2 2.5 10,000 9.2 *Material: ABS E32-T11L 16 11.2 2,000 E32-T12L 1.4 dia. M2.6 x 0.45 Two hexagonal nuts Two toothed washers Sensing head: M4 x 0.7* 2.4 dia. Sensing head: 3 dia.* 1.4 dia. Optical fiber: 2.2. dia. 3 3.2 3 7 11 (14) 11 (14) Optical fiber: 2.2. dia. 2,000 *Material: Brass/nickel plating 2,000 *Material: Brass/nickel plating E32-T21L E32-T22L Two hexagonal nuts Two toothed washers Sensing head: M3 x 0.5* Optical fiber: 1 dia. 0.9 dia. 25 0.9 dia. 10 1.8 dia. Sensing head: 2 dia.* Heat-shrinkable tube Optical fiber: 1 dia. (2) (1.7) 2.5 Fiber Attachment (E39-F9) 1.8 11 5.5 17 22 2,000 25 10 Fiber Attachment (E39-F9) 12 2,000 *Material: Stainless steel *Material: Brass/nickel plating Ultracompact/Thin-sleeve Models E32-T223R E32-T33-S5 10 2,000 1 dia. 25 (0.5) Optical fiber: 1 dia. 0.5 dia. 1,000 20 25 0.25 dia. 5 10 12 Optical fiber: 1 dia. 10 0.5 dia. Sensing head* Fiber Attachment (E39-F9) *Material: Stainless steel 3 dia. Sensing head* Heat-shrinkable tube Fiber Attachment (E39-F9) *Material: Stainless steel 53 Dimensions Through-beam Fiber Units Ultracompact/Thin-sleeve Models Indicates models that allow free cutting. E32-T333-S5 E32-T334-S5 20 1,000 20 1,000 25 0.125 dia. 5 10 Optical fiber: 1 dia. 12 25 10 0.25 dia. 3 dia. Heat-shrinkable tube Sensing head* Fiber Attachment (E39-F9) 0.1 dia. 5 10 Optical fiber: 1 dia. 12 0.22 dia. 3 dia. Heat-shrinkable tube Sensing head* Fiber Attachment (E39-F9) *Material: Stainless steel Note: The Fiber Attachment is attached with adhesive and cannot be removed. 10 *Material: Stainless steel Note: The Fiber Attachment is attached with adhesive and cannot be removed. Fine-beam (narrow vision field) Models E32-T22S E32-T24S Sensing surface Sensing head* 1.7 dia. Optical fiber: 2.2 dia. 1 2.5 Sensing head: 3 dia.* Optical fiber: 2.2 dia. 2 dia. 45 3 dia. 15 1.7 2,000 25 *Material: Brass/nickel plating 20 2,000 45 *Material: Stainless steel (SUS303) Area-sensing Models E32-M21 E32-T16W E32-T16WR 5 23 18 Sensing surface (3 x 30) 12 18.5 Sensing head: M3 x 0.35 *2 Two hexagonal nuts Two toothed washers Silicon tube *1 Four, 1-dia. plastic fibers Optical axis 45 65 69 *1. One set of silicon tubes is black and the other set is gray. Use this difference to distinguish between the emission and reception sides. *2. Material: Stainless steel (SUS303) Sleeve 13 28 Sensing head* 1.8 Two, 3.2-dia. mounting holes with 6-dia. countersinks 11 2,000 23 Optical fiber: 2.2 dia. 2,000 *Material: ABS 54 Through-beam Fiber Units Area-sensing Models E32-ET16WR-1 E32-ET16WR-2 E32-T16P E32-T16PR E32-T16J E32-T16JR Two, 3.2 dia. 15.5 8.85 Receiver 14.5 10.7 6-dia. countersink E32-T16 Sensing surface (2 x 11) 4 Optical axis 3.3 14.5 10.7 19 27 20 2 Sensing surface (2 x 11) Sensing head*1 27 * Two, 3.2-dia. holes with 6-dia. countersinks 20 Lens (2 x 10) (PMMA) 20 6 dia. 4 Sensing head* 25 27 19 4 Optical axis 4 Optical axis Sensing surface (2 x 11) 8.4 3 Emitter Two, M3 Sensing head* 2,000 Optical fiber: 2.2 dia. 2000 2,000 Optical fiber: 2.2 dia. Optical fiber: 2.2 dia. *1. Material: Heat-resistant ABS *2. Provided with stickers with slits of width 0.5 and 1 mm (2 of each). *Material: ABS for the sensing head and PMMA for the prism. *1. Material: Heat-resistant ABS *2. Provided with stickers with slits of width 0.5 and 1 mm (2 of each). Heat-resistant Models E32-T51 E32-T54 Two hexagonal nuts Two toothed washers Sensing head: M4 x 0.7* Optical fiber: 2.2 dia. 1.5 dia. Sensing surface 1 2.5 Sensing head: 3 dia.* Optical fiber: 2.2 dia. 2 dia. 45 7 2.85 dia. 1 1.7 2.4 15 17 25 2,000 *Material: Brass/nickel plating Note: The maximum allowable temperature is 150C. The maximum allowable temperature for continuous operation is 130C. 20 45 2,000 *Material: Stainless steel (SUS303) Note: The maximum allowable temperature is 150C. The maximum allowable temperature for continuous operation is 130C. 55 Dimensions Through-beam Fiber Units Heat-resistant Models Indicates models that allow free cutting. E32-T81R-S Two hexagonal nuts Two toothed washers Sensing head: M4 x 0.7 *1 M2.6 x 0.45 Protective tube 3.6 dia. 2 dia. Fluororesin tube 4 dia. Sleeve 2.2 dia. *1. Material: Stainless steel (SUS303) 0.7 dia. 5 (75) 7 13 *2 4 dia. 2.4 3 20 25 10 2,000 B A Note: The maximum allowable temperature for section A and B are 200C. and 110C, respectively. The section inserted into Amplifier unit (indicated by *2), however, must stay within the Amplifier Unit's operating temperature range. E32-T84S-S E32-T61-S A (14.2) 12 5 2,000 25 1 dia. 13 *2 R5 3 dia. 4 dia. Flexible tube: 2.9 dia. (stainless steel) 90 30 max. 6 4 dia. Sleeve 2.2 dia. 7 Antislip tread 4 dia. *3 3 20 2.4 2,000 A 25 B *1. Material: Stainless steel (SUS303) *3. The diameter is 6 mm if the fiber length exceeds 10 m. Sensing head *1 Note: The maximum allowable temperature for section 3 dia. A and B are 200C. and 110C, respectively. The Note: The maximum allowable temperature for section A and B are 200C. and 110C, respectively. The section inserted into Amplifier unit (indicated by *2), however, must stay within the Amplifier Unit's operating temperature range. section inserted into Amplifier unit (indicated by *2), however, must stay within the Amplifier Unit's operating temperature range. Lens (2 dia.) 13 *2 5 10 *1. Material: Stainless steel (SUS303) 3.5 dia. 12 Flexible tube: 2.8 dia. (stainless steel) Two hexagonal nuts Hexagonal caulking Two toothed washers 4 dia. Sleeve 2.2 dia. M2.6 x 0.45 Sensing head: M4 x 0.7 *1 B Chemical-resistant Models E32-T11F E32-T12F Lens: 3 dia. Sensing head *1 Nut *1 Optical fiber: 2.2 dia. *2 Sensing head: 5 dia. Fluororesin 4 dia. (10 R3.6 .7) 19.8 (35) 3 4.5 10 2,000 Optical axis (21) 2,000 *1. Material: PFA *2. Sheath material: Fluororesin E32-T14F Lens: 4 dia. Sensing head: 5 dia. 100 E32-T51F 2,000 Fluororesin 4 dia. Optical fiber: 2.2 dia. 100 (20) Lens: 3.7 dia. 20 2,000 Fluororesin 100 Sensing head: 5 dia. E32-T81F-S 6 dia. PFA cover (R6) Protective tube PFA tube 2 dia. 4 dia. Sleeve 13 3.7 dia. (70) (0.8) 30 *2 2,000 5 A Note: The maximum allowable temperature for section A and B are 200C. and 110C, respectively. The section inserted into Amplifier unit (indicated by *2), however, must stay within the Amplifier Unit's operating temperature range. 56 Optical fiber: 2.2 dia. 7.2 dia. 10 25 B 2.2 dia. Optical fiber: 2.2 dia. Through-beam Fiber Units Vacuum-resistant Models E32-T51V E32-T54V 1.15 dia. M4 x 0.7 * 1.15 dia. M2.6 x 0.45 8 Two nuts Two spring washers 4 dia. 4 dia. Optical fiber: 3 dia. M2.6 x 0.45 3 2.2 dia. 4.5 Connected to flange (vacuum side) 26 3 20 (30) 18 4 12 (15) 1,000 3 dia. * R9 4 5 dia. 4 dia. 3 dia. 4 dia. 2.2 dia. 1,000 *Material: Aluminum (3) 26 Connected to flange (vacuum side) *Material: Stainless steel (SUS304) E32-T84SV E39-F1V Lens (2 dia.) Sensing head: 3 dia.* (14.2) 12 1,000 0.5-dia. hole 8.9 12 30 max. 6 4 dia. 3.5 dia. R5 3 dia. 90 Flexible tube (stainless steel): 2.9 dia. 4 dia. 4 dia. M2.6 x 0.45 Effective depth: 3.8 Spot-facing depth: 0.9 6 2.2 dia. 26 Connected to flange (vacuum side) *Material: Stainless steel (SUS304) E32-VF4 E32-VF1 Four, 10 dia. 49 36 dia. 24 8 80 70 dia. 44 dia. (96) (63) 45 22 10 5 (23) 22 30 20 dia. 19 80 6 (33.53) Flange V40 O-ring Flange 90 dia. Note 1. Perform mounting so that the V15 O-ring is on the atmospheric-pressure side of the vacuum chamber wall. 2. Mounting-hole cutout dimensions: 14.5 dia. 0.2 mm One nut M14 x 2 Two, connectors One spring V15 O-ring washer Note 1. Perform mounting so that the V15 O-ring is on the atmospheric-pressure side of the vacuum chamber wall. 2. Mounting-hole cutout dimensions: 14.5 dia. 0.2 mm 57 Dimensions Fiber Units with Reflective Sensors Standard/Flexible Models E32-DC200 E32-D11R Two, 1 dia. Two hexagonal nuts Two toothed washers Sensing head* M6 x 0.75 4 dia. 3 4.8 10 Indicates models that allow free cutting. E32-D211 E32-D211R Optical fiber: Two, 2.2 dia. 3.2 2.4 17 Two Fiber Attachments (E39-F9) Two hexagonal nuts 25 Two toothed washers 10 Sensing head: M4 x 0.7* Optical fiber: Two, 1 dia. Two, 0.5 dia. 3 2.4 15 7 2,000 2,000 *Material: ADC E32-DC200E E32-D21R *Material: Stainless steel (SUS303) Two Fiber Attachments (E39-F9) Two hexagonal nuts 25 Two toothed washers 10 Sensing head: M3 x 0.5* Optical fiber: Two, 1 dia. Two, 0.5 dia. 2.5 1.8 5.5 2,000 11 *Material: Stainless steel (SUS304) E32-D12 E32-D12R E32-D22 E32-D22 R Two Fiber Attachments (E39-F9) 25 Optical fiber: 10 2.7 dia. Sensing head: 3 dia.* Two, 1 dia. 2,000 Two, 3 dia. 1 dia. 15 135 Sensing head* Heat-shrinkable tube Two, 0.5 dia. 3 Optical fiber: Two, 2.2 dia. *Material: Stainless steel (SUS304) 15 2,000 *Material: Brass/nickel plating E32-D15X E32-D15XR E32-D25X E32-D25XR 15 Sensing head* 10 2.5 12 2,000 Sensing surface: Two, 1 dia. 3 Optical fiber: Two, 2.2 dia. *Material: Aluminum E32-DC200B(B4) E32-DC200BR(B4R) Stainless-steel tube (SUS304) 2.5 dia. max. Two hexagonal nuts Two toothed washers Sensing head: M6 x 0.75 Optical fiber: Two, 2.2 dia. (fine thread) *2 Sensing surface: Two, 0.5 dia. Two, 2.2-dia. mounting 5 4.5 holes with 4.4-dia. countersinks on both sides 17 Two Fiber Attachments (E39-F9) Two hexagonal nuts 25 StainlessTwo toothed washers 10 Sensing head: M3 x 0.5 *2 Two, 0.5 dia. 1.2 dia. steel tube max. (SUS304) Optical fiber: Two, 1 dia. 2,000 *1. ( ): E32-DC200B4 *2. Material: Brass/nickel plating E32-D14L E32-D14LR 1.8 90 (40)*1 5.5 2,000 11 *1. ( ): E32-DC200F4 *2. Material: Stainless steel (SUS304) E32-D24 E32-D24R Sensing head* 45 Heat-shrinkable tube Stainless-steel tube: 2 dia. Sensing head: 3 dia.