Alt er a Cor pora t ion 1
FLEX 8000
Programmable Logic
Device Family
Jan uary 2003, ve r. 11.1 Data Sheet
DS-F8000-11.1
FLEX 8000
3
1
Features... Low-cost, high-density, register-rich CMOS programmable logic
device (PLD) family (see Table 1)
2,500 to 16,000 usable gates
282 to 1,500 registers
System-level features
In-circuit reconfigurability (ICR) via external configuration
devices or intelligent controller
Fully compliant with the peripheral component interconnect
Special Interest Group (PCI SIG) PCI Local Bus Specification,
Revision 2.2 for 5.0-V operation
Built-in Joint Test Action Group (JTAG) boundary-scan test (BST)
circuitry compliant with IEEE Std. 1149.1-1990 on selected devices
–MultiVolt
TM I/O interface enabling device core to run at 5.0 V,
while I/O pins are compatible with 5.0-V and 3.3-V logic levels
Low power consumption (typical specification is 0.5 mA or less in
standby mode)
Flexible interconnect
–FastTrack
® Interconnect continuous routing structure for fast,
predictable interconnect delays
Dedicated carry chain that implements arithmetic functions such
as fast adders, counters, and comparators (automatically used by
software tools and megafunctions)
Dedicated cascade chain that implements high-speed, high-fan-in
logic functions (automatically used by software tools and
megafunctions)
Tri-state emulation that implements internal tri-state nets
Powerful I/O pins
Programmable output slew-rate control reduces switching noise
Table 1. FLEX 8000 Device Features
Feature EPF8282A
EPF8282AV
EPF8452A EPF8636A EPF8820A EPF81188A EPF81500A
Usable gates 2,500 4,000 6,000 8,000 12,000 16,000
Flipflops 282 452 636 820 1,188 1,500
Logic array blocks (LABs) 26 42 63 84 126 162
Logic elements (LEs) 208 336 504 672 1,008 1,296
Maximum us er I /O pins 78 120 136 152 184 208
2Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
...and More
Features
Peripheral register for fast setup and clock-to-output delay
Fabricated on an advanced SRAM process
Available in a variety of packages with 84 to 304 pins (see Table 2)
Software design support and automatic place-and-route provided by
the Altera® MAX+PLUS® II development system for Windows-based
PCs, as well as Sun SPARCstation, HP 9000 Series 700/800, and IBM
RISC System/6000 workstations
Additional design entry and simulation support provided by EDIF
2 0 0 and 3 0 0 netlist files, library of parameterized modules (LPM),
Verilog HDL, VHDL, and other interfaces to popular EDA tools from
manufacturers such as Cadence, Exemplar Logic, Mentor Graphics,
OrCAD, Synopsys, Synplicity, and Veribest
Note:
(1) FLEX 8000 device package types include plastic J-lead chip carrier (PLCC), thin quad flat pack (TQFP), plastic quad
flat pack (PQFP), power quad flat pack (RQFP), ball-grid array (BGA), and pin-grid array (PGA) packages.
General
Description
Altera’s Flexible Logic Element MatriX (FLEX®) family combines the
benefits of both erasable programmable logic devices (EPLDs) and field-
programmable gate arrays (FPGAs). The FLEX 8000 device family is ideal
for a variety of applications because it combines the fine-grained
architecture and high register count characteristics of FPGAs with the
high speed and predictable interconnect delays of EPLDs. Logic is
implemented in LEs that include compact 4-input look-up tables (LUTs)
and programmable registers. High performance is provided by a fast,
continuous network of routing resources.
JTAG BST circuitry Yes No Yes Yes No Yes
Table 2. FLEX 8000 Package Options & I/O Pin Count Note (1)
Device 84-
Pin
PLCC
100-
Pin
TQFP
144-
Pin
TQFP
160-
Pin
PQFP
160-
Pin
PGA
192-
Pin
PGA
208-
Pin
PQFP
225-
Pin
BGA
232-
Pin
PGA
240-
Pin
PQFP
280-
Pin
PGA
304-
Pin
RQFP
EPF8282A 68 78
EPF8282AV 78
EPF8452A 68 68 120 120
EPF8636A 68 118 136 136
EPF8820A 112 120 152 152 152
EPF81188A 148 184 184
EPF81500A 181 208 208
Altera Corporation 3
FLEX 8000 Pr o grammabl e Log i c Dev ic e Fam ily D ata Sh eet
FLEX 8000
3
FLEX 8000 devices provide a large number of storage elements for
applications such as digital signal processing (DSP), wide-data-path
manipulation, and data transformation. These devices are an excellent
choice for bus interfaces, TTL integration, coprocessor functions, and
high-speed controllers. The high-pin-count packages can integrate
multiple 32-bit buses into a single device. Table 3 shows FLEX 8000
performance and LE requirements for typical applications.
All FLEX 8000 device packages provide four dedicated inputs for
synchronous control signals with large fan-outs. Each I/O pin has an
associated register on the periphery of the device. As outputs, these
registers provide fast clock-to-output times; as inputs, they offer quick
setup times.
The logic and interconnections in the FLEX 8000 architecture are
configured with CMOS SRAM elements. FLEX 8000 devices are
configured at system power-up with data stored in an industry-standard
parallel EPROM or an Altera serial configuration devices, or with data
provided by a system controller. Altera offers the EPC1, EPC1213,
EPC1064, and EPC1441 configuration devices, which configure
FLEX 8000 devices via a serial data stream. Configuration data can also be
stored in an industry-standard 32 K × 8 bit or larger configuration device,
or downloaded from system RAM. After a FLEX 8000 device has been
configured, it can be reconfigured in-circuit by resetting the device and
loading new data. Because reconfiguration requires less than 100 ms, real-
time changes can be made during system operation. For information on
how to configure FLEX 8000 devices, go to the following documents:
Configuration Devices for APEX & FLEX Devices Data Sheet
BitBlaster Serial Download Cable Data Sheet
ByteBlasterMV Parallel Port Download Cable Data Sheet
Application Note 33 (Configuring FLEX 8000 Devices)
Application Note 38 (Configuring Multiple FLEX 8000 Devices)
Table 3. FLEX 8000 Performance
Application LEs Used Speed Grade Units
A-2 A-3 A-4
16-bit loadable count er 16 125 95 83 MHz
16-bit up/ dow n c ount er 16 125 95 83 MHz
24-bit ac cumulator 24 87 67 58 MHz
16-bit address decode 44.2 4.9 6.3 ns
16-t o-1 m ult iplex er 10 6.6 7.9 9.5 ns
4Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
FLEX 8000 devices contain an optimized microprocessor interface that
permits the microprocessor to configure FLEX 8000 devices serially, in
parallel, synchronously, or asynchronously. The interface also enables the
microprocessor to treat a FLEX 8000 device as memory and configure the
device by writing to a virtual memory location, making it very easy for the
designer to create configuration software.
The FLEX 8000 family is supported by Altera’s MAX+PLUS II
development system, a single, integrated package that offers schematic,
text—including the Altera Hardware Description Language (AHDL),
VHDL, and Verilog HDL—and waveform design entry, compilation and
logic synthesis, simulation and timing analysis, and device programming.
The MAX+PLUS II software provides EDIF 2 0 0 and 3 0 0, library of
parameterized modules (LPM), VHDL, Verilog HDL, and other interfaces
for additional design entry and simulation support from other industry-
standard PC- and UNIX workstation-based EDA tools. The
MAX+PLUS II software runs on Windows-based PCs and Sun
SPARCstation, HP 9000 Series 700/800, and IBM RISC System/6000
workstations.
The MAX+PLUS II software interfaces easily with common gate array
EDA tools for synthesis and simulation. For example, the MAX+PLUS II
software can generate Verilog HDL files for simulation with tools such as
Cadence Verilog-XL. Additionally, the MAX+PLUS II software contains
EDA libraries that use device-specific features such as carry chains, which
are used for fast counter and arithmetic functions. For instance, the
Synopsys Design Compiler library supplied with the MAX+PLUS II
development system includes DesignWare functions that are optimized
for the FLEX 8000 architecture.
fFor more information on the MAX+PLUS II software, go to the
MAX+PLUS II Programmable Logic Development System & Software Data
Sheet.
Functional
Description
The FLEX 8000 architecture incorporates a large matrix of compact
building blocks called logic elements (LEs). Each LE contains a 4-input
LUT that provides combinatorial logic capability and a programmable
register that offers sequential logic capability. The fine-grained structure
of the LE provides highly efficient logic implementation.
Eight LEs are grouped together to form a logic array block (LAB). Each
FLEX 8000 LAB is an independent structure with common inputs,
interconnections, and control signals. The LAB architecture provides a
coarse-grained structure for high device performance and easy routing.
Altera Corporation 5
FLEX 8000 Pr o grammabl e Log i c Dev ic e Fam ily D ata Sh eet
FLEX 8000
3
Figure 1 shows a block diagram of the FLEX 8000 architecture. Each group
of eight LEs is combined into an LAB; LABs are arranged into rows and
columns. The I/O pins are supported by I/O elements (IOEs) located at
the ends of rows and columns. Each IOE contains a bidirectional I/O
buffer and a flipflop that can be used as either an input or output register.
Figure 1. FLEX 8000 Device Block Diagram
Signal interconnections within FLEX 8000 devices and between device
pins are provided by the FastTrack Interconnect, a series of fast,
continuous channels that run the entire length and width of the device.
IOEs are located at the end of each row (horizontal) and column (vertical)
FastTrack Interconnect path.
IOEIOE IOEIOE
IOE
IOE
IOE
IOE
IOE
IOE
IOE
IOE
IOEIOE IOEIOE
I/O Element
(IOE)
Logic Array
Block (LAB)
Logic
Element (LE)
FastTrack
Interconnect
6Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Logic Array Block
A logic array block (LAB) consists of eight LEs, their associated carry and
cascade chains, LAB control signals, and the LAB local interconnect. The
LAB provides the coarse-grained structure of the FLEX 8000 architecture.
This structure enables FLEX 8000 devices to provide efficient routing,
high device utilization, and high performance. Figure 2 shows a block
diagram of the FLEX 8000 LAB.
Figure 2. FLEX 8000 Logic Array Block
Carry-In and
Cascade-In
from LAB
on Left
Dedicated
Inputs
LE1
4
LE8
4
4
LE2
4
4
4
2
2
LE3
4
LE4
4
LE5
4
LE6
4
LE7
4
Column
Interconnect
Row Interconnect
8
24
LAB Local
Interconnect
(32 channels)
8
Column-to-Row
Interconnect
Carry-Out and
Cascade-Out
to LAB on Right
8
16
LAB Control
Signals
See Figure 8
for details.
Altera Corporation 7
FLEX 8000 Pr o grammabl e Log i c Dev ic e Fam ily D ata Sh eet
FLEX 8000
3
Each LAB provides four control signals that can be used in all eight LEs.
Two of these signals can be used as clocks, and the other two for
clear/preset control. The LAB control signals can be driven directly from
a dedicated input pin, an I/O pin, or any internal signal via the LAB local
interconnect. The dedicated inputs are typically used for global clock,
clear, or preset signals because they provide synchronous control with
very low skew across the device. FLEX 8000 devices support up to four
individual global clock, clear, or preset control signals. If logic is required
on a control signal, it can be generated in one or more LEs in any LAB and
driven into the local interconnect of the target LAB.
Logic Element
The logic element (LE) is the smallest unit of logic in the FLEX 8000
architecture, with a compact size that provides efficient logic utilization.
Each LE contains a 4-input LUT, a programmable flipflop, a carry chain,
and cascade chain. Figure 3 shows a block diagram of an LE.
Figure 3. FLEX 8000 LE
The LUT is a function generator that can quickly compute any function of
four variables. The programmable flipflop in the LE can be configured for
D, T, JK, or SR operation. The clock, clear, and preset control signals on the
flipflop can be driven by dedicated input pins, general-purpose I/O pins,
or any internal logic. For purely combinatorial functions, the flipflop is
bypassed and the output of the LUT goes directly to the output of the LE.
LABCTRL3
LABCTRL4
DATA1
DATA2
DATA3
DATA4
LABCTRL1
LABCTRL2
Carry-In
LE-Out
Clock
Select
Carry-Out
PRN
CLRN
DQ
DFF
Look-Up
Table
(LUT)
Clear/
Preset
Logic
Carry
Chain Cascade
Chain
Cascade-In
Cascade-Out
8Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
The FLEX 8000 architecture provides two dedicated high-speed data
paths—carry chains and cascade chains—that connect adjacent LEs
without using local interconnect paths. The carry chain supports high-
speed counters and adders; the cascade chain implements wide-input
functions with minimum delay. Carry and cascade chains connect all LEs
in an LAB and all LABs in the same row. Heavy use of carry and cascade
chains can reduce routing flexibility. Therefore, the use of carry and
cascade chains should be limited to speed-critical portions of a design.
