Adjustable Range Reective Photoelectric Sensor EQ-500 SERIES
366
Selection
Guide
Amplier
Built-in
Power Supply
Built-in
Amplier-
separated
CX-400
CY-100
EX-10
EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Type Multi-voltage DC-voltage
With timer With timer With timer With timer
Item Model No. EQ-501 EQ-501T EQ-502 EQ-502T EQ-511 EQ-511T EQ-512 EQ-512T
Adjustable range (Note 2,3) 0.2 to 2.5 m 0.656 to 8.202 ft 0.2 to 1.0 m 0.656 to 3.281 ft 0.2 to 2.5 m 0.656 to 8.202 ft 0.2 to 1.0 m 0.656 to 3.281 ft
Sensing range (at max. setting distance) (Note 3)
0.1 to 2.5 m 0.328 to 8.202 ft 0.1 to 1.0 m 0.328 to 3.281 ft 0.1 to 2.5 m 0.328 to 8.202 ft 0.1 to 1.0 m 0.328 to 3.281 ft
Hysteresis (Note 3) 10 % or less of operation distance
Supply voltage 24 to 240 V AC ±10 % or 12 to 240 V DC ±10 %
Ripple P-P 10 % or less 12 to 24 V DC ±10 % Ripple P-P 10 % or less
Power / Current consumption
AC: 4 VA or less
DC: 3 W or less
AC: 5 VA or less
DC: 4 W or less
AC: 4 VA or less
DC: 3 W or less
AC: 5 VA or less
DC: 4 W or less
45 mA or less
Output
Relay contact 1a
• Switching capacity: 2 50 V AC 3 A (resistive load)
30 V DC 3 A (resistive load)
• Electrical life: 100,000 or more switching operations
(switching frequency 1,200 operations/hour)
• Mechanical life: 50 million or more switching operations
(switching frequency 18,000 operations/hour)
NPN open-collector transistor
• Maximum sink current: 100 mA
• Applied voltage: 30 V DC or less (between output and 0 V)
• Residual voltage: 1 V or less (at 100 mA sink current)
0.4 V or less (at 16 mA sink current)
PNP open-collector transistor
• Maximum source current: 100 mA
• Applied voltage: 30 V DC or less (between output and +V)
• Residual voltage: 1 V or less (at 100 mA source current)
0.4 V or less (at 16 mA source current)
Output operation Switchable either Detection-ON or Detection-OFF
Short-circuit protection
–
Incorporated
Response time
20 ms or less (For EQ-50□T depends on the setting timer period)
2 ms or less (For EQ-51□T depends on the setting timer period)
Operation indicator Orange LED (lights up when the output is ON)
Stability indicator Green LED (lights up under stable operating condition)
Distance adjuster 2-turn mechanical adjuster with indicator
Sensing mode
–
Switchable either BGS or FGS function
Timer function
–
Incorporated with
variable
(0.1 to 5 sec.)
ON-delay /
OFF-delay timer
–
Incorporated with
variable
(0.1 to 5 sec.)
ON-delay /
OFF-delay timer
–
Incorporated with
variable
(0.1 to 5 sec.)
ON-delay /
OFF-delay timer
–
Incorporated with
variable
(0.1 to 5 sec.)
ON-delay /
OFF-delay timer
Automatic interference prevention function
Incorporated (Note 4)
Environmental resistance
Protection IP67 (IEC)
Ambient temperature –20 to +55 °C –4 to +131 °F (No dew condensation or icing allowed), Storage: –30 to +70 °C –22 to +158 °F
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Ambient illuminance Incandescent light: 3,000 ℓx at the light-receiving face
Voltage withstandability
2,000 V AC for one min. among supply terminals, non-supply
metal parts and relay contact output terminals, 1,000 V AC for
one min. between relay contacts
1,000 V AC for one min. between all supply terminals
connected together and enclosure
Insulation resistance
100 MΩ, or more, with 500 V DC megger among supply
terminals, non-supply metal parts and relay contact output
terminals as well as between relay contacts
20 MΩ, or more, with 250 V DC megger between all supply
terminals connected together and enclosure
Vibration resistance 10 to 55 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each
Shock resistance 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions for three times each
Emitting element Infrared LED (Peak emission wavelength: 855 nm 0.034 mil, modulated)
Receiving element 2-segment photodiode
Material Enclosure: ABS, Front cover: Polycarbonate, Display cover: Polycarbonate
Connection method Screw-on terminal connection
Cable Suitable for round cable ø9 to ø11 mm ø0.354 to ø0.433 in
Cable length Total length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cabtyre cable.
Weight Net weight: 100 g approx. Net weight: 85 g approx.
Accessory Adjusting screwdriver: 1 pc.
Notes: 1) Where measurement conditions have not been specied precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F.
2) The adjustable range stands for the maximum sensing range which can be set with the distance adjuster. The sensor can also detect an object 0.1 m
0.328 ft, or more, away.
3) The adjustable range, sensing range and hysteresis are specied for white non-glossy paper (200 × 200 mm 7.874 × 7.874 in) as the object.
4) Note that the detection may be unstable depending on the mounting conditions or the sensing object. In the state that this product is mounted, be sure
to check the operation with the actual sensing object. Refer to “Automatic interference function (p.368)” of “PRECAUTIONS FOR PROPER USE” for
details.
SPECIFICATIONS