120-150W, 90-264Vac Input, Open-frame Switching Mode Power Supply
Technical Sales / Customer Service: +1-818-338-7788 • Email: sales@autec.com
31328 Via Colinas Suite 102 Westlake Village, CA 91362 USA www.autec.com
1 / 4
SP150 Series
Features
Single output from 120-150W
Input voltage range: 90-264V
Output current(0-10000mA)
3”x 5” form factor
High variety of output voltages from 12Vdc-56Vdc
Efficiency to 85%
Protections: OVP, SCP, Brown-out, and overload
UL, cUL, CE, FCC, TUV certifications
Applications
Network system, telecommunication system, storage system, industrial equipment, and printers
Model List*(See part number scheme for model number details)
Notes:
1. Load regulation is tested at 10% to 100% of the rated load.
2. Peak-to-peak for 120W, and 150W models, convection rating @115Vac MIN.; Measurements with a
20MHz bandwidth and terminated with a 22uF electrolytic Cap. In parallel with a 0.1uF ceramic Cap.
Model
Number
Input
Voltage
Output
Power
Output
Voltage
Output
Current Min.
Output
Current Max.
Ripple &
Noise
(mVp-p)
Certificates
SP150-1121
90264Vac
120W
12V
0
10A
120
UL/cUL/CB
TUV/CE/FCC
SP150-1151
90264Vac
150W
15V
0
10A
150
-/-/CB
TUV/-/-
SP150-1191
90264Vac
150W
19V
0
7.9A
190
-/-/CB
TUV/-/-
SP150-1241
90264Vac
150W
24V
0
6.25A
240
UL/cUL/CB
TUV/CE/FCC
SP150-1301
90264Vac
150W
30V
0
5A
300
-/-/CB
TUV/-/-
SP150-1481
90264Vac
150W
48V
0
3.2A
480
UL/cUL/CB
TUV/CE/FCC
SP150-1561
90264Vac
150W
56V
0
2.7A
560
UL/cUL/CB
TUV/CE/FCC
*Product images are for illustrative purposes
only and may vary from actual design.
120-150W, 90-264Vac Input, Open-frame Switching Mode Power Supply
Technical Sales / Customer Service: +1-818-338-7788 • Email: sales@autec.com
31328 Via Colinas Suite 102 Westlake Village, CA 91362 USA www.autec.com
2 / 4
SP150 Series
Technical Data
Safety and EMC Approval
Input Voltage
90 264Vac
Frequency
50/60 Hz
Input Current
@115Vac 2.5A rms ; @230Vac 1.5A rms
Inrush Current
Cold Start@ 115Vac, at25 < 40 Ap-p
Cold Start@ 230Vac, at25 < 80 Ap-p
Load Regulation
±5%
Line Regulation
±0.5%
Turn-on Time
<3 Sec (Full Load @115Vac)
Hold-up Time
> 16mSec (Full Load @115Vac)
Safety Ground Leakage
Current
<3.5mA (Class I Type@230Vac 50Hz)
Brown-out Protection
Auto-Recovery
Over Voltage Protection
Latch off (140%±30%)
Over Load Protection
Hiccup/Auto-Recovery
Short circuit protection
Hiccup/Auto-Recovery
Operating Temperature
0-50
Storage Temperature
-40-85
Storage Humidity
5%-95% RH
UL 60950-1
(some models)
cUL 60950-1
(some models)
CB Report(IEC60950-1)
TUV EN 60950-1
CE
(some models)
FCC
(some models)
120-150W, 90-264Vac Input, Open-frame Switching Mode Power Supply
Technical Sales / Customer Service: +1-818-338-7788 • Email: sales@autec.com
31328 Via Colinas Suite 102 Westlake Village, CA 91362 USA www.autec.com
3 / 4
SP150 Series
Mechanical Diagram
Dimensions: 3”x5”x1.17” (W x L x H inch)
Connector Types & PIN Assignments
Connector
Connector Type
PIN Number
Signal
CON 1
(INPUT)
Molex 10-63-4027 or Equivalent parts
Mating Type=Molex 09-50-1031 or Equivalent
PIN 1
PIN 2
PIN 3
NEUTRAL
NC
LINE
CON2
(OUTPUT)
Molex 09-65-268 or Equivalent parts
Mating Type= Molex 09-50-1061 or Equivalent
PIN 4~6
PIN 1~3
V+
RETURN
120-150W, 90-264Vac Input, Open-frame Switching Mode Power Supply
Technical Sales / Customer Service: +1-818-338-7788 • Email: sales@autec.com
31328 Via Colinas Suite 102 Westlake Village, CA 91362 USA www.autec.com
4 / 4
SP150 Series
Part Number Scheme
SP 150-1 XX 1
SP=Open-frame series
1=Single output
150=Output power Watts
XX=Rated Voltage
Ex.) 12=12V
56=56V
*Product images are for illustrative purposes only and may vary from actual design.
*Specifications are subject to change without notice. Autec is not responsible for issues arising from errors
or omissions.
1=Single Input