Carry Chain
The carry chain provides a very fast (less than 1 ns) carry-forward
function between LEs. The carry-in signal from a lower-order bit moves
forward into the higher-order bit via the carry chain, and feeds into both
the LUT and the next portion of the carry chain. This feature allows the
FLEX 8000 architecture to implement high-speed counters and adders of
arbitrary width. The MAX+PLUS II Compiler can create carry chains
automatically during design processing; designers can also insert carry
chain logic manually during design entry.
Figure 4 shows how an n-bit full adder can be implemented in n+ 1 LEs
with the carry chain. One portion of the LUT generates the sum of two bits
using the input signals and the carry-in signal; the sum is routed to the
output of the LE. The register is typically bypassed for simple adders, but
can be used for an accumulator function. Another portion of the LUT and
the carry chain logic generate the carry-out signal, which is routed directly
to the carry-in signal of the next-higher-order bit. The final carry-out
signal is routed to another LE, where it can be used as a general-purpose
signal. In addition to mathematical functions, carry chain logic supports
very fast counters and comparators.
Altera Corporation 9
FLEX 8000 Pr o grammabl e Log i c Dev ic e Fam ily D ata Sh eet
FLEX 8000
3
Figure 4. FLEX 8000 Carry Chain Operation
Cascade Chain
With the cascade chain, the FLEX 8000 architecture can implement
functions that have a very wide fan-in. Adjacent LUTs can be used to
compute portions of the function in parallel; the cascade chain serially
connects the intermediate values. The cascade chain can use a logical AND
or logical OR (via De Morgan’s inversion) to connect the outputs of
adjacent LEs. Each additional LE provides four more inputs to the
effective width of a function, with a delay as low as 0.6 ns per LE.
LU
a1
b1
Carry
s1
LE1
Register
a2
b2
Carry Chain
s2
LE2
Register
Carry Chain
s
n
LE
n
Register
a
n
b
n
Carry Chain
Carry-Out
LE
n
+ 1
Register
Carry-In
LUT
LUT
LUT
10 Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
The MAX+PLUS II Compiler can create cascade chains automatically
during design processing; designers can also insert cascade chain logic
manually during design entry. Cascade chains longer than eight LEs are
automatically implemented by linking LABs together. The last LE of an
LAB cascades to the first LE of the next LAB.
Figure 5 shows how the cascade function can connect adjacent LEs to
form functions with a wide fan-in. These examples show functions of 4n
variables implemented with n LEs. For a device with an A-2 speed grade,
the LE delay is 2.4 ns; the cascade chain delay is 0.6 ns. With the cascade
chain, 4.2 ns is needed to decode a 16-bit address.
Figure 5. FLEX 8000 Cascade Chain Operation
LE Operating Modes
The FLEX 8000 LE can operate in one of four modes, each of which uses
LE resources differently. See Figure 6. In each mode, seven of the ten
available inputs to the LE—the four data inputs from the LAB local
interconnect, the feedback from the programmable register, and the
carry-in and cascade-in from the previous LE—are directed to different
destinations to implement the desired logic function. The three remaining
inputs to the LE provide clock, clear, and preset control for the register.
The MAX+PLUS II software automatically chooses the appropriate mode
for each application. Design performance can also be enhanced by
designing for the operating mode that supports the desired application.
d[3..0]
LE1
LUT
d[7..4]
LE2
LUT
d[(4
n-
1)..4(
n-
1)]
LE
n
LUT
d[3..0] LUT
d[7..4] LUT
d[(4
n-
1)..4(
n-
1)] LUT
LE1
LE2
LE
n
AND Cascade Chain OR Cascade Chain
Altera Corporation 11
FLEX 8000 Pr o grammabl e Log i c Dev ic e Fam ily D ata Sh eet
FLEX 8000
3
Figure 6. FLEX 8000 LE Operating Modes
PRN
CLRN
DQ
4-Input
LUT
Carry-In
Cascade-Out
LE-Out
Cascade-In
data1
data2
data3
data4
PRN
CLRN
DQ
Cascade-Out
LE-Out
Cascade-In
3-Input
LUT
Carry-In
3-Input
LUT
Carry-Out
data1
data2
PRN
CLRN
DQ
3-Input
LUT
Carry-In Cascade-In
LE-Out
3-Input
LUT
Carry-Out
1
0
Cascade-Out
(ena)
(nclr)
(data)
(nload)
data1
data2
data3
data4
PRN
CLRN
DQ
3-Input
LUT
Carry-In
LE-Out
3-Input
LUT
Carry-Out
1
0
Cascade-Out
(ena)
(nclr)
(data)
(nload)
data1
data2
data3
data4
Normal Mode
Arithmetic Mode
Up/Down Counter Mode
Clearable Counter Mode
12 Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Normal Mode
The normal mode is suitable for general logic applications and wide
decoding functions that can take advantage of a cascade chain. In normal
mode, four data inputs from the LAB local interconnect and the carry-in
signal are the inputs to a 4-input LUT. Using a configurable SRAM bit, the
MAX+PLUS II Compiler automatically selects the carry-in or the DATA3
signal as an input. The LUT output can be combined with the cascade-in
signal to form a cascade chain through the cascade-out signal. The LE-Out
signal—the data output of the LE—is either the combinatorial output of
the LUT and cascade chain, or the data output (Q)of the programmable
register.
Arithmetic Mode
The arithmetic mode offers two 3-input LUTs that are ideal for
implementing adders, accumulators, and comparators. One LUT
provides a 3-bit function; the other generates a carry bit. As shown in
Figure 6, the first LUT uses the carry-in signal and two data inputs from
the LAB local interconnect to generate a combinatorial or registered
output. For example, in an adder, this output is the sum of three bits: a, b,
and the carry-in. The second LUT uses the same three signals to generate
a carry-out signal, thereby creating a carry chain. The arithmetic mode
also supports a cascade chain.
Up/Down Counter Mode
The up/down counter mode offers counter enable, synchronous
up/down control, and data loading options. These control signals are
generated by the data inputs from the LAB local interconnect, the carry-in
signal, and output feedback from the programmable register. Two 3-input
LUTs are used: one generates the counter data, and the other generates the
fast carry bit. A 2-to-1 multiplexer provides synchronous loading. Data
can also be loaded asynchronously with the clear and preset register
control signals, without using the LUT resources.
Clearable Counter Mode
The clearable counter mode is similar to the up/down counter mode, but
supports a synchronous clear instead of the up/down control; the clear
function is substituted for the cascade-in signal in the up/down counter
mode. Two 3-input LUTs are used: one generates the counter data, and
the other generates the fast carry bit. Synchronous loading is provided by
a 2-to-1 multiplexer, and the output of this multiplexer is ANDed with a
synchronous clear.
Altera Corporation 13
FLEX 8000 Pr o grammabl e Log i c Dev ic e Fam ily D ata Sh eet
FLEX 8000
3
Internal Tri-State Emulation
Internal tri-state emulation provides internal tri-stating without the
limitations of a physical tri-state bus. In a physical tri-state bus, the
tri-state buffers’ output enable signals select the signal that drives the bus.
However, if multiple output enable signals are active, contending signals
can be driven onto the bus. Conversely, if no output enable signals are
active, the bus will float. Internal tri-state emulation resolves contending
tri-state buffers to a low value and floating buses to a high value, thereby
eliminating these problems. The MAX+PLUS II software automatically
implements tri-state bus functionality with a multiplexer.
Clear & Preset Logic Control
Logic for the programmable register’s clear and preset functions is
controlled by the DATA3, LABCTRL1, and LABCTRL2 inputs to the LE. The
clear and preset control structure of the LE is used to asynchronously load
signals into a register. The register can be set up so that LABCTRL1
implements an asynchronous load. The data to be loaded is driven to
DATA3; when LABCTRL1 is asserted, DATA3 is loaded into the register.
During compilation, the MAX+PLUS II Compiler automatically selects
the best control signal implementation. Because the clear and preset
functions are active-low, the Compiler automatically assigns a logic high
to an unused clear or preset.
The clear and preset logic is implemented in one of the following six
asynchronous modes, which are chosen during design entry. LPM
functions that use registers will automatically use the correct
asynchronous mode. See Figure 7.
Clear only
Preset only
Clear and preset
Load with clear
Load with preset
Load without clear or preset
14 Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Figure 7. FLEX 8000 LE Asynchronous Clear & Preset Modes
Asynchronous Load with Preset
NOT
NOT
LABCTRL1
(Asynchronous
Load)
LABCTRL2
(Preset)
DATA3
(Data)
PRN
CLRN
DQ
Asynchronous Load without Clear or Preset
LABCTRL1
(Asynchronous
Load)
DATA3
(Data)
NOT
NOT
PRN
CLRN
DQ
LABCTRL1
(Asynchronous
Load)
Asynchronous Load with Clear
DATA3
(Data)
LABCTRL2
(Clear)
NOT
NOT
PRN
CLRN
DQ
LABCTRL1 or
LABCTRL2
LABCTRL1 or
LABCTRL2
LABCTRL1
LABCTRL2
Asynchronous Clear Asynchronous Preset Asynchronous Clear & Preset
PRN
CLRN
DQ
VCC
PRN
CLRN
DQ
PRN
CLRN
DQ
Altera Corporation 15
FLEX 8000 Pr o grammabl e Log i c Dev ic e Fam ily D ata Sh eet
FLEX 8000
3
Asynchronous Clear
A register is cleared by one of the two LABCTRL signals. When the CLRn
port receives a low signal, the register is set to zero.
Asynchronous Preset
An asynchronous preset is implemented as either an asynchronous load
or an asynchronous clear. If DATA3 is tied to VCC, asserting LABCTRLl
asynchronously loads a 1 into the register. Alternatively, the
MAX+PLUS II software can provide preset control by using the clear and
inverting the input and output of the register. Inversion control is
available for the inputs to both LEs and IOEs. Therefore, if a register is
preset by only one of the two LABCTRL signals, the DATA3 input is not
needed and can be used for one of the LE operating modes.
Asynchronous Clear & Preset
When implementing asynchronous clear and preset, LABCTRL1 controls
the preset and LABCTRL2 controls the clear. The DATA3 input is tied to VCC;
therefore, asserting LABCTRL1 asynchronously loads a 1 into the register,
effectively presetting the register. Asserting LABCTRL2 clears the register.
Asynchronous Load with Clear
When implementing an asynchronous load with the clear, LABCTRL1
implements the asynchronous load of DATA3 by controlling the register
preset and clear. LABCTRL2 implements the clear by controlling the
register clear.
Asynchronous Load with Preset
When implementing an asynchronous load in conjunction with a preset,
the MAX+PLUS II software provides preset control by using the clear and
inverting the input and output of the register. Asserting LABCTRL2 clears
the register, while asserting LABCTRL1 loads the register. The
MAX+PLUS II software inverts the signal that drives the DATA3 signal to
account for the inversion of the register’s output.
Asynchronous Load without Clear or Preset
When implementing an asynchronous load without the clear or preset,
LABCTRL1 implements the asynchronous load of DATA3 by controlling the
register preset and clear.
16 Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
FastTrack Interconnect
In the FLEX 8000 architecture, connections between LEs and device I/O
pins are provided by the FastTrack Interconnect, a series of continuous
horizontal (row) and vertical (column) routing channels that traverse the
entire FLEX 8000 device. This device-wide routing structure provides
predictable performance even in complex designs. In contrast, the
segmented routing structure in FPGAs requires switch matrices to
connect a variable number of routing paths, which increases the delays
between logic resources and reduces performance.
The LABs within FLEX 8000 devices are arranged into a matrix of
columns and rows. Each row of LABs has a dedicated row interconnect
that routes signals both into and out of the LABs in the row. The row
interconnect can then drive I/O pins or feed other LABs in the device.
Figure 8 shows how an LE drives the row and column interconnect.
Figure 8. FLEX 8000 LAB Connections to Row & Column Interconnect
LE1
LE2
Row Channels
16 Column
Channels
Each LE drives up to
two column channels.
to Local
Feedback to Local
Feedback
Each LE drives one
row channel.
(1)
Note:
(1) See Table 4 for the number of row channels.
Altera Corporation 17
FLEX 8000 Pr o grammabl e Log i c Dev ic e Fam ily D ata Sh eet
FLEX 8000
3
Each LE in an LAB can drive up to two separate column interconnect
channels. Therefore, all 16 available column channels can be driven by the
LAB. The column channels run vertically across the entire device, and
share access to LABs in the same column but in different rows. The
MAX+PLUS II Compiler chooses which LEs must be connected to a
column channel. A row interconnect channel can be fed by the output of
the LE or by two column channels. These three signals feed a multiplexer
that connects to a specific row channel. Each LE is connected to one 3-to-1
multiplexer. In an LAB, the multiplexers provide all 16 column channels
with access to 8 row channels.
