General-purpose Relay G2R-@-S (S) CSM_G2R-_-S_(S)_DS_E_1_6 Slim and Space-saving Power Plug-in Relay Reduces wiring work by 60% when combined with the P2RF-@-PU Push-In Plus Socket (according to actual OMRON measurements). Lockable test button models available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped with a coil-disconnection self-diagnostic function (LED type). High switching power (1-pole: 10 A). LR For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Model Number Structure Model Number Legend G2R - -S (S) 1 2 3 1. Number of Poles 1: 1 pole 2: 2 poles 4 5 4. Rated Coil Voltage 5. Mechanical operation indicator and Nameplate (S): Models with mechanical operation indicator and Nameplate 2. Terminals S: Plug-in 3. Classification Blank: General-purpose N: LED indicator D: Diode ND: LED indicator and diode NI: LED indicator with test button NDI: LED indicator and diode with test button Note: Contact your OMRON representative for Relays with gold-plated contacts. Ordering Information Whenyourorder,specifytheratedvoltage. List of Models Classification General-purpose LED indicator LED indicator with test button Coil ratings AC 24, 48, 110, 120, 230, 240 DC 6, 12, 24, 48 Diode LED indicator and diode LED indicator and diode with test button DC 6, 12, 24, 48 Contact form SPDT DPDT G2R-1-S (S) G2R-2-S (S) G2R-1-SN (S) G2R-2-SN (S) G2R-1-SNI (S) G2R-2-SNI (S) G2R-1-SD (S) G2R-2-SD (S) G2R-1-SND (S) G2R-2-SND (S) G2R-1-SNDI (S) G2R-2-SNDI (S) Note: 1. The standard models are compliant with UL/CSA and VDE standards. Also, an EC compliance declaration has been made for combinations with the P2RF-@-E, P2RF-@-S and P2RF-@-PU. The Relays bear the CE Marking. 2. Refer to Connecting Sockets, below, for applicable Socket models. 3. When ordering, add the rated coil voltage and "(S)" to the model number. Rated coil voltages are given in the coil ratings table. Example: G2R-1-S 12 VDC (S) Rated coil voltage 1 G2R-@-S (S) Accessories (Order Separately) Connecting Sockets Track/surface-mounting Socket Applicable Relay model Push-In Plus Terminal Blocks No. of poles Back-mounting Socket Screw terminals * Model Models 1 pole G2R-1-S (S) P2RF-05-PU P2RF-05 P2RF-05-E 2 poles G2R-2-S (S) P2RF-08-PU P2RF-08 P2RF-08-E PCB terminals Solder terminals Models Model P2R-05P P2R-057P P2R-05A P2R-08P P2R-087P P2R-08A * The structure of P2RF-@-E models provides finger protection. Round terminals cannot be used. Use forked crimp terminals. Accessories for Push-In Plus Terminal Block Sockets (P2RF-@-PU) Short Bars Pitch No. of poles Red (R) Blue (S) Yellow (Y) 4 20 15.5 mm Minimum order (quantity) PYDN-7.75-020@ 3 7.75 mm Model * Colors 2 8 PYDN-7.75-030@ PYDN-7.75-040@ 10 PYDN-7.75-200@ PYDN-15.5-080@ Note: Use the Short Bars for crossover wiring within one Socket or between Sockets. * Replace the box (@) in the model number with the code for the covering color. Labels Model Minimum order (sheet) (quantity per sheet) XW5Z-P4.0LB1 5 1 sheet (60 pieces) Mounting Tracks Applicable Socket Description Model Minimum order (quantity) 50 cm (l) x 7.3 mm (t): PFP-50N Mounting track Track-connecting Socket 1 m (l) x 7.3 mm (t): PFP-100N 1 m (l) x 16 mm (t): PFP-100N2 End plate *1 PFP-M Spacer PFP-S Back-connecting Socket Mounting plate *2 P2R-P --- 10 1 *1. When mounting DIN rail, please use End Plate (PFP-M). *2. Used to mount several P2R-05A and P2R-08A Connecting Sockets side by side. 2 G2R-@-S (S) Specifications Coil Ratings Rated current* Rated voltage 50 Hz AC 60 Hz Armature OFF 43.5 mA 37.4 mA 253 0.81 48 V 21.8 mA 18.8 mA 1,040 3.12 6.17 110 V 9.5 mA 8.2 mA 5,566 13.33 26.83 120 V 8.6 mA 7.5 mA 7,286 16.13 32.46 230 V 4.4 mA 3.8 mA 27,172 72.68 143.90 240 V 4.2 mA 3.7 mA 27,800 90.58 182.34 Rated current* Coil resistance Must release voltage Max. voltage % of rated voltage Power consumption (approx.) 