Pressure Sensors Low-cost, Stainless Steel, Isolated Sensors FEATURES * Rugged, isolated stainless steel package * Reliable semiconductor technology * Calibrated and temperature compensated * Voltage or current supply options * Absolute and sealed gage pressures * Low-cost cell package * Absolute pressure * 0 psi to 500 psi, 1000 psi, 2000 psi, 3000 psi, and 5000 psi TYPICAL APPLICATIONS * Industrial controls * Hydraulic controls * Tank pressure * Pressure transmitters * Process control systems 13 mm Series Honeywell's 13 mm Series stainless steel pressure sensors are designed for high pressure applications that involve measurement of hostile media in harsh environments. This series uses Honeywell's proven piezoresistive semiconductor sensor chip in an oil-isolated housing with or without an integral ceramic for temperature compensation and calibration. This design has proven to be highly reliable, stable and accurate. These sensors feature a weld-ring collar and special back support ring for high cycle life capability as they are designed for further package integration in OEM (Original Equipment Manufacturer) applications. Products are available with pressure ranges from 500 psi through 5000 psi and can be used with voltage or current supplies. EQUIVALENT CIRCUIT 13 mm compensated series 13 mm uncompensated series WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. Sensing and Control WARNING MISUSE OF DOCUMENTATION * The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. * Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Pressure Sensors Low-cost, Stainless Steel, Isolated Sensors 13 mm Series PRESSURE SENSOR CHARACTERISTICS (all devices) Environmental specifications Compensated temperature range Operating temperature range Storage temperature range Vibration Shock Life Insulation resistance Maximum ratings Voltage version "K" Voltage version "L" 0 C to 82 C [32 F to 180 F] -40 C to 125 C [-40 F to 257 F] -40 C to 125 C [-40 F to 257 F] 10 G at 20 Hz to 2000 Hz 100 G for 11 ms 1 million cycles min. 100 m at 50 Vdc Supply voltage VS = +15 Vdc Supply current IS = +2.0 mA PERFORMANCE CHARACTERISTICS - COMPENSATED SERIES Characteristic Zero pressure offset (3) Pressure non-linearity (3) Pressure hysteresis Repeatability (4) Temp. effect on span (4) Temp. effect on offset Thermal hysteresis (0 C to 82 C [32 F to 180 F]) (5) Long-term stability of offset and span (6) Response time (9) Common mode voltage (voltage version "K") Input resistance (current version "L") Input resistance (voltage version "K") Output resistance Minimum -2 - - - - - - - - 0.50 2.0 8.0 3.0 (1) Typical 0 0.1 0.015 0.010 0.5 0.5 0.1 0.1 0.1 1.25 4.5 25 4.5 Maximum +2 0.25 0.030 0.030 1.0 1.0 0.3 0.3 - 2.0 8.0 50 6.0 Units mV %FSS %FSS %FSS %FSS %FSS %FSS %FSS ms Vdc k k k PRESSURE RANGE SPECIFICATIONS - COMPENSATED SERIES Catalog Listing 13C 0500P (A,S) (1,4,5,6) (K,L) 13C 1000P (A,S) (1,4,5,6) (K,L) 13C 2000P (A,S) (1,4,5,6) (K,L) 13C 3000P (A,S) (1,4,5,6) (K,L) 13C 5000P (A,S) (1,4,5,6) (K,L) Pressure range 0 psi to 500 psi 0 psi to 1000 psi 0 psi to 2000 psi 0 psi to 3000 psi 0 psi to 5000 psi Full scale span 98 mV to 102 mV 98 mV to 102 mV 98 mV to 102 mV 98 mV to 102 mV 148 mV to 152 mV (2) Proof pressure 1500 psi 3000 psi 6000 psi 9000 psi 10,000 psi (7) Burst pressure 2500 psi 5000 psi 10,000 psi 10,000 psi 10,000 psi (8) NOTES 1. Reference conditions (unless otherwise noted): TA = 25 C [77 F]; Supply VS = 10 Vdc 0.01 Vdc or IS = 1.5 mA 0.0015 mA. 2. Full-scale span (FSS) is the algebraic difference between the output voltage at full-scale pressure and the output at zero pressure. FSS is ratiometric to supply voltage. 3. Pressure non-linearity is based on best-fit straight line from zero to the full-scale pressure. Pressure hysteresis is the maximum output difference at any point within the operating pressure range for increasing and decreasing pressure. 4. Maximum error band of the offset voltage or span over the compensated temperature range, relative to the 25 C [77 F] reading. 5. Long-term stability over a six-month period. 6. Response time for a 0 psi to FSS pressure step change, 10 % to 90 % rise time. 7. The maximum pressure that can be applied without changing the transducer's performance or accuracy. 8. The maximum pressure that can be applied to a transducer without rupture of either the sensing element or transducer case. 9. Common mode voltage as measure from output to ground. 