Each column of LABs has a dedicated column interconnect that routes
signals out of the LABs into the column. The column interconnect can then
drive I/O pins or feed into the row interconnect to route the signals to
other LABs in the device. A signal from the column interconnect, which
can be either the output of an LE or an input from an I/O pin, must
transfer to the row interconnect before it can enter an LAB. Table 4
summarizes the FastTrack Interconnect resources available in each
FLEX 8000 device.
Figure 9 shows the interconnection of four adjacent LABs, with row,
column, and local interconnects, as well as the associated cascade and
carry chains.
Table 4. FLEX 8000 FastTrack Interconnect Resources
Device Rows Channels per Row Columns Channels per Column
EPF8282A
EPF8282AV 2 168 13 16
EPF8452A 2 168 21 16
EPF8636A 3 168 21 16
EPF8820A 4 168 21 16
EPF81188A 6 168 21 16
EPF81500A 6 216 27 16
18 Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Figure 9. FLEX 8000 Device Interconnect Resources
Each LAB is named according to its physical row (A, B, C, etc.) and column (1, 2, 3, etc.) position within the device.
I/O Element
An IOE contains a bidirectional I/O buffer and a register that can be used
either as an input register for external data that requires a fast setup time,
or as an output register for data that requires fast clock-to-output
performance. IOEs can be used as input, output, or bidirectional pins. The
MAX+PLUS II Compiler uses the programmable inversion option to
automatically invert signals from the row and column interconnect where
appropriate. Figure 10 shows the IOE block diagram.
IOEIOE IOEIOE
LAB
A1 LAB
A2
LAB
B1 LAB
B2
LAB Local
Interconnect
Column
Interconnect Row
Interconnect
Cascade &
Carry Chain
IOE
IOE
IOE
IOE
IOE
IOE
IOEIOE
See Figure 11
for details.
See Figure 12
for details.
1
8
1
8
1
8
IOE
IOE
1
8
IOEIOE
Altera Corporation 19
FLEX 8000 Pr o grammabl e Log i c Dev ic e Fam ily D ata Sh eet
FLEX 8000
3
Figure 10. FLEX 8000 IOE
Numbers in parentheses are for EPF81500A devices only.
Row-to-IOE Connections
Figure 11 illustrates the connection between row interconnect channels
and IOEs. An input signal from an IOE can drive two separate row
channels. When an IOE is used as an output, the signal is driven by an
n-to-1 multiplexer that selects the row channels. The size of the
multiplexer varies with the number of columns in a device. EPF81500A
devices use a 27-to-1 multiplexer; EPF81188A, EPF8820A, EPF8636A, and
EPF8452A devices use a 21-to-1 multiplexer; and EPF8282A and
EPF8282AV devices use a 13-to-1 multiplexer. Eight IOEs are connected to
each side of the row channels.
From Row or Column
Interconnect
Slew-Rate
Control
To Row or Column
Interconnect
I/O Controls
6
(6)
CLRN
DQ
Programmable
Inversion
CLR0
CLR1/OE0
CLK1/OE1
CLK0
(OE [4..9])
OE2
OE3
VCC
VCC
20 Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Figure 11. FLEX 8000 Row-to-IOE Connections
Note:
(1) n = 13 for EPF8282A and EPF8282AV devices.
n = 21 for EPF8452A, EPF8636A, EPF8820A, and EPF81188A devices.
n = 27 for EPF81500A devices.
Column-to-IOE Connections
Two IOEs are located at the top and bottom of the column channels (see
Figure 12). When an IOE is used as an input, it can drive up to two
separate column channels. The output signal to an IOE can choose from 8
of the 16 column channels through an 8-to-1 multiplexer.
IOE 1
IOE 2
IOE 3
IOE 4
IOE 5
IOE 6
IOE 7
IOE 8
n
n
n
n
n
n
n
n
2
2
2
2
2
2
2
2
2222
2222
Row Interconnect 168
(216) 168
(216)
Each IOE can drive
up to two row
channels.
Each IOE is
driven by an
n-to-1
multiplexer.
Numbers in parentheses are for EPF81500A devices. See Note (1).
Altera Corporation 21
FLEX 8000 Pr o grammabl e Log i c Dev ic e Fam ily D ata Sh eet
FLEX 8000
3
Figure 12. FLEX 8000 Column-to-IOE Connections
In addition to general-purpose I/O pins, FLEX 8000 devices have four
dedicated input pins. These dedicated inputs provide low-skew, device-
wide signal distribution, and are typically used for global clock, clear, and
preset control signals. The signals from the dedicated inputs are available
as control signals for all LABs and I/O elements in the device. The
dedicated inputs can also be used as general-purpose data inputs because
they can feed the local interconnect of each LAB in the device.
Signals enter the FLEX 8000 device either from the I/O pins that provide
general-purpose input capability or from the four dedicated inputs. The
IOEs are located at the ends of the row and column interconnect channels.
I/O pins can be used as input, output, or bidirectional pins. Each I/O pin
has a register that can be used either as an input register for external data
that requires fast setup times, or as an output register for data that
requires fast clock-to-output performance. The MAX+PLUS II Compiler
uses the programmable inversion option to invert signals automatically
from the row and column interconnect when appropriate.
The clock, clear, and output enable controls for the IOEs are provided by
a network of I/O control signals. These signals can be supplied by either
the dedicated input pins or by internal logic. The IOE control-signal paths
are designed to minimize the skew across the device. All control-signal
sources are buffered onto high-speed drivers that drive the signals around
the periphery of the device. This “peripheral bus” can be configured to
provide up to four output enable signals (10 in EPF81500A devices), and
up to two clock or clear signals. Figure 13 on page 22 shows how two
output enable signals are shared with one clock and one clear signal.
IOE IOE
88
16
Column Interconnect
Each IOE is
driven by an
8-to-1
multiplexer.
Each IOE can drive
up to two column
signals.
22 Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
The signals for the peripheral bus can be generated by any of the four
dedicated inputs or signals on the row interconnect channels, as shown in
Figure 13. The number of row channels in a row that can drive the
peripheral bus correlates to the number of columns in the FLEX 8000
device. EPF8282A and EPF8282AV devices use 13 channels; EPF8452A,
EPF8636A, EPF8820A, and EPF81188A devices use 21 channels; and
EPF81500A devices use 27 channels. The first LE in each LAB is the source
of the row channel signal. The six peripheral control signals (12 in
EPF81500A devices) can be accessed by each IOE.
Figure 13. FLEX 8000 Peripheral Bus
Note:
(1) n = 13 for EPF8282A and EPF8282AV devices.
n = 21 for EPF8452A, EPF8636A, EPF8820A, and EPF81188A devices.
n = 27 for EPF81500A devices.
Dedicated
Inputs 4
1
2
n
Peripheral
C
ontrol
Signals
CLR0
CLR1/OE0
CLK0
CLK1/OE1
Row Channels
Programmable
Inversion
OE2
OE3
(OE[4..9])
(1)
Numbers in parentheses are for EPF81500A devices.
Altera Corporation 23
FLEX 8000 Pr o grammabl e Log i c Dev ic e Fam ily D ata Sh eet
FLEX 8000
3
Table 5 lists the source of the peripheral control signal for each FLEX 8000
device by row.
Output
Configuration
This section discusses slew-rate control and MultiVolt I/O interface
operation for FLEX 8000 devices.
Slew-Rate Control
The output buffer in each IOE has an adjustable output slew rate that can
be configured for low-noise or high-speed performance. A slow slew rate
reduces system noise by slowing signal transitions, adding a maximum
delay of 3.5 ns. The slow slew-rate setting affects only the falling edge of
a signal. The fast slew rate should be used for speed-critical outputs in
systems that are adequately protected against noise. Designers can specify
the slew rate on a pin-by-pin basis during design entry or assign a default
slew rate to all pins on a global basis.
fFor more information on high-speed system design, go to Application
Note 75 (High-Speed Board Designs).
Table 5. Row Sources of FLEX 8000 Peripheral Control Signals
Peripheral
Control Signal
EPF8282A
EPF8282AV EPF8452A EPF8636A EPF8820A EPF81188A EPF81500A
CLK0 Row A Row A Row A Row A Row E Row E
CLK1/OE1 Row B Row B Row C Row C Row B Row B
CLR0 Row A Row A Row B Row B Row F Row F
CLR1/OE0 Row B Row B Row C Row D Row C Row C
OE2 R ow A Row A Row A Row A Row D Row A
OE3 R ow B Row B Row B Row B Row A Row A
OE4 –––––Row B
OE5 –––––Row C
OE6 –––––Row D
OE7 –––––Row D
OE8 –––––Row E
OE9 –––––Row F
24 Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
MultiVolt I/O Interface
The FLEX 8000 device architecture supports the MultiVolt I/O interface
feature, which allows EPF81500A, EPF81188A, EPF8820A, and EPF8636A
devices to interface with systems with differing supply voltages. These
devices in all packages—except for EPF8636A devices in 84-pin PLCC
packages—can be set for 3.3-V or 5.0-V I/O pin operation. These devices
have one set of VCC pins for internal operation and input buffers
(VCCINT), and another set for I/O output drivers (VCCIO).
The VCCINT pins must always be connected to a 5.0-V power supply. With
a 5.0-V VCCINT level, input voltages are at TTL levels and are therefore
compatible with 3.3-V and 5.0-V inputs.
The VCCIO pins can be connected to either a 3.3-V or 5.0-V power supply,
depending on the output requirements. When the VCCIO pins are
connected to a 5.0-V power supply, the output levels are compatible with
5.0-V systems. When the VCCIO pins are connected to a 3.3-V power
supply, the output high is at 3.3 V and is therefore compatible with 3.3-V
or 5.0-V systems. Devices operating with VCCIO levels lower than 4.75 V
incur a nominally greater timing delay of tOD2 instead of tOD1. See Table 8
on page 26.
IEEE Std.
1149.1 (JTAG)
Boundary-Scan
Support
The EPF8282A, EPF8282AV, EPF8636A, EPF8820A, and EPF81500A
devices provide JTAG BST circuitry. FLEX 8000 devices with JTAG
circuitry support the JTAG instructions shown in Table 6.
Table 6. EPF8282A, EPF8282AV, EPF8636A, EPF8820A & EPF81500A JTAG Instructions
JTAG Instruction Description
SAMPL E/P R ELOAD Allow s a snap sh ot of the sign als at the dev ic e pins to be capt ured and exam ined during
normal device operation, and permits an initial data pattern to be output at the device pins.
EXTEST Allows the external circuitry and board-level interconnections to be tested by forcing a test
pat ter n at the out put pins and c apt uring test resu lts at the input pins.
BYPASS Plac es the 1-b it bypass regist er bet w een t he TDI and TDO pin s, wh ich allow s the BST
dat a to pass sync hronously thro ugh t he s elec te d dev ic e to ad jac ent dev ice s dur ing
norm al dev ic e operation.
Altera Corporation 25
FLEX 8000 Pr o grammabl e Log i c Dev ic e Fam ily D ata Sh eet
FLEX 8000
3
The instruction register length for FLEX 8000 devices is three bits. Table 7
shows the boundary-scan register length for FLEX 8000 devices.
FLEX 8000 devices that support JTAG include weak pull-ups on the JTAG
pins. Figure 14 shows the timing requirements for the JTAG signals.
Figure 14. EPF8282A, EPF8282AV, EPF8636A, EPF8820A & EPF81500A
JTAG Waveforms
Table 8 shows the timing parameters and values for EPF8282A,
EPF8282AV, EPF8636A, EPF8820A, and EPF81500A devices.
Table 7. FLEX 8000 Boundary-Scan Register Length
Device Boundary-Scan Register Length
EPF8 282A, EPF82 82AV 273
EPF8636A 417
EPF8820A 465
EPF81500A 645
TDO
TCK
tJPZX tJPCO
tJPH
tJPXZ
tJCP
tJPSU
tJCL
tJCH
TDI
TMS
Signal
to Be
Captured
Signal
to Be
Driven
tJSZX
tJSSU tJSH
tJSCO tJSXZ
26 Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
fFor detailed information on JTAG operation in FLEX 8000 devices, refer to
Application Note 39 (IEEE 1149.1 (JTAG) Boundary-Scan Testing in Altera
Devices).
Generic Testing Each FLEX 8000 device is functionally tested and specified by Altera.
Complete testing of each configurable SRAM bit and all logic
functionality ensures 100% configuration yield. AC test measurements for
FLEX 8000 devices are made under conditions equivalent to those shown
in Figure 15. Designers can use multiple test patterns to configure devices
during all stages of the production flow.
