MUR860-TS01
8 Amp S uper Fast
Glass Passivated
R ec tifie r
Features
Maximum Ratings
Operating Junction Temperature: - 55°C to +150°C
Storage Temperature: - 55°C to + 150°C
Microsemi
Catalog
Number
Device
Marking Maximum
Recurrent
Peak
Reverse
Voltage
Maximum
RMS
Voltage
Maximum
DC
Blocking
Voltage
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
Current IF(AV) 8.0A TC = 100°C
Peak Forward Surge
Current IFSM 125A 8.3 ms, half sine
Maximum Forward
Voltage Drop Per
Element
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
IR 10 uA
500uA TJ = 25°C
TJ = 125°C
*Pulse test: Pulse width 300 µsec, Duty cycle 2%
1.50V
www.mccsemi .com
Glass p assiv ated ch ip
Superfast switching time for hight efficiency
L ow reve r se leak ag e c urren t
High surge capacity
Maximum Reverse
Recovery Time
 INCHES MM
     
A .560 .625 14.22 15.88
B .380 .420 9.65 10.67
C .100 .135 2.54 3.43
D .230 .270 5.84 6.86
E .380 .420 9.65 10.67
F ------ .250 ------ 6.35
G .500 .580 12.70 14.73
H .190 .210 4.83 5.33
I .020 .045 0.51 1.14
J .012 .025 0.30 0.64
K .139 .161 3.53 4.09
L .140 .190 3.56 4.83
M .045 .055 1.14 1.40
N .080 .115 2.03 2.92

Trr
A
B
C
K
J
I
G
F
E
D
N
M
L
H
PIN 1
PIN 2 CASE
PIN
12
VF
50ns
IFM = 8 A
TJ = 25°C
IF=0.5A, IR=1.0A,
Irr=0.25A
TO-220AC
600 Volts
MUR860-TS01 MUR860 600V 420V 600V
omponents
21201 Itasca Street Chatsworth

 !"#
$% !"#
MCC
MUR860-TS01
Instantaneous Reverse Leakage Current - MicroAmperes versus
Percent Of Rated Peak Reverse Voltage - Volts
Average Forward Rectified Current - Amperes versus
Case Temperature - °C
Figure 3
Forward Derating Curve
25 50 100 150 175
0
0
2
4
6
Single Phase, Half Wave
60Hz Resistive or Inductive Load
Amps
°C
75
8
10
12
Figure 2
Typical Reverse Characteristics
Volts
.4
.6
2
1
µ
Amps
20 120
40 60 80 100
.001
.002
.00
4
.006
.01
.02
.04
.06
.1
.2
4
6
10
150
TA=25°C
1 100
4
0
25
50
75
8
Figure 4
Maximum Non-Repetitive Forward Surge Current
Peak Forward Surge Current - Amperes versus
Number Of Cycles At 60Hz - Cycles
Amps
Cycles
2
10 20 60 80
40
00
100
125
150
www.mccsemi.com
MCC
Instantaneous Forward Current - Amperes versus
Instantaneous Forward Voltage - Volts
Figure 1
Typical Forward Characteristics
Volts
4
6
20
10
Amps
.2 1.2
.4 .6 .8 1.0
.01
.02
.04
.06
.1
.2
.4
.6
1
225°C
40
60
100
1.4