Dimensions: inch
Center Frequency Fo
Tolerance from Fo
Insertion Loss
Quality Factor Unloaded
50
Ω
loaded
Temperature Stability Turnover Temperature
Turnover Frequency
Freq. Temp. Coefficient
Frequency Aging
DC Insulation Resistance
RF Equivalent RLC Model Motional Resistance R1
Motional Inductance L1
Motional Capacitance C1
Shunt Capacitance C0
Operating temp. °C
Storage temp. °C
Max. Rating DC voltage V
RF Power Dissipation dBm
PIN NO. CONNECTIONS
1
3
2 & 4
Input/Output
Output/Input
Case Ground
ABRACON IS
ISO 9001 / QS 9000
CERTIFIED
ABRACON IS
CERTIFIED
30332
Esperanza, Rancho Santa Margarita, California
92688
tel 949-546-8000 | fax 949-546-8001 | www.abracon.com
|||||||||||||||
5 x 3.5 x 1.5mm
STANDARD SPECIFICATIONS:
OUTLINE DRAWING:
MARKING:
- ASR303.825 ZYX
(Z for month from A to L;
Y for year, I.e. 4 for 2004,
X: Traceability code)
TEST CIRCUIT:
NOTES:
1) Frequency aging is specified at 65°C or less.
2) The center frequency Fc, is the frequency of minimum IL with the resonator in the
specified test fixture in a 50Ω test system with VSWR <=1.2.
3) Unless otherwise specified, case temperature is 25°C ± 2°C.
4) The design model values are for reference only. The capacitance C0 is the
measured static capacitance between either pin 1 and ground or pin 3 to ground.
To 50
Ω
LoadTo 50
Ω
Load
4
1
2
3
MHz
KHz
dB
-
°C
KHz
ppm/°C2
ppm/year
M
Ω
µ
H
fF
pF
303.750
-
25
1.0
2.25
303.825
±75
1.8
14,950
1,950
40
Fc
0.032
±10
15
117.5302
2.3371
2.55
303.900
2.2
55
23
2.85
-40°C to +85°C
-40°C to +85°C
±10
0
Ω
Electrostatic Sensitive Device. Handle with precaution.
.XAM.PYT.NIMTINUSCITSIRETCARAHC
SMD ONE PORT 303.825 MHz SAW RESONATORSMD ONE PORT 303.825 MHz SAW RESONATOR
ASR303.825S2
ATTENTION: Abracon Corporation’s products are COTS – Commercial-Off-The-Shelf products; suitable for Commercial, Industrial and, where designated, Automotive Applications. Abracon’s products are not
specifically designed for Military, Aviation, Aerospace, Life-dependant Medical applications or any application requiring high reliability where component failure could result in loss of life and/or property. For
applications requiring high reliability and/or presenting an extreme operating environment, written consent and authorization from Abracon Corporation is required. Please contact Abracon Corporation for
more information.
ISO9001:2008
Pb
RoHS
Compliant