Signal Reference
Designation
Pin
Number Function Summary
General-purpose
input common +COM 6 Input signal common of the 6 to 9 pins
DC 5V is input.
Alarm clear signal
(standard)
standard)) ALMC 6 Recoverable alarms are cleared.
Internal photo coupler off →on…Alarm clear
General-purpose
input 1 IN1 6
This is a general-purpose input signal that can be
used by program driving.
Internal photo coupler on…General purpose input 1 on
Internal photo coupler off …General purpose input 1 off
Emergency stop
input EMG 6
The emergency stop signal is input.
Internal photo coupler on…No emergency stop
Internal photo coupler of…Emergency stop
Origin signal ORG 6
The origin signal used for the return to origin
operation is input.
Internal photo coupler on…Origin signal on
Internal photo coupler off…Origin signal off
+ direction
overtravel signal +OT 7
An overtravel signal in the + direction is input.
Internal photo coupler on …+ direction overtravel not
arrived
Internal photo coupler off …+ direction overtravel
arrived
General-purpose
input 2 IN2 7
This is a general-purpose input signal that can be
used by program driving.
Internal photo coupler on…General purpose input 2 on
Internal photo coupler off …General purpose input 2 off
Emergency stop
input EMG 7
The emergency stop signal is input.
Internal photo coupler on…No emergency stop
Internal photo coupler off…Emergency stop
Origin signal ORG 7
The origin signal used for the return to origin
operation is input.
Internal photo coupler on…Origin signal on
Internal photo coupler off …Origin signal off
Alarm clear signal ALMC 7 Recoverable alarms are cleared.
Internal photo coupler off →on…Alarm clear
- direction
overtravel signal −OT 8
An overtravel signal in the - direction is input.
Internal photo coupler on …- direction overtravel not
arrived
Internal photo coupler off…- direction overtravel
arrived
General-purpose
input 3 IN3 8
This is a general-purpose input signal that can be
used by program driving.
Internal photo coupler on…General purpose input 3 on
Internal photo coupler off …General purpose input 3 off
Emergency stop
input EMG 8
emergency stop signal is input.
Internal photo coupler on…No emergency stop
Internal photo coupler off…Emergency stop
Origin signal ORG 8
The origin signal used for the return to origin
operation is input.
Internal photo coupler on…Origin signal on
Internal photo coupler off …Origin signal off
Alarm clear signal ALMC 8 Recoverable alarms are cleared.
Internal photo coupler off →on…Alarm clear
Signal Reference
Designation
Pin
Number Function Summary
Emergency stop
signal EMG 9
The emergency stop signal is input.
Internal photo coupler on…No emergency stop
Internal photo coupler off…Emergency stop
General-purpose
input 4c IN4 9
This is a general-purpose input signal that can be
used by program driving.
Internal photo coupler on…General purpose input 4 on
Internal photo coupler off …General purpose input 4 off
Origin signal ORG 9
The origin signal used for the return to origin
operation is input.
Internal photo coupler on…Origin signal on
Internal photo coupler off …Origin signal off
Alarm clear signal ALMC 9 alarms are cleared.
Internal photo coupler off →on…Alarm clear
During motor
operation BUSY 10
The operation status of the motor is output.
Internal photo coupler on…During motor operation
Internal photo coupler off…During motor stop
During program
execution PEND 10
The execution status of the program is output.
Internal photo coupler on…During program execution
Internal photo coupler off…Program execution
complete
Zone signal ZONE 10 on when the current position is inside the
coordinates that were set beforehand.
During program
execution PEND 11
The execution status of the program is output.
Internal photo coupler on…During program execution
Internal photo coupler off…Program execution
complete
During motor
operation BUSY 11
The operation status of the motor is output.
Internal photo coupler on…During motor operation
Internal photo coupler off…During motor stop
Zone signal ZONE 11 Turns on when the current position is inside the
coordinates that were set beforehand.
Alarm output ALM 12
When various alarm circuits operate in the driver, an
external signal is output.
At this time, the stepping motor becomes non excited
status.
Output signal
common OUT_COM 13 It is for the output signal common.
DATA+ DATA+ 14 It is for the serial signal.
DATA −DATA −15 It is for the serial signal.
■SpecificationSummaryofInput/OutputSignals(SerialI/Fmode)
■
SpecificationSummaryofInput/OutputSignals(PulsetrainI/Fmode)
Signal Reference
Designation
Pin
Number Function Summary
CW pulse input
(Standard)CW+
CW −1
2
When “2inputmode
”,
InputdrivepulserotatingCWdirection.
Pulse train input CK+
CK−1
2
When “1inputmode
”,
Inputdrivepulsetrainformotorrotation.
CCW pulse input
(Standard)CCW+
CCW −3
4
When “2inputmode
”,
InputdrivepulserotatingCCWdirection.
Rotational
direction input
U/D+
U/D −3
4
When “1 input mode”,
Input motor rotational direction signal.
Internal photo coupler ON …CW direction
Internal photo coupler OFF …CCW direction
General-purpose
input common +COM 6 Inputsignalcommonofthe6to9pins
DC5V is input.
Power down
input PD 6
InputtingPDsignalwillcutoff
(power off)
the current
flowing to the Motor
(With dip switch select, change to
thePowerlowfunctionispossible
).
PDinputsignalon
(internal photo coupler on)
…PD function is valid.
PDinputsignaloff
(internal photo coupler off)
…PD function is invalid.
Step angle
select input EXT 7
FULL/HALF select input will become valid by inputting
EXT signal.
EXT input signal on
(internal photo coupler on)
…External input signal F/H is valid
EXT input signal off
(internal photo coupler off)
…MainbodyrotaryswitchS.Sisvalid
Signal Reference
Designation
Pin
Number Function Summary
FULL/HALF
select input F/H 8
When EXT input signal on
(internal photo coupler on),
F/H input signal on
(internal photo coupler on)
…HALF step
F/H input signal off
(internal photo coupler off)
…FULL step
Emergency
stop EMG 9
The emergency stop signal is input.
Internal photo coupler on…No emergency stop
Internal photo coupler off…Emergency stop
During motor
operation BUSY 10
The operation status of the motor is output.
Internal photo coupler on
…During motor operation
Internal photo coupler off
…During motor stop
Phase origin
monitor output MON 11
When the excitation phase is at the origin
(in power on)
it
turns on.
When FULL step, ON once for 4 pulses, when HALF step,
ON once for 8 pulses.
Alarm output ALM 12
When alarm circuits actuated inside the Driver, outputs
signals to outside. Then the Stepping motor becomes
unexcited status.
Output signal
common OUT_COM 13 It is for the output signal common.
※As for the Motor rotational direction, CW direction is regard as the clockwise revolution by
viewingtheMotorfromoutputshaftside.