* Heat-shrinkable tube 45 Optical fiber: Two, 2.2 dia. 5.7 1.5 1 0.5 2 30 35 12 2,000 Light baffle Sensing surface *Material: Aluminum 2.5 2.4 1 Two Fiber Attachments (E39-F9) E32-DC200F(F4) E32-DC200FR(F4R) 90 (40)*1 6 dia. 2.5 8 1.5 2.5 5.2 10 25 2 7.5 5 Two, 2.2-dia. mounting holes with 4.4-dia. countersinks on both sides Two, 1 dia. 2,000 Optical fiber: Two, 1 dia. Sensing head* Light baffle Two Fiber Attachments (E39-F9) 25 10 Optical fiber: Two, 1 dia. 1.5 15 15 35 Sensing surface 12 2,000 *Material: Stainless steel (SUS304) *Material: Stainless steel (SUS304) 58 Fiber Units with Reflective Sensors Standard/Flexible Models E32-D15Y E32-D15YR E32-D25Y E32-D25YR 2.8 2.4 2.3 3 1.4 2 Sensing surface 15 Sensing head* Sensing surface 12 Two, 2.2-dia. mounting holes with 4.4-dia. countersinks 1.5 2,000 2.5 Optical fiber: Two, 2.2 dia. 10 Sensing head* 2,000 Optical fiber: Two, 1 dia. Two Fiber Attachments (E39-F9) 8 2.5 7.5 5 Two, 2.2-dia. mounting holes with 4.4-dia. countersinks on both sides 2.5 *Material: Aluminum E32-D15Z E32-D15ZR 25 5 4.5 *Material: Aluminum E32-D25Z E32-D25Z 15 Sensing head* 2.2 1.4 3 12 Sensing head* Sensing surface 2,000 Sensing surface Optical fiber: Two, 2.2 dia. 2 4 1.2 0.9 2,000 Optical fiber: Two, 1 dia. Two Fiber Attachments (E39-F9) 8 10 2.5 2.5 7.5 5 Two, 2.2-dia. mounting holes with 4.4-dia. countersinks on both sides *Material: Aluminum 25 3 5 4.5 *Material: Aluminum Two, 2.2-dia. mounting holes with 4.4-dia. countersinks Break-resistant/Coated Models E32-D11 E32-D11U Two, sixteen, Two hexagonal nuts 0.265 dia. Sensing head: Two toothed washers Protective tube M6 x 0.75* 2.4 5.2 10 Optical fiber: Two, 2.2 dia. 15 17 2,000 *Material: Brass/nickel plating E32-D21B E32-D21 Two Fiber Attachments (E39-F9) Two hexagonal nuts 25 Two toothed washers 10 Sensing head: M4 x 0.7* Optical fiber: Two, 1 dia. Two, four, 0.25 dia. 3.2 3 2,000 Material: Stainless steel (SUS303) E32-D221B Two, four, 0.25 dia. 1.8 2.5 2.4 15 7 Two hexagonal nuts Sensing head: Two toothed washers Four, 0.25 dia. M3 x 0.5* Protective tube Two Fiber Attachments (E39-F9) 25 10 Optical fiber: Two, 1 dia. 15 11 5.5 2,000 *Material: Brass/nickel plating E32-D22B Two Fiber Attachments (E39-F9) 25 Sensing head: 10 2.7 dia. 3 dia.* Optical fiber: Two, 1 dia. Attachment 25 Four, 0.25 dia. Sensing head *1 Optical fiber: Brancher (ABS): 3 dia. 1 dia. 1.5 dia. 3 15 15 15 2,000 *Material: Brass/nickel plating 10 2,000 100 *1. Material: Stainless steel (SUS304) Note: The Attachment is attached with adhesive Note: The Attachment is attached with adhesiveand andcannot cannotbeberemoved. removed. 59 Dimensions Fiber Units with Reflective Sensors Break-resistant/Coated Models Indicates models that allow free cutting. E32-D15XB E32-D25XB Sensing head* 15 10 2.5 12 2,000 Sensing surface: Two, sixteen, 0.265 dia. 3 2,000 Optical fiber: Two, 1 dia. Sensing head* Optical fiber: Two, 2.2 dia. 25 2 Two Fiber Attachments (E39-F9) 8 1.5 2.5 Sensing surface: Two, four, 0.25 dia. Two, 2.2-dia. mounting 5 4.5 holes with 4.4-dia. countersinks *Material: Aluminum 7.5 5 Two, 2.2-dia. mounting holes with 4.4-dia. countersinks on both sides 2.5 *Material: Aluminum Right angle Models E32-D11N E32-C11N 2,000 (standard length) Model display tube Optical fiber, 2.2 dia. 3 (45) 151, 0.0075 dia. (emitting fiber) Sixteen, 0.265 dia. (receiving fiber) 1 2,000 (standard length) Model display tube Optical fiber, 2.2 dia. Two, 1-dia. (sensing surface) Sensing head (brass/nickel plating) M6 x 0.75 (45) 12 dia. 18 10 10 8 8 10 1.5 10 1.5 6 4.7 1 11 Sensing head (brass/nickel plating) M6 x 0.75 12 dia. Two, M6 nuts and washers provided. Two, M6 nuts and washers provided. E32-C31N 0.5 dia. (emitting fiber) Model display tube 0.5 10 25 1 13.5 Sensing head (brass/nickel plating) M3 x 0.5 2.2 dia. 2,000 (standard length) Optical fiber, two, 1-dia. (45) 3.6 dia. Four, 0.25-dia. (receiving fiber) 7 2.5 Note: The emitting fiber is indicated by a white line. 5 5.5 6.5 dia. Two, M3 nuts and washers provided. Long-distance/High-power Models E32-D16 Two, 5.8-dia lenses E32-D11L 22 9 11 6.5 2,000 Two, 1.4 dia. 8.5 4 dia. Two hexagonal nuts Two toothed washers Sensing head: M6 x 0.75* 17.5 Optical axis Optical axis Sensing head* Two, 3.2-dia. mounting holes with 6-dia. countersinks Optical fiber: Two, 2.2 dia. 3.2 2.4 3 20 2,000 *Material: Brass/nickel plating E32-D22L Two Fiber Attachments (E39-F9) Two hexagonal nuts 25 Two toothed washers 10 Sensing head: M4 x 0.7* Optical fiber: Two, 1 dia. Two, 0.9 dia. 7 5.2 10 *Material: Aluminum E32-D21L 60 Optical fiber: Two, 2.2 dia. 3 3 2.4 15 Two Fiber Attachments (E39-F9) 25 10 Sensing head: Optical fiber: Two, 1 dia. Two, 0.9 dia. 2.7 dia. 3 dia.* 2,000 *Material: Brass/nickel plating 15 2,000 *Material: Brass/nickel plating Fiber Units with Reflective Sensors Ultracompact/Thin-sleeve Models E32-D331 E32-D33 Attachment Stainless-steel tube: 0.8 dia. Sensing head: 3 dia.* Two, 0.25 dia. Heatshrinkable tube Two Fiber Attachments (E39-F9) 25 10 Optical fiber: Two, 1 dia. Stainless-steel tube: 0.5 dia. Two, 0.125 dia. 25 Irraxtube: 1.2 dia. Sensing head: 2 dia. *1 Brancher: 3.5 dia. 10 15 15 15 12 15 2,000 35 *Material: Stainless steel (SUS303) 15 2,000 100 *1. Material: Stainless steel (SUS303) Note: The Attachment is attached with adhesive Note: The Attachment is attached with adhesive and cannot be removed. and cannot be removed. Coaxial/Small-spot Models E32-CC200 E32-CC200R E32-D32L Sixteen, 0.25-dia. reception Emission fiber: fibers 1 dia. 2.5 dia. 5.2 10 3 Two hexagonal nuts Two toothed washers Sensing head: M6 x 0.75* Optical fiber: Two 2.2 dia. 2,000 Emission fiber: 1 dia. 15 Sensing head: 3 dia.* Sixteen, 0.265-dia. reception fibers 2.4 23 400 15 Brancher (heat-resistant, ABS, black): 6 dia. 2,000 1,570 Optical fiber: Two 2.2 dia. *Material: Stainless steel (SUS304) *Material: Brass/nickel plating Note: There is a white line on the fiber that is inserted in the emitter-side port. Note: There is a yellow dotted line on the fiber that is inserted in the emitter-side port. E32-C31 E32-D32 Two Fiber Attachments (E39-F9) 25 Two hexagonal nuts Optical fiber: 10 Emission fiber: Sensing head: Two toothed washers M3 x 0.5* Heat-shrinkable tube Two, 1 dia. 0.5 dia. Four, 0.25-dia. reception 2.5 fibers 20 12 25 2,000 *Material: Brass/nickel plating Note 1. There is a white line on the fiber that is inserted in the emitter-side port. 2. The core diameter of the sensing head is assumed to lie in the range 2.44 to 2.49 mm. Sensing head: 2 dia.* 3 dia. Emission fiber: 0.5 dia. 15 Four, 0.25-dia. reception fibers 22 2 Heat-shrinkable tube Two Fiber Attachments (E39-F9) 25 10 Optical fiber: Two, 1 dia. 12 2,000 *Material: Stainless steel (SUS303) Note: There is a white line on the fiber that is inserted in the emitter-side port. E32-C41 1 x 0.175 dia. (emission fiber) Two toothed Two hexagonal washers nuts Irraxtube: 2.6 dia. 6 x 0.175 dia. (reception fibers) Fiber White markings: Attachment Optical fiber: Emission side Two, 1.2 dia. (heat-shrinkable tube) 15 1.8 Sensing head: M3 x 0.5* Brancher (ABS resin): 3.5 dia. (5) 10 (100) 17 25 1,000 22 *Material: Stainless steel (SUS303) Note: The Attachment is attached with adhesive and cannot be removed. E32-C42 1 x 0.175 dia. (emission fiber) 6 x 0.175 dia. (reception fibers) Brancher (ABS resin) Sensing head: 2 dia.* 3 dia. 15 2 Irraxtube: 2.6 dia. White markings: Two Fiber Attachments Emission side (heat-shrinkable tube) Optical fiber: Two, 1.2 dia. 15 (5) (100) 10 25 1,000 22 *Material: Stainless steel (SUS303) Note: The Attachment is attached with adhesive and cannot be removed. 61 Dimensions Fiber Units with Reflective Sensors Area-sensing Models Indicates models that allow free cutting. E32-D36P1 25 2,000 5 10 Optical fiber: Two, 2.2 dia. 15 Two, 3.2-dia. mounting holes 2 10.85 32 x 0.265 dia. (emission and reception fibers in alternating arrangement) 5 Sensing head* *Material: Brass/nickel plating Retroreflective Fiber Models E32-R21 (An E39-R3 Reflector is provided as an accessory.) E32-R16 (An E39-R1 Reflector is provided as an accessory.) 27 15 7 Two Fiber Attachments Two hexagonal nuts Lens Two washers Silicon tube (PMMA) Sensing head* M6 x 0.75 Optical fiber: Two, 1 dia. 5 dia. 25 10 10 7.2 2.2 10 3 2.8 11 17.8 21.5 (6) 16 4 Sensing head *1 8 15.2 14 2,000 Optical fiber: Two, 2.2 dia. Standard length: 2 m *Material: ABS 27.8 Lens (PMMA) Two, M3 set screws (provided) *1. Material: ABS Limited-reflective Models E32-L24S E32-L16 22.5 Two, 3.2-dia. mounting holes with 6-dia. countersinks on both sides 14 3.5 7 Optical fiber: Two, 2.2 dia. 4 2,000 Optical fiber: Two, 1 dia. 3.5 25 10 12.3 9 17.5 3.6 dia. 11 2.2 dia. 2 Optical axis 2.5 2,000 11 4.5 2.5 Sensing head* 2 Optical axis 1 0.75 *Material: ABS Two, 3.2-dia. mounting holes with 6-dia. countersinks on both sides *Material: ABS Sensing head* 3.8 Two Fiber Attachments (E39-F9) 1.7 E32-L24L E32-L25L Sensing distance 4 3.6 3.3 Two, 3.2-dia. lenses Two, 3.2-dia. lenses 1.5 3.3 20 18 4 Optical axis 4 Side-view prism (PC) 25 6.5 Optical fiber: Two, 1 dia. 10 Two Fiber Attachments (E39-F9) 25 6 Two Fiber Attachments (E39-F9) 6 Sensing distance 18 16 6.5 Optical fiber: Two, 1 dia. 10 Sensing head* Two, 3.2-dia. mounting holes with 6-dia. countersinks on both sides Sensing head* Two, 3.2-dia. mounting holes with 6-dia. countersinks on both sides 2,000 *Material: Polycarbonate *Material: Polycarbonate 62 2,000 Fiber Units with Reflective Sensors Limited-reflective Models E32-L25 E32-L25A 20 10 5 20 10 4 5 Sensing distance 4.8 Sensing distance 4 6.5 20 6.5 4.8 Optical fiber: Two, 2.2 dia. 6.5 20 6.5 Sensing head* Two, 3.2-dia. holes with 6-dia. countersinks Sensing head* 2,000 Two, 3.2-dia. holes with 6-dia. countersinks 2,000 *Material: Heat-resistant ABS Optical fiber: Two, 2.2 dia. *Material: Heat-resistant ABS Note: There is a white line on the fiber that is inserted in the emitter-side port. Note: There is a white line on the fiber that is inserted in the emitter-side port. E32-L86 A Optical axis Two, 4 dia. 8.9 B 2,000 33.5 19 11 7 25 5 (max.) 13 18 27 5.5 4 dia. Two, 3.2-dia. holes with 6-dia. countersinks on one side Sensing head (stainless steel) Flexible tube: 2.8 dia.