Catalog 1308242 Issued 3-03 (PDF Rev. 9-07) P&B KU series KUP Enclosed Relay KUIP 8mm Coil to Contacts KUGP 3mm Contact Gap, 8mm Coil to Contacts KUEP 10 Amp 150VDC Load Switching KUMP 15 Amp 277VAC File E22575 File LR15734 RoHS Users should thoroughly review the technical data before selecting a product part number. It is recommended that users also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Ready Features Coil Data @ 25C * AC coils: 6-240VAC, 50/60 Hz. DC: 6-110VDC. * Contact arrangement up to 4PDT. * Wide selection of termination and mounting styles. * PC terminals available. * Push to test button and indicator lamps. * KUEP incorporates a blow out magnet for high voltage DC switching. * KUIP offers 8mm contact-to-coil spacing for a higher degree of isolation. * KUGP provides 3mm contact gap and 8mm contact-to-coil spacing. * Complete line of sockets and DIN rail. * Class B coil insulation. Voltage: 6 to 110VDC and 6 to 240VAC. Nominal Coil Power: DC Coils: 1.2 Watts - KUP, KUIP, KUMP, 1 - 3 pole; KUEP, 1 pole. DC Coils: 1.8 Watts - KUP, 4 pole; KUEP, 2 pole; KUGP. AC Coils: 2.0VA - KUP, KUIP, 1 - 2 pole; KUEP, 1 pole. AC Coils: 2.7VA - KUP, KUIP, 3 pole; KUEP, 2 pole; KUGP, KUMP. Coil Data Contact Data @ 25C Arrangements: See respective ordering information table. Materials: Fine silver (5 amp) silver-cadmium oxide (10 amp). Gold flash available as standard. Gold diffused and gold alloy on special order. Expected Mechanical Life: Contact Ratings Material Fine Silver SilverCadmium Oxide Arrangement All 1-2 Pole KUP KUIP KUGP KUEP All KUMP KUMP 3 Pole KUP KUIP 4 Pole KUEP SPST-NO KUEP 2PST-NO KUEP 2PDT UL/CSA Ratings 5 amps @ 28VDC or 240VAC 80% PF, 2.5 amp tungsten @120VAC, 1/2 amp @ 120VDC. 1/6 HP @120VAC, 1/3 HP @ 240VAC, 5 FLA, 15 LRA @ 250VAC (FLA covered by 30,000 operations). 10 amps @ 28VDC or 240VAC, 80% PF, 5 amp tungsten @ 120VAC, 3A 600VAC, 1/2 amp @ 120VDC. 1/3 HP @ 120VAC, 1/2 HP @ 240, 480, and 600VAC, 10 FLA 30 LRA @ 120VAC, 5 FLA, 15 LRA @ 250VAC.(FLA ratings covered by 30,000 operations) 15 amp @ 277VAC, 80% PF KUM KUMP 10 amp @ 28VDC or 120VAC, 80% PF, 6 2/3 amp @ 240VAC, 80% PF 10 amp per pole not to exceed 30 amp total @ 28VDC, 120VAC, 80% PF, 6 2/3 amp @ 240VAC, 80% PF Expected Life 100,000 1.2 Watt 1.8 Watt DC Ohms 10% Nom. I ma DC Ohms 10% Nom. I ma 21 238 14 360 32.1 187 20 300 120 100 80 150 472 51 320 75 1,800 26.7 1,260 38 10,000 11 6,720 16 AC Volts Nominal 2VA DC Ohms 15% 6 12 24 120 240 100,000 6 24 85 2,250 9,110 335 168 84 17.5 8.75 4.2 18 72 1,700 7,200 460 230 115 24 12 Must Operate Voltage: DC Coils: 75% of nominal voltage or less. AC Coils: 85% of nominal voltage or less. Operating Time (Excluding Bounce): 15 milliseconds, typical, at nominal voltage. Release Time (Excluding Bounce): 10 milliseconds, typical, at nominal voltage. 