Pressure Sensors
Low-cost, Stainless Steel, Isolated Sensors 13 mm Series
2 Honeywell • Sensing and Control
PRESSURE SENSOR CHARACTERISTICS (all devices)
Environmental specifications
Compensated temperature range 0 °C to 82 °C [32 °F to 180 °F]
Operating temperature range -40 °C to 125 °C [-40 °F to 257 °F]
Storage temperature range -40 °C to 125 °C [-40 °F to 257 °F]
Vibration 10 G at 20 Hz to 2000 Hz
Shock 100 G for 11 ms
Life 1 million cycles min.
Insulation resistance 100 mΩ at 50 Vdc
Maximum ratings
Voltage version “K” Supply voltage VS = +15 Vdc
Voltage version “L” Supply current IS = +2.0 mA
PERFORMANCE CHARACTERISTICS – COMPENSATED SERIES (1)
Characteristic Minimum Typical Maximum Units
Zero pressure offset -2 0 +2 mV
Pressure non-linearity (3) – ±0.1 ±0.25 %FSS
Pressure hysteresis (3) – ±0.015 ±0.030 %FSS
Repeatability – ±0.010 ±0.030 %FSS
Temp. effect on span (4) – ±0.5 ±1.0 %FSS
Temp. effect on offset (4) – ±0.5 ±1.0 %FSS
Thermal hysteresis (0 °C to 82 °C [32 °F to 180 °F]) – ±0.1 ±0.3 %FSS
Long-term stability of offset and span (5) – ±0.1 ±0.3 %FSS
Response time (6) – 0.1 – ms
Common mode voltage (voltage version “K”) (9) 0.50 1.25 2.0 Vdc
Input resistance (current version “L”) 2.0 4.5 8.0 kΩ
Input resistance (voltage version “K”) 8.0 25 50 kΩ
Output resistance 3.0 4.5 6.0 kΩ
PRESSURE RANGE SPECIFICATIONS – COMPENSATED SERIES
Catalog Listing Pressure range Full scale span (2) Proof pressure
(7) Burst pressure
(8)
13C 0500P (A,S) (1,4,5,6) (K,L) 0 psi to 500 psi 98 mV to 102 mV 1500 psi 2500 psi
13C 1000P (A,S) (1,4,5,6) (K,L) 0 psi to 1000 psi 98 mV to 102 mV 3000 psi 5000 psi
13C 2000P (A,S) (1,4,5,6) (K,L) 0 psi to 2000 psi 98 mV to 102 mV 6000 psi 10,000 psi
13C 3000P (A,S) (1,4,5,6) (K,L) 0 psi to 3000 psi 98 mV to 102 mV 9000 psi 10,000 psi
13C 5000P (A,S) (1,4,5,6) (K,L) 0 psi to 5000 psi 148 mV to 152 mV 10,000 psi 10,000 psi
NOTES
1. Reference conditions (unless otherwise noted): TA = 25 °C [77 °F]; Supply VS = 10 Vdc ±0.01 Vdc or IS = 1.5 mA
±0.0015 mA.
2. Full-scale span (FSS) is the algebraic difference between the output voltage at full-scale pressure and the output at zero
pressure. FSS is ratiometric to supply voltage.
3. Pressure non-linearity is based on best-fit straight line from zero to the full-scale pressure. Pressure hysteresis is the
maximum output difference at any point within the operating pressure range for increasing and decreasing pressure.
4. Maximum error band of the offset voltage or span over the compensated temperature range, relative to the 25 °C [77 °F]
reading.
5. Long-term stability over a six-month period.
6. Response time for a 0 psi to FSS pressure step change, 10 % to 90 % rise time.
7. The maximum pressure that can be applied without changing the transducer’s performance or accuracy.
8. The maximum pressure that can be applied to a transducer without rupture of either the sensing element or transducer
case.
9. Common mode voltage as measure from output to ground.