1.55 Coil inductance (H) (ref. value) Armature OFF Must operate voltage Armature ON 24 V Rated voltage DC Coil resistance Coil inductance (H) (ref. value) 80% max. 30% max. Must operate voltage Must release voltage Armature ON 6V 87.0 mA 69 0.25 12 V 43.2 mA 278 0.98 2.35 24 V 21.6 mA 1,113 3.60 8.25 48 V 11.4 mA 4,220 15.2 29.82 110% Max. voltage % of rated voltage 0.9 VA at 60 Hz Power consumption (approx.) 0.48 70% max. 15% min. 110% 0.53 W Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C with tolerances of +15%/-20% for the AC rated current and 10% for the DC coil resistance. 2. The AC coil resistance and inductance values are reference values only (at 60 Hz). 3. Operating characteristics were measured at a coil temperature of 23C. 4. The maximum voltage is the maximum possible value of the voltage that can be applied to the relay coil. It is not the maximum voltage that can be applied continuously. Contact Ratings Number of poles 1 pole Load Resistive load (cos = 1) Inductive load (cos = 0.4; L/R = 7 ms) Resistive load (cos = 1) 2 poles Inductive load (cos = 0.4; L/R = 7 ms) Rated load 10 A at 250 VAC; 10 A at 30 VDC 7.5 A at 250 VAC; 5 A at 30 VDC 5 A at 250 VAC; 5 A at 30 VDC 2 A at 250 VAC; 3 A at 30 VDC Rated carry current 10 A 5A Max. switching voltage 440 VAC, 125 VDC 380 VAC, 125 VDC Max. switching current 10 A Max. switching power 2,500 VA, 300 W Failure rate (reference value) * 100 mA at 5 VDC 5A 1,875 VA, 150 W 1,250 VA, 150 W 500 VA, 90 W 10 mA at 5 VDC Note: P level: 60 = 0.1 x 10-6/operation * This value was measured at a switching frequency of 120 operations per minute. 3 G2R-@-S (S) Characteristics Item 1 pole 2 poles Contact configration SPDT Contact structure Single Contact resistance 100 m max. Operate (set) time 15 ms max. Release (reset) time AC: 10 ms max.; DC: 5 ms max. (w/built-in diode: 20 ms max.) Max. operating frequency Mechanical: Electrical: Insulation resistance 1,000 M min. (at 500 VDC) Dielectric strength * 5,000 VAC, 50/60 Hz for 1 min between coil and 5,000 VAC, 50/60 Hz for 1 min between coil and contacts; contacts; 3,000 VAC, 50/60 Hz for 1 min between contacts of different polarity 1,000 VAC, 50/60 Hz for 1 min between contacts of 1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity same polarity Vibration resistance Destruction: Malfunction: 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Shock resistance Destruction: Malfunction: 1,000 m/s2 200 m/s2 when energized; 100 m/s2 when not energized Mechanical: AC: 15 ms max.; DC: 10 ms max. (w/built-in diode: 20 ms max.) 18,000 operations/hr 1,800 operations/hr (under rated load) Electrical: AC coil: 10,000,000 operations min.; DC coil: 20,000,000 operations min. (at 18,000 operations/hr) 100,000 operations min. (at 1,800 operations/hr under rated load) Ambient temperature Operating: -40C to 70C (with no icing or condensation) Ambient humidity Operating: 5% to 85% Weight Approx. 