Table 8. JTAG Timing Parameters & Values
Symbol Parameter EPF8282A
EPF8282AV
EPF8636A
EPF8820A
EPF81500A
Unit
Min Max
tJCP TCK clock per iod 100 ns
tJCH TCK clock hig h time 50 ns
tJCL TCK clock low time 50 ns
tJPSU J T AG port setup ti me 20 ns
tJPH JTAG port hold time 45 ns
tJPCO JTAG port clock to output 25 ns
tJPZX JTAG port high-impedance to valid output 25 ns
tJPXZ J T AG port valid outp ut to high-impedance 25 ns
tJSSU C apture regis t er se tu p time 20 ns
tJSH Ca ptu re regis t er hold time 45 ns
tJSCO U pdate regis t er clo ck to outp ut 35 ns
tJSZX U pdate regis t er high-impedance to valid out put 35 ns
tJSXZ U pdate regis t er va lid out put to hig h-im pedance 35 ns
Altera Corporation 27
FLEX 8000 Pr o grammabl e Log i c Dev ic e Fam ily D ata Sh eet
FLEX 8000
3
Figure 15. FLEX 8000 AC Test Conditions
Operating
Conditions
Tables 9 through 12 provide information on absolute maximum ratings,
recommended operating conditions, operating conditions, and
capacitance for 5.0-V FLEX 8000 devices.
VCC
To T est
System
C1 (includes
JIG capacitance)
Device input
rise and fall
times < 3 ns
464
(703 )
Device
Output
250
(8.06 K)
Power supply transients can affect AC
measurements. Simultaneous transitions
of multiple outputs should be avoided for
accurate measurement. Threshold tests
must not be performed under AC
conditions. Large-amplitude, fast-ground-
current transients normally occur as the
device outputs discharge the load
capacitances. When these transients flow
through the parasitic inductance between
the device ground pin and the test system
ground, significant reductions in
observable noise immunity can result.
Numbers in parentheses are for 3.3-V
devices or outputs. Numbers without
parentheses are for 5.0-V devices or
outputs.
Table 9. FLEX 8000 5.0-V Device Absolute Maximum Ratings Note (1)
Symbol Parameter Conditions Min Max Unit
VCC Supply vol tag e With res pec t to ground (2) –2.0 7.0 V
VIDC input voltage –2.0 7.0 V
IOUT DC output current, per pin –25 25 mA
TSTG Stora ge te mp erat ure No bias –65 150 ° C
TAMB Ambient temperature Under bias –65 135 ° C
TJJunct ion te m perat ure Ceramic pac k ages , under bias 150 ° C
PQFP and R QF P, under bias 135 ° C
28 Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Table 10. FLEX 8000 5.0-V Device Recommended Operating Conditions
Symbol Parameter Conditions Min Max Unit
VCCINT Supply voltage for internal logic
and input buffers (3), (4) 4.75 (4.50) 5.25 (5.50) V
VCCIO Supply v olt age f or out put
buf fer s, 5.0 -V operation (3), (4) 4. 75 (4.50) 5. 25 (5.50) V
Supply voltage f or out put
buf fer s, 3.3 -V operation (3), (4) 3. 00 (3.00) 3. 60 (3.60) V
VIInp ut volt age –0.5 VCCINT + 0.5 V
VOOutput voltage 0 VCCIO V
TAOperating temp erat ure For commerc ial us e 0 70 ° C
For indus tr ial us e –40 85 ° C
tRInput rise time 40 ns
tFInput fall time 40 ns
Table 11. FLEX 8000 5.0-V Device DC Operating Conditions Notes (5), (6)
Symbol Parameter Conditions Min Typ Max Unit
VIH High- lev el input vo lta ge 2.0 VCCINT + 0.5 V
VIL Low- lev el input vo lta ge –0.5 0.8 V
VOH 5.0-V high-level TTL output
voltage IOH = –4 mA DC (7)
VCCIO = 4.75 V 2.4 V
3.3-V high-level TTL output
voltage IOH = –4 mA DC (7)
VCCIO = 3.00 V 2.4 V
3.3-V high-level CMOS output
voltage IOH = –0.1 mA DC (7)
VCCIO = 3.00 V VCCIO – 0.2 V
VOL 5.0-V low- lev el TTL out put
voltage IOL = 12 mA DC (7)
VCCIO = 4.75 V 0.45 V
3.3-V low- lev el TTL out put
voltage IOL = 12 mA DC (7)
VCCIO = 3.00 V 0.45 V
3.3-V low-level CMOS output
voltage IOL = 0.1 mA DC (7)
VCCIO = 3.00 V 0.2 V
IIInput leak age current VI = VCC or ground –10 10 µA
IOZ Tri-state output off-state
current VO = VCC or ground –40 40 µA
ICC0 VCC supp ly current (standb y) VI = gro und, no load 0.5 10 mA
Altera Corporation 29
FLEX 8000 Pr o grammabl e Log i c Dev ic e Fam ily D ata Sh eet
FLEX 8000
3
Notes to tables:
(1) See the Operating Requirements for Altera Devices Data Sheet.
(2) Minimum DC input is –0.5 V. During transitions, the inputs may undershoot to –2.0 V or overshoot to 7.0 V for input
currents less than 100 mA and periods shorter than 20 ns.
(3) The maximum VCC rise time is 100 ms.
(4) Numbers in parentheses are for industrial-temperature-range devices.
(5) Typical values are for TA = 25° C and VCC = 5.0 V.
(6) These values are specified in Table 10 on page 28.
(7) The IOH parameter refers to high-level TTL or CMOS output current; the IOL parameter refers to low-level TTL or
CMOS output current.
(8) Capacitance is sample-tested only.
Tables 13 through 16 provide information on absolute maximum ratings,
recommended operating conditions, operating conditions, and
capacitance for 3.3-V FLEX 8000 devices.
Table 12. FLEX 8000 5.0-V Device Capacitance Note (8)
Symbol Parameter Conditions Min Max Unit
CIN Input capacitance VIN = 0 V, f = 1.0 MHz 10 pF
COUT Out put ca pac it anc e VOUT = 0 V, f = 1.0 MHz 10 pF
Table 13. FLEX 8000 3.3-V Device Absolute Maximum Ratings Note (1)
Symbol Parameter Conditions Min Max Unit
VCC Supply vol tag e With res pec t to ground (2) –2.0 5.3 V
VIDC input voltage –2.0 5.3 V
IOUT DC output current, per pin –25 25 mA
TSTG Stora ge te mp erat ure No bias –65 150 ° C
TAMB Ambient temperature Under bias –65 135 ° C
TJJunct ion te m perat ure Plastic pac ka ges , un der bias 135 ° C
Table 14. FLEX 8000 3.3-V Device Recommended Operating Conditions
Symbol Parameter Conditions Min Max Unit
VCC Supply vol tag e (3) 3.0 3.6 V
VIInput vo lta ge –0. 3 VCC + 0.3 V
VOOutp ut volt age 0 VCC V
TAOperat ing t em perature For co m me rc ial us e 0 70 ° C
tRInput ris e time 40 ns
tFInput fa ll time 40 ns
30 Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Notes to tables:
(1) See the Operating Requirements for Altera Devices Data Sheet.
(2) Minimum DC input voltage is –0.3 V. During transitions, the inputs may undershoot to –2.0 V or overshoot to 5.3 V
for input currents less than 100 mA and periods shorter than 20 ns.
(3) The maximum VCC rise time is 100 ms. VCC must rise monotonically.
(4) These values are specified in Table 14 on page 29.
(5) The IOH parameter refers to high-level TTL output current; the IOL parameter refers to low-level TTL output current.
(6) Typical values are for TA = 25° C and VCC = 3.3 V.
(7) Capacitance is sample-tested only.
Figure 16 shows the typical output drive characteristics of 5.0-V
FLEX 8000 devices. The output driver is compliant with PCI Local Bus
Specification, Revision 2.2.
Table 15. FLEX 8000 3.3-V Device DC Operating Conditions Note (4)
Symbol Parameter Conditions Min Typ Max Unit
VIH Hig h-lev el input voltage 2.0 VCC + 0. 3 V
VIL Low -lev el input voltage –0.3 0.8 V
VOH Hig h-lev el out put voltage IOH = –0.1 mA DC (5) VCC – 0.2 V
VOL Low -lev el out put voltage IOL = 4 mA D C (5) 0.45 V
IIInput leakage current VI = VCC or ground –10 10 µA
IOZ Tri-state output off-state current VO = VCC or grou nd –40 40 µA
ICC0 VCC supply current (standby) VI = ground, no load (6) 0.3 10 mA
Table 16. FLEX 8000 3.3-V Device Capacitance Note (7)
Symbol Parameter Conditions Min Max Unit
CIN Input capacitance VIN = 0 V, f = 1.0 MHz 10 pF
COUT Output capacitance VOUT = 0 V, f = 1.0 MHz 10 pF
Altera Corporation 31
FLEX 8000 Pr o grammabl e Log i c Dev ic e Fam ily D ata Sh eet
FLEX 8000
3
Figure 16. Output Drive Characteristics of 5.0-V FLEX 8000 Devices (Except EPF8282A)
Figure 17 shows the typical output drive characteristics of 5.0-V
EPF8282A devices. The output driver is compliant with PCI Local Bus
Specification, Revision 2.2.
Figure 17. Output Drive Characteristics of EPF8282A Devices with 5.0-V VCCIO
Figure 18 shows the typical output drive characteristics of EPF8282AV
devices.
1234
50
100
150
200
IOL
IOH
Output Voltage (V)
12345
50
100
150
200
IOL
IOH
Output Voltage (V)
VCCINT = 5.0 V
VCCIO = 3.3 V
Room Temperature
VCCINT = 5.0 V
VCCIO = 5.0 V
Room Temperature
Typical IO
Output
Current (mA)
Typical IO
Output
Current (mA)
12345
30
60
90
150
120 VCC = 5.0 V
IOL
IOH
Room Temperature
Output Voltage (V)
Typical IO
Output
Current (mA)
32 Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Figure 18. Output Drive Characteristics of EPF8282AV Devices
Timing Model The continuous, high-performance FastTrack Interconnect routing
structure ensures predictable performance and accurate simulation and
timing analysis. This predictable performance contrasts with that of
FPGAs, which use a segmented connection scheme and hence have
unpredictable performance. Timing simulation and delay prediction are
available with the MAX+PLUS II Simulator and Timing Analyzer, or with
industry-standard EDA tools. The Simulator offers both pre-synthesis
functional simulation to evaluate logic design accuracy and post-
synthesis timing simulation with 0.1-ns resolution. The Timing Analyzer
provides point-to-point timing delay information, setup and hold time
prediction, and device-wide performance analysis.
Tables 17 through 20 describe the FLEX 8000 timing parameters and their
symbols.
1234
25
50
75
100
VCC = 3.3 V
I
OL
I
OH
Room Temperature
Output Voltage (V)
Typical I
O
Output
Current (mA)
Altera Corporation 33
FLEX 8000 Pr o grammabl e Log i c Dev ic e Fam ily D ata Sh eet
FLEX 8000
3
Table 17. FLEX 8000 Internal Timing Parameters Note (1)
Symbol Parameter
tIOD IOE regist er dat a delay
tIOC IOE regist er c ont rol si gnal delay
tIOE Outpu t ena ble delay
tIOCO I OE regis t er c loc k-to-output delay
tIOCOMB I OE co m binat orial delay
tIOSU I OE regis t er s etu p time before clock ; IOE reg ister rec ov ery time after as yn ch ronous clea r
tIOH IOE regist er hold time afte r clock
tIOCLR I OE regis t er c lear delay
tIN Input pad and buffer de lay
tOD1 Outpu t buff er and pad delay, slow sl ew rate = off, VCCIO = 5.0 V C1 = 35 pF (2)
tOD2 Outpu t buff er and pad delay, slow sl ew rate = off, VCCIO = 3.3 V C1 = 35 pF (2)
tOD3 Outpu t buff er and pad delay, slow sl ew rate = on, C1 = 35 pF (3)
tXZ Outpu t buff er dis able delay, C1 = 5 pF
tZX1 Output buffer enable delay, slow slew rate = off, VCCIO = 5. 0 V, C1 = 35 pF (2)
tZX2 Output buffer enable delay, slow slew rate = off, VCCIO = 3. 3 V, C1 = 35 pF (2)
tZX3 Outpu t buff er enable delay, slow s lew rate = on, C1 = 35 pF (3)
Table 18. FLEX 8000 LE Timing Parameters Note (1)
Symbol Parameter
tLUT LUT delay for data-in
tCLUT LUT delay for carry-in
tRLUT LUT delay for LE register feedback
tGATE C as ca de gat e delay
tCASC C as ca de ch ain routing delay
tCICO Carry-in to carry-out delay
tCGEN Data-in to carry-out dela y
tCGENR LE register feedback to carry -out delay
tCLE register c ont rol s ignal delay
tCH LE register c loc k high time
tCL LE register c loc k low tim e
tCO LE register c loc k -to -out put delay
tCOMB C om binatorial delay
tSU LE register setup time before clock; LE register recovery time after asynchronous preset, clear, or
load
tHLE register hold time aft er clo ck
tPRE LE register preset del ay
tCLR LE register c lear delay
34 Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Notes to tables:
(1) Internal timing parameters cannot be measured explicitly. They are worst-case delays based on testable and
external parameters specified by Altera. Internal timing parameters should be used for estimating device
performance. Post-compilation timing simulation or timing analysis is required to determine actual worst-case
performance.
