PR26MF1xNSZ Series
PR36MF1xNSZ Series
Features
IT(rms)0.6A, Non-Zero Cross type
DIP 8pin
Triac output SSR
1. Output current, IT(rms)0.6A
2. Non-zero crossing functionary
3. 8 pin DIP package (SMT gullwing also available)
4. High repetitive peak off-state voltage
(VDRM : 600V, PR36MF1xNSZ Series)
(VDRM : 400V, PR26MF1xNSZ Series)
5. IFT ranks available (see Model Line-up in this
datasheet)
6. Superior noise immunity (dV/dt : MIN. 100V/µs)
7. Response time, ton : MAX. 100µs
8. Lead-free terminal components are also available
(see Model Line-up section in this datasheet)
9. High isolation voltage between input and output
(Viso(rms) : 4.0kV)
Description
PR26MF1xNSZ Series and PR36MF1xNSZ Series
Solid State Relays (SSR) are an integration of an
infrared emitting diode (IRED), a Phototriac Detector
and a main output Triac. These devices are ideally
suited for controlling high voltage AC loads with solid
state reliability while providing 4.0kV isolation
(Viso(rms)) from input to output.
1
Notice The content of data sheet is subject to change without prior notice.
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP
devices shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.
PR26MF1xNSZ Series
PR36MF1xNSZ Series
Sheet No.: D4-A00401EN
Date Mar. 31. 2004
© SHARP Corporation
Agency approvals/Compliance
1. Isolated interface between high voltage AC devices
and lower voltage DC control circuitry.
2. Switching motors, fans, heaters, solenoids, and
valves.
3. Phase or power control in applications such as
lighting and temperature control equipment.
Applications
1. Recognized by UL508, file No. E94758 (as model No.
R26MF1/R36MF1)
2. Approved by CSA 22.2 No.14, file No. LR63705 (as
model No. R26MF1/R36MF1)
3.
Optionary available VDE approved
()(
DIN EN 60747-5-
2), file No. 40008898 (only for PR36MF1xNSZ Series
as model No. R36MF1)
4. Package resin : UL flammability grade (94V-0)
()DIN EN60747-5-2 : successor standard of DIN VDE0884.
Up to Date code "RD" (December 2003), approval of DIN
VDE0884.
From Date code "S1" (January 2004), approval of DIN
EN60747-5-2.
Zero cross type is also available. (PR26MF21NSZ Series/
PR36MF2xNSZ Series)
Internal Connection Diagram
1
68
1 2 3 4
5
2
3
4
Cathode
Anode
Cathode
Cathode
5
6
8
Gate
Output (T1)
Output (T2)
2
Outline Dimensions (Unit : mm)
1. Through-Hole [ex. PR26MF11NSZF] 2. SMT Gullwing Lead-Form [ex. PR26MF11NIPF]
2.54±0.25
8 6 5
6.5±0.5
1.05±0.2
1.2±0.3
9.66±0.5
3.5
±0.5
0.5±0.1
1 2 3 4
3.25±0.5
0.5TYP.
θ θ
θ:0 to 13˚
7.62±0.3
0.26±0.1
Epoxy resin
R26MF1
Anode
mark
Date code (2 digit)
Rank
mark
Factory identification mark
SHARP
mark
"S"
CSA mark
Model No. 8 6 5
6.5±0.5
2.54±0.25
3.5±0.5
1.0+0.4
0
0.26±0.1
Epoxy resin
10.0+0
0.5
1.0+0.4
0
0.35±0.25
7.62±0.3
9.66±0.5
4
1 2 3
1.05±0.2
1.2±0.3
R26MF1
Anode
mark
Date code (2 digit)
Rank
mark
Factory identification mark
SHARP
mark
"S"
CSA mark
Model No.