100,000 100,000 Environmental Data 100,000 5 amp @ 150VDC 100,000 (All other AC ratings apply KUEP.) Temperature Range: Operating: Enclosed Relays: -45C to maximum listed in table below. Open Relays: Add 15C to maximum listed. Max C +45C +50C KUP AC 3-4 pole DC 4 pole KUIP KUGP Initial Dielectric Strength KUEP Between Open Contacts: 1,200V rms; KUGP, 3,500V rms. Between Adjacent Contacts: 2,200V rms. Between Contacts and Coil: 2,200V rms; KUGP, KUIP, 3,750V rms. KUMP Dimensions are shown for reference purposes only. 2.7VA Nom. I ma DC Ohms 15% Nom. I ma Operate Data @ 25C 10 amp @ 150VDC 3 amp @ 150VDC DC Volts Nominal 5 6 12 24 48 110 Dimensions are in inches over (millimeters) unless otherwise specified. AC 2 pole AC 3 pole Specifications and availability subject to change. +55C +70C AC DC 1-2 pole 1-3 pole AC 3 pole AC 2 pole AC DC 1 pole 1-2 pole AC DC 1-2 pole 1-3 pole +75C +80C +95C AC 1-2 pole DC 1-3 pole DC 2 pole www.tycoelectronics.com Technical support: Refer to inside back cover. 723 Catalog 1308242 Issued 3-03 (PDF Rev. 9-07) Environmental Data (Continued) 40 OI 30 L OI .C Hz L 20 Co il 60 30 Co il .C Hz W at tD C 60 1. 8 60 50 VA 40 W at tD C 7 2. 50 1.2 Max. Ambient Temp. C 60 Termination: Quick connect, solder and PC board. Enclosure: Clear polycarbonate dust cover. Weight: 3.0 oz. (85g) approximately. 75 70 A 0V 2. Max. Ambient Temp. C Maximum Allowable Ambient Temperature vs. Voltage (KUP enclosed) 75 70 P&B Mechanical Data 20 100 110 120 130 140 150 160 % of Nominal Voltage DC 120 130 140 100 110 % Of Nominal 60 Hz. Voltage Ordering Information Typical Part No. > 1. Basic Series & Type: KU = Basic open relay. KUP = Basic enclosed relay. 2. Contact Arrangement: 1 = 1A (SPST-NO) 5 = 1C (SPDT) 11 = 2C (DPDT) KU KUP -14 A 1 5 F -120 14 = 3C (3PDT) 17 = 4C (4PDT) 3. Coil Input: A = AC 50/60 Hz. D = DC 4. Mountings: Type KU Codes Available 1,3,4 OPEN STYLE 1 = #6-32 stud, .218" (5.54mm) locating tab. 3 = #6-32 tapped core, .125" (3.18mm) locating tab. 4 = #6-32 tapped core, .218" (5.54mm) locating tab. KUP (through 3 poles) KUP (4 pole models) 1,2,3,4,5, A,E,T 1,3,5,A,E 1 = PLAIN CASE; 2 = with test button. 3 = with indicator lamp.* 4 = with test button & indicator lamp.* 5 = BRACKET MOUNT CASE. A = PLAIN CASE, #6-32 stud, locating tab. E = PLAIN CASE, tapped core, locating tab. T = TOP FLANGE CASE. * Indicator lamps are available on models with the following coils: 6-24VAC and DC, 110VDC and 120-240VAC. Only models with 120-240VAC coils are UL recognized. 5. Terminal & Contact Material: Type 1 & 2 Pole Models Codes 1, 5, 7, K Available 3 Pole Models 1, 5, 7 4 Pole Models 1**, 5**,7, 9 **4 pole KUP with .187" (4.75mm) quick connect/solder terminals will not plug into sockets. Must use .110" (2.79 mm) quick connect solder terminals for socket mounting. 