(2) These values are specified in Table 10 on page 28 or Table 14 on page 29.
(3) For the tOD3 and tZX3 parameters, VCCIO = 3.3 V or 5.0 V.
(4) The tROW and tDIN_D delays are worst-case values for typical applications. Post-compilation timing simulation or
timing analysis is required to determine actual worst-case performance.
(5) External reference timing characteristics are factory-tested, worst-case values specified by Altera. A representative
subset of signal paths is tested to approximate typical device applications.
(6) For more information on test conditions, see Application Note 76 (Understanding FLEX 8000 Timing).
(7) This parameter is a guideline that is sample-tested only and is based on extensive device characterization. This
parameter applies to global and non-global clocking, and for LE and I/O element registers.
The FLEX 8000 timing model shows the delays for various paths and
functions in the circuit. See Figure 19. This model contains three distinct
parts: the LE; the IOE; and the interconnect, including the row and column
FastTrack Interconnect, LAB local interconnect, and carry and cascade
interconnect paths. Each parameter shown in Figure 19 is expressed as a
worst-case value in Tables 22 through 49. Hand-calculations that use the
FLEX 8000 timing model and these timing parameters can be used to
estimate FLEX 8000 device performance. Timing simulation or timing
analysis after compilation is required to determine the final worst-case
performance. Table 21 summarizes the interconnect paths shown in
Figure 19.
fFor more information on timing parameters, go to Application Note 76
(Understanding FLEX 8000 Timing).
Table 19. FLEX 8000 Interconnect Timing Parameters Note (1)
Symbol Parameter
tLABCASC Ca scade delay bet w een LEs in different LABs
tLABCARRY Carry delay bet we en LEs in dif fer ent LABs
tLOCAL LAB loc al int erc onnect delay
tROW Ro w interc onnect rou tin g delay (4)
tCOL Co lum n int erc onnect routing delay
tDIN_C De dic at ed input to LE control delay
tDIN_D De dic at ed input to LE data delay (4)
tDIN_IO Dedicated input to IOE control delay
Table 20. FLEX 8000 External Reference Timing Characteristics Note (5)
Symbol Parameter
tDRR Regist er-t o-register delay via 4 LE s, 3 row inter co nnec t s, and 4 loc al int erc onnects (6)
tODH Output data hold time afte r clock (7)
Altera Corporation 35
FLEX 8000 Pr o grammabl e Log i c Dev ic e Fam ily D ata Sh eet
FLEX 8000
3
Figure 19. FLEX 8000 Timing Model
t
CO
t
COMB
t
SU
t
H
t
PRE
t
CLR
Register
Delays
LUT Delay
t
LUT
t
RLUT
t
CLUT
Carry Chain
Delay
Register
Control
Carry-In from
Previous LE Cascade-In from
Previous LE
LE-Out
t
LABCASC
t
LABCARRY
Cascade-Out
to Next LE in
Next LAB
Carry-Out
to Next LE
in Next
LAB
LE
Dedicated
Input Delays
I/O Pin
t
IOC
t
IOE
t
IN
t
IOD
I/O Register
Delays
Output Data
Delay
I/O Register
Control
Input
Delay
Output
Delays
t
IOCO
t
IOCOMB
t
IOSU
t
IOH
t
IOCLR
t
OD1
t
OD2
t
OD3
t
XZ
t
ZX1
t
ZX2
t
ZX3
IOE
Data-In
t
COL
t
ROW
t
LOCAL
Carry-Out
to Next LE
in Same
LAB
Cascade-Out
to Next LE in
Same LAB
Cascade
Gate Delay
t
GATE
t
CGEN
t
CGENR
t
CICO
t
DIN_D
t
DIN_C
t
DIN_IO
t
CASC
Cascade
Routing Delay
t
C
36 Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Tables 22 through 49 show the FLEX 8000 internal and external timing
parameters.
Table 21. FLEX 8000 Timing Model Interconnect Paths
Source Destination Total Delay
LE-Out LE in same LAB tLOCAL
LE-Out LE in same row, different LAB tROW + t LOCAL
LE-Out LE in different row tCOL + tROW + tLOCAL
LE-Out IOE on column tCOL
LE-Out IOE on row tROW
IOE on row LE in same row tROW + t LOCAL
IOE on colu mn An y LE tCOL + t ROW + tLOCAL
Table 22. EPF8282A Internal I/O Element Timing Parameters
Symbol Speed Grade Unit
A-2 A-3 A-4
Min Max Min Max Min Max
tIOD 0.7 0.8 0.9 ns
tIOC 1.7 1.8 1.9 ns
tIOE 1.7 1.8 1.9 ns
tIOCO 1.0 1.0 1.0 ns
tIOCOMB 0.3 0.2 0.1 ns
tIOSU 1.4 1.6 1.8 ns
tIOH 0.0 0.0 0.0 ns
tIOCLR 1.2 1.2 1.2 ns
tIN 1.5 1.6 1.7 ns
tOD1 1.1 1.4 1.7 ns
tOD2 –––ns
tOD3 4.6 4.9 5.2 ns
tXZ 1.4 1.6 1.8 ns
tZX1 1.4 1.6 1.8 ns
tZX2 –––ns
tZX3 4.9 5.1 5.3 ns
Altera Corporation 37
FLEX 8000 Pr o grammabl e Log i c Dev ic e Fam ily D ata Sh eet
FLEX 8000
3
Table 23. EPF8282A Interconnect Timing Parameters
Symbol Speed Grade Unit
A-2 A-3 A-4
Min Max Min Max Min Max
tLABCASC 0.3 0.3 0.4 ns
tLABCARRY 0.3 0.3 0.4 ns
tLOCAL 0.5 0.6 0.8 ns
tROW 4.2 4.2 4.2 ns
tCOL 2.5 2.5 2.5 ns
tDIN_C 5.0 5.0 5.5 ns
tDIN_D 7.2 7.2 7.2 ns
tDIN_IO 5.0 5.0 5.5 ns
38 Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Table 24. EPF8282A LE Timing Parameters
Symbol Speed Grade Unit
A-2 A-3 A-4
Min Max Min Max Min Max
tLUT 2.0 2.5 3.2 ns
tCLUT 0.0 0.0 0.0 ns
tRLUT 0.9 1.1 1.5 ns
tGATE 0.0 0.0 0.0 ns
tCASC 0.6 0.7 0.9 ns
tCICO 0.4 0.5 0.6 ns
tCGEN 0.4 0.5 0.7 ns
tCGENR 0.9 1.1 1.5 ns
tC1.6 2.0 2.5 ns
tCH 4.0 4.0 4.0 ns
tCL 4.0 4.0 4.0 ns
tCO 0.4 0.5 0.6 ns
tCOMB 0.4 0.5 0.6 ns
tSU 0.8 1.1 1.2 ns
tH0.9 1.1 1.5 ns
tPRE 0.6 0.7 0.8 ns
tCLR 0.6 0.7 0.8 ns
Table 25. EPF8282A External Timing Parameters
Symbol Speed Grade Unit
A-2 A-3 A-4
Min Max Min Max Min Max
tDRR 15.8 19.8 24.8 ns
tODH 1.0 1.0 1.0 ns
Altera Corporation 39
FLEX 8000 Pr o grammabl e Log i c Dev ic e Fam ily D ata Sh eet
FLEX 8000
3
Table 26. EPF8282AV I/O Element Timing Parameters
Symbol Speed Grade Unit
A-3 A-4
Min Max Min Max
tIOD 0.9 2.2 ns
tIOC 1.9 2.0 ns
tIOE 1.9 2.0 ns
tIOCO 1.0 2.0 ns
tIOCOMB 0.1 0.0 ns
tIOSU 1.8 2.8 ns
tIOH 0.0 0.2 ns
tIOCLR 1.2 2.3 ns
tIN 1.7 3.4 ns
tOD1 1.7 4.1 ns
tOD2 ––ns
tOD3 5.2 7.1 ns
tXZ 1.8 4.3 ns
tZX1 1.8 4.3 ns
tZX2 ––ns
tZX3 5.3 8.3 ns
Table 27. EPF8282AV Interconnect Timing Parameters
Symbol Speed Grade Unit
A-3 A-4
Min Max Min Max
tLABCASC 0.4 1.3 ns
tLABCARRY 0.4 0.8 ns
tLOCAL 0.8 1.5 ns
tROW 4.2 6.3 ns
tCOL 2.5 3.8 ns
tDIN_C 5.5 8.0 ns
tDIN_D 7.2 10.8 ns
tDIN_IO 5.5 9.0 ns
40 Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Table 28. EPF8282AV Logic Element Timing Parameters
Symbol Speed Grade Unit
A-3 A-4
Min Max Min Max
tLUT 3.2 7.3 ns
tCLUT 0.0 1.4 ns
tRLUT 1.5 5.1 ns
tGATE 0.0 0.0 ns
tCASC 0.9 2.8 ns
tCICO 0.6 1.5 ns
tCGEN 0.7 2.2 ns
tCGENR 1.5 3.7 ns
tC2.5 4.7 ns
tCH 4.0 6.0 ns
tCL 4.0 6.0 ns
tCO 0.6 0.9 ns
tCOMB 0.6 0.9 ns
tSU 1.2 2.4 ns
tH1.5 4.6 ns
tPRE 0.8 1.3 ns
tCLR 0.8 1.3 ns
Table 29. EPF8282AV External Timing Parameters
Symbol Speed Grade Unit
A-3 A-4
Min Max Min Max
tDRR 24.8 50.1 ns
tODH 1.0 1.0 ns
Altera Corporation 41
FLEX 8000 Pr o grammabl e Log i c Dev ic e Fam ily D ata Sh eet
FLEX 8000
3
Table 30. EPF8452A I/O Element Timing Parameters
Symbol Speed Grade Unit
A-2 A-3 A-4
Min Max Min Max Min Max
tIOD 0.7 0.8 0.9 ns
tIOC 1.7 1.8 1.9 ns
tIOE 1.7 1.8 1.9 ns
tIOCO 1.0 1.0 1.0 ns
tIOCOMB 0.3 0.2 0.1 ns
tIOSU 1.4 1.6 1.8 ns
tIOH 0.0 0.0 0.0 ns
tIOCLR 1.2 1.2 1.2 ns
tIN 1.5 1.6 1.7 ns
tOD1 1.1 1.4 1.7 ns
tOD2 ––ns
tOD3 4.6 4.9 5.2 ns
tXZ 1.4 1.6 1.8 ns
tZX1 1.4 1.6 1.8 ns
tZX2 ––ns
tZX3 4.9 5.1 5.3 ns
Table 31. EPF8452A Interconnect Timing Parameters
Symbol Speed Grade Unit
A-2 A-3 A-4
Min Max Min Max Min Max
tLABCASC 0.3 0.4 0.4 ns
tLABCARRY 0.3 0.4 0.4 ns
tLOCAL 0.5 0.5 0.7 ns
tROW 5.0 5.0 5.0 ns
tCOL 3.0 3.0 3.0 ns
tDIN_C 5.0 5.0 5.5 ns
tDIN_D 7.0 7.0 7.5 ns
tDIN_IO 5.0 5.0 5.5 ns
