E3S-5E4S-45
2
Ratings and Specifications
Engineering Data (Typical)
Sensing method Through-beam
Item Model E3S-5E4S-45
Sensing distance Through-beam for paper bags: 200 mm (For standard through-beam use: 10 m)
Standard object Liquid or solid object, Opaque of 11-mm dia. min.
Directional angle Emitter/Receiver: 10 to 30° each
Light source (wavelength) Red LED (890 nm)
Power supply voltage 12 to 24 VDC±10%, ripple (p-p): 10% max.
Current consumption 45 mA max. (Emitter: 25 mA max., Receiver: 20 mA max.)
Control output Load power supply voltage: 24 VDC max., Load current: 80 mA max. (residual voltage: 1 V max.)
NPN voltage output configuration Light-ON/Dark-ON mode selector
Self-diagnosis output Load power supply voltage: 24 VDC max., Load current: 50 mA max. (residual voltage: 1 V max.)
Voltage output type
External-diagnosis input Emission OFF: Short-circuit to 0 V or 1.5 V max. (Outflow current 1 mA max.), Emission ON: Disconnected
(Leakage current 0.1 mA max.)
Protective circuits Power supply reverse polarity protection, Output short-circuit protection
Response time Operate or reset: 10 ms max.
Sensitivity adjustment One-turn adjuster
Ambient illumination
(Receiver side) Incandescent lamp: 3,000 lx max., Sunlight 10,000 lx max.
Ambient temperature range Operating: −10 to 55°C (with no icing and condensation), Storage: 0 to 65°C (with no icing and condensation)
Ambient humidity range Operating: 35% to 85%, Storage: 35% to 95% (with no condensation)
Insulation resistance 20 MΩ min. at 500 VDC
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance Destruction: 500 m/s2 3 times each in X, Y and Z directions
Degree of protection IEC 60529 IP67
Connection method Pre-wired Models (Standard cable length: 2 m)
Weight (packed state) Approx. 300 g
Material
Case Zinc die-cast
Lens Polycarbonate (PC)
Mounting Brackets Iron
Accessories Mounting Bracket (with screws), Screw driver for adjustment, Sensitivity adjuster, Instruction manual
Parallel Operating Range Excess Gain vs. Set Distance
Through-beam Through-beam
4
3
2
1
0
-1
-2
-3
-4
Distance Y (m)
Distance X (m)
5101520
Y
X100
70
50
30
10
7
5
3
1
Excess Gain ratio
Distance X (m)
0 5 10 15 20
Operation
Level