G3CN G3CN
172
Specifications
Ratings
Input
Model Rated
voltage
Operating voltage
Impedance V
oltage level
Must operate
voltage
Must release
voltage
G3CN-202P(1)-US
G3CN-203P(1)-US
4 to 24 VDC 3 to 28 VDC
1.5 k
Ω
+20%/–10% 3 VDC max.
1 VDC min.
G3CN-202PL(1)-US
5 VDC
4 to 6 VDC
390
Ω±20% 4 VDC max.
G3CN-203PL(1)-US 12 VDC
9.6 to 14.4 VDC
900
Ω±20%
9.6 VDC max.
24 VDC
19.2 to 28.8 VDC
2 kΩ±20%
19.2 VDC max.
G3CN-DX02P(1)-US
G3CN-DX03P(1)-US
4 to 24 VDC 3 to 28 VDC
1.5 k
Ω
+20%/–10% 3 VDC max.
Note: The
input impedance is measured at the maximum value of the operating voltage. For example, with the model rated at 4 to 24 VDC, the
input
impedance is measured at 28 VDC.
Output
Model
Applicable load
Rated load voltage Load volage range
Load current
Inrush current
W
ithout heat sink
G3CN-202P(1)-US
G3CN-202PL(1)-US
100 to 240 V
AC
75 to 264 V
AC
0.1 to 2 A
30 A (60 Hz, 1 cycle)
G3CN-203P(1)-US
G3CN-203PL(1)-US
0.1 to 3 A
45 A (60 Hz, 1 cycle)
G3CN-DX02P(1)-US
4 to 48 VDC
3 to 52.8 VDC
0.1 to 2 A
12 A (10 ms)
G3CN-DX03P(1)-US
0.1 to 3 A
18 A (10 ms)
Characteristics
Item G3CN-202P(1)/203P(1)-US G3CN-202PL(1)/203PL(1)-US G3CN-DX02P(1)/03P(1)-US
Operate
time
1/2 of load power source cycle +
1 ms max. 1 ms max.
0.5 ms max.
Release time
1/2 of load power source cycle +
1 ms max.
1/2 of load power source cycle
+ 1 ms max.
2 ms max.
Output ON voltage drop
1.6 V (RMS) max.
1.5 V max.
Leakage current
5 mA max. (at 100 V
AC)
10 mA max. (at 200 V
AC)
2.5 mA max. (at 100 V
AC)
5 mA max. (at 200 V
AC)
5 mA max. (at 50 VDC)
Insulation resistance
100 M
Ω
min. (at 500 VDC)
Dielectric strength
2,500 V
AC, 50/60 Hz for 1 min
V
ibration resistance
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance
Malfunction: 1,000 m/s
2
Ambient temperature
Operating: –30°
C to 80
°
C (with no icing nor condensation)
Storage: –30°
C to 100
°
C (with no icing nor condensation)
Ambient humidity
Operating: 45% to 85%
Approved standards
UL508, UL1
14 File No.E64562, CSA C22.2 (No.0, No.14) File No. LR35535
Weight
Approx. 25 g