1 = .187" (4.75mm) quick-connect/solder; silver, 5 amps. 5 = .187" (4.75mm) quick connect/solder; silver-cadmium oxide, 10 amps. 7 = .047" (1.19mm) printed circuit; silver-cadmium oxide, 10 amps. 9 = 4 pole KU, KUP: .110" (2.79mm) quick connect/solder; silver-cadmium oxide, 10 amps. K = .250" (6.35mm) quick connect; silver-cadmium oxide, 10 amps. 5A. Gold Flashed Contact Option: F = Optional gold flashing for silver and silver-cadmium oxide contacts. 6. Coil Voltage: To 240VAC, 50/60 Hz. or 110VDC. Note: All part numbers are RoHS compliant. Our authorized distributors are more likely to stock the following items for immediate delivery. KUP-5A15-24 KUP-5A15-120 KUP-5A15-240 KUP-5A55-120 KUP-5D15-12 KUP-5D15-24 KUP-5D55-12 KUP-5D55-24 KUP-11A11-120 Dimensions are shown for 724 reference purposes only. KUP-11A15-12 KUP-11A15-24 KUP-11A15-120 KUP-11A15-240 KUP-11A35-120 KUP-11A55-24 KUP-11A55-120 KUP-11AT5-120 KUP-11D11-24 KUP-11D15-5 KUP-11D15-12 KUP-11D15-24 KUP-11D15-110 KUP-11D35-24 KUP-11D55-6 KUP-11D55-12 KUP-11D55-24 KUP-11D55-48 Dimensions are in inches over (millimeters) unless otherwise specified. KUP-11D55-110 KUP-14A11-120 KUP-14A15-12 KUP-14A15-24 KUP-14A15-120 KUP-14A15-240 KUP-14A25-120 KUP-14A35-120 KUP-14A45-120 KUP-14A55-24 KUP-14A55-120 KUP-14A55-240 KUP-14D11-24 KUP-14D15-6 KUP-14D15-12 KUP-14D15-24 KUP-14D15-48 KUP-14D15-110 Specifications and availability subject to change. KUP-14D25-24 KUP-14D35-24 KUP-14D55-12 KUP-14D55-24 KUP-17A19-120 KUP-17A55-24 KUP-17D19-24 KUP-17D55-24 www.tycoelectronics.com Technical support: Refer to inside back cover. Catalog 1308242 Issued 3-03 (PDF Rev. 9-07) P&B Ordering Information High Isolation Design Typical Part No. > 1. Basic Series & Type: KUIP = Enclosed relay with 8mm contact to coil spacing. KUGP = Enclosed relay with 3mm open contact spacing and 8mm contact to coil spacing. (Form A and Form X arrangements only) 2. Contact Arrangement: 5 = 1 Form C (SPDT)* 7 = 2 Form A (DPST-NO) * Not offered on KUGP model. KUIP KUGP -5 A 5 5 -120 11 = 2 Form C (DPDT)* 14 = 3 Form C (3PDT)* 3. Coil Input: A = AC, 50/60 Hz. D = DC 4. Mountings: 1 = PLAIN CASE, SOCKET MOUNT. 5 = BRACKET MOUNT CASE. T = TOP FLANGE CASE. 5. Terminal & Contact Material: 3 = .047" (1.19mm) printed circuit board; silver. 6. Coil Voltage: To 240VAC, 50/60 Hz. or 110VDC. (For 277VAC, consult factory.) 5 = .187" (4.75mm) quick connect/solder; silver-cadmium oxide. See coil data tables. Note: All part numbers are RoHS compliant. Our authorized distributors are more likely to stock the following items for immediate delivery. KUGP-7D55-24 KUIP-5A55-120 KUIP-11D55-12 KUIP-11D55-24 KUIP-14A15-120 KUIP-14D15-12 KUIP-14D15-24 Ordering Information High Voltage DC Switching Typical Part No. > 1. Basic Series & Type: KUEP = Enclosed relay with magnetic blow-outs. 2. Contact Arrangement: 3 = 1X (SPST-NO-DM) 3. Coil Input: A = AC 50/60 Hz. 4. Mountings: 1 = PLAIN CASE; 3 = with indicator lamp.