3. Through-Hole [ex. PR36MF11NSZF] 4. SMT Gullwing Lead-Form [ex. PR36MF11NIPF]
PR26MF1xNSZ Series
PR36MF1xNSZ Series
Sheet No.: D4-A00401EN
2.54±0.25
8 6 5
6.5±0.5
1.05±0.2
1.2±0.3
9.66±0.5
3.5
±0.5
0.5±0.1
1 2 3 4
3.25±0.5
0.5TYP.
θ θ
θ:0 to 13˚
7.62±0.3
0.26±0.1
Epoxy resin
R36MF1
Anode
mark
Date code (2 digit)
Rank
mark
Factory identification mark
SHARP
mark
"S"
CSA mark
Model No. 8
6.5±0.5
2.54±0.25
3.5±0.5
1.0+0.4
0
0.26±0.1
Epoxy resin
10.0+0
0.5
1.0+0.4
0
0.35±0.25
7.62±0.3
9.66±0.5
4
1 2 3
1.05±0.2
1.2±0.3
6 5
R36MF1
Anode
mark
Date code (2 digit)
Rank
mark
Factory identification mark
SHARP
mark
"S"
CSA mark
Model No.
Product mass : approx. 0.54gProduct mass : approx. 0.56g
Product mass : approx. 0.54gProduct mass : approx. 0.56g
3
Outline Dimensions (Unit : mm)
5.
Through-Hole VDE option [ex. PR36MF11YSZF]
6.
SMT Gullwing Lead-Form VDE option [ex. PR36MF11YIPF]
PR26MF1xNSZ Series
PR36MF1xNSZ Series
Sheet No.: D4-A00401EN
2.54±0.25
8 6 5
6.5±0.5
1.05±0.2
1.2±0.3
9.66±0.5
3.5
±0.5
0.5±0.1
1 2 3 4
3.25±0.5
0.5TYP.
θ θ
θ:0 to 13˚
7.62±0.3
0.26±0.1
Epoxy resin
R36MF1
Anode
mark
Date code (2 digit)
Rank
mark
Factory identification mark
SHARP
mark
"S"
CSA mark
Model No.
4
VDE identification mark
8
6.5±0.5
2.54±0.25
3.5±0.5
1.0+0.4
0
0.26±0.1
Epoxy resin
10.0+0
0.5
1.0+0.4
0
0.35±0.25
7.62±0.3
9.66±0.5
4
1 2 3
1.05±0.2
1.2±0.3
6 5
R36MF1
Anode
mark
Date code (2 digit)
Rank
mark
Factory identification mark
SHARP
mark
"S"
CSA mark
Model No.
4
VDE identification mark
Product mass : approx. 0.54gProduct mass : approx. 0.56g
Date code (2 digit)
Rank mark
Please refer to the Model Line-up table.
A.D.
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
Mark
A
B
C
D
E
F
H
J
K
L
M
N
Mark
P
R
S
T
U
V
W
X
A
B
C
Mark
1
2
3
4
5
6
7
8
9
O
N
D
Month
January
February
March
April
May
June
July
August
September
October
November
December
A.D
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
·
·
··
·
·
2nd digit
Month of production
1st digit
Year of production
Factory identification mark
Factory identification Mark
no mark
Country of origin
Japan
* This factory marking is for identification purpose only.
Please contact the local SHARP sales representative to see the actural status of the
production.
4
repeats in a 20 year cycle
PR26MF1xNSZ Series
PR36MF1xNSZ Series
Sheet No.: D4-A00401EN
Electro-optical Characteristics
Parameter Symbol Unit
Input
Output
(Ta=25˚C)
Forward voltage
Reverse current
Repetitive peak OFF-state current
ON-state voltage
Holding current
Critical rate of rise of OFF-state voltage
Minimum trigger current
Isolation resistance
Turn-on time
VF
IR
IDRM
VT
IH
dV/dt
IFT
RISO
ton
V
µA
µA
V
mA
V/µs
mA
µs
IF=20mA
VR=3V
VD=VDRM
IT=0.6A
VD=6V
VD=1/
2 ·VDRM
VD=6V, RL=100
DC500V,40 to 60%RH
V
D=
6V, R
L=
100, I
F=
20mA
V
D=
6V, R
L=
100, I
F=
10mA
Conditions
100
5
×
1010
1.2
1011
1.4
10
100
3.0
25
10
5
100
MIN. TYP. MAX.
Transfer
charac-
teristics
Rank 1
Rank 2
Rank 1
Rank 2
Absolute Maximum Ratings
5
Parameter Symbol Rating Unit
Input
Output
(Ta=25˚C)
Forward current
Reverse voltage
RMS ON-state current
Peak one cycle surge current
Repetitive
peak OFF-state voltage
Isolation voltage
Operating temperature
Storage temperature
Soldering temperature
*2
*1
IF
VR
IT(rms)
Isurge
VDRM
Viso(rms)
Topr
Tstg
Tsol
mA
V
A
A
V
kV
˚C
˚C
˚C
*4
*3
*3
*5
50
6
0.6
6
400
600
4.0
25 to +85
40 to +125
270
*1 40 to 60%RH, AC for 1minute, f=60Hz
*2 For 10s
*3 Refer to Fig.1, Fig.2
*4 f=50Hz sine wave
*5 Lead solder plating models: 260˚C
PR26MF1xNSZ
PR36MF1xNSZ
PR26MF1xNSZ Series
PR36MF1xNSZ Series
1mm
Soldering area
Sheet No.: D4-A00401EN
Lead Form
Shipping Package
DIN
EN60747-5-2
Model No.
Through-Hole
Sleeve
50pcs/sleeve
Taping
1 000pcs/reel
PR36MF12NSZF
SMT Gullwing
PR36MF12NIPF
PR36MF11NSZF
PR36MF12YSZF
PR36MF11YSZF PR36MF11NIPF
PR36MF12YIPF
PR36MF11YIPF
-
Approved
-
Approved
IFT[mA]
(VD=6V,
RL=100)
PR26MF12NSZF PR26MF12NIPF
PR26MF11NSZF
-
-
PR26MF11NIPF
-
-
Rank mark
MAX.5
MAX.10
600
VDRM
[V]
2
1
MAX.5
MAX.10
400 2
1
6
Please contact a local SHARP sales representative to see the actual status of the production.
PR26MF1xNSZ Series
PR36MF1xNSZ Series
Sheet No.: D4-A00401EN
Model Line-up (1) (Lead-free terminal components)
Model Line-up (2) (Lead solder plating components)
Lead Form
Shipping Package
DIN
EN60747-5-2
Model No.
Through-Hole
Sleeve
50pcs/sleeve
Taping
1 000pcs/reel
PR36MF12NSZ
SMT Gullwing
PR36MF12NIP
PR36MF11NSZ
PR36MF12YSZ
PR36MF11YSZ PR36MF11NIP
PR36MF12YIP
PR36MF11YIP
-
Approved
-
Approved
IFT[mA]
(VD=6V,
RL=100)
PR26MF12NSZ PR26MF12NIP
PR26MF11NSZ
-
-
PR26MF11NIP
-
-
Rank mark
MAX.5
MAX.10
600
VDRM
[V]
2
1
MAX.5
MAX.10
400 2
1
7
PR26MF1xNSZ Series
PR36MF1xNSZ Series
0
10
20
30
40
50
60
70
Forward current IF (mA)
Ambient temperature Ta (˚C)
25 0 50 100
Fig.1 Forward Current vs. Ambient
Temperature
Fig.2 RMS ON-state Current vs.
Ambient Temperature
Sheet No.: D4-A00401EN
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
25 0 50 100
RMS ON-state current IT (rms) (A)
Ambient temperature Ta (˚C)
50
5
1
100
10
0.5011.5 2 2.5 3
25˚C
50˚C
25˚C 0˚C
Forward current IF (mA)
Forward voltage VF (V)
Ta=75˚C
Fig.3-a Forward Current vs.
Forward Voltage (Rank 1)
Fig.4-a Minimum Trigger Current vs.
Ambient Temperature (Rank 1)
Fig.3-b Forward Current vs.
Forward Voltage (Rank 2)
Fig.4-b Minimum Trigger Current vs.
Ambient Temperature (Rank 2)
0
2
4
6
8
12
10
40 20 0 20 406080100
Minimum trigger current IFT (mA)
Ambient temperature Ta (˚C)
VD=6V
RL=100
PR26MF11NSZ
PR36MF11NSZ
50
5
1
100
10
Forward current IF (mA)
Forward voltage VF (V)
25˚C
25˚C 0˚C
Ta=75˚C
50˚C
10.9 1.1 1.2 1.3 1.4 1.5
0
1
2
3
4
6
5
Minimum trigger current IFT (mA)
Ambient temperature Ta (˚C)
VD=6V
RL=100
30 0 10050
8
PR26MF1xNSZ Series
PR36MF1xNSZ Series
Fig.8-a Turn-on Time vs. Forward Current
(Rank 1)
Fig.8-b Turn-on Time vs. Forward Current
(Rank 2)
Sheet No.: D4-A00401EN
Fig.7 ON-state Current vs. ON-state Voltage
1 000
10
100
1
100
VD=6V
RL=100
Ta=25˚C
10 20 30 40 50
Forward current IF (mA)
Turn-on time tON (µs)
PR36MF11NSZ
PR26MF11NSZ
0
0.2
0.4
0.6
0.8
1
1.2
00.511.5 2
ON-state current IT (A)
ON-state voltage VT (V)
IF=20mA
Ta=25˚C
1 000
100
10
1
100
VD=6V
RL=100
Ta=25˚C
110
Forward current IF (mA)
Turn-on time tON (µs)
Fig.5 ON-state Voltage vs.
Ambient Temperature
Fig.6 Relative Holding Current vs.
Ambient Temperature
1
1.2
1.1
1.4
1.3
1.5
1.6
40 020 20 40 60 80 120100
ON-state voltage VT (V)
Ambient temperature Ta (˚C)
IT=0.6A
10
100
1 000
30 0 20 40 60 80 100
Relative holding current I
H
(t˚C) / I
H
(25˚C)×100%
Ambient temperature Ta (˚C)
VD=6V
Remarks : Please be aware that all data in the graph
are just for reference.
9
PR26MF1xNSZ Series
PR36MF1xNSZ Series
Design Considerations
In order for the SSR to turn off, the triggering current (IF) must be 0.1mA or less.
In phase control applications or where the SSR is being by a pulse signal, please ensure that the pulse width
is a minimum of 1ms.
When the input current (IF) is below 0.1mA, the output Triac will be in the open circuit mode. However, if the
voltage across the Triac, VD, increases faster than rated dV/dt, the Triac may turn on. To avoid this situation,
please incorporate a snubber circuit. Due to the many different types of load that can be driven, we can
merely recommend some circuit values to start with : Cs=0.022µF and Rs=47. The operation of the SSR
and snubber circuit should be tested and if unintentional switching occurs, please adjust the snubber circuit
component values accordingly.
When making the transition from On to Off state, a snubber circuit should be used ensure that sudden drops
in current are not accompanied by large instantaneous changes in voltage across the Triac.
This fast change in voltage is brought about by the phase difference between current and voltage.
Primarily, this is experienced in driving loads which are inductive such as motors and solenods.
Following the procedure outlined above should provide sufficient results.
Any snubber or Varistor used for the above mentioned scenarios should be located as close to the main
output triac as possible.
All pins shall be used by soldering on the board. (Socket and others shall not be used.)
Degradation
In general, the emission of the IRED used in SSR will degrade over time.
