GBU604G ........ GBU607G 6.0 Amp. Glass Passivated Single Phase In Line GBU Bridge Rectifier Current 6.0 A Voltage 400 V to 1000 V GBU FEATURES UL recognition file number E320541 Ideal for printed circuit board High case dielectric strength of 1500 Vrms High surge current capability Solder dip 260C, 10s Component in accordance to RoHS 2002/95/EC and WEEE 2002/96/EC MECHANICAL DATA Case: GBU. Epoxy meets UL 94V-0 flammability rating. Polatity: As marked on body Mounting Torque: 10cm-kg (8.8 in.- Ibs.) Max. Recommended Torque: 5.5cm-kg (5 in.- Ibs.) Terminals : Matte tin plated leads, solderable per MIL-STD-750 Method 2026, J-STD-002 and JESD22-B102. Consumer grade, meets JESD 201 class 1A whisker test TYPICAL APPLICATIONS Used in ac-to-dc bridge full wave rectification for monitor, TV, printer, switching mode power supply, adapter, audio equipment, and home appliances applications. Maximum Ratings and Electrical Characteristics at 25 C Marking Code GBU 604G GBU 605G GBU 606G GBU 607G GBU604G GBU605G GBU606G GBU607G VRRM Maximum Recurrent Peak Reverse Voltage (V) 400 600 800 1000 VRMS Maximum RMS Voltage (V) 280 420 560 700 VDC Maximum DC Blocking Voltage (V) 400 600 800 1000 IF(AV) Maximum Average Forward Rectified Current @ TC = 90 C 6.0 A 3.0 A @ TA = 25 C IFSM 2 It Cj Tj Tstg Peak Forward Surge Current, 8.3 ms Single Half Sine-wave Superimposed on Rated Load (JEDEC Method) Rating for fusing (t<8.3 ms.) Typical Junction capacitance per leg (Note 3) 175 A 2 Operating Temperature Range 127 A sec 94pF -55 to +150 C Storage Temperature Range -55 to +150 C 211pF Maximum DC Reverse Current Electrical Characteristics at Tamb = 25 C at Rated DC Blocking Voltage VF IR Rth (j-a) Rth (j-c) Maximum Instantaneous Forward Voltage drop per leg @ = 6.0 A @ = 3.0 A Maximum DC Reverse Current @ TA = 25 C at Rated DC Blocking Voltage (Note 1)@ TA =125C Typical Thermal Resistance (Note 2) @ TA = 25 C @ TA =125C 1.1 V 1.0 V 5.0 A 500 A 20 C/W 4.0 C/W Notes: 1. Pulse Test with PW=300 sec, 1% Duty Cycle. 2. Mounted on Al. Plate of 4" x 6" x 0.25" Al-Plate Heat sink. 3. Measured at 1.0MHZ and Applied Reverse Voltage of 4.0 Volts. D.C. www.fagorelectronica.com Document Name: gbu6g Version: Oct-11 Page Number: 1/4 GBU604G ........ GBU607G 6.0 Amp. Glass Passivated Single Phase In Line GBU Bridge Rectifier Ordering information PREFERRED P/N PACKAGE CODE GBU606G TU DELIVERY MODE TU 4.1 3.5 2.16 1.65 3.85 3.56 3.30 3.2x45 CHAMFER 9 TYP. Marking code MC WWY UNIT WEIGHT (g) GBU 22.3 21.8 0.5R (TYP.) 1.9 R 2.54 2.16 18.8 18.3 2.03 1.52 2.16 Year code 1.90 Week code 2.03 1.65 18.0 17.5 1.27 1.02 5.33 4.83 www.fagorelectronica.com Document Name: gbu6g 20 TUBE Package Outline Dimensions: (mm) 7.90 7.40 BASE QUANTITY 0.56 0.46 Version: Oct-11 Page Number: 2/4 GBU604G ........ GBU607G 6.0 Amp. Glass Passivated Single Phase In Line GBU Bridge Rectifier Ratings and Characteristics (Ta 25 C unless otherwise noted) FIG.2- TYPICAL REVERSE CHARACTERISTICS PER BRIDGE ELEMENT FIG.1- MAXIMUM FORWARD CURRENT DERATING CURVE 1000 Heatsink Mounting, TC INSTANTANEOUS REVERSE CURRENT ( A) AVERAGE FORWARD CURRENT. (A) 6.0 4.5 3.0 1.5 P.C.B. Mounting, TA 0 0 25 50 75 100 125 100 TJ = 125 C 10 1 400 V 600 - 1000 V 0.1 0.01 150 TJ = 150 C TJ = 25 C 0 AMBIENT TEMPERATURE. (C) 250 1000 100 TJ = 25 C f = 1.0 MHz Vsig = 50 mVp-p TJ = 150 C 8.3 ms Single Half Sine-Wave JUNCTION CAPACITANCE.(pF) 200 150 100 50 0 80 60 FIG.4- TYPICAL JUNCTION CAPACITANCE FIG.3- MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT PER BRIDGE ELEMENT PEAK FORWARD SURGE CURRENT. (A) 40 20 PERCENT OF RATED PEAK REVERSE VOLTAGE. (%) 100 400 V 600 - 1000 V 10 1 10 100 0.1 1 10 100 REVERSE VOLTAGE. (V) NUMBER OF CYCLES AT 60Hz FIG.5- TYPICAL FORWARD CHARACTERISTICS PER BRIDGE ELEMENT INSTANTANEOUS FORWARD CURRENT. (A) 100 10 1 0.1 0.01 0.4 TJ = 25 C Pulse Width = 300 s 1 % Duty Cycle 0.6 0.8 1.0 1.2 1.4 1.6 INSTANTANEOUS FORWARD VOLTAGE. (V) www.fagorelectronica.com Document Name: gbu6g Version: Oct-11 Page Number: 3/4 GBU604G ........ GBU607G 6.0 Amp. Glass Passivated Single Phase In Line GBU Bridge Rectifier Disclaimer All product, product specifications and data are subject to change without notice to improve reliability, function or design or otherwise. Fagor Electronica, S.Coop., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, "Fagor"), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Fagor makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Fagor disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Fagor's knowledge of typical requirements that are often placed on Fagor products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer's responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer's technical experts. Product specifications do not expand or otherwise modify Fagor's terms and conditions of purchase, including but nos limited to the warranty expressed therein. Except as expressly indicated in writing. Fagor products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Fagor product could result in personal injury or death. Customers using or selling Fagor products not expressly indicated for use in such applications do so at their own risk and agree to fully indemnify and hold Fagor and its distributors harmless from and against any and all claims, liabilities, expenses and damages arising or resulting in connection with such use or sale, including attomeys fees, even if such claim alleges that Fagor or its distributor was negligent regarding the design or manufacture of the part. Please contact authorized Fagor personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Fagor, Product names and markings noted herein may be trademarks of their respective owners. www.fagorelectronica.com Document Name: gbu6g Version: Oct-11 Page Number: 4/4