* 5 = BRACKET MOUNT CASE T = TOP FLANGE CASE. 5. 6. 7 = 2A (DPST-NO) KUEP -3 A 1 5 -120 11 = 2C (DPDT) D = DC *Indicator lamps are available on models with the following coils: 6-24VAC and DC, 110VDC and 120-240VAC. Only models with 120-240VAC coils are UL recognized. Terminal & Contact Material: 5 = .187" (4.75mm) quick connect/solder; silvercadmium-oxide. 7 = .047' (1.19mm) printed circuit; silver-cadmium-oxide. Coil Voltage: To 240VAC, 50/60 Hz. or 110VDC. (For 277VAC, consult factory.) Note: All part numbers are RoHS compliant. Our authorized distributors are more likely to stock the following items for immediate delivery. KUEP-3A15-120 KUEP-3D15-12 KUEP-3D15-24 Dimensions are shown for reference purposes only. KUEP-3D15-110 KUEP-7D15-24 KUEP-11A15-120 KUEP-11D15-12 KUEP-11D15-24 Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. 725 Catalog 1308242 Issued 3-03 (PDF Rev. 9-07) P&B Ordering Information 15 Amp Switching Typical Part No. > 1. Basic Series & Type: KUM = 15 amp open relay KUMP = 15 amp enclosed relay 2. Contact Arrangement: 1 = 1A (SPST-NO) 2 = 1B (SPST-NC) 3 = 1X (SPST-NO-DM) 4 = 1Y (SPST-NC-DB) 5 = 1C (SPDT) 6 = 1Z (SPDT-NC-NO [DB-DM]) 7 = 2A (DPST-NO) 8 = 2B (DPST-NC) 11 = 2C (DPDT) 12 = 3A (3PST-NO) 13 = 3B (3PST-NC) 14 = 3C (3PDT) 3. Coil Input: A = AC, 50/60 Hz. 4. Mountings: Type KUM OPEN STYLE 1 = #6-32 stud, .218" (5.54mm) locating tab. 2 = 2-hole bracket, #6-32 tapped. 3 = #6-32 tapped core, .125" (3.18mm) locating tab. 4 = #6-32 tapped core, .218" (5.54mm) locating tab. 5 = #6-32 tapped core, no locating tab. 5. KUM KUMP -14 A 1 8 -120 D = DC 1 = PLAIN CASE; 2 = with test button. 3 = with indicator lamp.* 4 = with test button & indicator lamp.* 5 = BRACKET MOUNT CASE; 6 = with test button. 7 = with indicator lamp.* 8 = with test button & indicator lamp.* 9 = STUD ON END OF PLAIN CASE. KUMP A = PLAIN CASE, #6-32 STUD LOCATING TAB; B = with test button. C = with indicator lamp.* D = with test button & indicator lamp.* E = PLAIN CASE, TAPPED CORE, LOCATING TAB; F = with test button. G = with indicator lamp.* H = with test button & indicator lamp.* T = TOP FLANGE CASE. *Indicator lamps are available on models with the following coils: 6-24VAC and DC, 110VDC and 120-240VAC. Only models with 120-240VAC coils are UL recognized. Terminal & Contact Material: Type 1 & 2 Pole Models Codes 6,8,9,G Available 3 Pole Models 6,8,9 6 = .205" (5.21mm) quick connect/solder; silver-cadmium-oxide. 8 = .187" (4.75mm) quick connect/solder; silver-cadmium-oxide. 9 = .047" (1.19mm) printed circuit; silver-cadmium-oxide. G = .250" (6.35mm) quick connect; silver-cadmium-oxide. (Not available on 3 pole models.) 