* *Material: Stainless steel Note: The maximum allowable temperature for section A and B are 200C. and 110C, respectively. The section inserted into Amplifier unit (indicated by *2), however, must stay within the Amplifier Unit's operating temperature range. Heat-resistant Models E32-D51 Two hexagonal nuts Two toothed washers Sensing head: M6 x 0.75* Two, 1.5 dia. Optical fiber: Two, 2.2 dia. 4.9 3.1 2.4 3 10 13 17 2,000 *Material: Brass/nickel plating Note: The maximum allowable temperature is 150C. The maximum allowable temperature for continuous operation is 130C. E32-D81R-S E32-D81R Using the E32-D81R-S Fiber: 1.2 dia. M4 x 0.7 Two toothed washers (SUS) Two hexagonal nuts (SUS) Sensing head: M6 x 0.75 *1 SUS flexible tube Protective tube (gray) (4.2 dia.) 5 dia. Using the E32-D81R SUS303 2.2 dia. Sleeve 2.2 dia. Sleeve 5 dia. 4.5 8.5 3 8 15 3 2 20 5 5 (70) 2,000 11.5 15 B 10 *2 5 A 6.5 5 16.5 13 *2 6.4 B *1. Material: Stainless steel (SUS303) Note: The maximum allowable temperature for section A and B are 200C. and 110C, respectively. The section inserted into Amplifier unit (indicated by *2), however, must stay within the Amplifier Unit's operating temperature range. 63 Dimensions Fiber Units with Reflective Sensors Heat-resistant Models E32-D61-S E32-D61 1.4 dia. M4 x 0.7 Indicates models that allow free cutting. Two hexagonal nuts Two toothed washers Sensing head: M6 x 0.75 *1 5 dia. *3 3.5 dia. Using the E32-D61-S Using the E32-D61 SUS flexible tube SUS316L Sleeve Hexagonal caulking 5 dia. 2.2 dia. Sleeve 5 dia. 4.5 8.5 10 3 2 20 2.4 3 2,000 5 *4 11.5 15 5 A 8 5 10 *2 5 B *2 13 6.5 16.5 15 6.4 B *1. Material: Stainless steel (SUS303) *3. The diameter is 6 if the fiber length exceeds 10 m. *4. The diameter is 10 if the fiber length exceeds 10 m. Note: The maximum allowable temperature for section A and B are 200C. and 110C, respectively. The section inserted into Amplifier unit (indicated by *2), however, must stay within the Amplifier Unit's operating temperature range. E32-D73-S E32-D73 1 dia. Using the E32-D73-S Two hexagonal nuts Two toothed washers SUS flexible tube Sensing head: M4 x 0.7 *1 5 dia. 4 dia. 2.8 dia. Stainless-steel tube: 1.25 dia. 1.65 dia. 2.5 dia. Using the E32-D73 Hexagonal caulking 5 dia. 2.2 dia. Sleeve SUS316L Sleeve 4.5 8.5 7 5 5 2.4 5 60 20 10 A 2,000 B 11.5 5 10 *2 8 5 15 16.5 C 6.5 *2 13 6.4 C *1. Material: Stainless steel (SUS303) Note: The maximum allowable temperature for section A and B are 200C. and 110C, respectively. The section inserted into Amplifier unit (indicated by *2), however, must stay within the Amplifier Unit's operating temperature range. Chemical-resistant Models E32-D12F E32-D14F 2,000 (26) Sensing head: 6 dia. Fluororesin 5 dia. Optical fiber: Two, 2.2 dia. 16 2,000 64 100 4.5 Optical Sensing head: 7 dia. axis Optical-axis mark 100 Fluororesin tube (protective cover) Optical fiber: 2.2 dia. 15 Application-specific Fiber Units Label-detection Models E32-G14 36.3 2,000 25.2 20 Sensing head* 9.2 R1.6 R1.6 R3.5 24 Lens (PMMA) 3.2 10 Optical axis 4 1.6 1.6 23.5 8.4 8 9.4 9 Optical fiber: Two, 2.2 dia. 7.6 *Material: ABS Liquid-level Detection Models E32-D36T 2,000 23.45 11.4 (100) 4 15 R10 5 5 2 5 20.4 Eight, R0.5 Optical fiber: Two, 2.2 dia. 13.25 Emission side: Sixteen, 0.265 dia. Sensing head 4.4 Thirty-two, 0.265 dia.* Reception side: Sixteen, 0.265 dia. E32-L25T 2.8 Two, 3.2-dia. lenses (PC) 1.2 Two Fiber Attachments (E39-F9) 25 16 10 (13) 15.2 4 Optical fiber: Two, 1 dia. Mounting hole 6 Sensing head (PC) 6 18 E32-A01 2,000 E32-A02 Sensing head* Sensing head* 14.5 4.5 3.3 1.7 Tube holder Sensing surface (2 x 11) 20 Optical axis 4.2 27 7 5,000 Tube holder Receiver 19.9 *Material: ABS for the sensing head, PMMA for the prism, and PBT for the pipe holder. Sensing surface (2 x 11) 21 5 3 4.5 Optical axis 12 27 5,000 *Material: ABS for the sensing head, PMMA for the prism, and PBT for the pipe holder. Emitter 65 Dimensions Application-specific Fiber Units Liquid-level Detection Models Indicates models that allow free cutting. E32-D82F1 E32-D82F2 Sensing head (fluororesin): 6 dia. Fiber connector (brass/nickel plating): 9 dia. 8 dia. Optical fiber: Two, 2.2 dia. *2 To the Amplifier Unit 27 Length of unbendable section: 150 (350) *1 7.2 42 2,000 2,000 *1. ( ): E32-D82F2 *2. The 2-m section of optical fiber on the Amplifier-unit side is plastic and therefore allows free cutting. Models for Glass-substrate Alignment/Mapping E32-L66 E32-A08 E32-A07E1(E2) 21.7 1 14 B 2,000 25 5 7 13 *2 2,000 24.5 10.7 6.5 3.8 A 11 Reception fiber: 2.2 dia. 18 2.2 dia. 12 1.1 Two, 3.24-dia. mounting holes with 6-dia. countersinks Optical axis Two, 3.2-dia. mounting holes with 6-dia. countersinks Emission fiber: 2.2 dia. 4 dia. *1. Material: Stainless steel (SUS303) Sensing head *1 5.5 36 5 Two, 2.8-dia. flexible tubes (stainless steel) Note: The maximum allowable temperature for section A and B are 200C. and 110C, respectively. The section inserted into Amplifier unit (indicated by *2), however, must stay within the Amplifier Unit's operating temperature range. E32-A09H2 E32-A09 E32-A09H A Optical 9 axis Optical axis 5 Two, 3.24-dia. mounting holes with 6-dia. countersinks 2,000 23 9 28 13 *2 2.8-dia. flexible tubes* 8.9 24 2.2 dia. Optical fiber: Two, 2.2 dia. 8.9 20 Lens: 5.8 dia. B 2,000 30 12 7 Lens: 5.8 dia. 12 7 Two, 3.2-dia. mounting holes with 6-dia. countersinks *Material: Aluminum Sensing head* Sensing head *1 5 dia. 4 dia. *1. Material: Stainless steel Note: The maximum allowable temperature for section A and B are 200C. and 110C, respectively. The section inserted into Amplifier unit (indicated by *2), however, must stay within the Amplifier Unit's operating temperature range. Wafer-mapping Models E32-A03 0.4 E32-A03-1 2,000 20.5 1.8 Two, R1.6 25 2,000 24.5 3.2 Stamp (1-mm dia.) 18.5 3 dia. 10 Optical fiber: 1 dia. 10 25 4.3 17.6 11 3 dia. 3.4 Sensing head *1 R1.6 2 Fiber Attachment (E39-F9) 66 10 3 3.2 E39-L83 Mounting Bracket (SUS) Sensing surface 10 *Material: Brass/nickel plating 2 dia. 4.5 Sensing surface 3.5 13 2 dia. 6.5 3 12.5 Engraved mark: 1 dia. Two, 3.4 dia. Fiber Attachment (E39-F9) Sensing head * *Material: Brass/nickel plating Application-specific Fiber Units Wafer-mapping Models Note: Use the stamped surface and its opposing surface as installation (reference) surfaces. Note: Use the stamped surface and its opposing surface as installation (reference) surfaces. E32-A04 E32-A04-1 Four, R1.35 4 25 2,000 20.5 Stamp (1-mm dia.) Optical fiber: 1 dia. 10 21 2 dia. 2 25 2 2 dia. 2 2 Sensing head * Fiber Attachment (E39-F9) 1.2 dia. *Material: Stainless steel (SUS303) Sensing surface Note: Use the stamped surface and its opposing surface as installation (reference) surfaces. 9 1.2 Optical axis Sensing surface Optical fiber: 1 dia. 10 4 2 dia. 2 Installation (reference) surface 2,000 2.5 Two, M2 3.5 10 17 1.2 dia. 2 Fiber Attachment (E39-F9) Sensing head * *Material: Stainless steel (SUS303) 67 Dimensions Accessories Protective Spiral Tubes E39-F32A/F32A5 E39-E32B/F32B5 M3 x 0.5; depth: 4 Head connector *1 (4.6 dia.) End cap *1 3 dia. 6 dia. 12 12 Tube *2 L *1. Material: Brass/nickel plating *2. Material: Stainless steel (SUS304) Note: 1. The length L is 1,000 for the E39-F32A/-F32B and 500 for the E39-F32A5/-F32B5. 2. The E39-F32B(5) consists of two E39-F32A(5)s. E39-F32C/F32C5 M4 x 0.7; depth: 4 Head connector *1 (5.6 dia.) End cap *1 4 dia. 7 dia. 12 12 Tube *2 L *1. Material: Brass/nickel plating *2. Material: Stainless steel (SUS304) Note: The length L is 1,000 for the E39-F32C and 500 for the E39-F32C5. E39-F32D/F32D5 M6 x 0.75; depth: 4 Head connector *1 (7 dia.) End cap *1 5 dia. 8.5 dia. 12 12 Tube *2 L *1. Material: Brass/nickel plating *2. Material: Stainless steel (SUS304) Note: The length L is 1,000 for the E39-F32D and 500 for the E39-F32D5. Other Accessories Fiber Cutter E39-F4 Thin-fiber Attachments E39-F9 8 45 Mark indicating position of insertion into Amplifier Unit 1.1 dia. (2.2 dia.) 24.5 10 3.6 dia. 11.7 25 Note: Two per set. *Provided with thin-fiber models. Standard-fiber insertion hole Thin-fiber insertion hole Fiber Connector E39-F10 Retention Fiber: 2.2 dia. clip *2 Retention clip *2 Splice *1 3.8 dia. Fiber: 2.2 dia. 3 dia. 26 12.8 *1. Material: Polyester *2. Material: Brass Fiber Connector E39-F13 E39-F14 E39-F15 (48.6) 9.2 32.6 29.6 7.6 3.2 2 Note: Dimension A varies with the modelNote: number as shown inA varies with the model Dimension the following table. number as shown in the following table. 8 33.8 22.4 20.4 Four, 6 dia. Model E39-F13 E39-F14 Four, A (See note.) Four, 0.8 68 27.4 E39-F15 Four, R0.8 Model Dimension A Dimension A E39-F13 2.4 2.4 E39-F14 1.2 E39-F15 2.4/1.2 1.2 2.4/1.2 Accessories Other Accessories Sleeve Bender E39-F11 10.8 R12.5 R7.5 42.5 10 10 R5 R10 27 Lens Units Lens Units E39-F1 Side-view units E39-F2 M2.6 Effective depth: 3.2 2.8 dia. Spot-facing depth: 0.9 M2.6 x 0.45 Effective depth: 3.8 Spot-facing depth: 0.9 4 dia. 4 dia. 5.7 8.9 9.2 Material: Brass for the body and optical glass for the lens itself. Material: Brass for the body and optical glass for the lens itself. Note: Two per set. Note: Two per set. Reflection Unit with Lens E39-F3 M3 internally Two, 4 dia. toothed washer Two, 3.2 dia. 12 6.4 18 6.4 3 80.2 3.6 Two, M3 x 3 slotted-head set screws* 6.5 M3 x 6 angle-setting screw 20.7 8.5 Material: Brass for the body and aluminum for the base. * Secure the fiber head with the slotted-head set screws. Do not insert a lens (E39-F1). Lens Unit for Reflective Fiber Units E39-F3A Lens Unit for Reflective Fiber Units E39-F3A-5 M2 x 2 Allen-head set screw (for securing the fiber) Straight knurling 3 Lens surface (lens diameter: 3.7 mm) 2.1 dia. 13 23 2.1 dia. 5 dia. 4 dia. 6 dia. 4 dia. M3 x 0.5 Effective screw length: 3 6.5 16.5 Lens surface (lens diameter: 3.7 mm) Material: Aluminum for body and optical glass. for the lens. Material: Aluminum for body and optical glass. for the lens. Note: This is the Lens Unit for the E32-D32 and E32-C42. Note: This is the Lens Unit for the E32-C31 and E32-C41. Lens Unit for Reflective Fiber Units E39-F3B Lens Unit for Reflective Fiber Units E39-F3C Straight knurling Lens surface (lens diameter: 4.8 mm) 5 dia. 4.3 dia. 6 dia. 5.5 dia. 24.1 25.2 5.8 M3 x 0.5 Depth: 4.4 Material: Aluminum for body and optical glass. for the lens. Note: This is the Lens Unit for the E32-C31 and E32-C41. M3 x 0.5 Effective screw length: 3 10.9 Lens surface (lens diameter: 3.7 mm) Material: Aluminum for body and optical glass. for the lens. Note: This is the Lens Unit for the E32-C31 and E32-C41. 