Notes:
(1) Tested with pulses tp=20ms.
(2) Valid provided that electrodes are kept at ambient temperature.
(3) The ZMM1 is a silicon diode with operation in forward direction. Hence, the index of all parameters should be F instead of Z.
Connect the cathode electrode to the negative pole.
Type
Zener voltage range 1) Dynamic resistance Reverse leakage current Temp. coefficient
of Zener Voltage
Vznom IZT for VZT 2) rzjT and rzjk at IZK IR and IR 2) at VRTKVZ
VmA V mA A A V%/K
ZMM1 3) 0.75 5 0.7 ... 0.8 <8 <50 1 - - - -0.26 ... -0.23
ZMM2.0 2.0 5 1.9 ... 2.1 <85 <600 1 <100 <200 1 -0.09 ... -0.06
ZMM2.4 2.4 5 2.28 ... 2.56 <85 <600 1 <50 <100 1 -0.09 ... -0.06
ZMM2.7 2.7 5 2.5 ... 2.9 <85 <600 1 <10 <50 1 -0.09 ... -0.06
ZMM3.0 3.0 5 2.8 ... 3.2 <85 <600 1 <4 <40 1 -0.08 ... -0.05
ZMM3.3 3.3 5 3.1 ... 3.5 <85 <600 1 <2 <40 1 -0.08 ... -0.05
ZMM3.6 3.6 5 3.4 ... 3.8 <85 <600 1 <2 <40 1 -0.08 ... -0.05
ZMM3.9 3.9 5 3.7 ... 4.1 <85 <600 1 <2 <40 1 -0.08 ... -0.05
ZMM4.3 4.3 5 4.0 ... 4.6 <75 <600 1 <1 <20 1 -0.06 ... -0.03
ZMM4.7 4.7 5 4.4 ... 5.0 <60 <600 1 <0.5 <10 1 -0.05 ... +0.02
ZMM5.1 5.1 5 4.8 ... 5.4 <35 <550 1 <0.1 <2 1 -0.02 ... +0.02
ZMM5.6 5.6 5 5.2 ... 6.0 <25 <450 1 <0.1 <2 1 -0.05 ... +0.05
ZMM6.2 6.2 5 5.8 ... 6.6 <10 <200 1 <0.1 <2 2 0.03 ... 0.06
ZMM6.8 6.8 5 6.4 ... 7.2 <8 <150 1 <0.1 <2 3 0.03 ... 0.07
ZMM7.5 7.5 5 7.0 ... 7.9 <7 <50 1 <0.1 <2 5 0.03 ... 0.07
ZMM8.2 8.2 5 7.7 ... 8.7 <7 <50 1 <0.1 <2 6.2 0.03 ... 0.08
ZMM9.1 9.1 5 8.5 ... 9.6 <10 <50 1 <0.1 <2 6.8 0.03 ... 0.09
ZMM10 10 5 9.4 ... 10.6 <15 <70 1 <0.1 <2 7.5 0.03 ... 0.1
ZMM11 11 5 10.4 ... 11.6 <20 <70 1 <0.1 <2 8.2 0.03 ... 0.11
ZMM12 12 5 11.4 ... 12.7 <20 <90 1 <0.1 <2 9.1 0.03 ... 0.11
ZMM13 13 5 12.4 ... 14.1 <26 <110 1 <0.1 <2 10 0.03 ... 0.11
ZMM15 15 5 13.8 ... 15.6 <30 <110 1 <0.1 <2 11 0.03 ... 0.11
ZMM16 16 5 15.3 ... 17.1 <40 <170 1 <0.1 <2 12 0.03 ... 0.11
ZMM18 18 5 16.8 ... 19.1 <50 <170 1 <0.1 <2 13 0.03 ... 0.11
ZMM20 20 5 18.8 ... 21.2 <55 <220 1 <0.1 <2 15 0.03 ... 0.11
ZMM22 22 5 20.8 ... 23.3 <55 <220 1 <0.1 <2 16 0.04 ... 0.12
ZMM24 24 5 22.8 ... 25.6 <80 <220 1 <0.1 <2 18 0.04 ... 0.12
ZMM27 27 5 25.1 ... 28.9 <80 <220 1 <0.1 <2 20 0.04 ... 0.12
ZMM30 30 5 28 ... 32 <80 <220 1 <0.1 <2 22 0.04 ... 0.12
ZMM33 33 5 31 ... 35 <80 <220 1 <0.1 <2 24 0.04 ... 0.12
ZMM36 36 5 34 ... 38 <80 <220 1 <0.1 <2 27 0.04 ... 0.12
ZMM39 39 2.5 37 ... 41 <90 <500 0.5 <0.1 <5 30 0.04 ... 0.12
ZMM43 43 2.5 40 ... 46 <90 <500 0.5 <0.1 <5 33 0.04 ... 0.1 2
ZMM47 47 2.5 44 ... 50 <110 <600 0.5 <0.1 <5 36 0.04 ... 0.12
ZMM51 51 2.5 48 ... 54 <125 <700 0.5 <0.1 <10 39 0.04 ... 0.12
ZMM56 56 2.5 52 ... 60 <135 <700 0.5 <0.1 <10 43 0.04 ... 0.12
ZMM62 62 2.5 58 ... 66 <150 <1000 0.5 <0.1 <10 47 0.04 ... 0.1 2
ZMM68 68 2.5 64 ... 72 <200 <1000 0.5 <0.1 <10 51 0.04 ... 0.1 2
ZMM75 75 2.5 70 ... 79 <250 <1000 0.5 <0.1 <10 56 0.04 ... 0.1 2
ZMM82 82 2.5 77 ... 87 <300 <1500 0.25 <0.1 <10 62 0.05 ... 0.12
ZMM91 91 1 85 ... 96 <450 <2000 0.1 <0.1 <10 68 0.05 ... 0.12
ZMM100 100 1 94 ... 106 <450 <5000 0.1 <0.1 <10 75 0.05 ... 0.12
ZMM110 110 1 104 ... 116 <600 <5000 0.1 <0.1 <10 82 0.05 ... 0.12
ZMM120 120 1 114 ... 127 <800 <5500 0.1 <0.1 <10 91 0.05 ... 0.12
ZMM130 130 1 124 ... 141 <950 <6000 0.1 <0.1 <10 100 0.05 ... 0.12
ZMM150 150 1 138 ... 156 <1250 <6500 0.1 <0.1 <10 110 0.05 ... 0.12
ZMM160 160 1 153 ... 171 <1400 <7000 0.1 <0.1 <10 120 0.05 ... 0.12
ZMM180 180 1 168 ... 191 <1700 <8500 0.1 <0.1 <10 130 0.05 ... 0.12
ZMM200 200 1 188 ... 212 <2000 <10000 0.1 <0.1 <10 150 0.05 ... 0.12
2