42 Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Table 32. EPF8452A LE Timing Parameters
Symbol Speed Grade Unit
A-2 A-3 A-4
Min Max Min Max Min Max
tLUT 2.0 2.3 3.0 ns
tCLUT 0.0 0.2 0.1 ns
tRLUT 0.9 1.6 1.6 ns
tGATE 0.0 0.0 0.0 ns
tCASC 0.6 0.7 0.9 ns
tCICO 0.4 0.5 0.6 ns
tCGEN 0.4 0.9 0.8 ns
tCGENR 0.9 1.4 1.5 ns
tC1.6 1.8 2.4 ns
tCH 4.0 4.0 4.0 ns
tCL 4.0 4.0 4.0 ns
tCO 0.4 0.5 0.6 ns
tCOMB 0.4 0.5 0.6 ns
tSU 0.8 1.0 1.1 ns
tH0.9 1.1 1.4 ns
tPRE 0.6 0.7 0.8 ns
tCLR 0.6 0.7 0.8 ns
Table 33. EPF8452A External Timing Parameters
Symbol Speed Grade Unit
A-2 A-3 A-4
Min Max Min Max Min Max
tDRR 16.0 20.0 25.0 ns
tODH 1.0 1.0 1.0 ns
Altera Corporation 43
FLEX 8000 Pr o grammabl e Log i c Dev ic e Fam ily D ata Sh eet
FLEX 8000
3
Table 34. EPF8636A I/O Element Timing Parameters
Symbol Speed Grade Unit
A-2 A-3 A-4
Min Max Min Max Min Max
tIOD 0.7 0.8 0.9 ns
tIOC 1.7 1.8 1.9 ns
tIOE 1.7 1.8 1.9 ns
tIOCO 1.0 1.0 1.0 ns
tIOCOMB 0.3 0.2 0.1 ns
tIOSU 1.4 1.6 1.8 ns
tIOH 0.0 0.0 0.0 ns
tIOCLR 1.2 1.2 1.2 ns
tIN 1.5 1.6 1.7 ns
tOD1 1.1 1.4 1.7 ns
tOD2 1.6 1.9 2.2 ns
tOD3 4.6 4.9 5.2 ns
tXZ 1.4 1.6 1.8 ns
tZX1 1.4 1.6 1.8 ns
tZX2 1.9 2.1 2.3 ns
tZX3 4.9 5.1 5.3 ns
Table 35. EPF8636A Interconnect Timing Parameters
Symbol Speed Grade Unit
A-2 A-3 A-4
Min Max Min Max Min Max
tLABCASC 0.3 0.4 0.4 ns
tLABCARRY 0.3 0.4 0.4 ns
tLOCAL 0.5 0.5 0.7 ns
tROW 5.0 5.0 5.0 ns
tCOL 3.0 3.0 3.0 ns
tDIN_C 5.0 5.0 5.5 ns
tDIN_D 7.0 7.0 7.5 ns
tDIN_IO 5.0 5.0 5.5 ns
44 Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Table 36. EPF8636A LE Timing Parameters
Symbol Speed Grade Unit
A-2 A-3 A-4
Min Max Min Max Min Max
tLUT 2.0 2.3 3.0 ns
tCLUT 0.0 0.2 0.1 ns
tRLUT 0.9 1.6 1.6 ns
tGATE 0.0 0.0 0.0 ns
tCASC 0.6 0.7 0.9 ns
tCICO 0.4 0.5 0.6 ns
tCGEN 0.4 0.9 0.8 ns
tCGENR 0.9 1.4 1.5 ns
tC1.6 1.8 2.4 ns
tCH 4.0 4.0 4.0 ns
tCL 4.0 4.0 4.0 ns
tCO 0.4 0.5 0.6 ns
tCOMB 0.4 0.5 0.6 ns
tSU 0.8 1.0 1.1 ns
tH0.9 1.1 1.4 ns
tPRE 0.6 0.7 0.8 ns
tCLR 0.6 0.7 0.8 ns
Table 37. EPF8636A External Timing Parameters
Symbol Speed Grade Unit
A-2 A-3 A-4
Min Max Min Max Min Max
tDRR 16.0 20.0 25.0 ns
tODH 1.0 1.0 1.0 ns
Altera Corporation 45
FLEX 8000 Pr o grammabl e Log i c Dev ic e Fam ily D ata Sh eet
FLEX 8000
3
Table 38. EPF8820A I/O Element Timing Parameters
Symbol Speed Grade Unit
A-2 A-3 A-4
MinMaxMinMaxMinMax
tIOD 0.7 0.8 0.9 ns
tIOC 1.7 1.8 1.9 ns
tIOE 1.7 1.8 1.9 ns
tIOCO 1.0 1.0 1.0 ns
tIOCOMB 0.3 0.2 0.1 ns
tIOSU 1.4 1.6 1.8 ns
tIOH 0.0 0.0 0.0 ns
tIOCLR 1.2 1.2 1.2 ns
tIN 1.5 1.6 1.7 ns
tOD1 1.1 1.4 1.7 ns
tOD2 1.6 1.9 2.2 ns
tOD3 4.6 4.9 5.2 ns
tXZ 1.4 1.6 1.8 ns
tZX1 1.4 1.6 1.8 ns
tZX2 1.9 2.1 2.3 ns
tZX3 4.9 5.1 5.3 ns
Table 39. EPF8820A Interconnect Timing Parameters
Symbol Speed Grade Unit
A-2 A-3 A-4
MinMaxMinMaxMinMax
tLABCASC 0.3 0.3 0.4 ns
tLABCARRY 0.3 0.3 0.4 ns
tLOCAL 0.5 0.6 0.8 ns
tROW 5.0 5.0 5.0 ns
tCOL 3.0 3.0 3.0 ns
tDIN_C 5.0 5.0 5.5 ns
tDIN_D 7.0 7.0 7.5 ns
tDIN_IO 5.0 5.0 5.5 ns
46 Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Table 40. EPF8820A LE Timing Parameters
Symbol Speed Grade Unit
A-2 A-3 A-4
Min Max Min Max Min Max
tLUT 2.0 2.5 3.2 ns
tCLUT 0.0 0.0 0.0 ns
tRLUT 0.9 1.1 1.5 ns
tGATE 0.0 0.0 0.0 ns
tCASC 0.6 0.7 0.9 ns
tCICO 0.4 0.5 0.6 ns
tCGEN 0.4 0.5 0.7 ns
tCGENR 0.9 1.1 1.5 ns
tC1.6 2.0 2.5 ns
tCH 4.0 4.0 4.0 ns
tCL 4.0 4.0 4.0 ns
tCO 0.4 0.5 0.6 ns
tCOMB 0.4 0.5 0.6 ns
tSU 0.8 1.1 1.2 ns
tH0.9 1.1 1.5 ns
tPRE 0.6 0.7 0.8 ns
tCLR 0.6 0.7 0.8 ns
Table 41. EPF8820A External Timing Parameters
Symbol Speed Grade Unit
A-2 A-3 A-4
Min Max Min Max Min Max
tDRR 16.0 20.0 25.0 ns
tODH 1.0 1.0 1.0 ns
Altera Corporation 47
FLEX 8000 Pr o grammabl e Log i c Dev ic e Fam ily D ata Sh eet
FLEX 8000
3
Table 42. EPF81188A I/O Element Timing Parameters
Symbol Speed Grade Unit
A-2 A-3 A-4
Min Max Min Max Min Max
tIOD 0.7 0.8 0.9 ns
tIOC 1.7 1.8 1.9 ns
tIOE 1.7 1.8 1.9 ns
tIOCO 1.0 1.0 1.0 ns
tIOCOMB 0.3 0.2 0.1 ns
tIOSU 1.4 1.6 1.8 ns
tIOH 0.0 0.0 0.0 ns
tIOCLR 1.2 1.2 1.2 ns
tIN 1.5 1.6 1.7 ns
tOD1 1.1 1.4 1.7 ns
tOD2 1.6 1.9 2.2 ns
tOD3 4.6 4.9 5.2 ns
tXZ 1.4 1.6 1.8 ns
tZX1 1.4 1.6 1.8 ns
tZX2 1.9 2.1 2.3 ns
tZX3 4.9 5.1 5.3 ns
Table 43. EPF81188A Interconnect Timing Parameters
Symbol Speed Grade Unit
A-2 A-3 A-4
Min Max Min Max Min Max
tLABCASC 0.3 0.3 0.4 ns
tLABCARRY 0.3 0.3 0.4 ns
tLOCAL 0.5 0.6 0.8 ns
tROW 5.0 5.0 5.0 ns
tCOL 3.0 3.0 3.0 ns
tDIN_C 5.0 5.0 5.5 ns
tDIN_D 7.0 7.0 7.5 ns
tDIN_IO 5.0 5.0 5.5 ns
48 Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Table 44. EPF81188A LE Timing Parameters
Symbol Speed Grade Unit
A-2 A-3 A-4
Min Max Min Max Min Max
tLUT 2.0 2.5 3.2 ns
tCLUT 0.0 0.0 0.0 ns
tRLUT 0.9 1.1 1.5 ns
tGATE 0.0 0.0 0.0 ns
tCASC 0.6 0.7 0.9 ns
tCICO 0.4 0.5 0.6 ns
tCGEN 0.4 0.5 0.7 ns
tCGENR 0.9 1.1 1.5 ns
tC1.6 2.0 2.5 ns
tCH 4.0 4.0 4.0 ns
tCL 4.0 4.0 4.0 ns
tCO 0.4 0.5 0.6 ns
tCOMB 0.4 0.5 0.6 ns
tSU 0.8 1.1 1.2 ns
tH0.9 1.1 1.5 ns
tPRE 0.6 0.7 0.8 ns
tCLR 0.6 0.7 0.8 ns
Table 45. EPF81188A External Timing Parameters
Symbol Speed Grade Unit
A-2 A-3 A-4
Min Max Min Max Min Max
tDRR 16.0 20.0 25.0 ns
tODH 1.0 1.0 1.0 ns
Altera Corporation 49
FLEX 8000 Pr o grammabl e Log i c Dev ic e Fam ily D ata Sh eet
FLEX 8000
3
Table 46. EPF81500A I/O Element Timing Parameters
Symbol Speed Grade Unit
A-2 A-3 A-4
Min Max Min Max Min Max
tIOD 0.7 0.8 0.9 ns
tIOC 1.7 1.8 1.9 ns
tIOE 1.7 1.8 1.9 ns
tIOCO 1.0 1.0 1.0 ns
tIOCOMB 0.3 0.2 0.1 ns
tIOSU 1.4 1.6 1.8 ns
tIOH 0.0 0.0 0.0 ns
tIOCLR 1.2 1.2 1.2 ns
tIN 1.5 1.6 1.7 ns
tOD1 1.1 1.4 1.7 ns
tOD2 1.6 1.9 2.2 ns
tOD3 4.6 4.9 5.2 ns
tXZ 1.4 1.6 1.8 ns
tZX1 1.4 1.6 1.8 ns
tZX2 1.9 2.1 2.3 ns
tZX3 4.9 5.1 5.3 ns
Table 47. EPF81500A Interconnect Timing Parameters
Symbol Speed Grade Unit
A-2 A-3 A-4
MinMaxMinMaxMinMax
tLABCASC 0.3 0.3 0.4 ns
tLABCARRY 0.3 0.3 0.4 ns
tLOCAL 0.5 0.6 0.8 ns
tROW 6.2 6.2 6.2 ns
tCOL 3.0 3.0 3.0 ns
tDIN_C 5.0 5.0 5.5 ns
tDIN_D 8.2 8.2 8.7 ns
tDIN_IO 5.0 5.0 5.5 ns
50 Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Table 48. EPF81500A LE Timing Parameters
Symbol Speed Grade Unit
A-2 A-3 A-4
Min Max Min Max Min Max
tLUT 2.0 2.5 3.2 ns
tCLUT 0.0 0.0 0.0 ns
tRLUT 0.9 1.1 1.5 ns
tGATE 0.0 0.0 0.0 ns
tCASC 0.6 0.7 0.9 ns
tCICO 0.4 0.5 0.6 ns
tCGEN 0.4 0.5 0.7 ns
tCGENR 0.9 1.1 1.5 ns
tC1.6 2.0 2.5 ns
tCH 4.0 4.0 4.0 ns
tCL 4.0 4.0 4.0 ns
tCO 0.4 0.5 0.6 ns
tCOMB 0.4 0.5 0.6 ns
tSU 0.8 1.1 1.2 ns
tH0.9 1.1 1.5 ns
tPRE 0.6 0.7 0.8 ns
tCLR 0.6 0.7 0.8 ns
Table 49. EPF81500A External Timing Parameters
Symbol Speed Grade Unit
A-2 A-3 A-4
Min Max Min Max Min Max
tDRR 16.1 20.1 25.1 ns
tODH 1.0 1.0 1.0 ns
Altera Corporation 51
FLEX 8000 Pr o grammabl e Log i c Dev ic e Fam ily D ata Sh eet
FLEX 8000
3
Power
Consumption
The supply power (P) for FLEX 8000 devices can be calculated with the
following equation:
P = PINT + PIO = [(ICCSTANDBY + ICCACTIVE) × VCC] + PIO
Typical ICCSTANDBY values are shown as ICC0 in Table 11 on page 28 and
Table 15 on page 30. The PIO value, which depends on the device output
load characteristics and switching frequency, can be calculated using the
guidelines given in Application Note 74 (Evaluating Power for Altera
Devices). The ICCACTIVE value depends on the switching frequency and
the application logic. This value can be calculated based on the amount of
current that each LE typically consumes.