6. Coil Voltage: To 240VAC, 50/60 Hz. or 110VDC (For 277VAC, consult factory.) Note: All part numbers are RoHS compliant. Our authorized distributors are more likely to stock the following items for immediate delivery. KUMP-11A18-24 KUMP-11A18-120 KUMP-11A18-240 Dimensions are shown for 726 reference purposes only. KUMP-11D18-12 KUMP-11D18-24 KUMP-11D18-110 Dimensions are in inches over (millimeters) unless otherwise specified. KUMP-14A18-24 KUMP-14A18-120 KUMP-14D18-12 KUMP-14D18-24 Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. Catalog 1308242 Issued 3-03 (PDF Rev. 9-07) P&B Outline Dimensions Open Relays Bracket Type 1.437 (36.50) .19 (4.8) X Is For Terminal Dimensions. See Terminal Drawings. 2.43 MAX.* (61.72) 2.33 MAX.** (59.18) 2.29 MAX.*** (58.17) X .63 (16.0) .63 (16.0) 1.468 MAX. (37.29) .031 REF. (.79) 1.391 (35.33) .218 (5.54) .109 MAX. (2.77) .065 (1.65) .437 (11.10) 1.52" (38.6mm) for bracket with 2-#6 32 tapped holes. 2.27 MAX.* (57.7) 2.171 MAX.** (55.14) 2.125 MAX.*** (53.98) Stud Type 2.27 MAX.* (57.7) 2.171 MAX.** (55.14) 2.125 MAX.*** (53.98) 1.391" (35.33mm) for #6-32 stud with .218" (5.54mm) locating tab. X X .16 (4.1) (2) #6-32 THREAD TAPPED HOLES 1.39 MAX.* (35.3) 1.29 MAX.** (32.8) 1.25 MAX.*** (31.8) 1 4 2 5 3 6 7 8 9 A 1.282" (32.56mm) for #6-32 tapped core with .125" (3.18mm) or .218" (5.54mm) locating tab. 2.046" (51.97mm) for relay with printed circuit terminals. STUD TYPE also available with .125" (3.18mm) tab, as well as without stud and locating tab. Models without stud have core tapped #6-32 THREAD, .25" (6.4mm) minimum depth. .031 REF. (.79) 1.282 MAX. (35.56) 1.687 MAX. B (42.85) .31 (7.9) #6-32 THREAD Seated Heights For Open Relays *Dimensions with .250" (6.35mm) terminals. **Dimensions with .110" (2.79mm) or .205"(5.21mm) terminals. ***Dimensions with .187" (4.75mm) terminals. .150 TAB WIDTH (3.81) Enclosed Relays Plain Case Core and Stud Mount Cases .187 (4.75) DIA. PUSH-TO-TEST BUTTON AVAILABLE ON KUP, & KUMP .288 (7.32) X 1 4 2 5 3 6 7 8 9 X X 1.43 MAX. (36.27) 1.74 MAX. (44.2) STUD with #6-32 THREAD or CORE TAPPED #6-32 .437 .010 (11.10 .25) 1.406 MAX. (35.71) B A X Is For Terminal Dimensions. See Teminal Drawings. X X .130 (3.30) 1.531 MAX. (38.89) .219 MAX. (5.56) 1.968 MAX. (49.99) 1.906 MAX. (48.41) 1.968 MAX. (49.99) 1.906 MAX. (48.41) 1.39 MAX.* (35.3) 1.29 MAX.** (32.8) 1.25 MAX.*** (31.8) .312 (7.92) Dimensions with .250" (6.35mm) terminals. Top Flange Case Dimensions with .110" (2.79mm), .187" (4.75mm and .205" 5.21mm) terminals. 1.518 MAX. (38.56) .078 TYP. (1.98) *Dimensions with .250" (6.35mm) terminals. 1 4 2 5 3 6 7 8 9 A **Dimensions with .110" (2.79mm) or .205" (5.21mm) terminals 1.713 .0 03 (43.51 .08) 1.373 .010 1.989 .0 03 (34.87 .25) (50.52) ***Dimensions with .187" (4.75mm) terminals. B 2.248 MAX. (57.10) Stud on End Case .178 TYP. (4.52) .085 MAX. (2.16) Bracket Mount Case 2.90 MAX. (73.7) X .078 R. TYP. (1.98) .75 (19.1) 1.531 MAX. (38.89) .375 (9.53) Dimensions are shown for reference purposes only. 2.500 (63.50) X X .437 (11.10) PUSH-TO-TESTBUTTON AVAILABLE ON KUP & KUMP 1.406 M AX. (35.71) 1.128 (28.65) .312 .625 TYP. TYP. (15.88) (7.92) 1.968 MAX. (49.99) 1.906 MAX. (48.41) .38 (9.7) .07 (1.8) Dimensions are in inches over (millimeters) unless otherwise specified. .06 (1.52) #6-32 THREAD .16 (4.1) 1.968 MAX. (49.99) 1.906 MAX. (48.41) Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. 