69 Precautions Precautions for Correct Use Fiber Cutting Procedure Cut a thin fiber as follows: Fiber Units Mounting Tightening Force The tightening force applied to the Fiber Unit should be as follows: Screw-mounting Model Spring mounting clip Toothed washers Cylindrical Model Retaining screw (flat head or sunken head) (M3 max.) Thin fiber attachment (E39-F9 An attachment is temporarily fitted to a thin fiber before shipment. Temporarily fitted Secure the attachment after adjusting the position of it in the direction indicated by the arrow. Nuts (attachment) Fiber Units M6 screw/6-mm dia. cylinder 0.98 N*m max. M3/M4 screw 0.78 N*m max. 2-mm dia./3-mm dia. cylinder 0.29 N*m max. 1.5-mm dia./1-mm dia. cylinder 0.2 N*m max. 0.78 N*m max. E32-L25A E32-M21 Up to 5 mm to the tip: 0.49 N*m max. More than 5 mm from the tip: 0.78 N*m max. E32-T16 0.49 N*m max. E32-R21 0.39 N*m max. E32-T16W(R) E32-T16P(R) E32-T16J(R) E32-L24S E32-L24L E32-T25L Insert the fiber to be cut into the E39-F4. Two holes for thin fiber Three holes for standard fiber (2.2-mm dia.) E32-T12F 5-mm dia. fluororesin model E32-D12F 6-mm dia. fluororesin model Cutter (E39-F4) Claming torque Approx. 0.5 mm Finished state (proper cutting state) Insertion direction Note: Insert the fiber in the direction indicated by arrow. Connection * Do not pull or press the Fiber Units. The Fiber Units have a withstand force of 9.8 N or 29.4 N maximum. * Do not bend the Fiber Unit beyond the permissible bending radius given under Ordering Information. * Do not bend the edge of the Fiber Units (excluding the E32-T R and E32-D R). Correct Incorrect 20 mm min. 0.29 N*m max. Amplifier Unit Use a proper-sized wrench. Fiber Unit 20 mm min. * Do not apply excess force on the Fiber Units. Correct Incorrect Fiber Unit Nylon wireholder The Fiber Head could be broken by excessive vibration. To prevent this, the following is effective: A one-turn loop can absorb vibrations. Tape 70 E39-F11 Sleeve Bender * The bending radius of the stainless steel tube should be as large as possible. The smaller the bending radius becomes, the shorter the sensing distance will be. * Insert the tip of the 1.2 mm dia. max stainless steel tube to the 1.3 mm dia. min. R10 mm Sleeve Bender and bend R12.5 mm the stainless steel tube R5 mm slowly along the curve of R7.5 mm the Sleeve Bender (refer Fiber tip position to the figure). mark 90 max. 10 mm Stainless steel tube Liquid-level Detection Sensors: Tube-mounting Models * Ensure that the tube is not deformed when using a band to secure the Fiber Unit. * Drops of water, bubbles, or haze inside the tube may cause malfunctions. * Adjustment E32-G14 The sensing distance is short, making the incident light intensity large. This makes it impossible to teach without a workpiece. Perform teaching with and without a workpiece. 10 mm Do not bend here. Heat-resistant Fiber Units (E32-D51 and E32-T51) * The fibers of these Units cannot be extended using the E39- F10 Fiber Connector. * The maximum allowable temperature for continuous operation with these Units is 130C. It is 150C for shortterm use. E32-T14 and E32-G14 These Units may enter the light-ON state if there are reflecting objects at the ends of the lenses. In this case, attach the black stickers provided to the ends of the lenses. Liquid-level Detection Sensors (E32-D82F) * Secure the Fiber Unit using the unbendable section. Otherwise, the liquid-level detection position may be displaced. * For applications in hazardous environments, install the Fiber Unit in the hazardous environment but install the Amplifier Unit in a safe environment. Stickers Wafer Sensors (E32-L25(A)) * To ensure correct performance, insert the fiber with a white line into the emitter-side port of the Amplifier Unit. E32-T16 and E32-T16P To use the slit provided, peel off the Example backing sheet, align it with the edges E32-T16's sensing head of the sensing surface, and attach it to the sensing head. Use the slit in Slit provided applications where saturation occurs (i.e., changes in light intensity cannot be obtained) due to short sensing distances. E32-M21 Separate the 4 fibers by distances sufficient to prevent interference. Vacuum-resistant Fiber Units (E32-V) Although Flanges, Fiber Units on the vacuum side, and Lens Units have been cleaned, as an extra precaution, clean these products with alcohol before use in high-vacuum environments to ensure that they are properly degreased. Liquid-level (E32-D82F) Detection Position The liquid-level detection position is at a distance of 5.22 mm from the end of the Liquid-level fluororesin section. detection position (Refer to the diagram on the 5.2 mm (from the end of the fluororesin section) right.) The liquid-level detection po-sition varies with the surface tension of the liquid and the degree of wetness at the Fiber Unit's detection position. 2 * Other Considerations Liquid Level (E32-D82F) * Operation may become unstable in the following cases: Bubbles stick to the cone of the sensing head. Solute is deposited on the cone of the sensing head. The liquid has a high viscosity. * There are some liquids, such as milky white liquids, for which detection is not possible. * Do not let the end of the fluororesin section bump into another object. Damage to, or deformation of, the sensing head may result in unstable operation. Heat-resistant Fiber Units (E32-D81R, E32-D61, and E32-D73) The pitch of the emission-side and reception-side fiberinsertion ports varies with the Amplifier Unit. Be sure to use an appropriate Fiber Unit. Amplifier Unit Fiber Unit E3X-DA -S E3X-MDA E32-D -S E3X-DA -N E3X-NA E32-D 71 Precautions Accessories Use of E39-R3 Reflector 1. Use detergent, etc., to remove any dust or oil from the surfaces where tape is applied. Adhesive tape will not be attached properly if oil or dust remains on the surface. 2. The E39-R3 cannot be used in places where it is exposed to oil or chemicals. 2. P ush the fiber into the Protective Spiral Tube. The tube should be straight so that the fiber is not twisted when inserted. Then turn the end cap of the spiral tube. Protective Spiral Tube Fiber Unit Protective Spiral Tube Fiber Unit Mounting panel Hexagon clamping nut Fiber Unit Toothed washer Protective Spiral Tube 4. U se the attached saddle to secure the end cap of the Protective Spiral Tube. To secure the Protective Spiral Tube at a position other than the end cap, apply tape to the tube so that the portion becomes thicker in diameter. 72 Saddle Tube End cap Splice Fiber Unit Retention unit E39-F32 Protective Spiral Tubes 1. Insert a fiber to the Protective Spiral Tube from the head connector side (screwed) of the tube. 3. S ecure the Protective Spiral Tube on a suitable place with the attached nut. E39-F10 Fiber Connector Mount the Fiber Connector as shown in the following illustrations. Fiber Unit Retention unit Fiber Unit Fiber Unit * T he Fiber Units should be as close as possible when they are connected. Sensing distance will be reduced by approximately 25% when fibers are connected. * Only 2.2-mm dia. fibers can be connected. Fiber Optic and Laser Optic Amplifiers Simple Fiber Optic Amplifiers E3X-SD with Digital Display, E3X-NA with Bar Graph Display E3X-SD Features Streamlined features provide basic sensing immediately after plug-in Easy push button teach with or without workpiece Large, 6 mm wide digital display provides read-out of incident and operating level Incident settings and management can be performed reliably with 0 to 999% (10 times) fin tune adjustment Built-in OFF-delay, ON-delay, one-shot timer Optical communication design prevents mutual interference for up to 5 amplifiers Pre-wired (2 m cable) and wire-saving connector models available E3X-NA Features Streamlined features provide basic sensing immediately after plug-in Use the LED bar display to quickly confirm sensor performance Optical communication design prevents mutual interference for up to 5 amplifiers Green LED models address mark-detecting applications High-speed models have a response time of 50 micro-seconds (s) IP66 Water-resistant models available with M8 connector or pre-wired with 2 m cable Ordering Information Amplifier Units Digital Display and Direct Key Setting Item Appearance Connection method Ratings and Specifications Pre-wired Standard models Model NPN output PNP output E3X-SD11 E3X-SD41 E3X-SD6 E3X-SD8 -- Wire-saving connector 73 Fiber Optic and Laser Optic Amplifiers Bar Display and Adjuster Setting Item Appearance Connection method Ratings and Specifications Pre-wired Model NPN output PNP output E3X-NA11 E3X-NA41 E3X-NA6 E3X-NA8 E3X-NA11F E3X-NA41F E3X-NA11V E3X-NA41V E3X-NA14V E3X-NA44V -- Standard models Wire-saving connector High-speed detection models Pre-wired Response time: 20 s Pre-wired Degree of protection: IP66 Water-resistant Connector (MB) Specifications Type Digital display and direct key setting Standard models Item Model Standard models E3X-NA EX-SD Light source (wavelength) Red LED (620 nm) High-speed detection models Water-resistant models E3X-NA F E3X-NA V Red LED (680 nm) Power supply voltage 12 to 24 VDC 10%, ripple (p-p): 10% max. Current comsumption 960 mW max. (Power supply: 24 V, Current consumption: 40mA max. Control output Open-collector output (NPN or PNP) Load power supply: 26.4 V max., Load current: 50 mA max. (Residual voltage: 1.5 V max.) (*1) Light-ON/Dark-ON mode selector Protection circuits Power supply reverse polarity protection, output short-circuit protection, output reverse polarity protection (*2) Timer function ON/OFF-delay timer: 10 ms (each fixed) Mutual interference prevention Up to 5 Amplifiers (optically synchronized) Weight (packed state) Pre-wired model: Approx. 