The following equation shows the general formula for calculating
ICCACTIVE:
The parameters in this equation are shown below:
fMAX = Maximum operating frequency in MHz
N = Total number of logic cells used in the device
togLC = Average percentage of logic cells toggling at each clock
K = Constant, shown in Table 50
This calculation provides an ICC estimate based on typical conditions
with no output load. The actual ICC value should be verified during
operation because this measurement is sensitive to the actual pattern in
the device and the environmental operating conditions.
Figure 20 shows the relationship between ICC and operating frequency
for several LE utilization values.
ICCACTIVE KfMAX NtogLC µA
MHz LE×
----------------------------××××=
Table 50. Values for Constant K
Device K
5.0-V FLEX 8000 devices 75
3.3-V FLEX 8000 devices 60
52 Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Figure 20. FLEX 8000 ICCACTIVE vs. Operating Frequency
Configuration &
Operation
The FLEX 8000 architecture supports several configuration schemes to
load a design into the device(s) on the circuit board. This section
summarizes the device operating modes and available device
configuration schemes.
fFor more information, go to Application Note 33 (Configuring FLEX 8000
Devices) and Application Note 38 (Configuring Multiple FLEX 8000 Devices).
30 600
400
600
1,000
800
200
1,000 LEs
500 LEs
1,500 LEs
Frequency (MHz)
I
CC
Supply
Current (mA)
Frequency (MHz)
30 60
100
ICC Supply
Current (mA)
200 LEs
150 LEs
100 LEs
50 LEs
10
20
30
40
50
60
70
80
90
0
3.3-V FLEX 8000 Devices
5.0-V FLEX 8000 Devices
Altera Corporation 53
FLEX 8000 Pr o grammabl e Log i c Dev ic e Fam ily D ata Sh eet
FLEX 8000
3
Operating Modes
The FLEX 8000 architecture uses SRAM elements that require
configuration data to be loaded whenever the device powers up and
begins operation. The process of physically loading the SRAM
programming data into the device is called configuration. During
initialization, which occurs immediately after configuration, the device
resets registers, enables I/O pins, and begins to operate as a logic device.
The I/O pins are tri-stated during power-up, and before and during
configuration. The configuration and initialization processes together are
called command mode; normal device operation is called user mode.
SRAM elements allow FLEX 8000 devices to be reconfigured in-circuit
with new programming data that is loaded into the device. Real-time
reconfiguration is performed by forcing the device into command mode
with a device pin, loading different programming data, reinitializing the
device, and resuming user-mode operation. The entire reconfiguration
process requires less than 100 ms and can be used to dynamically
reconfigure an entire system. In-field upgrades can be performed by
distributing new configuration files.
Configuration Schemes
The configuration data for a FLEX 8000 device can be loaded with one of
six configuration schemes, chosen on the basis of the target application.
Both active and passive schemes are available. In the active configuration
schemes, the FLEX 8000 device functions as the controller, directing the
loading operation, controlling external configuration devices, and
completing the loading process. The clock source for all active
configuration schemes is an oscillator on the FLEX 8000 device that
operates between 2 MHz and 6 MHz. In the passive configuration
schemes, an external controller guides the FLEX 8000 device. Table 51
shows the data source for each of the six configuration schemes.
Table 51. Data Source for Configuration
Configuration Scheme Acronym Data Source
Active serial AS Altera configuration device
Active parallel up APU Parallel configuration device
Active parallel down APD Parallel configuration device
Passiv e se rial PS Serial da ta pa th
Passiv e parallel synchronou s PPS Int elligent host
Passiv e parallel asyn ch ronous PPA Intelligent hos t
54 Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Device
Pin-Outs
Tables 52 through 54 show the pin names and numbers for the dedicated
pins in each FLEX 8000 device package.
Table 52. FLEX 8000 84-, 100-, 144- & 160-Pin Package Pin-Outs (Part 1 of 3)
Pin Name 84-Pin
PLCC
EPF8282A
84-Pin
PLCC
EPF8452A
EPF8636A
100-Pin
TQFP
EPF8282A
EPF8282AV
100-Pin
TQFP
EPF8452A
144-Pin
TQFP
EPF8820A
160-Pin
PGA
EPF8452A
160-Pin
PQFP
EPF8820A
(1)
nSP (2) 75 75 75 76 110 R1 1
MSEL0 (2) 74 74 74 75 109 P2 2
MSEL1 (2) 53 53 51 51 72 A1 44
nSTATUS (2) 32 32 24 25 37 C13 82
nCONFIG (2) 33 33 25 26 38 A15 81
DCLK (2) 10 10 100 100 143 P14 125
CONF_DONE (2) 11 11 1 1 144 N13 124
nWS 30 30 22 23 33 F13 87
nRS 48 48 42 45 31 C6 89
RDCLK 49 49 45 46 12 B5 110
nCS 29 29 21 22 4 D15 118
CS 28 28 19 21 3 E15 121
RDYnBUSY 77 77 77 78 20 P3 100
CLKUSR 50 50 47 47 13 C5 107
ADD17 51 51 49 48 75 B4 40
ADD16 36 55 28 54 76 E2 39
ADD15 56 56 55 55 77 D1 38
ADD14 57 57 57 57 78 E1 37
ADD13 58 58 58 58 79 F3 36
ADD12 60 60 59 60 83 F2 32
ADD11 61 61 60 61 85 F1 30
ADD10 62 62 61 62 87 G2 28
ADD9 63 63 62 64 89 G1 26
ADD8 64 64 64 65 92 H1 22
ADD7 65 65 65 66 94 H2 20
ADD6 66 66 66 67 95 J1 18
ADD5 67 67 67 68 97 J2 16
ADD4 69 69 68 70 102 K2 11
ADD3 70 70 69 71 103 K1 10
ADD2 71 71 71 72 104 K3 8
ADD1 76 72 76 73 105 M1 7
Altera Corporation 55
FLEX 8000 Pr o grammabl e Log i c Dev ic e Fam ily D ata Sh eet
FLEX 8000
3
ADD0 78 76 78 77 106 N3 6
DATA7 3 2 90 89 131 P8 140
DATA6 4 4 91 91 132 P10 139
DATA5 6 6 92 95 133 R12 138
DATA4 7 7 95 96 134 R13 136
DATA3 8 8 97 97 135 P13 135
DATA2 9 9 99 98 137 R14 133
DATA1 13 13 4 4 138 N15 132
DATA0 14 14 5 5 140 K13 129
SDOUT (3) 79 78 79 79 23 P4 97
TDI (4) 55 45 (5) 54 96 17
TDO (4) 27 27 (5) 18 18 102
TCK (4), (6) 72 44 (5) 72 88 27
TMS (4) 20 43 (5) 11 86 29
TRST (7) 52 52 (8) 50 71 45
Dedicated
Inputs (10) 12, 31, 54,
73 12, 31 , 54,
73 3, 23, 53, 73 3, 24, 53,
74 9, 26, 82,
99 C3 , D14,
N2 , R15 14, 33, 94,
113
VCCINT 17, 38, 59,
80 17, 38 , 59,
80 6, 20, 37, 56,
70, 87 9, 32, 49,
59, 82 8, 28, 70,
90, 111 B2, C4, D3,
D8 , D12,
G3, G12,
H4 , H13,
J3, J12,
M4, M7,
M9, M13,
N12
3, 24, 46,
92, 114,
160
VCCIO 16, 40, 60,
69, 91,
112, 122,
141
23, 47, 57,
69, 79,
104, 127 ,
137, 149 ,
159
Table 52. FLEX 8000 84-, 100-, 144- & 160-Pin Package Pin-Outs (Part 2 of 3)
Pin Name 84-Pin
PLCC
EPF8282A
84-Pin
PLCC
EPF8452A
EPF8636A
100-Pin
TQFP
EPF8282A
EPF8282AV
100-Pin
TQFP
EPF8452A
144-Pin
TQFP
EPF8820A
160-Pin
PGA
EPF8452A
160-Pin
PQFP
EPF8820A
(1)
56 Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
GND 5, 26, 47, 68 5, 26, 47,
68 2, 13, 30, 44,
52, 63, 80,
94
19, 44, 69,
94 7, 17, 27,
39, 54,
80, 81,
100,101,
128, 14 2
C12, D4 ,
D7, D9,
D13, G4,
G13, H3,
H12, J4 ,
J13, L1,
M3, M8,
M12, M 15,
N4
12, 13, 34,
35, 51, 63,
75, 80, 83,
93, 103 ,
115, 126,
131, 143,
155
No Connec t
(N.C.) 2, 6, 13, 30,
37, 42, 43,
50, 52, 56,
63, 80, 87,
92, 93, 99
–––
Total User I/O
Pins (9) 64 64 74 64 108 116 116
Table 52. FLEX 8000 84-, 100-, 144- & 160-Pin Package Pin-Outs (Part 3 of 3)
Pin Name 84-Pin
PLCC
EPF8282A
84-Pin
PLCC
EPF8452A
EPF8636A
100-Pin
TQFP
EPF8282A
EPF8282AV
100-Pin
TQFP
EPF8452A
144-Pin
TQFP
EPF8820A
160-Pin
PGA
EPF8452A
160-Pin
PQFP
EPF8820A
(1)
Altera Corporation 57
FLEX 8000 Pr o grammabl e Log i c Dev ic e Fam ily D ata Sh eet
FLEX 8000
3
Table 53. FLEX 8000 160-, 192- & 208-Pin Package Pin-Outs (Part 1 of 2)
Pin Name 160-Pin
PQFP
EPF8452A
160-Pin
PQFP
EPF8636A
192-Pin PGA
EPF8636A
EPF8820A
208-Pin
PQFP
EPF8636A (1)
208-Pin
PQFP
EPF8820A (1)
208-Pin
PQFP
EPF81188A (1)
nSP (2) 120 1 R15 207 207 5
MSEL0 (2) 1173T154421
MSEL1 (2) 84 38 T3 49 49 33
nSTATUS (2) 37 83 B3 108 108 124
nCONFIG (2) 40 81 C3 103 103 107
DCLK (2) 1 120 C15 158 158 154
CONF_DONE
(2) 4 118 B15 153 153 138
nWS 30 89 C5 114 114 118
nRS 71 50 B5 66 116 121
RDCLK 73 48 C11 64 137 137
nCS 29 91 B13 116 145 142
CS 27 93 A16 118 148 144
RDYnBUSY 125 155 A8 201 127 128
CLKUSR 76 44 A10 59 134 134
ADD17 78 43 R5 57 43 46
ADD16 91 33 U3 43 42 45
ADD15 92 31 T5 41 41 44
ADD14 94 29 U4 39 40 39
ADD13 95 27 R6 37 39 37
ADD12 96 24 T6 31 35 36
ADD11 97 23 R7 30 33 31
ADD10 98 22 T7 29 31 30
ADD9 99 21 T8 28 29 29
ADD8 101 20U9242526
ADD7 102 19 U10 23 23 25
ADD6 103 18 U11 22 21 24
ADD5 104 17 U12 21 19 18
ADD4 105 13 R12 14 14 17
ADD3 106 11 U14 12 13 16
ADD2 109 9 U15101110
ADD1 110 7 R13 8 10 9
ADD0 123 157 U16 203 9 8
DATA7 144 137 H17 178 178 177
DATA6 150 132 G17 172 176 175
DATA5 152 129 F17 169 174 172
58 Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
DATA4 154 127 E17 165 172 170
DATA3 157 124 G15 162 171 168
DATA2 159 122 F15 160 167 166
DATA1 11 115 E16 149 165 163
DATA0 12 113 C16 147 162 161
SDOUT (3) 128 152 C7 (11) 198 124 119
TDI (4) 55 R11 72 20
TDO (4) 95 B9 120 129
