CARDINAL COMPONENTSCARDINAL COMPONENTSCARDINAL COMPONENTS
Description TEST CONDITIONS Min Typ Max Unit
Duty Cycle:
TTL @ 1.4 V < 50 MHz, CL = 50 pF 45 55 %
4.5-5.5 Vdd 50–66 MHz, CL = 15 pF 45 55 %
66–125 MHz, CL = 25 pF 40 60 %
125–133 MHz, CL = 15 pF 40 60 %
Duty Cycle: < 66 MHz, CL< 25 pF 45 55 %
CMOS @ Vdd/2 66–125 MHz, CL< 25 pF 40 60 %
4.5-5.5 Vdd 125–133 MHz, CL< 15 pF 40 60 %
3.0–3.6 Vdd < 40 MHz, CL< 30 pF 45 55 %
40-100 MHz, CL< 15 pF 40 60 %
Output Clock Rise/Fall
0.8V–2.0V, 4.5-5.5 Vdd, CL = 50 1.8 ns
0.8V–2.0V, 4.5-5.5 Vdd, CL = 25 1.2 ns
0.8V–2.0V, 4.5-5.5 Vdd, CL = 15 0.9 ns
0.2–0.8Vdd, 4.5-5.5 Vdd, CL = 50 3.4 ns
0.2–0.8Vdd, 3.0–3.6 Vdd, CL = 30 4.0 ns
0.2–0.8Vdd, 3.0–3.6 Vdd, CL = 15 2.4 ns
Start Up Time From power on 2 ms
Power Down Delay Time
Synchronous PWR_DWN pin LOW to output Hi-Z T/2 T+10 ns
Asynchronous 10 15 ns
Output Disable Time
Synchronous OE pin LOW to output Hi-Z T/2 T+10 ns
Asynchronous T = Frequency oscillator period 10 15 ns
Output Enable Time 100 ns
< 33.000 MHz 40 50 ps
> 33.000, MHz 30 40 ps
Peak to Peak * < 33.000 MHz 100 250 ps
> 33.000 MHz 75 175 ps
Series CPP
Output Clock Switching Characteristics
* Jitter tested at > 1,000,000 samples, exceeding JEDEC std JESD65.
Field Programmable Blank Oscillator
instrument within seconds
•
Can be programmed twice
•
Programmed with the PG-3000, PG-3100 field oscillator programming
•
Standard Package Options
Cardinal Components, Inc.
155 Route 46 West
Wayne, NJ 07470
Rev: C-090414-11
TEL: (973)785-1333
E-MAIL: sales@cardinalxtal.com
WEB: http://www.cardinalxtal.com