In the case where long term operation and / or constant extreme temperature fluctuations will be applied to
the devices, please allow for a worst case scenario of 50% degradation over 5years.
Therefore in order to maintain proper operation, a design implementing these SSRs should provide at least
twice the minimum required triggering current from initial operation.
Design guide
Sheet No.: D4-A00401EN
Recommended Operating Conditions
Parameter
PR26MF1xNSZ
PR36MF1xNSZ
Symbol Unit
Input
Output
Input signal current
at ON state
Input signal current at OFF state
Load supply voltage
Load supply current
Frequency
Operating temperature
IF(ON)
IF(OFF)
VOUT(rms)
IOUT(rms)
f
Topr
mA
mA
V
mA
Hz
˚C
Locate snubber circuit between output terminals
(Cs=0.022µF, Rs=47)
Conditions
20
10
0
50
20
25
15
0.1
120
240
IT(rms)×80%()
60
80
MIN. MAX.
() See Fig.2 about derating curve (IT(rms) vs. ambient temperature).
Rank 1
Rank 2
10
PR26MF1xNSZ Series
PR36MF1xNSZ Series
For additional design assistance, please review our corresponding Optoelectronic Application Notes.
Standard Circuit
Tr1
R1
D1
V1
+VCC
AC Line
Load
ZS
ZS : Surge absorption circuit (Snubber circuit)
SSR
82
36
Sheet No.: D4-A00401EN
Recommended Foot Print (reference)
SMT Gullwing Lead-form
2.542.54
1.7
2.2
8.2
2.54
(Unit : mm)
Manufacturing Guidelines
Reflow Soldering:
Reflow soldering should follow the temperature profile shown below.
Soldering should not exceed the curve of temperature profile and time.
Please don't solder more than twice.
Soldering Method
Flow Soldering :
Flow soldering should be completed below 270˚C and within 10s.
Preheating is within the bounds of 100 to 150˚C and 30 to 80s.
Please don't solder more than twice.
Hand soldering
Hand soldering should be completed within 3s when the point of solder iron is below 400˚C.
Please don't solder more than twice.
Other notices
Please test the soldering method in actual condition and make sure the soldering works fine, since the impact
on the junction between the device and PCB varies depending on the tooling and soldering conditions.
11
1234
300
200
100
00
(˚C)
Terminal : 260˚C peak
( package surface : 250˚C peak)
Preheat
150 to 180˚C, 120s or less
Reflow
220˚C or more, 60s or less
(min)
PR26MF1xNSZ Series
PR36MF1xNSZ Series
Sheet No.: D4-A00401EN
12
PR26MF1xNSZ Series
PR36MF1xNSZ Series
Sheet No.: D4-A00401EN
Solvent cleaning :
Solvent temperature should be 45˚C or below. Immersion time should be 3minutes or less.
Ultrasonic cleaning :
The impact on the device varies depending on the size of the cleaning bath, ultrasonic output, cleaning time,
size of PCB and mounting method of the device.
Therefore, please make sure the device withstands the ultrasonic cleaning in actual conditions in advance of
mass production.
Recommended solvent materials :
Ethyl alcohol, Methyl alcohol and Isopropyl alcohol.
In case the other type of solvent materials are intended to be used, please make sure they work fine in
actual using conditions since some materials may erode the packaging resin.
Cleaning instructions
This product shall not contain the following materials.
And they are not used in the production process for this device.
Regulation substances : CFCs, Halon, Carbon tetrachloride, 1.1.1-Trichloroethane (Methylchloroform)
Specific brominated flame retardants such as the PBBOs and PBBs are not used in this product at all.
Presence of ODC
Package specification
13
12.0
6.7
5.8
10.8
520
±2
Sleeve package
Through-Hole
Package materials
Sleeve : HIPS (with anti-static material)
Stopper : Styrene-Elastomer
Package method
MAX. 50pcs of products shall be packaged in a sleeve.