TCK (4), (6) 57U87430–
TMS (4) 59U77632–
TRST (7) 40R35454–
Dedicated
Inputs (10) 5, 36, 85, 116 6, 35, 87, 116 A5, U5, U13,
A13 7, 45, 112,
150 17, 36, 121,
140 13, 41, 116,
146
VCCINT
(5.0 V) 21, 41, 53, 67,
80, 81, 100, 121,
133, 147, 160
4, 5, 26, 85 ,
106 C8, C9, C10,
R8, R9, R10,
R14
5, 6, 33, 110 ,
137 5, 6, 27, 4 8,
119, 141 4, 20, 35, 48,
50, 102, 114,
131, 147
VCCIO
(5.0 V or
3.3 V)
25, 41, 60, 70,
80, 10 7, 12 1,
140, 149, 160
D3, D4, D9,
D14, D15, G4,
G14, L4, L14,
P4, P9, P14
32, 55, 78, 91,
102, 138, 159,
182, 19 3, 20 6
26, 55, 69, 87,
102, 131, 159,
173, 191, 206
3, 19, 34, 49,
69, 87, 106,
123, 140 , 156 ,
174, 192
GND 13, 14, 28, 46,
60, 75, 93, 107 ,
108, 126, 140,
155
15, 16, 36, 37,
45, 51, 75, 84,
86, 96 , 97,
117, 126, 131,
154
C4, D7, D8,
D10, D11, H4,
H14, K4, K14,
P7, P8, P10 ,
P11
19, 20, 46, 47,
60, 67, 96,
109, 111, 124,
125, 151, 164,
171, 20 0
15, 16, 37, 38,
60, 78, 96,
109, 110, 120,
130, 142, 152,
164, 182, 200
11, 12, 27, 28,
42, 43, 60, 78,
96, 105, 115,
122, 132 , 139 ,
148, 155 , 159 ,
165, 183 , 201
No Connect
(N.C.) 2, 3, 38, 39, 70 ,
82, 83, 118, 119,
148
2, 39, 82, 119 C6, C 12, C13 ,
C14, E3, E15,
F3 , J3, J4,
J14, J15, N3 ,
N15, P3, P15,
R4 (12)
1, 2, 3, 16, 17,
18, 25, 26, 27,
34, 35, 36, 50,
51, 52, 53,
104, 105, 106,
107, 121, 122,
123, 130, 131,
132, 139, 140,
141, 154, 155,
156, 15 7, 20 8
1, 2, 3, 50, 51,
52, 53, 104,
105, 106, 107,
154, 155, 156,
157, 208
1, 2, 51, 52, 53,
54, 103, 104,
157, 158 , 207 ,
208
Total User
I/O P i n s (9) 116 114 132, 148 (13) 132 148 144
Table 53. FLEX 8000 160-, 192- & 208-Pin Package Pin-Outs (Part 2 of 2)
Pin Name 160-Pin
PQFP
EPF8452A
160-Pin
PQFP
EPF8636A
192-Pin PGA
EPF8636A
EPF8820A
208-Pin
PQFP
EPF8636A (1)
208-Pin
PQFP
EPF8820A (1)
208-Pin
PQFP
EPF81188A (1)
Altera Corporation 59
FLEX 8000 Pr o grammabl e Log i c Dev ic e Fam ily D ata Sh eet
FLEX 8000
3
Table 54. FLEX 8000 225-, 232-, 240-, 280- & 304-Pin Package Pin-Outs (Part 1 of 3)
Pin Name 225-Pin
BGA
EPF8820A
232-Pin
PGA
EPF81188A
240-Pin
PQFP
EPF81188A
240-Pin
PQFP
EPF81500A
280-Pin
PGA
EPF81500A
304-Pin
RQFP
EPF81500A
nSP (2) A15 C14 237 237 W1 304
MSEL0 (2) B14 G15 21 19 N1 26
MSEL1 (2) R15 L15 40 38 H3 51
nSTATUS (2) P2 L3 141 142 G19 178
nCONFIG (2) R1 R4 117 120 B18 152
DCLK (2) B2 C4 184 183 U18 230
CONF_DONE (2) A1 G3 160 161 M16 204
nWS L4 P1 133 134 F18 167
nRS K5 N1 137 138 G18 171
RDCLK F1 G2 158 159 M17 202
nCS D1 E2 166 167 N16 212
CS C1 E3 169 170 N18 215
RDYnBUSY J3 K2 146 147 J17 183
CLKUSR G2 H2 155 156 K19 199
ADD17 M14 R15 58 56 E3 73
ADD16 L12T175654E271
ADD15 M15 P15 54 52 F4 69
ADD14 L13M144745G160
ADD13 L14M154543H258
ADD12 K13 M16 43 41 H1 56
ADD11 K15 K15 36 34 J3 47
ADD10 J13 K17 34 32 K3 45
ADD9 J15 J14 32 30 K4 43
ADD8 G14 J15 29 27 L1 34
ADD7 G13 H17 27 25 L2 32
ADD6 G11 H15 25 23 M1 30
ADD5 F14 F16 18 16 N2 20
ADD4 E13 F15 16 14 N3 18
ADD3 D15 F14 14 12 N4 16
ADD2 D14D1575U18
ADD1 E12B1753U26
ADD0 C15C1531V14
DATA7 A7 A7 205 199 W13 254
DATA6 D7 D8 203 197 W14 252
DATA5 A6 B7 200 196 W15 250
60 Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
DATA4 A5 C7 198 194 W16 248
DATA3 B5 D7 196 193 W17 246
DATA2 E6 B5 194 190 V16 243
DATA1 D5 A3 191 189 U16 241
DATA0 C4 A2 189 187 V17 239
SDOUT (3) K1 N2 135 136 F19 169
TDI F1 5 (4) 63 (14) B1 (14) 80 (14)
TDO J2 (4) 117 C17 149
TCK (6) J14 (4) 116 (14) A19 (14) 148 (14)
TMS J12 (4) 64 (14) C2 (14) 81 (14)
TRST (7) P14 115 (14) A18 (14) 145 (14)
Dedicated Inputs
(10) F 4, L1, K12,
E15 C1, C17, R1,
R17 10, 51, 130,
171 8, 49, 131,
172 F1, F16, P3,
P19 12, 64, 164,
217
VCCINT
(5.0 V) F5, F 1 0 , E1 ,
L2, K4, M12,
P15, H1 3,
H1 4, B1 5,
C13
E4, H4, L4,
P12, L14,
H14, E14,
R14, U1
20, 42, 64, 66,
114, 128, 150,
172, 23 6
18, 40, 60, 62,
91, 114, 129,
151, 173, 209,
236
B17, D3, D15,
E8, E10, E12,
E14, R7, R9,
R11, R13,
R14, T14
24, 54, 77,
144, 79, 115,
162, 191, 218,
266, 301
VCCIO
(5.0 V or 3.3 V) H 3, H2, P 6,
R6, P10, N10,
R1 4, N13,
H1 5, H12,
D1 2, A1 4,
B10, A10, B6,
C6, A 2 , C3 ,
M4, R2
N10 , M13,
M5, K13, K5,
H13, H5, F5,
E10, E8, N8,
F13
19, 41, 65, 81,
99, 116 , 140 ,
162, 186, 202,
220, 23 5
17, 39, 61, 78,
94, 108, 130,
152, 174, 191,
205, 221 , 235
D14, E7, E9,
E11, E13, R6,
R8, R10, R12,
T13, T15
22, 53, 78, 99,
119, 137, 163,
193, 220, 244,
262, 282, 300
Table 54. FLEX 8000 225-, 232-, 240-, 280- & 304-Pin Package Pin-Outs (Part 2 of 3)
Pin Name 225-Pin
BGA
EPF8820A
232-Pin
PGA
EPF81188A
240-Pin
PQFP
EPF81188A
240-Pin
PQFP
EPF81500A
280-Pin
PGA
EPF81500A
304-Pin
RQFP
EPF81500A
Altera Corporation 61
FLEX 8000 Pr o grammabl e Log i c Dev ic e Fam ily D ata Sh eet
FLEX 8000
3
GND B1, D4, E1 4,
F7, F8, F9 ,
F1 2, G6 , G7,
G8, G9, G10,
H1, H4, H5,
H6, H7, H8,
H9, H10, H11,
J6, J7, J8 , J9,
J10, K6, K7,
K8, K9, K11,
L15, N3, P1
A1, D6, E11 ,
E7, E9, G4,
G5, G13,
G14, J5, J13,
K4, K14, L5,
L13, N4, N7,
N9, N11, N14
8, 9, 30, 31,
52, 53, 72, 90,
108, 115, 129,
139, 151, 161,
173, 185, 187,
193, 211, 229
6 , 7 , 28, 2 9,
50, 51, 71, 85,
92, 10 1, 11 8,
119, 140, 141,
162, 163, 184,
185, 186, 198,
208, 214, 228
D4, D5, D16,
E4, E5, E6,
E15, E16, F5,
F15, G5, G15,
H5, H15, J5,
J15, K5, K15,
L5, L15 , M5,
M15, N5 ,
N15, P4, P5,
P15, P16, R4,
R5, R15, R16,
T4, T5, T16,
U17
9, 11, 36, 38,
65, 67, 90,
108, 116 ,
128, 150,
151, 175, 177,
206, 208, 231,
232, 237, 253,
265, 273 , 291
No Connect
(N.C.) 61, 62, 119,
120, 181, 182,
239, 240
10, 21, 23, 25,
35, 37, 39, 40,
41, 42, 52, 55,
66, 68, 146,
147, 161, 173,
174, 176, 187,
188, 189, 190,
192, 194, 195,
205, 207, 219,
221, 233, 234,
235, 236, 302,
303
Tot al Use r I/O
Pins (9) 148 180 180 177 204 204
Table 54. FLEX 8000 225-, 232-, 240-, 280- & 304-Pin Package Pin-Outs (Part 3 of 3)
Pin Name 225-Pin
BGA
EPF8820A
232-Pin
PGA
EPF81188A
240-Pin
PQFP
EPF81188A
240-Pin
PQFP
EPF81500A
280-Pin
PGA
EPF81500A
304-Pin
RQFP
EPF81500A
62 Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Notes to tables:
(1) Perform a complete thermal analysis before committing a design to this device package. See Application Note 74
(Evaluating Power for Altera Devices) for more information.
(2) This pin is a dedicated pin and is not available as a user I/O pin.
(3) SDOUT will drive out during configuration. After configuration, it may be used as a user I/O pin. By default, the
MAX+PLUS II software will not use SDOUT as a user I/O pin; the user can override the MAX+PLUS II software and
use SDOUT as a user I/O pin.
(4) If the device is not configured to use the JTAG BST circuitry, this pin is available as a user I/O pin.
(5) JTAG pins are available for EPF8636A devices only. These pins are dedicated user I/O pins.
(6) If this pin is used as an input in user mode, ensure that it does not toggle before or during configuration.
(7) TRST is a dedicated input pin for JTAG use. This pin must be grounded if JTAG BST is not used.
(8) Pin 52 is a VCC pin on EPF8452A devices only.
(9) The user I/O pin count includes dedicated input pins and all I/O pins.
(10) Unused dedicated inputs should be tied to ground on the board.
(11) SDOUT does not exist in the EPF8636GC192 device.
(12) These pins are no connect (N.C.) pins for EPF8636A devices only. They are user I/O pins in EPF8820A devices.
(13) EPF8636A devices have 132 user I/O pins; EPF8820A devices have 148 user I/O pins.
(14) For EPF81500A devices, these pins are dedicated JTAG pins and are not available as user I/O pins. If JTAG BST is
not used, TDI, TCK, TMS, and TRST should be tied to GND.
Revision
History
The information contained in the FLEX 8000 Programmable Logic Device
Family Data Sheet version 11.1 supersedes information published in
previous versions. The FLEX 8000 Programmable Logic Device Family Data
Sheet version 11.1 contains the following change: minor textual updates.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Altera:
EPF8820AQC160-4 EPF8452ALC84-4N EPF8820ABC225-4 EPF8282ATC100-2 EPF81188AQI208-4
EPF8282ATI100-3N EPF81188AQC240-2 EPF8820ATC144-2 EPF8282ALC84-3 EPF8282ALC84-4N
EPF8636AQC208-4 EPF8636AQC160-4N EPF8452ALC84-4 EPF8282ALC84-2 EPF8282ATC100-3N
EPF81500AQC240-3 EPF81500AQC240-4 EPF8452ATC100-3 EPF8452AQC160-2 EPF8636AQC208-3
EPF81188AQC208-2 EPF81500AQC240-2N EPF8820ATC144-4N EPF8282ALC84-4 EPF8452ALC84-3
EPF8282ATC100-4N EPF8820AQC208-3 EPF8282ATC100-4 EPF8636AQC160-3N EPF81188AQC240-3
EPF8636ALC84-4N EPF8636ALC84-3 EPF81188AQC208-4 EPF8452ATC100-3N EPF8452ATC100-4N
EPF8820ATC144-2N EPF8636ALI84-4 EPF81500AQC240-3N EPF8820AQC208-2 EPF8282ATC100-2N
EPF8820AQC160-2 EPF8636ALC84-4 EPF8636AQC160-3 EPF8636AQC208-2 EPF8820ATC144-4
EPF8452ATC100-4 EPF8820ATC144-3 EPF81188AQC240-4 EPF8282ATI100-3 EPF8452AQC160-3
EPF8820AQC208-4 EPF8636AQC160-4 EPF81188AQC208-3 EPF8282ATC100-3 EPF8820AQC160-3
EPF81500AQC240-2 EPF8452AQC160-4 EPF8452ALI84-4