LM337
2
Absolute Maximum Ratings
Electrical Characteristics
(VI - VO = 5V, IO = 40mA, 0°C ≤ TJ ≤ +125°C, PDMAX = 20W, unless otherwise specified)
Note:
1. Load and line regulation are specified at constant junction temperature. Change in VO due to heating effects must be taken into
account separately. Pulse testing with low duty is used.
2. CADJ, when used, is connected between the adjustment pin and ground.
Parameter Symbol Value Unit
Input-Output Voltage Differential |VI - VO|40 V
Power Dissipation PDInternally limited W
Operating Temperature Range TOPR 0 ~ +125 °C
Storage Temperature Range TSTG -65 ~ +125 °C
Parameter Symbol Conditions Min. Typ. Max. Unit
Line Regulation (Note1) Rline TA = +25°C
3V ≤ I VI - VO I ≤ 40V -0.010.04
%/ V
3V ≤ I VI - VO I ≤ 40V - 0.02 0.07
Load Regulation (Note1) Rload TA = +25°C
10mA ≤ IO ≤ 0.5A -1550
mV
10mA ≤ IO ≤ 1.5A - 15 150
Adjustable Pin Current IADJ --50100μA
Adjustable Pin Current Change ΔIADJ
TA = +25°C, 10mA ≤ IO ≤ 1.5A
3V ≤I VI - VO I ≤ 40V -25
μA
TA = +25°C -1.213 -1.250 -1.287
Reference Volt ag e VREF 3V ≤ I VI - VO I ≤ 40V
10mA ≤ IO ≤ 1.5A -1.200 -1.250 -1.300 V
Temperature Stability STT0°C ≤ ΤJ ≤ +125°C - 0.6 - %
Minimum Load Current to Maintain
Regulation IL(MIN) 3V ≤I VI - VO I ≤ 40V - 2.5 10 mA
3V ≤I VI - VO I ≤ 10V - 1.5 6
Output Noise eNTA = +25°C 10Hz ≤ f ≤10kHz - 0.003 - V/106
Ripple Rejection Ratio RR VO = -10V, f = 120Hz - 60 - dB
CADJ = 10μF (Note2) 66 77 -
Long Term Stability ST TJ = 125°C ,1000Hours - 0.3 1 %
Thermal Resistance Junction to
Case RθJC --4-°C/W