100 g, Model with connector: Approx. 55 g (*3) Note: *1. For the E3X-NA, residual voltage is 1V max. *2. The E3X-NA does not have output reverse polarity prevention. *3. Add 10 g for water-resistant models. 74 Bar display and adjuster setting 35 mA max. OFF-delay timer: 40 ms (fixed) None Up to 5 Amplifiers (optically synchronized) E3X-DA-S Dual Display Digital Fiber Optic Amplifier Features Dual digital display can monitor current and preset values, including digital, bar, percent and hold display functions Power tuning function addresses saturation or insufficient light conditions 4-element LED and Auto Power Control ensure stable, long term performance Three inspection speeds/distances in one model: standard, high-speed and high-resolution Advanced functions include differential operation for minute object detection, 2 independent outputs for area detection, remote input function and counter function Advanced models available for Mark Detection; Two-Outputs for Area output, self-diagnostics or differential operation; external input for remote setting Optical communications ports built into each sensor enables data exchange with one another and the Omron Mobile Console remote control Pre-wired (2 m cable) and wire-saving connector models available Ordering Information Amplifier Units with Cables Item Appearance Advanced models Model NPN output PNP output -- E3X-DA11-S E3X-DA41-S Green LED -- E3X-DAG11-S E3X-DAG41-S Blue LED -- E3X-DAB11-S E3X-DAB41-S Two-output models Area output, self-diagnosis, differential operation E3X-DA11TW-S E3X-DA41TW-S External-input models Remote setting, counter, differential operation E3X-DA11RM-S E3X-DA41RM-S Standard models Mark-detecting models Functions Amplifier Units with Connectors Item Advanced models Functions Model NPN output PNP output -- E3X-DA6-S E3X-DA8-S Green LED -- E3X-DAG6-S E3X-DAG8-S Blue LED -- E3X-DAB6-S E3X-DAB8-S Two-output models Area output, self-diagnosis, differential operation E3X-DA6TW-S E3X-DA8TW-S External-input models Remote setting, counter, differential operation E3X-DA6RM-S E3X-DA8RM-S Standard models Mark-detecting models Appearance 75 Fiber Optic and Laser Optic Amplifiers Specifications Type Model Item Standard models Mark-detecting models Advanced, twooutput models Advanced, externalinput models NPN output E3X-DA11-S E3X-DAG11-S E3X-DAB11-S E3X-DA11TW-S E3X-DA11RM-S PNP output E3X-DA41-S E3X-DAG41-S E3X-DAB41-S E3X-DA41TW-S E3X-DA41RM-S Light source (wavelength) Red LED (650 nm) Supply voltage 12 to 24 DVC 10%, ripple (p-p) 10% max. Power comsumption 960 mW max. (current consumption: 40 mA max. at power supply voltage of 24 VDC) Control output Load power supply voltage: 26.4 VDC; NPN/PNP open collector; load current: 50 mA max.: residual voltage: 1 V max. Circuit protection Reverse polarity for power supply connection, output short-circuit Highspeed Response mode time NPN PNP Standard mode Green LED (525 nm) Blue LED (470 nm) 48 s for operation and 50 s for reset Red LED (650 nm) 1,080 mW max. (current consumption: 45 mA max. at power supply voltage of 24 VDC) 80 s for operation and reset respectively 53 s for operation and 55 s for reset 48 s for operation and 50 s for reset (*1) 53 s for operation and 55 s for reset (*1) 1 ms for operation and reset respectively High-resolution mode 4 ms for operation and reset respectively Power tuning Functions Light emmission power and reception gain, digital control method Differential detection -- Timer function Select from OFF-delay, or one-shot timer. 1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments, 200 ms to 1 s set in 100-ms increments, and 1 to 5 s set in 1 s-increments) Automatic power control (APC) High-speed control method for emission current Zero-reset Display can be reset to zero when required (negative values can be displayed). Initial reset Settings can be returned to defaults as required. Mutual interference prevention Possible for up to 10 Units. (*2, *3) Counter I/O settings Weight (packed state) Switchable between up counter and down counter. Set count: 0 to 9,999,999 -- -- Approx. 100 g Note: *1. When counter is enabled: 80 s for operation and resety respectively. *2. Communications are disabled if the detection mode is selected during high-speed mode; the communications functions for mutual interference prevention and the Mobile Console will not function. *3. Mutual interference prevention can be used for up to 6 Units if power tuning is enabled. 76 Switchable between single edge and double edge detection mode Single edge: Can be set to 250 s, 500 s, 1 ms, 10 ms, or 100 ms. Double edge: Can be set to 500 s, 1 ms, 2 ms, or 200 ms. Output setting (Select from channel 2 out-put, area output, or selfdiagnosis.) External input setting (Select from teaching, power tuning, zero reset, light OFF, or counter reset.) E3X-MDA Two-channel Dual Display Digital Amplifier Features Two independent fiber-optic amplifiers in a slim, 10 mm wide track-mount unit Designed for gang mounting up to 18 sensors (9 units) Dual digital display can monitor current and preset values, including digital, bar, percent and hold display functions Three inspection speeds/distances in one model: standard, high-speed and high-resolution Logical AND/OR control output for local control in high-speed applications 4-element LED and Auto Power Control ensure stable, long term performance O ptical communications ports built into each sensor enables data exchange with one another and the Omron Mobile Console remote control P re-wired (2 m cable) and wire-saving connector models available Ordering Information Dual Amplifiers Sensing heads Order E32 fiber-optic cables separately Setup Features Light source And/OR logic output 3 sensing speeds Connection method Model NPN output PNP output Pre-wired E3X-MDA11 E3X-MDA41 Connector E3X-MDA6 E3X-MDA8 Red (650 nm) One master connector for ganged units 77 Fiber Optic and Laser Optic Amplifiers Specifications Type Model Item 2-channel models NPN output E3X-MDA11 E3X-MDA6 PNP output E3X-MDA41 E3X-MDA8 Light source (wavelength) Red LED (650 nm) Supply voltage 12 to 24 DVC 10%, ripple (p-p) 10% max. Power comsumption 1,080 mW max. (current consumption: 45 mA max. at power supply voltage of 24 VDC) Control output Load power supply voltage: 26.4 VDC; NPN/PNP open collector; load current: 50 mA max.: residual voltage: 1 V max. Circuit protection Reverse polarity for power supply connection, output short-circuit HighNPN speed PNP Response mode time Standard mode 130 s (*1) for operation and reset respectively 1 ms for operation and reset respectively High-resolution mode 4 ms for operation and reset respectively Functions Power tuning Light emmission power and reception gain, digital control method Timer function Select from OFF-delay, or ON-delay, one-shot timer. 1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments, 200 ms to 1 s set in 100-ms increments, and 1 to 5 s set in 1 s-increments) Automatic power control (APC) High-speed control method for emission current Zero-reset Display can be reset to zero when required (negative values can be displayed). Initial reset Settings can be returned to defaults as required. Mutual interference prevention Possible for up to 9 Units (18 channels) (*2, *3) I/O settings Output setting (Select from channel 2 output, AND, OR, leading edge sync, falling edge sync, or differential output) Weight (packed state) Approx. 100 g Approx. 55 g Note: *1. When differential output is selected for the output setting, the second channel output is 200 s for the operation and reset respectively. *2. Communications are disabled if the detection mode is selected during high-speed mode; the communications functions for mutual interference prevention and the Mobile Console will not function. *3. Mutual interference prevention can be used for up to 5 Units (10 channels) if power tuning is enabled. 78 E3X-DAC-S True Color Fiber Optic Amplifiers with Digital Dual Display Features Reliability through precise and true color detection with White LED emitter and RGB (Red, Green and Blue) processing Enhanced stability: workpiece movement does not affect the sensor as the receiver element processes light as a ratio to compensate for intensity variations Easy push button setup guides the user to place the workpiece in an appropriate position for teaching Full-functional, dual digital display can monitor current preset values, including digital, bar, percent and hold display functions On-Board timing function incorporating OFF-delay, On-delay, and one-shot timing functions A dvanced models offer remote control as well as twin sensing and output to simultaneously distinguish between two registered colors P re-wired (2 m cable) and wire-saving connector models available Ordering Information Amplifier Units Amplifier Units with Cables Item Appearance Functions Model NPN output PNP output Standard models Timer, Response speed change E3X-DAC11-S E3X-DAC41-S Advanced models Standard models + Simultaneous determination (2 colors) AND/OR output, Remote setting E3X-DAC21-S E3X-DAC51-S Amplifier Units with Connectors (Amplifier Unit Connectors must be purchased separately.) Item Standard models Appearance Functions Timer, Response speed change Model NPN output E3X-DAC6-S PNP output E3X-DAC8-S 79 Fiber Optic and Laser Optic Amplifiers Specifications Item Type Standard models Advanced models Model E3X-DAC -S ( : 11/41/6/8) E3X-DAC -S ( : 21/51) Light source (wavelength) White LED (420 to 700 nm) Sensing method C Mode: RGB ratio determination (or I Mode: Light intensity determination for red, green, or blue) (*1) Number of registered colors 1 2 (simultaneous determination) Power supply voltage 12 to 24 DVC 10%, ripple (p-p) 10% max. Power comsumption 960 mW max. (current consumption: 40 mA max. at power supply voltage of 24 VDC) Control output NPN or PNP open collector Load power supply voltage: 26.4 VDC max. load current: 50 mA max. (residual voltage: 2 V max.) Remote control input -- Protection circuits Reverse polarity for power supply connection, output short-circuit, Reversed output polarity protection Super-high-speed mode (*2) No-voltage input (contact/transistor) Operate or reset: 60 s Operate or reset: 120 s Operate or reset: 300 s Operate or reset: 600 s Operate or reset: 1 ms Operate or reset: 2 ms High-resolution mode Operate or reset: 4 ms Operate or reset: 8 ms Operating mode ON for match (ON for same color as registered color) or ON for mismatched (ON for different color from registered color) Timer function Timer type: OFF delay, ON delay, or one-short Timer range: 1 ms to 5 s (variable) Control outputs -- Output for each channel, AND output, and OR output Remote control -- One-point teaching, teaching with/without workpiece, zero reset, and light emission OFF Display switch (*3) Seven patterns total: Match + Threshold + Margin + Threshold, Analog bar display, Peak + Bottom, etc. Initialization Initial reset (factory defaults) or user reset (saved settings) Response High-speed mode time Standard mode Functions Weight (packed state) Pre-wired model: Approx. 100g, Amplifier unit connector model: Approx. 55 g Note: *1. When teaching with/without a workpiece, the best sensing method will be automatically selected (RGB ratio (C Mode) or light intensity determination (I Model)). If color differences are not strong enough and RGB ratios would result in unstable detection, then light intensity determination (I Mode) will be selected. *2. Mutual interference prevention cannot be used in super-high-speed mode, and light intensity determination (I Mode) must be used. *3. With light intensity determination (I Mode), the correlation is not displayed, but rather the light intensity is displayed. 80 E3C-LD/-LR Laser Optics Sensing Heads for Measurement Area, spot and line beam sensing heads offer variable focal point and optical axis alignment Safe Class I lasers require no special protective hardware Use with E3C-LDA, slim track-mount digital amplifiers (see page 82) Applications Adhesive and Seal Application Inspection Grease Application Inspection Area detection for minute objects Minute objects Edge white/black deviations Confirming sheet displacement before printing Improved product quality Noodle Protrusion Inspection Confirming marks on sheets Confirming grease application amounts for moving parts Confirming seal extraction Reduced defects Improved product quality Sheet Displacement Inspection Repeated Robot Arm Positioning Teaching for Calibration Reduced defects Improved operating rate Inspection for Fine Pins Line beam Inspect before packaging Positioning Area detection Confirming guide pin movement Misalignment Minute objects Reduced defects Improved product quality Reduced defects Improved operating rate Sensing Head Options Sensing method Diffuse reflective Coaxial retroflective with mirror surface rejection Beam shape Sensing distance Dimensions H x W x D mm Model Spot, 0.8 mm max. 30 mm to 1 mm 25 x 12.8 x 33 E3C-LD11 Line, 33 mm L 30 mm to 1 mm 27 x 13.2 x 36 E3C-LD21 Area, 33 x 15 mm 30 mm to 1 mm 27 x 13.2 x 36 E3C-LD31 Variable spot (0.8 mm dia.) Up to 7 m with E39-R12 25 x 12.8 x 39 E3C-LR11 Line, 28 mm L Up to 1.7 m with E39-R12 25 x 12.8 x 39 E3C-LR11 + E39-P31 Area, 28 x 16 mm Up to 900 mm with E39-R12 25 x 12.8 x 39 E3C-LR11 + E39-P41 Fixed spot (2 mm dia.) Up to 7 m with E39-R12 25 x 12.8 x 39 E3C-LR12 81 Fiber Optic and Laser Optic Amplifiers E3C-LDA Dual Display Digital Amplifier for Laser Optics Features Dual digital display simplifies setup and monitoring Selectable detection modes with response speed as fast as 100 s One-touch sensitivity setting with Power Tuning function compensates for saturation Provides analog voltage and discrete outputs for position control, height measurement and other gauging applications Dual output models available offering area output, differential operation and self-diagnostics External input models offer remote setting, built-in counter and differential operation Ordering Information Pre-Wired Amplifiers Type Functions Output type Output ratings Model NPN output PNP output Analog + Discrete outputs Area output, differential operation Analog, discrete 1 to 5 VDC, 50 mA at 26.4 VDC E3C-LDA11AN E3C-LDA41AN Dual discrete outputs Area output, differential operation, self-diagnostics Two open collector 50 mA at 26.4 VDC E3C-LDA11 E3C-LDA41 External input + Discrete output Built-in counter, differential operations, remote setting One open collector 50 mA at 26.4 VDC E3C-LDA21 E3C-LDA51 Amplifiers with Wire-Saving Connectors Type 82 Model Functions Output type Output ratings Dual discrete outputs Area output, differential operation, self-diagnostics Two open collector 50 mA at 26.4 VDC E3C-LDA6 E3C-LDA8 External input + Discrete output Built-in counter, differential operations, remote setting One open collector 50 mA at 26.4 VDC E3C-LDA7 E3C-LDA9 NPN output PNP output Specifications Type Model Diffuse-reflective E3C-LD11 E3C-LD21 Coaxial Retro-reflective E3C-LD31 Red semiconductor laser diode (650 nm), Light source 3 mW max. (JIS standard: Class 2, FDA (emission wavelength) standard: Class II) E3C-LR11 E3C-LR11 + E39-P31 E3C-LR11 + E39-P41 E3C-LR12 Red semiconductor laser diode (650nm), 2.5 mW max. (JIS standard: Class 2, FDA standard: Class II) 1 mW max. (JIS standard: Class 1) Sensing distance High-resolution mode: 30 to 1,000 mm Standard mode: 30 to 700 mm Super-high-speed mode: 30 to 250 mm (*1) 7m 5m 2 m (*2) 1,700 mm 1,300 mm 700 mm (*2) 900 mm 700 mm 400 mm (*2) 7m 5m 2 m (*2) Focus (*3) 0.8 mm max. (at distances up to 300 mm) 0.8 mm max. (at distances up to 1,000 mm) 28 mm (at 150 mm) 28 x 16 mm (at 150 mm) 2.0 mm dia. (at distances up to 1,000 mm) Functions Variable focal point mechanism (focus adjustment) (*4), optical axis adjustment mechanism (axis adjustment) Indicators LDON indicator: Green; Operation indicator: Orange Ambient illumination (receiver side) Incandescent lamp: 3,000 lx Ambient temperature Operating: -10 to 55C, Storage: -25 to 70C (with no icing or condensation) Ambient humidity Operating/storage: 35% to 85% (with no condensation) Insulation resistance 20 M min. at 500 VDC Dielectric strength 1,000 VAC at 50/60 Hz for 1 minute Shock resistance Destruction: 300 m/s2 6 directions 3 times each (up/down, right/left, forward/backward) Vibration resistance Destruction: 10 to 150 Hz with double amplitude of 0.7 mm, in X, Y, and Z directions for 80 min each Degree of protection IP40 (IEC 60529) Connection method Connector (standard cable length: 2 m) Materials Case and cover: ABS Front surface filter: Methacrylic resin Case and cover: ABS Front surface filter: Glass Weight (packed) Approx. 85 g Approx. 100 g 33 mm (at 150 mm) 33 x 15 mm (at 150 mm) IP40 (IEC 60529) Note: *1. Sensing distance values are for white paper. *2. These sensing distance values apply when a E39-R12 Reflector is used. The MSR function is built-in. The reflected light from the object being measured may affect the sensing accuracy, so adjust the threshold value before use. *3. The beam radius is the value for the middle measurement distance and indicates a typical value for the middle sensing distance. The radius is defined by light intensity of 1/e2 (13.5%) of the central light intensity. Light will extend beyond the main beam and may be affected by conditions surrounding the object being measured. *4. The E3C-LR12 has a fixed beam size (the focal point cannot be changed). 83 Fiber Optic and Laser Optic Amplifiers Specifications Analog Output Amplifiers Model E3C-LDA11AN E3C-LDA41AN Supply voltage 12 to 24 VDC 10%, ripple (p-p) 10% max. Power consumption 1080 mW max. Current consumption 45 mA max. at supply voltage of 24 VDC Analog output Discrete output Response time Repeatability Voltage output 1 to 5 VDC with connected load of 10k min. Type NPN open collector Rating 50 mA at 26.4 VDC Residual voltage 1 V max. Super high-speed mode 100 s High-speed mode 250 s Standard mode 1 ms High resolution mode 4 ms Super high-speed mode 4% FS High-speed mode 4% FS Standard mode 2% FS High resolution mode 2% FS Temperature influence 0.3% FS/C Connection method Pre-wired with 2 m cable Dimensions 32 H x 10 W x 78.5 D mm PNP open collector Discrete Output Amplifiers Type Advanced, twin-output models Advanced, external-output models Model NPN output E3X-LDA11 E3X-LDA6 E3X-LDA21 E3X-LDA7 Item PNP output E3X-LDA41 E3X-LDA8 E3X-LDA51 E3X-LDA9 Supply voltage 12 to 24 DVC 10%, ripple (p-p) 10% max. Power comsumption 1,080 mW max. (current consumption: 45 mA max. at power supply voltage of 24 VDC) Super-highspeed mode 100 s for operation and reset 80 s for operation and reset Response time Standard mode 1 ms for operation and reset respectively High-resolution 4 ms for operation and reset respectively mode Power turning, differential detection, timer, zero-reset, initial reset, mutual interference prevention (*1), preset counter (*2), reversed display Functions I/O settings Weight (packed state) Output setting (Select from channel 2 output, area output, or self-diagnosis.) External input setting (Select from teaching, power tuning, zero reset, light OFF, or counter reset.) Approx. 100 g Approx. 100 g Approx. 55 g Note: *1. Communications are disabled if super-high-speed mode is selected, and the mutual interference prevention function and the communications function for the Mobile Console will not function. *2. The preset counter is available only with advanced, external-input models. 84 Approx. 55 g Accessories Beam Unit Applicable Sensor Head Appearance Reflectors Beam Shape Model Line E39-P11 Area E39-P21 Line E39-P31 Area E39-P41 E3C-LD11 E3C-LR11 Type Appearance Model Standard Effective area: 23 x 23 mm E39-R12 Standard Effective area: 7 x 7 mm E39-R13 Transparent object detection Effective area: 23 x 23 mm E39-R14 Sheet (cuttable) Effective area: 195 x 22 mm E39-RS4 Sheet (cuttable) Effective area: 108 x 46 mm E39-RS5 Dimensions (Unit: mm) Sensor Head E3C-LD11 E3C-LR11 E3C-LR12 Reflector E39-R12/-14 E39-R13 E3C-LD21 E3C-LD31 85 Fiber Optic and Laser Optic Amplifier Accessories Wire-Saving Connector Models Streamlines installation and maintenance to reduce service time Unique connector design reduces wiring and space requirement because one master connector supplies power to all other slave connectors Detach the sensor without disturbing the fiber installation or output wiring for servicing The E3X-DA-S requires three wiring connections for the master sensor only. Each additional sensor in a group requires only one wiring connection. Shown: ONLY 7 WIRES with no additional extension connectors. Connectors Description Pre-wired models require three wiring connections for each sensor. Shown: 15 wires plus extension connector wires. Appearance Master connector (for first unit) Slave connector (for second and additional units) Cable length Conductors E3X-DA6-S, E3X-DA8-S, E3X-DAG6-S, E3X-DAG8-S, E3X-DAB6-S, E3X-DAB8-S, E3X-DAC6-S, E3X-DAC8-S, E3X-NA6, E3X-NA8, E3X-SD6, E3X-SD8 2m 3 E3X-CN11 E3X-DA6TW-S, E3X-DA8TW-S, E3X-DA6RM-S, E3X-DA8RM-S, E3X-MDA6, E3X-MDA8, E3C-LDA6, E3C-LDA7, E3C-LDA8, E3C-LDA9 2m 4 E3X-CN21 E3X-DA6-S, E3X-DA8-S, E3X-DAG6-S, E3X-DAG8-S, E3X-DAB6-S, E3X-DAB8-S, E3X-DAC6-S, E3X-DAC8-S, E3X-NA6, E3X-NA8, E3X-SD6, E3X-SD8 2m 1 E3X-CN12 E3X-DA6TW-S, E3X-DA8TW-S, E3X-DA6RM-S, E3X-DA8RM-S, E3X-MDA6, E3X-MDA8, E3C-LDA6, E3C-LDA7, E3C-LDA8, E3C-LDA9 2m 2 E3X-CN22 Compatible amplifiers Model M8 Connectors Use these connectors with water-resistant E3X-NA14V and E3X-NA44V amplifiers only. Size Cable specifications Appearance Cable type 2m Model XS3F-M421-402-A Straight connector 5m M8 Standard cable L-shaped connector 86 2m 5m Fourconductor cable XS3F-M421-405-A XS3F-M422-402-A XS3F-M422-405-A Mounting Bracket and Track Description Appearance Surface mounting bracket Mounting track End plate Dimensions H x W x D mm Specification Model 7.3 H x 35 W x 12 D 304 stainless steel; fits the DIN track holder E39-L143 500 L x 35 H x 7.3 D 0.5 m length PFP-50N 1000 L x 35 H x 7.3 D 1 m length PFP-100N 1000 L x 35 H x 16.0 D 1 m length PFP-100N2 50 x 10 x 10 Holds track-mounted devices in place PFP-M Mobile Console Program and monitor the following amplifiers remotely with mobile console: E3X-DA-S, E3X-MDA, E3C-LDA Console includes 1.5 m cable for remote setup connection to the programming head Programming head track mounts flush against leftmost amplifier AC adapter powers console Description Appearance/ Dimensions Model Mobile console kit Includes console, programming head, cable and AC adapter E3X-MC11-SV2 Mobile console (only) E3X-MC11-C1-SV2 136 H x 52.8 W x 22 D mm Programming head (only) Mounts on DIN rail E3X-MC11-H1 51.3 H x 20 W x 30.3 D mm E3X-Z12-1 Cable 1.5 m length 87 Fiber Optic and Laser Optic Amplifier Accessories Fiber Optic or Laser Optic Sensor Communication Unit Supports Multi-vendor Networks DeviceNet model PLC ON/OFF signals and incident light levels can be sent to the host PLC without any need for programming (using the Remote I/O Communications Slave function). Threshold values and function settings can be read, written, or taught (using the Message Communications function). Device parameters prepared on a personal computer connected to the network can be downloaded in a batch operation (using the Configurator). Fiber Amplifier Sensor Communication Unit E3X-DRT21-S Configurator Download a group of parameters for devices (Sensors, Temperature Controllers, etc., supporting DeviceNet) that you have prepared on your personal computer in a single batch. Optica l Com PLC Monitor operating hours. The operating hours for sensors can be stored in internal memory and used for planning maintenance and other applications. Up to 16 channels can be connected. 88 munic ations Mobile Console A built-in interface for a Mobile Console lets you bring setting and confirmation operations to your fingertips. Supports a wide range of sensors. The Unit supports a variety of digital sensors, including Fiber Sensors, Laser Sensors, and Proximity Sensors. Ordering Information Fiber Amplifier Sensor Communication Unit Wire-reducing Connector Type Model Type Model DeviceNet EX-DRT21-S Cordless Slave Connector E3X-CN02 Ratings and Specifications Item Description Communications Methods DeviceNet communications Communications functions Remote I/O Communications Slave function Monitors ON/OFF output, status, incident light level (digital display data) Message Communications functions Sets parameters using Explicit messages Configurator Edits slave devices parameters, enables device monitor functions Mobile Console connection E3X-MC11-S-V2 can be connected Power supply Supplied from the DeviceNet communications connector(power is also supplied to all connected Sensors through Wire-reducing Connectors) Maximum connectable Sensors 13 or 16 (depending on the operation mode) Connectable Sensors E3X-DA-S Series or E3X-MDA Series Digital Fiber Sensor E3C-LDA Series Laser Photoelectric Sensor with Separate Digital Amplifier E2C-EDA High-resolution Digital Proximity Sensor with Separate Amplifier (use connector-type Amplifier Units and the E3X-CN02 Cordless Slave Connector) Power supply voltage 11 to 25 VDC Current comsumption (See note.) 70 mA max. Ambient operating temperature -20 to 55C Ambient operating humidity 35% to 85% (with no condensation) Storage temperature -30 to 70C Dimensions (mm) 30 x 34.6 x 71.3 (W x H x D) Weight (packed state) Approx. 150 g Note: This does not include the current supplied to the Sensor. 89 Dimensions (Unit: mm) Fiber Optic Amplifiers Amplifier Units with Cables With Mounting Bracket Attached E3X-SD11 E3X-SD41 E3X-NA11 E3X-NA11F E3X-NA41 E3X-NA41F A *1 Operation indicator 3 Two, 2.4 dia. 4-dia. vinyl-insulated round cable with 3 conductors* (Conductor cross section: 0.2 mm2; Insulator diameter: 1.1 mm), Standard length: 2 m. 64.3 10 38.6 5.3 Mounting Holes Two, M3 31.5 8 9.9 10.7 16 10.75 4.1 Hole for optical communications *2 2.4 16 22.4 13 4 34.8 Mounting bracket (E39-L143) (Order separately) Stainless steel (SUS304) Two, 3.2-dia. holes 22.4 16 4.4 3.4 *1. The mounting bracket can also be used on side A. *2. There is no hole for E3X-NA@F models. 4.4 3.4 Amplifier Units with Connectors E3X-SD6 E3X-SD8 E3X-NA6 E3X-NA8 Operation indicator 10 3 64.3 Two, 2.4 dia. 31.5 8 14 9.9 10.7 5.5 3.4 1.8 38.6 13 5.1 3.9 1.7 36.7 Hole for optical communications (for preventing mutual interference) 1.8 4.2 6.2 1.7 Dimensions with Master Connector Connected Dimensions with Slave Connector Connected 71 67.5 71 67.5 64.3 64.3 E3X-CN11: 4.0 dia. E3X-CN12: 2.6 dia. 31.5 1.5 1.8 5.1 3.9 90 31.5 17.45 12.95 11.55 1.5 12.95 4 10 1.8 5.1 3.9 3 4.8 4 10 Amplifier Units with Cables, Water-resistant Models With Mounting Bracket Attached E3X-NA11V E3X-NA41V 28.65 25.95 9.2 *2 Operation indicator Incident level indicators A *1 81.5 Two, 2.4 dia. 6.9 12 40 2.8 33 8 9.9 11.2 10.7 3.9 3.4 37 67.2 11.5 Mounting Holes Hole for optical communications 16 23.9 14.4 4.3 16 23.9 3.4 Two, M3 6.6 Mounting bracket (E39-L148) (Order separately) 5.4 Stainless steel (SUS304) 16 5.4 3.4 *1. The mounting bracket can also be used on side A. *2. 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.45 mm2, Insulator diameter: 1.1 mm), Standard length: 2 m. Amplifier Units with Connectors, Water-resistant Models E3X-NA14V E3X-NA44V With Mounting Bracket Attached 28.65 25.95 * The mounting bracket can also be used on this side A. 9.2 Operation indicator Incident level indicators A* 81.5 Two, 2.4 dia. 6.9 12 40 2.8 M8 33 8 9.9 11.2 10.7 3.9 3.4 37 67.2 11.5 Mounting Holes Two, M3 Hole for optical communications 16 23.9 14.4 4.3 16 23.9 3.4 5.4 11 Mounting bracket (E39-L148) (Order separately) Stainless steel (SUS304) 16 5.4 3.4 91 Dimensions (Unit: mm) Amplifier Units with Cables E3X-DA11-S E3X-DA11-S E3X-DA41-S E3X-DA41-S E3X-DAG11-S E3X-DAC11-S E3X-DAG41-S E3X-DAC21-S E3X-DAB11-S E3X-DAB41-S E3X-DAC41-S E3X-DA11RM-S E3X-DAC51-S E3X-DA41RM-S E3X-DAG11-S E3X-DA11TW-S E3X-DA41TW-S E3X-DAG41-S E3X-DAB11-S E3X-DA11-S E3X-DA41-S E3X-DAB41-S E3X-DAG11-S E3X-DA11RM-S E3X-DAG41-S E3X-DA41RM-S E3X-DAB11-S E3X-DAB41-S E3X-DA11TW-S E3X-DA11RM-S E3X-DA41TW-S E3X-DA41RM-S E3X-DA11TW-S E3X-MDA11 E3X-DA41TW-S E3X-MDA41 Round ( ): Power tuning indicator Oblong ( ): Operation indicator for channel 2 Operation indicator Main display Vinyl-insulated round cable Standard length: 2 m* Sub-display Sub-dislay Round ( ): Power tuning indicator Oblong ( ): Operation indicator for channel 2 Operation indicator Main display Vinyl-insulated round cable Standard length: 2 m* Sub-dislay *Cable Specifications E3X-DA11-S/DA41-S/DAG11-S/ Cable Specifications DAG41-S/DAB11-S/DAB41-S E3X-DA11TW-S/DA41TW-S/ E3X-DA11-S/DA41-S/DAG11-S/ DA11RM-S/DA41RM-S DAG41-S/DAB11-S/DAB41-S/ DAC11-S/DAC41-S A 4-dia., 3-conductor (conductor cross-sectional area: 0.2 mm2; insulation diameter: 1.1 mm) A 4-dia., 4-conductor (conductor cross-sectional 2; insulation diameter: 1.1 mm) 0.2 mm3-conductor Aarea: 4-dia., (conductor cross-sectional area: 0.2 mm2; insulation diameter: 1.1 mm) E3X-DA11TW-S/DA41TW-S/ A 4-dia., 4-conductor (conductor cross-sectional With Mounting Bracket Attached DA11RM-S/DA41RM-S area: 0.2 mm2; insulation diameter: 1.1 mm) 32.8 *Cable Specifications 29.8 E3X-MDA11/-MDA41 3.9x3 E3X-DA11-S/DA41-S/DAG11-S/ 15.1 =11.7 DAG41-S/DAB11-S/DAB41-S 12.15 3.25 E3X-DA11TW-S/DA41TW-S/ E3X-DAC21-S/-DAC51-S DA11RM-S/DA41RM-S 4.3 10 3.9x3=11.7 A 4-dia., 2-conductor (conductor cross-sectional 2 (conductor cross-sectional A 4-dia.,0.2 3-conductor area: mmThe ; insulation diameter; 1.1onmm) Mounting Bracket can also be used 2 area: 0.2 mm ; insulation diameter: 1.1 mm) this side. AA 4-dia., 5-conductor 4-dia., 4-conductor (conductor (conductor cross-sectional cross-sectional area: 0.2 mm2; insulation diameter: 1.1 mm) area: 0.2 mm2; insulation diameter; 1.1 mm) With Mounting Bracket Attached 70 3.9x3=11.7 32.8 Two, 2.4 dia. 29.8 3.9x3 =11.7 3.25 15.1 12.15 4.5 9.9 5.65 3.4 The Mounting Bracket can also be used on this side. 32 12.5 4.3 10 70 16 34.8 28.1 18.7 44.3 Two, 2.4 dia. Two, 3.2 dia. holes 3.4 Two, M3 4.4 9.9 4.5 5.65 16 28.1 16 28.1 16 34.8 18.7 44.3 3.4 Two, M3 92 28.1 Hole for optical communications Mounting Bracket (E39-L143) SUS304 stainless steel Two, 3.2 dia. holes 16 32 12.5 3.4 Mounting Holes Mounting Holes Hole for optical communications Mounting Bracket (E39-L143) SUS304 stainless steel 4.4 16 Amplifier Units with Connectors E3X-DA6-S E3X-DA6-S E3X-DA8-S E3X-DA8-S E3X-DAC6-S E3X-DAG6-S E3X-DAG8-S E3X-DAC8-S E3X-DAB6-S E3X-DAG6-S E3X-DAB8-S E3X-DAG8-S E3X-DA6RM-S E3X-DA8RM-S E3X-DAB6-S E3X-DA6TW-S E3X-DAB8-S E3X-DA8TW-S E3X-DA6RM-S E3X-DA8RM-S E3X-DA6TW-S E3X-DA8TW-S Round ( ): Power tuning indicator Oblong ( ): Operation indicator for channel 2 Operation indicator Main display Sub-dislay *1 The Mounting Bracket can also be used on this side. *2 Cable Diameters With Mounting Bracket Attached 3.9x3=11.7 32.8 A*1 29.8 3.9x3 15.1 =11.75 12.15 3.25 10 70 4.3 4.0-mm dia. E3X-CN11 (3 conductors) E3X-CN21 (4 conductors) E3X-CN22 (2 conductors) 2.6-mm dia. E3X-CN12 (1 conductor) 8.1 Connector Two, 2.4 dia. Dia. A*2 32 4.5 9.9 5.65 3.4 12.95 28.1 16 34.8 18.7 44.3 Two, 3.2 dia. holes 3.4 Two, M3 Hole for optical communications Mounting Bracket (E39-L143) SUS304 stainless steel 4.4 16 Mounting Holes 28.1 16 93 Dimensions (Unit: mm) E3C-LDA Laser Optic Amplifiers Pre-wired Models E3C-LDA11 E3C-LDA21 E3C-LDA41 E3C-LDA51 E3C-LDA11AN E3C-LDA41AN 94 Amplifier Units with Connectors E3C-LDA6 E3C-LDA7 E3C-LDA8 E3C-LDA9 95 Dimensions (Unit: mm) Master Connectors E3X-CN11 E3X-CN21 +50 0 2,000 10 6 2.9 10.7 6.8 2.6 4 4 dia. * 14.4 6 8.4 15.1 0.8 102 302 50 +5 0 *E3X-CN11:A2.6-dia. round cable with 3 conductors (Conductor cross section: 0.2 mm diameter: 1.1 mm) 1.1 mm) is used. *E3C-CN11: 4-dia., vinyl-insulated 3-conductor, vinyl-insulated round cable (conductor cross-sectional area: 0.2, Insulator mm2; insulation diameter: *E3C-CN21: A 4-dia., 4-conductor, vinyl-insulated round cable (conductor cross-sectional area: 0.2 mm2; insulation diameter: 1.1 mm) is used. 2 Slave Connectors E3X-CN12 E3X-CN22 +50 0 2,000 10 6 10.7 6.8 2.9 4 2.6 E3X-CN12: 2.6 dia. E3X-CN22: 4 dia. * 14.4 6 102 302 8.4 15.1 0.8 3 +5 0 50 *E3X-CN12:A2.6-dia. vinyl-insulated roundvinyl-insulated cable with 1 conductor (Conductor crosscross-sectional section: 0.2 mm area: , Insulator diameter: 1.1 mm) 2 *E3C-CN12: 2.6-dia.,single-conductor, round cable (conductor 0.2 mm ; insulation diameter: 1.1 mm) is used. 2 *E3C-CN22: A 4-dia., 2-conductor, vinyl-insulated round cable (conductor cross-sectional area: 0.2 mm ; insulation diameter: 1.1 mm) is used. 2 Mounting Brackets E39-L143 34.8 22 2.5 (10.3) 3 16 Mounting Holes Two, M3 7.3 5.3 26.8 Two, 3.2 dia. 3 Material: Stainless steel (SUS304) 16 7 160.1 3 Four, R1.7 3.4 10.3 10 max. 7 1 3.4 End Plates PFP-M 11.5 1 50 M4 x 8 panhead screw 10 M4 spring washer 4.8 6.2 1 1.3 1.8 35.5 35.3 96 1.8 10 Mobile Console E3X-MC11-SV2 E3X-MC11-S Mobile Console Head Mobile Console Communications jack AC adapter jack Menu indicators 22 Optical communications connection indicator 52.8 Communications jack Channel indicator 10 20 Sensor operation indicator Main display Channel buttons Sub-display (38.2) 31.8 13.2 13.1 16.3 28.8 1.2 5.1 12.3 136 UP key RIGHT key 17.3 24.3 30.3 LEFT key 9.9 ESC/PWR key DOWN key 27.7 Optical communications position M5 ball plunger 36.7 51.3 31.2 5.6 ENT key Operation keys Battery indicators 50 DeviceNet Communication Unit E3X-DRT21-S 34.6 34.8 71.3 (75) (106) 16 30 (65) 97 Part Number Index By Page Number Model Features/ Applications Detecting Distance Ratings/ Characteristics Dimensions E32-A01 14 38 50 65 E32-T15ZR E32-A02 14 38 50 65 E32-T16 E32-A03 16 39 50 66 E32-T16J E32-A03-1 16 39 50 66 E32-T16JR E32-A04 16 40 50 67 E32-T16P E32-A04-1 16 40 50 67 E32-T16PR E32-A07E1 15 39 50 66 E32-T16W E32-A07E2 15 39 50 66 E32-T16WR E32-A08 15 39 50 66 E32-A09 15 39, 43 50 E32-A09H 15 39 E32-A09H2 15 Features/ Applications Detecting Distance Ratings/ Characteristics Dimensions 6 18, 41 49 52 25, 42 49 55 24 49 55 24, 42 49 55 24 49 55 24, 42 49 55 24 49 54 10 24, 42 49 54 E32-T17L 8,17 21, 41 49 53 66 E32-T21 6 20, 41 49 52 50 66 E32-T21L 22 49 53 39 49 66 E32-T21R 18 49 51 E32-C11N 32 49 60 E32-T22 19, 41 49 51 E32-C31 34, 43 49 61 E32-T22B 20, 41 49 52 E32-C31N 32 49 60 E32-T22R 18 49 51 34, 43 49 61 E32-T221B 20, 41 49 52 34, 43 49 61 E32-T222 19, 41 49 51 18 49 51 E32-CC200 9, 17 E32-CC200R 10 10 6 6 6 E32-D11 7 31, 43 49 59 E32-T222R E32-D11L 8, 17 33, 43 49 60 E32-T223R 8 23 49 53 E32-D11N 7 32 49 60 E32-T22B 6 20 49 52 E32-D11R 7 29, 43 49 58 E32-T22L 22, 41 49 53 E32-D11U 7 33, 43 50 59 E32-T22R 6 18 49 51 E32-D12 7 30 49 58 E32-T22S 10 23, 42 49 54 E32-D12F 12 37, 44 49 64 E32-T24 6 20, 41 49 51 E32-D12R 7 29, 43 49 58 E32-T24R 6 18 49 51 E32-D14F 12 37, 44 50 64 E32-T24S 10 23, 39, 42 50 54 E32-D14L 7 30 49 58 E32-T25X 6 19, 41 49 51 E32-D14LR 7 29, 43 49 58 E32-T25XB 6 20, 41 49 52 E32-D15X 7 30 49 58 E32-T25XR 6 18 49 51 E32-D15XB 7 31, 43 49 60 E32-T25Y 6 20, 41 49 52 E32-D15XR 7 29, 43 49 58 E32-T25YR 6 18 49 52 E32-D15Y 7 31 49 59 E32-T25Z 6 20, 41 49 52 E32-D15YR 7 29, 43 49 59 E32-T25ZR 6 18 49 52 E32-D15Z 7 31 49 59 E32-T333-S5 23 49 54 E32-D15ZR 7 29, 43 49 59 E32-T334-S5 23 49 54 E32-D16 8 33 49 60 E32-T33-S5 23 49 53 E32-D21 7 32, 43 49 59 E32-T51 25, 42 50 55 E32-D211 31, 43 49 58 E32-T51F 27, 42 50 56 E32-D211R 29 49 58 E32-T51V 1M 27, 42 50 57 E32-D21B 32, 43 49 59 E32-T54 25, 42 50 55 E32-D21L 33, 43 49 60 E32-T54V 1M 13 28, 42 50 57 E32-D21R 7 29 49 58 E32-T61-S 12 26, 42 50 56 E32-D22 7 31, 43 49 58 E32-T81F-S 12 27, 42 50 56 E32-D221B 7 32, 43 49 59 E32-T81R-S 26, 42 50 56 E32-D22B 7 32, 43 49 59 E32-T84S-S 12 26, 42 50 56 33, 43 49 60 E32-T84SV 1M 13 28, 42 50 57 6 19, 41 49 51 19 49 51 19 49 51 19 49 51 E32-D22L E32-D22R 7 29 49 58 E32-TC200 E32-D24 7 31, 43 49 58 E32-TC200A E32-D24R 7 30 49 58 E32-TC200B E32-D25X 7 31, 43 49 58 E32-TC200B4 E32-D25XB 7 32, 43 49 60 E32-TC200B4R 18 18, 41 49 51 E32-D25XR 7 29 49 58 E32-TC200BR 6 18, 41 49 51 E32-D25Y 7 31, 43 49 59 E32-TC200E 6 19, 41 49 51 E32-D25YR 7 30 49 59 E32-TC200F 6 19, 41 49 51 E32-D25Z 7 31, 43 49 59 E32-TC200F4 19, 41 49 51 E32-D25ZR 7 30 49 59 E32-TC200F4R 18 49 51 34, 43 49 61 E32-TC200FR 6 18 49 51 E32-D32 98 Model 6 E32-D32L 9 34, 43 49 61 E3C-LD11 81 81 83 51 E32-D33 8 33 49 61 E3C-LD21 81 81 83 85 Model Features/ Applications Detecting Distance Ratings/ Characteristics Dimensions Model Features/ Applications Detecting Distance Ratings/ Characteristics Dimensions 81 E32-D331 8 33 49 61 E3C-LD31 81 83 85 E32-D36P1 10 35, 43 49 62 E3C-LDA11 82 84 85 E32-D36T 14 38 50 65 E3C-LDA11AN 82 84 94 E32-D51 36, 44 50 63 E3C-LDA21 82 84 94 E32-D61 37 50 64 E3C-LDA41 82 84 94 37, 44 50 64 E3C-LDA41AN 82 84 94 37 50 64 E3C-LDA51 82 84 94 37, 44 50 64 E3C-LDA6 82 84 94 37 50 63 E3C-LDA7 82 84 94 37, 44 50 63 E3C-LDA8 82 84 94 38 50 66 E3C-LDA9 82 84 94 38 50 66 E3C-LR11 81 81 83 94 81 83 85 E32-D61-S 12 E32-D73 E32-D73-S 12 E32-D81R E32-D81R-S E32-D82F1 14 E32-D82F2 E32-DC200 7 30, 43 49 58 E3C-LR12 81 E32-DC200B 7 30 49 58 E3X-DA11RW-S 75 76 85 30 49 58 E3X-DA11-S 75 76 92 29, 43 49 58 E3X-DA11TW-S 75 76 92 E32-DC200B4 9E32-DC200B4R E32-DC200BR 7 29, 43 49 58 E3X-DA41RW-S 75 76 92 E32-DC200E 7 31, 43 49 58 E3X-DA41-S 75 76 92 E32-DC200F 7 31, 43 49 58 E3X-DA41TW-S 75 76 92 E32-DC200F4 31, 43 49 58 E3X-DA6RW-S 75 76 93 E32-DC200F4R 29 49 58 E3X-DA6-S 75 76 93 29 49 58 E3X-DA6TW-S 75 76 93 E32-ET16WR-1 25 49 55 E3X-DA8RW-S 75 76 93 E32-ET16WR-2 25 49 55 76 93 E32-DC200FR 7 E3X-DA8-S 75 E32-G14 14 38, 42 50 65 E3X-DA8TW-S 75 76 93 E32-L16 11, 15 36, 39 50 62 E3X-DAB11-S 75 76 92 E32-L24L 11 36 49 62 E3X-DAB41-S 75 76 92 E32-L24S 11 35 49 62 E3X-DAB6-S 75 76 93 E32-L25 35 49 63 E3X-DAB8-S 75 76 93 E32-L25A 35 49 63 E3X-DAC11-S 79 80 92 36 49 62 E3X-DAC21-S 79 80 92 38 50 65 E3X-DAC41-S 79 80 92 E3X-DAC51-S 79 80 92 80 93 E32-L25L 11 E32-L25T E32-L66 15 39 50 66 E32-L86 11 36 49 63 E3X-DAC6-S 79 25 50 54 E3X-DAC8-S 79 80 93 E32-M21 E32-R16 11 35 49 62 E3X-DAG11-S 75 76 92 E32-R21 11 35 49 62 E3X-DAG41-S 75 76 92 E32-T10V 2M 13 E3X-DAG6-S 75 76 93 E32-T11 50 20, 41 49 52 E3X-DAG8-S 75 76 93 E32-T11F 12 26, 42 50 56 E3X-DRT21-S 88 89 97 E32-T11L 8 22, 41 49 53 E3X-MDA11 77 78 92 E32-T11N 6 20 49 53 E3X-MDA41 77 78 92 E32-T11R 6, 17 18, 41 49 51 E3X-MDA6 77 78 93 E32-T11U 6 21, 41 50 52 E3X-MDA8 77 78 93 E32-T12 6 19 49 51 E3X-NA11 73 74 90 E32-T12B 6 20, 41 49 52 E3X-NA11F 73 74 90 E32-T12F 12 27, 42 50 56 E3X-NA11V 73 74 91 22, 41 49 53 E3X-NA14V 73 74 91 E32-T12L E32-T12R 6 18, 41 49 51 E3X-NA41 73 74 90 E32-T14 8, 14 22, 38, 41 50 53 E3X-NA41F 73 74 90 E32-T14F 12 27, 42 50 56 E3X-NA41V 73 74 91 E32-T14L 6 19 49 51 E3X-NA44V 73 74 91 E32-T14LR 6 18, 41 49 51 E3X-NA6 73 74 90 E32-T15X 6 19 49 51 E3X-NA8 73 74 90 E32-T15XB 6 20, 41 49 52 E3X-SD11 73 74 90 E32-T15XR 6 18, 41 49 51 E3X-SD41 73 74 90 E32-T15Y 19 49 52 E3X-SD6 73 74 90 E32-T15YR 18, 41 49 52 E3X-SD8 73 74 90 19 49 52 E32-T15Z 6 99 OMRON ELECTRONICS LLC * THE AMERICAS HEADQUARTERS Schaumburg, IL USA * 847.843.7900 * 800.556.6766 * www.omron247.com OMRON CANADA, INC. * HEAD OFFICE OMRON ARGENTINA * SALES OFFICE Toronto, ON, Canada * 416.286.6465 * 866.986.6766 * www.omron.ca Cono Sur * 54.11.4783.5300 OMRON ELETRONICA DO BRASIL LTDA * HEAD OFFICE OMRON CHILE * SALES OFFICE Sao Paulo, SP, Brasil * 55.11.2101.6300 * www.omron.com.br Santiago 56.9.9917.3920 OMRON ELECTRONICS MEXICO SA DE CV * HEAD OFFICE OTHER OMRON LATIN AMERICA SALES Apodaca, N.L. * 52.811.156.99.10 * 001.800.556.6766 * mela@omron.com 54.11.4783.5300 E25I-E-01 Note: Specifications are subject to change. (c) 2008 Omron Electronics LLC Printed on recycled paper. Printed in U.S.A. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: E32-LD11R 2M E32-LT11 2M E32-LD11 2M E32-C21N 2M E32-LD11N 2M E32-D21N 5M E32-LT11N 2M E32LT11N 5M E32-C21N 5M E32-LD11N 5M E32-D21N 2M