2 Honeywell * Sensing and Control Pressure Sensors Low-cost, Stainless Steel, Isolated Sensors 13 mm Series PERFORMANCE CHARACTERISTICS - UNCOMPENSATED SERIES (1) Characteristic Zero pressure offset (3) Pressure non-linearity (3) Pressure hysteresis Repeatability (4) Temp. coefficient of span ( 0 C to 82 C [32 F to 180 F]) (4) Temp. coefficient of resistance (0 C to 82 C [32 F to 180 F]) (4) Temp. coefficient of offset (0 C to 82 C [32 F to 180 F]) Thermal hysteresis (0 C to 82 C [32 F to 180 F]) (5) Long-term stability of offset and span (6) Response time Input resistance Output resistance Minimum -7.5 - - - 360 Typical 0 0.1 0.015 0.010 720 Maximum +7.5 0.25 0.030 0.030 1260 Unit mV/V %FSS %FSS %FSS ppm/C 2700 3420 4500 ppm/C - 30 - V/V/C - 0.1 0.3 %FSS - - 4.0 4.0 0.1 0.1 4.75 4.75 0.3 - 6.0 6.0 %FSS ms k k PRESSURE RANGE SPECIFICATIONS - UNCOMPENSATED SERIES Catalog Listing 13U 0500P A 0 K 13U 1000P A 0 K 13U 2000P A 0 K 13U 3000P A 0 K 13U 5000P A 0 K Pressure range 0 psi to 500 psi 0 psi to 1000 psi 0 psi to 2000 psi 0 psi to 3000 psi 0 psi to 5000 psi Full scale span 175 mV to 300 mV 175 mV to 300 mV 175 mV to 300 mV 175 mV to 300 mV 290 mV to 500 mV (2) Proof pressure 1200 psi 3000 psi 6000 psi 9000 psi 10,000 psi (7) Burst pressure 2400 psi 5000 psi 10,000 psi 10,000 psi 10,000 psi (8) NOTES 1. Reference conditions (unless otherwise noted): TA = 25 C [77 F]; Supply VS = 10 Vdc 0.01 Vdc or IS = 1.5 mA 0.0015 mA. 2. Full-scale span (FSS) is the algebraic difference between the output voltage at full-scale pressure and the output at zero pressure. FSS is ratiometric to supply voltage. 3. Pressure non-linearity is based on best-fit straight line from zero to the full-scale pressure. Pressure hysteresis is the maximum output difference at any point within the operating pressure range for increasing and decreasing pressure. 4. The error band resulting from maximum deviation of a transducer's output parameter (offset, span, or resistance) as temperature is varied from 25 C [77 F] to any other temperature within the specified range 0 C to 82 C [32 F to 180 F]. This parameter is not 100 % tested and is guaranteed by process design and tested on a sample basis only. Temperature coefficient of span is evaluated using a constant current source. 5. Long-term stability over a six-month period. 6. Response time for a 0 psi to FSS pressure step change, 10 % to 90 % rise time. 7. The maximum pressure that can be applied without changing the transducer's performance or accuracy. 8. The maximum pressure that can be applied to a transducer without rupture of either the sensing element or transducer case. Honeywell * Sensing and Control 3 Pressure Sensors Low-cost, Stainless Steel, Isolated Sensors 13 mm Series PHYSICAL DIMENSIONS for reference only, in (mm) Package 1 (see note): Ring with back support Note: Non-concentricity effects at the diaphragm weld area may cause runout of up to 0.006 in between the upper and lower portions of the sensor body. (It is recommended to use a counter bore to mate with this device to allow for this nonconcentricity). Package 4: 1/8-27 NPT 4 Honeywell * Sensing and Control Pressure Sensors Low-cost, Stainless Steel, Isolated Sensors 13 mm Series Package 5: 1/4-18 NPT Package 6: 7/16-20 UNF Honeywell * Sensing and Control 5 Pressure Sensors Low-cost, Stainless Steel, Isolated Sensors 13 mm Series Package 0 (see note): Ring and cell Note: Non-concentricity effects at the diaphragm weld area may cause runout of up to 0.006 in between the upper and lower portions of the sensor body. (It is recommended to use a counter bore to mate with this device to allow for this nonconcentricity). 6 Honeywell * Sensing and Control Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors 13 mm Series ORDERING INFORMATION 13 mm Compensated Series For example: Part #13C3000PS4K = 13 mm Cell, Compensated, 3000 psi, Sealed Gauge, 1/8NPT Port with 10 Vdc excitation. 13 mm Uncompensated Series Honeywell * Sensing and Control 7 Pressure Sensors Low-cost, Stainless Steel, Isolated Sensors 13 mm Series WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Contact your local sales office for warranty information. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace without charge those items it finds defective. The foregoing is Buyer's sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. Sensing and Control www.honeywell.com/sensing Honeywell 11 West Spring Street Freeport, Illinois 61032 008131-1-EN IL50 GLO 1004 Printed in USA Copyright 2004 Honeywell International Inc. All Rights Reserved. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. For application assistance, current specifications, or name of the nearest Authorized Distributor, contact a nearby sales office. Or call: 1-800-537-6945 USA/Canada 1-815-235-6847 International FAX 1-815-235-6545 USA INTERNET www.honeywell.com/sensing info.sc@honeywell.com