727 Catalog 1308242 Issued 3-03 (PDF Rev. 9-07) P&B Outline Dimensions (Continued) Relay Front Diagrams Relays With .250" (6.35mm) Terminals 1-3 Pole Relays 1.531 MAX. (38.89) 4 Pole Relays 1.531 MAX. (38.89) 1 4 2 5 3 6 7 8 9 A 1 4 7 1.406 MAX. (35.71) 2 5 1.531 MAX. (38.89) 3 6 9 11 2 2 3 34 5 6 4 7 8 1.406 MAX. (35.71) B A B 9 10 11 12 A 1.406 MAX. (35.71) B Terminal Dimensions .110" (2.79mm) Quick ConnectQuick Connect .109 (2.77) .205" (5.21mm) Quick Connect .250" (6.35mm) .034 (.86) HEADER .311 REF. (7.90) .280 (7.11) .070 DIA. (1.78) .205 .0 02 (5.21 .05) HEADER .035 (.89) .035 (.89) .093 (2.36) .156 (3.96) .110 (2.79) .035 .285 (.89) (7.24) .316 REF. (8.03) .032 THICKNESS (.81) .032 THICKNESS (.81) .134 (3.40) .312 (7.92) .187" (4.75mm) Quick Connect HEADER .187 .002 (4.75 .05) .250 .078 (6.35) (1.98) .281 REF. (7.14) .020 THICKNESS (.51) .047 (1.19) Note: All drawings shown oversize. .237 .156 (6.02) (3.96) .268 REF. (6.81) .032 THICKNESS (.81) .180 (4.57) HEADER .125 (3.18) .358 REF. (9.09) THICKNESS .032 (0.81) .093 (2.36) .305 (7.75) .156 (3.96) Printed Circuit .250 .0 03 (6.35 .08) HEADER Wiring Diagrams *1 Form X 1 Form C *2 Form A 2 4 - A 6 + - +4 5 7 B A - B 7 A 3 Form C *2 Form C +6 9 - - + B 1 4 7 A - - + 4 Form C 3 3 1 2 3 1 6 4 5 6 5 2 6 7 8 4 9 7 8 9 9 10 11 12 B A B A B *Recommended Load Polarity for Optimum Arc Suppression. PC Board Layouts (Bottom Views) 1 Form X 3 Pole Models .076 DIA. TYP. (1.93) 4 Pole Models .076 DIA. TYP. (1.93) .076 DIA. TYP. (1.93) .206 (5.23) .626 (15.90) .328 (8.33) .328 (8.33) .626 (15.90) .875 (22.23) .437 (11.10) .340 (8.64) .875 (22.23) Dimensions are shown for 728 reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. .206 (5.23) .626 (15.90) .170 (4.32) .510 (12.95) 1.020 (25.91) Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. Catalog 1308242 Issued 3-03 (PDF Rev. 9-07) P&B Sockets For KU Series Relays Through 3 Poles Socket Selection Table Stock items are boldfaced. For KUP, KUEP, KUGP, KUIP, and KUMP relays, through 3 poles, with .187" (4.75mm) quick connect termination. Socket 27E043 27E046 27E067 27E121 27E305 27E396 27E893 Socket Termination Solder eyelet PC board, .144" (3.66mm) terminals .187" (4.75mm) quick connect Screw terminals PC board, .184" (4.67mm) terminals .187" (4.75mm) quick connect* Screw terminals Hold-Down Spring 20C228 or 20C254* 20C228 or 20C254 20C228 or 20C254 20C314 (2 per socket required) 20C228 or 20C254 20C254 20C318 * 20C228 held in place by socket hold-down screw where as 20C254 snaps onto socket. ** Snap-in