MULTI-RANGE ANALOG TIMER S1DXM-A/M RoHS compliance Features * Multiple functions built in * Part No. consolidation (The lineup consists of 64 easy-tochoose models.) * Cadmium-free contacts used * Economically priced * Operation mode and time range switches are on front panel. (Operation mode switch on S1DXM-M series only.) Time selectable Mode selectable Product types S1DXM-A multi-range timer No MODE switch, Operation mode (fixed): Power ON-delay Operating voltage 12V DC 24V DC 24V AC *Note 100 to 120V AC 200 to 220V AC 220 to 240V AC *Note Time range 0.05 s to 10 min 0.2 s to 30 min 0.5 s to 60 min 0.05 min to 10 hr 0.05 s to 10 min 0.2 s to 30 min 0.5 s to 60 min 0.05 min to 10 hr 0.05 s to 10 min 0.2 s to 30 min 0.5 s to 60 min 0.05 min to 10 hr 0.05 s to 10 min 0.2 s to 30 min 0.5 s to 60 min 0.05 min to 10 hr 0.05 s to 10 min 0.2 s to 30 min 0.5 s to 60 min 0.05 min to 10 hr 0.05 s to 10 min 0.2 s to 30 min 0.5 s to 60 min 0.05 min to 10 hr Timed-out 2 Form C Part No. S1DXM-A2C10M-DC12V S1DXM-A2C30M-DC12V S1DXM-A2C60M-DC12V S1DXM-A2C10H-DC12V S1DXM-A2C10M-DC24V S1DXM-A2C30M-DC24V S1DXM-A2C60M-DC24V S1DXM-A2C10H-DC24V S1DXM-A2C10M-AC24V S1DXM-A2C30M-AC24V S1DXM-A2C60M-AC24V S1DXM-A2C10H-AC24V S1DXM-A2C10M-AC120V S1DXM-A2C30M-AC120V S1DXM-A2C60M-AC120V S1DXM-A2C10H-AC120V S1DXM-A2C10M-AC220V S1DXM-A2C30M-AC220V S1DXM-A2C60M-AC220V S1DXM-A2C10H-AC220V S1DXM-A2C10M-AC240V S1DXM-A2C30M-AC240V S1DXM-A2C60M-AC240V S1DXM-A2C10H-AC240V Note: 48 V DC, 100 to 110 V DC, 24 V AC and 220 to 240 V AC types are made to order. Please inquire for details. A socket line holding clip (ADX28005) is not included with the product. Please purchase separately. All Rights Reserved (c) COPYRIGHT Panasonic Electric Works Co., Ltd. Timed-out 4 Form C Part No. S1DXM-A4C10M-DC12V S1DXM-A4C30M-DC12V S1DXM-A4C60M-DC12V S1DXM-A4C10H-DC12V S1DXM-A4C10M-DC24V S1DXM-A4C30M-DC24V S1DXM-A4C60M-DC24V S1DXM-A4C10H-DC24V S1DXM-A4C10M-AC24V S1DXM-A4C30M-AC24V S1DXM-A4C60M-AC24V S1DXM-A4C10H-AC24V S1DXM-A4C10M-AC120V S1DXM-A4C30M-AC120V S1DXM-A4C60M-AC120V S1DXM-A4C10H-AC120V S1DXM-A4C10M-AC220V S1DXM-A4C30M-AC220V S1DXM-A4C60M-AC220V S1DXM-A4C10H-AC220V S1DXM-A4C10M-AC240V S1DXM-A4C30M-AC240V S1DXM-A4C60M-AC240V S1DXM-A4C10H-AC240V IP40 Timers S1DXM-A/M S1DXM-A/M S1DXM-M multi-range timer With MODE switch, Operation mode (switchable): Power ON-delay, Power Flicker OFF start, Power Flicker ON start, Power One-shot Timers Operating voltage 12V DC 24V DC 24V AC *Note 100 to 120V AC 200 to 220V AC 220 to 240V AC *Note Time range 0.05 s to 10 min 0.2 s to 30 min 0.5 s to 60 min 0.05 min to 10 hr 0.05 s to 10 min 0.2 s to 30 min 0.5 s to 60 min 0.05 min to 10 hr 0.05 s to 10 min 0.2 s to 30 min 0.5 s to 60 min 0.05 min to 10 hr 0.05 s to 10 min 0.2 s to 30 min 0.5 s to 60 min 0.05 min to 10 hr 0.05 s to 10 min 0.2 s to 30 min 0.5 s to 60 min 0.05 min to 10 hr 0.05 s to 10 min 0.2 s to 30 min 0.5 s to 60 min 0.05 min to 10 hr Timed-out 2 Form C Part No. S1DXM-M2C10M-DC12V S1DXM-M2C30M-DC12V S1DXM-M2C60M-DC12V S1DXM-M2C10H-DC12V S1DXM-M2C10M-DC24V S1DXM-M2C30M-DC24V S1DXM-M2C60M-DC24V S1DXM-M2C10H-DC24V S1DXM-M2C10M-AC24V S1DXM-M2C30M-AC24V S1DXM-M2C60M-AC24V S1DXM-M2C10H-AC24V S1DXM-M2C10M-AC120V S1DXM-M2C30M-AC120V S1DXM-M2C60M-AC120V S1DXM-M2C10H-AC120V S1DXM-M2C10M-AC220V S1DXM-M2C30M-AC220V S1DXM-M2C60M-AC220V S1DXM-M2C10H-AC220V S1DXM-M2C10M-AC240V