20 g Endurance Note: Values in the above table are the initial values. * These values are relay only. Prease refer to the "Products Related to Common Sockets and DIN Tracks Data Sheet" for connecting sockets. Approved Standards IEC/VDE (Certificate No. 40015012 EN 61810-1) UL 508 (File No. E41643) Model Contact Coil ratings form Contact ratings Operations G2R-1-S (S) SPDT 10 A, 30 VDC (resistive) 100 x 103 10 A, 250 VAC (general use) G2R-2-S (S) DPDT 25 x 103 5 to 110 VDC TV-3 (NO contact only) 6 to 240 VAC 5 A, 30 VDC (resistive) 100 x 103 5 A, 250 VAC (general use) TV-3 (NO contact only) 25 x 103 CSA 22.2 No.0, No.14 (File No. LR31928) Model Contact Coil ratings form Contact form Operations G2R-1-S (S) SPDT 10 A, 30 VDC (resistive) 100 x 103 10 A, 250 VAC (general use) G2R-2-S (S) DPDT 25 x 103 5 to 110 VDC TV-3 (NO contact only) 6 to 240 VAC 5 A, 30 VDC (resistive) 100 x 103 5 A, 250 VAC (general use) TV-3 (NO contact only) Contact ratings Operations 1 pole 6, 12, 24, 48 VDC 24, 110, 120, 230, 240 VAC 5 A, 440 VAC (cos = 1.0) 10 A, 250 VAC (cos = 1.0) 10 A, 30 VDC (0 ms) 100 x 103 2 poles 6, 12, 24, 48 VDC 24, 110, 120, 230, 240 VAC 5 A, 250 VAC (cos =1.0) 5 A, 30 VDC (0 ms) 100 x 103 LR Number of poles Contact ratings Coil ratings Coil ratings Contact ratings Operations 1 pole 5 to 110 VDC 6 to 240 VDC 10 A, 250 VAC (general use) 7.5 A, 250 VAC (PF0.4) 10 A, 30 VDC (resistive) 5A, 30VDC (L/R=7ms) 100 x 103 2 poles 5 to 110 VDC 6 to 240 VDC 5 A, 250 VAC (general use) 2 A, 250 VAC (PF0.4) 5 A, 30 VDC (resistive) 3A, 30VDC (L/R=7ms) 100 x 103 25 x 103 4 G2R-@-S (S) Engineering Data Maximum Switching Power G2R-2-S (S) G2R-1-S (S) 100 Switching current (A) AC inductive load (cos = 0.4) AC resistive load 10 DC resistive load DC inductive load (L/R = 7 ms) 1 0.1 1 10 100 Switching current (A) 100 AC resistive load DC resistive load 1 0.1 1000 AC inductive load (cos = 0.4) 10 DC inductive load (L/R = 7 ms) 1 Switching voltage (V) 10 100 1000 Switching voltage (V) Endurance G2R-2-S (S) 10,000 5,000 1,000 250-VAC/30-VDC resistive load 500 100 250-VAC inductive load (cos = 0.4) 30-VDC inductive load (L/R = 7ms) 50 Switching current (A) Endurance (x103 operations) Endurance (x103 operations) G2R-1-S (S) 5,000 1,000 500 30-VDC inductive load (L/R = 7ms) 250-VAC/30-VDC resistive load 100 250-VAC 50 inductive load (cos = 0.4) Switching current (A) Maximum voltage (%) Ambient Temperature vs Maximum Coil Voltage DC coil AC coil Ambient temperature (C) 5 G2R-@-S (S) Dimensions (Unit: mm) Note: All units are in millimeters unless otherwise indicated. SPDT Relays G2R-1-S (S), G2R-1-SN (S), G2R-1-SNI (S) G2R-1-SD (S), G2R-1-SND (S), G2R-1-SNDI (S) Terminal Arrangement/Internal Connections (Bottom View) G2R-1-SD (S) (DC) G2R-1-S (S) 29 max. 1 13 max. 1 2 20 35.5 max. 5 4 3 G2R-1-SN (S), G2R-1-SNI (S) (AC) 4.75 2 5 3 4 4 2 5 3 7.5 0.5 1 5 1 24V 3 4 G2R-1-SN (S), G2R-1-SNI (S) (DC) 1 DC 2 5 G2R-1-SND (S), G2R-1-SNDI (S) (DC) 5.2 5.2 17.5 1 2 5 3 4 DPDT Relays G2R-2-S (S), G2R-2-SN (S), G2R-2-SNI (S) G2R-2-SD (S), G2R-2-SND (S), G2R-2-SNDI (S) Terminal Arrangement/Internal Connections (Bottom View) G2R-2-S (S) 1 2 3 4 8 7 6 5 13 max. 2.5 35.5 max. 1 2 3 4 8 7 6 5 G2R-2-SN (S), G2R-2-SNI (S) (DC) 1 2 3 4 1 2 3 4 8 7 6 5 8 7 6 5 7.4 8.9 2.4 G2R-2-SN (S), G2R-2-SNI (S) (AC) 6.2 20 29 max. 0.5 G2R-2-SD (S) (DC) G2R-2-SND (S), G2R-2-SNDI (S) (DC) 5 5 19.4 1 2 3 4 8 7 6 5 6 G2R-@-S (S) Track/Surface Mounting Sockets P2RF-05-PU 57.5 Terminal Arrangement/ Internal Connection Diagram (Top View) 53.1 A2 30.8 28.1 (4.2) (1) Mounting Hole Dimensions A1 (5) 25.6 Two M3 screw holes or two 3.5-dia. holes 108 90 Releaselever 35.3 12 (2) 14 (3) 27.35 11 (4) (4.2) 3.9 15.5 34.3 43 52.1 P2RF-08-PU Note: Pull out the hooks to mount the Socket with screws. Note: The numbers in parentheses are traditionally used terminal numbers. 25.6 57.5 Terminal Arrangement/ Internal Connection Diagram (Top View) 53.1 30.8 28.1 (4.2) A2 (1) Mounting Hole Dimensions A1 (8) 25.6 Two M3 screw holes or two 3.5-dia. holes 90 Releaselever 35.3 108 12 27.35 (4.2) 3.9 15.5 25.6 34.3 Application Pitch PYDN-7.75-@@ (7.75 mm) 3.90 L 12 For Coil terminals 1.57 PYDN-15.5-080@ (15.5 mm) 3.90 115.85 2.25 7.75 mm 18.5 2.25 12 For Contact terminals (common) 15.5 mm (7) 14 24 (4) (5) 11 21 (3) (6) Note: The numbers in parentheses are traditionally used terminal numbers. 43 52.1 Accessories for P2RF-@-PU Short Bars 22 (2) No. of poles L (Length) 2 15.1 3 22.85 4 30.6 20 154.6 8 115.85 Colors Note: Pull out the hooks to mount the Socket with screws. Model * Maximum carry current PYDN-7.75-020@ PYDN-7.75-030@ Red (R) Blue (S) Yellow (Y) PYDN-7.75-040@ 20 A PYDN-7.75-200@ PYDN-15.5-080@ * Replace the box (@) in the model number with the code for the covering color. Note: 1. Use the Short Bars for crossover wiring within one Socket or between Sockets. 2. When using short bar to coil terminals of PYF-@@-PU, make sure to use PYDN-31.0080@ (31 mm). When using short bar to coil terminals of P2RF-@@-PU, make sure to use PYDN-15.5080@ (15.5 mm). 18.5 1.57 7 G2R-@-S (S) P2RF-05-E 70.2 Five, M3.57 2 48 max. Terminal Arrangement (Top View) 4 (12) 39.5 3 35.5 85.5 max. Mounting Holes (for Surface Mounting) 3.2-dia. hole (11) 2 (14) 39.50.1 3.5-dia. hole M3 or 3.5-dia. hole 5 (A1) (A2) 4 1 11.5 61 max. 16.0 max. Note: Pin numbers in parentheses apply to DIN standard. P2RF-08-E 6 +0.2 -0.1 2 Terminal Arrangement (Top View) 2 1.5 Eight, M38 48.0 max. Mounting Holes (for Surface Mounting) 3 39.5 (21) (22) (24) 6 3 7 5 2 4 (11) (12) (14) 3.2-dia. hole 35.5 39.50.1 85.5 max. 3.5-dia. hole 8 (A1) (A2) 4 61.0 max. 1 M3 or 3.5-dia. hole 11.5 16.0 max. P2RF-05 2 7 Terminal Arrangement (Top View) Five, M3.5 x 8 4-dia. holes Mounting Holes (for Surface Mounting) 4.2-dia. hole 35.5 71.5 max. 300.05 4 19.5 30 max. 19.5 max. M3 or 3.2-dia. hole 54 max. P2RF-08 2 7 Eight, M3.5 x 8 4-dia. holes Terminal Arrangement (Top View) Mounting Holes (for Surface Mounting) 4.2-dia. hole 35.5 71.5 max. 300.05 4 19.5 max. 19.5 30 max. 54 max. M3 or 3.2-dia. hole 8 G2R-@-S (S) Mounting Height of Relay with Track/Surface Mounting Sockets P2RF-05-PU P2RF-08-PU G2R-@-S (S) Relay G2R-@-S (S) Relay P2RF-05PU Socket P2RF-08PU Socket 63.6 63.6 28.1 28.1 (3.9) (3.9) P2RF-@ P2RF-@-E G2R-@-S (S) Relay G2R-@-S (S) Relay P2RF-@-E Socket P2RF-@ Socket 67.0 70.5 66.5 62.0 Back-connecting Sockets P2R-05P (1-pole) 4 1 Terminal Arrangement (Bottom View) 14.5 max. 7 Mounting Holes Tolerance: 0.1 4 6 4.5 6 35.5 max. 15 Five, 1.6-dia. holes 4.5 1.2 4 15 3.5 4 1.5 (5) 4 7 7 36.5 max. P2R-08P (2-pole) 4 0.3 14.5 max. 7 Terminal Arrangement (Bottom View) Mounting Holes 