mounting. DIN rail mounting. Note: All part numbers are RoHS compliant. Hard Mount Sockets For Relays Through 3 Poles 1.687 .010 (42.85 .25) Nylon sockets with .187" (4.75mm) quick connect, solder or printed circuit terminals are available for KUEP, KUGP, KUIP, KUMP, and KUP relays, through 3 poles, with .187" 1.370 (4.75mm) quick connect terminals. All are rated 15 amps and UL recognized, File (34.80) E59244 and CSA certified File LR15734 27E043-with solder eyelet terminals. 27E067-with .187" (4.75mm) quick connect terminals. 1.250 (31.75) 2.03 (51.56) .875 .010 (22.23 .25) 1.50 (38.1) 27E067 27E043 .50 TYP. (12.7) .165 DIA. (4.19) 2 HOLES .297 (7.54) .125 (3.18) .250 (6.35) .34 MAX. (8.64) 1.687 .010 (42.85 .25) .076 DIA. (1.93) 1.370 (34.80) 1.50 (38.1) 2.03 (51.56) 1.687 (42.85) 1.076 (27.33) .023 (.58) .297 (7.54) .180 TYP. (4.57) .156 TYP. (3.96) .328 (8.33) Nylon snap-in socket with .187" (4.75mm) quick connect terminals is available for KUEP, KUGP, KUIP, KUMP, and KUP relays, through 3 poles, with .187" (4.75mm) quick connect terminals. Snap-in sockets reduce labor by eliminating time consuming screw or rivet mounting. Preassembled wiring harnesses may also be used as the sockets are designed to snap into the chassis from either front or back. All are rated 15 amps and UL recognized, File E59244. The 27E396 uses chassis cutout shown on this page. 27E396-with .187" (4.75mm) quick connect terminals. 27E046 HAS TERMINALS .144" (3.66 mm) LONG. 27E305 HAS TERMINALS .184" (4.67 mm) LONG. Recommeded Chassis Cutout For Snap-In Sockets .396 (10.06) 1.395 (35.43) 1.260 (32.0 0) 1.687 (42.85) 1.270 (32.26) .110 (2.79) 4 PLACES .260 (6.60) .437 (11.10) .218 (5.54) .090 TYP. (2.29) Recommended Chassis Cutout For Hard Mount Sockets .875 (22.23) .875 (22.23) .626 (15.90) .875 .010 .125 (22.23 .25) (3.18) .34 MAX. (8.64) 27E396 Snap-In Socket For Relays Through 3 Poles Suggested Socket PC Board Layout .50 TYP. (12.7) 2 HOLES .165 DIA. (4.19) .156 DIA. (3.96) .208 2 HOLES (5.28) Dimensions are shown for reference purposes only. .125 (3.18) .250 (6.35) .297 (7.54) The 27E043 and 27E067 use chassis cutout shown on this page. 1.375 (34.93) 27E046, 27E305 Socket With Printed Circuit Terminals 1.250 (31.75) 1.270 (32.26) .020 (.51) 1.375 (34.93) 1.395 (35.43) .239 (6.07) .065 TYP. (1.65) .281 (7.14) Recommended chassis thickness .031" (.79mm) to .062" (1.57mm). Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. 