Both ends shall be closed by tabbed and tabless stoppers.
The product shall be arranged in the sleeve with its anode mark on the tabless stopper side.
MAX. 20 sleeves in one case.
Sleeve outline dimensions
(Unit : mm)
PR26MF1xNSZ Series
PR36MF1xNSZ Series
Sheet No.: D4-A00401EN
14
Tape and Reel package
SMT Gullwing
Package materials
Carrier tape : A-PET (with anti-static material)
Cover tape : PET (three layer system)
Reel : PS
Carrier tape structure and Dimensions
F
K
EI
DJ
G
B
H
A
C
Dimensions List (Unit : mm)
A
16.0±0.3
B
7.5±0.1
C
1.75±0.1
D
12.0±0.1
E
2.0±0.1
H
10.4±0.1
I
0.4±0.05
J
4.2±0.1
K
10.2±0.1
F
4.0±0.1
G
φ1.5+0.1
0
MAX.
H
a
c
e
g
f
b
d
Dimensions List (Unit : mm)
a
330
b
17.5±1.5
c
100±1.0
d
13±0.5
e
23±1.0
f
2.0±0.5
g
2.0±0.5
Pull-out direction
[Packing : 1 000pcs/reel]
Reel structure and Dimensions
Direction of product insertion
PR26MF1xNSZ Series
PR36MF1xNSZ Series
Sheet No.: D4-A00401EN
· The circuit application examples in this publication are
provided to explain representative applications of
SHARP devices and are not intended to guarantee any
circuit design or license any intellectual property rights.
SHARP takes no responsibility for any problems rela-
ted to any intellectual property right of a third party re-
sulting from the use of SHARP's devices.
· Contact SHARP in order to obtain the latest device
specification sheets before using any SHARP device.
SHARP reserves the right to make changes in the spec-
ifications, characteristics, data, materials, structure,
and other contents described herein at any time without
notice in order to improve design or reliability. Manufac-
turing locations are also subject to change without no-
tice.
· Observe the following points when using any devices
in this publication. SHARP takes no responsibility for
damage caused by improper use of the devices which
does not meet the conditions and absolute maximum
ratings to be used specified in the relevant specification
sheet nor meet the following conditions:
(i) The devices in this publication are designed for use
in general electronic equipment designs such as:
--- Personal computers
--- Office automation equipment
--- Telecommunication equipment [terminal]
--- Test and measurement equipment
--- Industrial control
--- Audio visual equipment
--- Consumer electronics
(ii) Measures such as fail-safe function and redundant
design should be taken to ensure reliability and safety
when SHARP devices are used for or in connection
with equipment that requires higher reliability such as:
--- Transportation control and safety equipment (i.e.,
aircraft, trains, automobiles, etc.)
--- Traffic signals
--- Gas leakage sensor breakers
--- Alarm equipment
--- Various safety devices, etc.
(iii) SHARP devices shall not be used for or in connec-
tion with equipment that requires an extremely high lev-
el of reliability and safety such as:
--- Space applications
--- Telecommunication equipment [trunk lines]
--- Nuclear power control equipment
--- Medical and other life support equipment (e.g.,
scuba).
· If the SHARP devices listed in this publication fall with-
in the scope of strategic products described in the For-
eign Exchange and Foreign Trade Law of Japan, it is
necessary to obtain approval to export such SHARP de-
vices.
· This publication is the proprietary product of SHARP
and is copyrighted, with all rights reserved. Under the
copyright laws, no part of this publication may be repro-
duced or transmitted in any form or by any means, elec-
tronic or mechanical, for any purpose, in whole or in
part, without the express written permission of SHARP.
Express written permission is also required before any
use of this publication may be made by a third party.
· Contact and consult with a SHARP representative if
there are any questions about the contents of this pub-
lication.
15
Important Notices
PR26MF1xNSZ Series
PR36MF1xNSZ Series
Sheet No.: D4-A00401EN