S1DXM-M2C30M-AC240V S1DXM-M2C60M-AC240V S1DXM-M2C10H-AC240V Timed-out 4 Form C Part No. S1DXM-M4C10M-DC12V S1DXM-M4C30M-DC12V S1DXM-M4C60M-DC12V S1DXM-M4C10H-DC12V S1DXM-M4C10M-DC24V S1DXM-M4C30M-DC24V S1DXM-M4C60M-DC24V S1DXM-M4C10H-DC24V S1DXM-M4C10M-AC24V S1DXM-M4C30M-AC24V S1DXM-M4C60M-AC24V S1DXM-M4C10H-AC24V S1DXM-M4C10M-AC120V S1DXM-M4C30M-AC120V S1DXM-M4C60M-AC120V S1DXM-M4C10H-AC120V S1DXM-M4C10M-AC220V S1DXM-M4C30M-AC220V S1DXM-M4C60M-AC220V S1DXM-M4C10H-AC220V S1DXM-M4C10M-AC240V S1DXM-M4C30M-AC240V S1DXM-M4C60M-AC240V S1DXM-M4C10H-AC240V Note: 48 V DC, 100 to 110 V DC, 24 V AC and 220 to 240 V AC types are made to order. Please inquire for details. A socket line holding clip (ADX28005) is not included with the product. Please purchase separately. All Rights Reserved (c) COPYRIGHT Panasonic Electric Works Co., Ltd. S1DXM-A/M Specifications Item Rated operating voltage Rated frequency Rated power consumption Rating Specifications 100 to 120VAC 200 to 220VAC 220 to 240VAC 12VDC 24VDC 50/60Hz common -- Max. 3 VA Max. 3 VA Max. 3 VA Max. 3 VA Max. 2 W Max. 2 W (at 24 VAC) (at 100 VAC) (at 200 VAC) (at 220 VAC) (at 12 VDC) (at 24 VDC) Approx. 3mA Approx. 3mA Approx. 3mA Approx. 3mA Approx. 5mA Approx. 3mA Approx. 80mA Approx. 20mA Approx. 13mA Approx. 13mA Approx. 70mA Approx. 40mA Timed -out 2 Form C: 7A 250V AC (resistive load) Timed -out 4 Form C: 5A 250V AC (resistive load) S1DXM-A Power on delay operation fixed (Power display: ON/green; Operation display (when output is on): UP/orange) S1DXM-M 4 switchable operations: Power ON-delay/Power Flicker OFF start/Power Flicker ON start/Power One-shot (Power display: ON/green; Operation display (when output is on): UP/orange) During time delay After time delay Rated control capacity Operation mode Time accuracy*1 Contact Life Mechanical Operating time fluctuation & Power off time change error Voltage error Temperature error Setting error Contact arrangement Contact resistance (Initial value) Within 1%, (power off time change at the range of 0.1 s to 1 h), 1 s range: Max. 1% and 10 ms*2 Within 1% (at the operating voltage changes between -20 to +10%), 1 s range: Max. 1% and 10 ms*2 Within 5% (at 20C 68F ambient temp. at the range of -10 to +50C +14 to +122F) Within 10%, 1 s range: Max. 10% and 20 ms Timed-out 2 Form C, Timed-out 4 Form C Max. 100m (at 1A, 6V DC) Timed-out 2 Form C type: Silver alloy, Au plating Contact material Timed-out 4 Form C type: Silver alloy, Au plating Mechanical (constant) Min. 107 Electrical (constant) 2x105 (at rated control capacity) Functional 10 to 55Hz: 1 cycle/min single amplitude of 0.25mm (10min on 3 axes) Vibration resistance Destructive 10 to 55Hz: 1 cycle/min single amplitude of 0.375mm (1h on 3 axes) Functional Min. 98m/s2 (4 times on 3 axes) Shock resistance Destructive Min. 980m/s2 (5 times on 3 axes) Allowable operating voltage range 19.2 to 26.4 V DC 80 to 132 V AC 160 to 242 V AC 176 to 264 V AC 9.6 to 13.2 V DC 19.2 to 26.4 V DC Reset time Max. 0.1s Insulation resistance (Initial value) Electrical Breakdown voltage (Initial value) Operating conditions Temperature rise Ambient temperature Ambient humidity Air pressure Ripple factor Mass (Weight) Protective construction Between live and dead metal parts, between input and output, between contact sets, between contacts Min. 100 M (at 500 V DC megger) Between live and dead metal parts: 2,000 Vrms for 1 min Between input and output: 2,000 Vrms for 1 min Between contact sets: 2,000 Vrms for 1 min Between contacts: 1,000 Vrms for 1 min Max. 70C 158F -10 to 50C +14 to 122F 30 to 85% RH (non-condensing) 860 to 1060 hPa DC type only, transmission wave rectification (ripple factor: approx. 