729 Catalog 1308242 Issued 3-03 (PDF Rev. 9-07) P&B Sockets For KU Series Relays Through 3 Poles (continued) 27E121 27E893 Screw Terminal Socket Screw Terminal, Din Rail Snap-Mount Socket (use with mounting track 24A110) The 27E121 socket offers screw termination for KUEP, KUGP, KUIP, KUL, KUMP and KUP relays, through 3 poles, with .187" (4.75mm) quick connect terminals. This socket stacks on 1.700" (43.18mm) centers. When surface mounting, two #6-32 screws of suitable length are required. When track mounting, two 24A071 retainer clips (not shown) are required. The 27E121 is rated 15 amps and is UL recognized, File E59244, CSA certified, File LR15734. The 27E893 DIN rail, snap-mount socket offers screw termination for KUEP, KUGP, KUIP, KUL, KUMP and KUP relays, through 3 poles, with .187" (4.75mm) quick connect terminals. This socket is constructed with a spring-loaded latch which allows it to be quickly snapped onto or removed from a "top hat" style mounting track. No special tools or extra hardware is required for installation. The 27E893 is UL rated 15 amps, 94V-0, File E59244 and CSA rated 10 amps, File LR15734. Terminal Location .895 MAX. (22.73) 1.700 .010 (43.18 .25) .850 .010 (21.59 .25) Terminal Location .315 MIN. (8.00) Top View 1.500 (38.10) .156 TYP. (3.96) Top View 1.550 (39.37) .540 (13.72) 6 5 4 3 2 1 1.500 (38.10) 6 5 4 3 2 1 3.000 (76.20) .156 TYP. (3.96) 3.150 MAX. (80.01) B 1.450 MAX. (36.83) 1.900 MAX. (48.26) 8 9 .317 TYP. (8.04) A 9 B 1.703 (43.26) 7 A 8 7 1.030 (26.16) .390 (9.91) #6-32 SCREWS & CAPTIVE WASHERS Sockets For KU Series 4 Pole Relays Socket Selection Table Stock items are boldfaced. For 4 pole KUP relays with .110" (2.79mm) quick connect termination. Socket Socket Termianation Hold-Down Spring 27E415 27E419 27E867* .187" (4.75mm) quick connect PC board Screw terminals 20C228 or 20C254 20C228 or 20C254 20C254 * Use 40G432 insulator pad or customer supplied alternative. Note: All part numbers are RoHS compliant. .076 DIA. TYP. (1.93) Note: Only 4 pole KUP relays with .110" (2.79mm) quick Screw Terminal Socket For 4 Pole Relays .206 (5.23) 27E867 offers screw termination for 4 pole KUP relays with .110" (2.79mm) quick connect/socket mount terminals. Rated 10 amps and is UL recognized, File E59244. connect terminals can be used with 4 pole hard mount sockets. .328 (8.33) .50 TYP. (12.7) .165 .0 05 (4.19 .13) 2 HOLES .060 TYP. (1.52) 1.687 (42.85) 1.370 (34.80) 2.03 (51.6) 1.250 (31.75) .340 (8.64) .626 (15.90) .170 (4.32) .510 (12.95) 1.020 (25.91) .125 (3.18) .297 (7.54) .32 MAX. (8.1) W/QC TERMINALS .875 (22.23) 1.50 (38.1) Dimensions are shown for 730 reference purposes only. .250 (6.35) 27E415 uses same chassis cutout as 27E043. .156 DIA. (3.96) (2) MTNG. HOLES 5 1 2 6 3 4 8 + ++ ++ ++ ++ ++ + + ++ .250 .010 #6-32 SCREWS (6.35 .254) .150 MAX. (3.81) 9 A 10 7 11 B 12 2.750 .015 (69.96 .381) 27E415-with .187" (4.75mm) quick connect/solder terminals. 27E419-with printed circuit terminals. See PC board layout at right. Suggested Socket PC Board Layout 2.250 .010 (57.15 .254) Hard Mount Sockets For 4 Pole Relays + 1.750 .010 (44.45 .254) 3.50 .030 (88.9 .762) .230 .030 (5.84 .762) .062 REF. (1.57) .770 MAX. (19.56) .461 MAX. (11.71) W/PC TERMINALS Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover.