Features Regulated Converters POWERLINE Very Compact AC-DC Power Supply 6 Watt PCB Mount Package Single and Dual Output Versions Universal Input Voltage Range Class II Power Supply with 3kVAC Isolation Low Output Ripple and Noise Short Circuit, Overload, Overtemp Protected Low Standby Power Consumption UL/cUL Certified, CE Marked AC/DC-Converter with 3 year Warranty 6 Watt Single/Dual Output Compact, low cost, high efficiency, universal input switching AC/DC power module for PCB or wired mounting with single or dual outputs. CE marked and UL/cUL Certified. Description Selection Guide Input Range (VAC) Output Voltage (VDC) Output Current (mA) Efficiency (%) Max Capacitive Load (1+2) RAC06-3.3SC* 80-264 3.3 1500 70 12000F RAC06-05SC* 80-264 5 1200 75 6800F RAC06-09SC* 80-264 9 667 77 2500F RAC06-12SC* 80-264 12 500 78 1500F RAC06-15SC* 80-264 15 400 79 750F RAC06-24SC* 80-264 24 250 79 330F RAC06-05DC* 80-264 5 600 75 3300F RAC06-12DC* 80-264 12 250 78 680F RAC06-15DC* 80-264 15 200 79 330F * add suffix /W for wired version 80-264VAC or 115-370VDC Rated Power 6 Watts max. Input Frequency Range (for AC Input) Input Current (full load) 47-440Hz 115/230VAC 250mW max. Inrush Current (<2ms) 115/230VAC Holdup Time (Full Load) 115VAC 30A/60A max. 10ms typ. Leakage Current 0.85mA max. Output Voltage Accuracy (Full load) 2% max. Line Voltage Regulation (low line, high line at full load) 0.3% typ. Load Voltage Regulation ( 5% to 100% full load ) Output Ripple and Noise (20MHz BW) 3.3V Output (with 100nF across each output) All Others 0.5% typ. 120mVp-p max. 150mVp-p max. Operating Frequency (full load) 132kHz typ. specifications valid for 5% minimum load only RMS Isolation Voltage (input to output) 3kVAC / 1minute Isolation Resistance (input to output) 1 G min. Isolation Capacitance (input to output) 1000pF typ. Short Circuit Protection Overload Protection RAC06-C 120mA / 78mA typ. No Load Power Consumption Minimum Load = 0% E224736 EN-60950-1 Certified UL-60950-1 Certified Specifications (measured at TA 25C, full load after warm-up) Input Voltage Range (with derating) RoHS 2011/65/EU 6/6 Hiccup, Automatic Restart 115VAC/230VAC Derating-Graph (Ambient Temperature) 125 Natural Convection 100 Output Power (%) Part Number 75 50 25 0 -25 0 75 85 95 60 55 70 Ambient Temperature Range (C) 115% ~ 145% Output Overvoltage Protection Zener Diode Clamp (set at 4.8V - 5.4V for 3.3V and others 110% - 135% of its Nominal Output Voltage) Over Voltage Category OVC II continued on next page www.recom-power.com REV: 0/2015 Refer to Application Notes PA-33 RAC06-S_DC Series POWERLINE AC/DC-Converter Specifications (measured at TA 25C, full load after warm-up) (3) (free air convection, without derating) (free air convection, with derating) Storage Temperature Range Emissions RAC06 Immunity MTBF (+25C) (+65C) Certifications: UL General Safety cUL EN General Safety CE Single Output Efficiency / Load 100 -40C to +100C 9V, 12V 80 1.5A Slow Blow 95% RH max. Plastic Case filled with Epoxy (UL94V-0) Single/Dual 35g/38g Single Output 10 pcs Dual Output 9 pcs /W Version 1 pc CE EN 55022: 2006 + A1: 2007 / Class B EMC EN 55024:1998 + A1:2001 + A2:2003 Harmonics EN 61000-3-2:2006 / Class A Flicker EN 61000-3-3:1995 + A1:2001 +A2:2005 ESD IEC 61000-4-2 / Criterion B RS IEC 61000-4-3 / Criterion A EFT IEC 61000-4-4 / Criterion B Surge IEC 61000-4-5 / Criterion B CS IEC 61000-4-6 / Criterion A PMF IEC 61000-4-8 / Criterion A Voltage Variations IEC 61000-4-11 / Criteria B + C using MIL-HDBK-217F >400 x 103 hours >200 x 103 hours Efficiency % Recommended External Input Fuse Humidity Case Material Package Weight Packing Quantity -25C to +55C -25C to +75C 15V, 24V 5V 3.3V 60 40 20 0 0% 40% 80% 60% Total Output current (%) 20% 100% Dual Output Efficiency / Load 100 80 Efficiency % Operating Temperature Range 12V, 15V 5V 60 40 20 0 0% 40% 80% 60% Total Output current (%) 20% 100% Input Voltage Derating Graph 90V, 100% 100% 90% Load (%) Report: E224736 UL-60950-1, 2nd Edition Report: E224736 C22.2 No. 60950-1-07, 2nd Edition Report: SPCLVD1211033-1 EN-60950-1:2006 + A12:2011 EN55022 Class B 80% 70% Notes: Note1: Measured @ 230VAC / 50Hz / Ta=25C with constant resistant mode at full load. Note2: If used @ 115VAC / 60Hz with full load, max. capacitive load is less, please contact RECOM for detailed information. Note3: Start up only is guaranteed at temperatures down to -25C. Other specifications may not be met. 264V, 100% Safe Operating Area 80V, 80% 80 130 180 230 280 Input Voltage (VAC) Ta=25C Package Style and Pinning PCB Mounting Version (Standard) Pin Connections 50.9 (single) 53.5 (dual) 25.5 (single) 27.8 (dual) 15.65 6.1 16.40+0.25 - Standoffs = 0.75+0.25 - 1.0 45.72 20.32 12.75 (single) 13.90 (dual) 1.2o+0.2/0.1 2 (5) 3 1 10.16 10.16 Bottom View 4 Leave Clear of PCB Traces 2.54 10.16 10.16 1 (5) 2 3 2.54 Wired Version (Suffix /W) 50.9 (single) 53.5 (dual) 4 Top View 10 15 Recommended Footprint Details 15.65 88 AWG#22 Pin # Single Out Dual Out 1 VAC in (N) VAC in (N) 2 VAC in (L) VAC in (L) 3 +VDC out +VDC out 4 -VDC out Com 5 No Pin -VDC out Tolerance 0.5 mm Wire Connections Wire AWG#22 Single Out Dual Out Blue 1015 VAC in (N) Brown 1015 VAC in (L) VAC in (L) Red 1007 +VDC out +VDC out Black 1007 -VDC out Orange 1007 VAC in (N) Com -VDC out 10 stripped and tinned The product information and specifications are subject to change without prior notice. All products are designed for non-safety critical commercial and industrial applications. The Buyer agrees to implement safeguards that anticipate the consequences of any failures that might cause harm, loss of life and/or damage property. PA-34 REV: 0/2015 www.recom-power.com Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: RECOM: RAC06-05DC RAC06-05DC/W RAC06-05SC RAC06-05SC/W RAC06-09SC RAC06-09SC/W RAC06-12DC RAC06-12DC/W RAC06-12SC RAC06-12SC/W RAC06-15DC RAC06-15DC/W RAC06-15SC RAC06-15SC/W RAC06-24SC RAC06-24SC/W RAC06-3.3SC RAC06-3.3SC/W