7.5 Eight, 1.3-dia. holes 5 5 35.5 max. 20 1 5 5 20 2.8 1.5 (4.3) 7.5 Terminal plate thickness: 0.3 36.5 max. 9 G2R-@-S (S) 4.5 P2R-05A (1-pole) 7.5 14.5 max. 1.2 0.3 Terminal Arrangement (Bottom View) 6.7 3.8 35.5 max. 5 16.7 Panel Cutout Five, 3 x 1.8-dia. holes 13.60.1 6 36.5 max. Terminal plate thickness: 0.3 30.50.2 6.5 7.5 P2R-08A (2-pole) 14.5 max. 1.2 0.3 5 5 35.5 max. Recommended thickness of the panel is 1.6 to 2.0 mm 20 2.6 2.8 1.5 Eight, 3 x 1.2-dia. holes 7.5 Terminal plate thickness: 0.3 P2R-057P (1-pole) 0.7 14 max. 8.7 36.5 max. 1 Terminal Arrangement (Bottom View) 16.4 10.4 3.5 1 Mounting Holes 40.1 6 4.5 15 37 max.29.6 1 8.7 Five, 1.6-dia. holes 60.1 4 8.75 4.50.1 150.1 40.1 5 7.4 70.1 41 max. P2R-087P (2-pole) 14 max. 7.5 1 Terminal Arrangement (Bottom View) 16.4 10.4 3.5 0.3 7.5 5 5 37 max. 29.1 20 1 Eight, 1.3-dia. holes 5 5 8.1 8.9 Mounting Holes 20 7.4 (8.1) 41 max. Mounting Height of Relay with Back-connecting Sockets P2R-@P P2R-@A P2R-@7P G2R-@-S (S) Relay G2R-@-S (S) Relay 44.5 P2R-@P Socket 38.0 47.5 P2R-@A Socket G2R-@-S (S) Relay P2R-@7P Socket 10 G2R-@-S (S) Mounting Tracks PFP-100N, PFP-50N PFP-100N2 16 7.30.15 4.5 4.5 15 25 25 25 25 10 15 (5) 10 1,000 (500) 350.3 27 270.15 350.3 15 1 25 25 15 25 25 10 10 24 29.2 1 1.5 1,000 It is recommended to use a panel 1.6 to 2.0 mm thick. End Plate Spacer 10 6.2 PFP-M PFP-S 16 12 5 1.8 1 50 1.8 11.5 10 M4 x 8 pan head screw 35.5 35.3 34.8 44.3 1.3 4.8 16.5 Mounting Plate P2R-P 90 R2.25 10-Ellipsehole 4.5 13.6 3.4 49 420.1 30.5 180.15 180.15 180.15 180.15 Squarehole 90.1 720.2 90.1 t=1.6 mm Safety Precautions Be sure to read the Common Precautions for All Relay in the website at the following URL: http://www.ia.omron.com/. Refer to Products Related to Common Sockets and DIN Tracks for precautions on the applicable Sockets. Refer to PYF-@@-PU/P2RF-@@-PU for precautions on Push-In Plus Terminal Block Sockets. Warning Indications CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or in property damage. Cation * Do not use the test button for any purpose other than testing. Be sure not to touch the test button accidentally as this will turn the contacts ON. Before using the test button, confirm that circuits, the load, and any other connected item will operate safely. * Check that the test button is released before turning ON relay circuits. * If the test button is pulled out too forcefully, it may bypass the momentary testing position and go straight into the locked position. * Use an insulated tool when you operate the test button. 11 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron's exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron's sole obligation hereunder shall be, at Omron's election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron's analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer's application or use of the Product. At Buyer's request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer's application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user's programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron's test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron's Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron's representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2019.7 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2019 All Right Reserved.