ATCA-F125 Data Sheet
Telecom Clock Characteristics
(if equipped)
TELECOM CLOCK CHIP
Semtech Topsync ACS9510
SUPPORTED CONFIGURATIONS
Input: BITS/SSU / Output: Backplane CLK 1/2
Input: Backplane CLK 3 / Output: Backplane
CLK 1/2
Input: Backplane CLK 3 / Output: BITS/SSU
TIMING REFERENCE
Traditional signal-based reference as dened by Telcordia
GR-1244-CORE [5]
PERFORMANCE
Stratum 3
SRstackware® Software
Linux-based L2 and L3 switch management software providing
a rich selection of features and protocols, e.g.
• STP/RSTP/MSTP
• VLAN, VLAN stacking (Q-in-Q)
• LACP
• Flow Control
• Class of Service
• GARP/GMRP/GVRP
• SNMPv2, SNMPv3
• ACL
• IGMP v1/v2/v3, IGMP snooping/proxy
• RIPv2, RIPng
• OSPFv2
• VRRP
Multi-shelf capable Service Availability Forum™ Hardware
Platform Interface (HPI) support
Regulatory Compliance
Designed to comply with NEBS
Telcordia GR-63-CORE, NEBS Physical Protection, Level 3
Telcordia GR-1089-CORE, Electromagnetic Compatibility and Electrical Safety — Generic Criteria for Network
Telecommunications Equipment. Level 3, Equipment Type 2
Designed to comply with ETSI
ETSI Storage, ETS 300 019-2-1, Class 1.2 equipment, Weatherprotected, not Temperature Controlled Storage
Locations
ETSI Transportation, ETS 300 019-1-2, Class 2.3 equipment, Public Transportation
ETSI Operation, ETS 300 019-1-3, Class 3.1(E) equipment, Partly Temperature Controlled Locations
ETSI EN 300-132-2 Environmental Engineering (EE); Power supply interface at the input to telecommunications
equipment; Part 2: Operated by direct current (dc)
ETS-300-753, Equipment Engineering (EE); Acoustic noise emitted by telecommunications equipment
EMC
ETSI EN 300 386 Electromagnetic compatibility and Radio spectrum Matters (ERM); telecommunication network
equipment; ElectroMagnetic Compatibility (EMC) requirements, Telecommunication equipment room (attended)
FCC 47 CFR Part 15 Subpart B (US), Class A
ECISPR 22, Limits and Methods of Measurement of Radio Disturbance Characteristics of Information Technology
Equipment
AS/NZS CISPR 22 (Australia/New Zealand), Limits and Methods of Measurement of Radio Disturbance Characteristics
of Information Technology Equipment
VCCI Class A (Japan), Voluntary Control Council for Interference by Information Technology Equipment
Industry Canada ICES-003 Class A
Safety
Compliance to UL/CSA 60950-1, EN 60950-1 and IEC 60950-1 CB Scheme. Marked with U.S. NRTL, Canadian Safety
and CE Mark.
RoHS compliance
DIRECTIVE 2002/95/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL on the restriction of the use of
certain hazardous substances in electrical and electronic equipment (RoHS)
DIRECTIVE 2002/96/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL on waste electrical and electronic
equipment
Directive 2011/65/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 8 June 2011 on the restriction of
the use of certain hazardous substances in electrical and electronic equipment.
CE Conformity Directive 2004/108/EC, Directive 2006/95/EC