3 Low Signal Relay G5V-2
■Characteristics
Note: Data shown are of initial value.
■Characteristic Data
Contact resistance 50 mΩ max. G5V-2, G5V-2-H, 100 mΩ max. G5V-2-H1
Operate time 7 ms max. (mean value: approx. 3.5 ms)
Release time 3 ms max. (mean value: approx. 0.8 ms)
Bounce time Operate Mean value: approx. 0.5 ms
Release Mean value: approx. 3.5 ms
Operating frequency Mechanical 36,000 operations/hour
Electrical 1,800 operations/hour (under rated load)
Insulation resistance 1,000 MΩ min (at 500 VDC)
Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between coil and contacts
1,000 VAC, 50/60 Hz for 1 minute between contacts of different poles
750 VAC, 50/60 Hz for 1 minute between contacts of same poles
(500 VAC, 50/60 Hz for 1 minute between contacts of same poles for ultra-sensitive type)
Surge withstand voltage 1,500 V 10 X 160 µs (conforms to part 68 of FCC rules)
Vibration Mechanical durability 10 to 55 Hz, 1.50 mm (0.59 in) double amplitude
Malfunction durability
Shock Mechanical durability 1,000 m/s2 (approx. 100 G)
Malfunction durability 200 m/s2 (approx. 20 G), 100 m/s2 (approx. 10 G) for ultra-sensitive type
Ambient temperature Operating/storage -25° to 70°C (-13° to 158°F)
Humidity 35% to 85% RH
Service life Mechanical 15 million operations min. (at operating frequency of 36,000 operations/hour)
Electrical See “Characteristic Data”
Weight 6 g (0.21 oz)
Rated operating voltage (V) Rated operating current (A) Rated operating current (A)
--- 48 VDC coil voltage (standard type)
All other types and voltages
Maximum voltage (%)
Service life (X103 operations)
Rated operating current (A)
Maximum Switching Capacity Electrical Service Life Ambient Temperature vs. Maximum Voltage