48%)*3 Approx. 45 g IEC standard: IP40 (IP50 when using ADX18008 protective cover) Notes: *1. Unspecified measuring conditions are rated operating voltage (in case of DC type, ripple rate of 5% or less), ambient temp. 20C 68F, and power off time 1 second. *2. Power one-shot 1 s range: +2% and 10 ms *3. When using with a transmission wave rectification, vibration resistance and shock resistance properties worsen compared to when using a stabilized power supply. Time range setting Type S1DXM-A S1DXM-M Time scale 10M type 30M type 60M type 10H type 10M type 30M type 60M type 10H type X1 X10 X1 X10 Time unit s s s m s s s m m m m h m m m h Min. scale 0.05 0.2 0.5 0.05 0.05 0.2 0.5 0.05 Max. scale 1 3 6 1 1 3 6 1 0.05 to 1s 0.2 to 3s 0.5 to 6s 0.05 to 1m 0.05 to 1s 0.2 to 3s 0.5 to 6s 0.05 to 1m Note: The time setting range is the combination of the time scale (X1 or X10) on the dial and the time unit (s, m, or h). Example: When dial reads 1, time scale is X1 and time units is seconds, then it is 1 second. All Rights Reserved (c) COPYRIGHT Panasonic Electric Works Co., Ltd. Setting range 0.5 to 10s 0.05 to 1m 2 to 30s 0.2 to 3m 5 to 60s 0.5 to 6m 0.5 to 10m 0.05 to 1h 0.5 to 10s 0.05 to 1m 2 to 30s 0.2 to 3m 5 to 60s 0.5 to 6m 0.5 to 10m 0.05 to 1h 0.5 to 10m 2 to 30m 5 to 60m 0.5 to 10h 0.5 to 10m 2 to 30m 5 to 60m 0.5 to 10h Timers 24VAC S1DXM-A/M Operation mode and Time range setting Timers Operation mode Operation mode switch Time range switch ON 1 Power ON-delay s (m) m (h) X1 X10 2 ON 1 The time setting can be switched among 4 ranges each for 4 types for an interval between 0.05 seconds and 10 hours. Power Flicker OFF start 2 Notes: 1. The product is factory shipped with all settings on the OFF side (left). 2. Do not operate the switches with a sharp-edged object such as a knife blade. 3. The power must be turned off when setting the time range or operation mode. Operating the switches with the power on is a cause of breakdown and malfunction. 4. Use a force of under 5 N to operate the DIP switches when setting the time range and operation mode. ON 1 Power Flicker ON start 2 ON 1 Power One-shot 2 Operation mode S1DXM-A multi-range timer Power ON-delay operation * When power is turned on, the output contact operates after the set time. The output contact remains on until the power is turned off. Time chart Power supply Timed-out contact (NO) ON OFF ON T OFF T: Setting time UP (operation) LED (orange) ON (power) LED (green) S1DXM-M multi-range timer Power ON-delay operation Power Flicker OFF start operation [MODE] switch 1: OFF, switch 2: OFF * When power is turned on, the output contact operates after the set time. The output contact remains on until the power is turned off. [MODE] switch 1: OFF, switch 2: ON * When the power is turned on, the output contacts repeatedly operate at the set time. The output contact begins from the off state. Time chart Time chart Power supply Timed-out contact (NO) ON Power supply OFF ON T Timed-out contact (NO) OFF T: Setting time UP (operation) LED ON OFF ON T T OFF ON (power) LED T T t t