BATTERY PROTECTION IC FOR 1-CELL PACK
S-8241 Series Rev.9.2_00
Seiko Instruments Inc.
12
3. Detection delay time
(1) S-8241ABA, S-8241ABC, S-8241ABD, S-8241ABE, S-8241ABF, S-8241ABG, S-8241ABH,
S-8241ABI, S-8241ABK, S-8241ABL, S-8241ABQ, S-8241ABT, S-8241ABU, S-8241ABV,
S-8241ABX, S-8241ABZ, S-8241ACA, S-8241ACB, S-8241ACE, S-8241ACF, S-8241ACG,
S-8241ACH, S-8241ACL, S-8241ACO, S-8241ACP, S-8241ACQ, S-8241ACR, S-8241ACS,
S-8241ACT, S-8241ACU, S-8241ACX, S-8241ACY, S-8241ADA, S-8241ADD, S-8241ADH,
S-8241ADL, S-8241ADM, S-8241ADN, S-8241ADO, S-8241ADQ, S-8241ADR, S-8241ADS,
S-8241ADT, S-8241ADV, S-8241ADW, S-8241ADX, S-8241ADY, S-8241ADZ, S-8241AEA,
S-8241AEB, S-8241AEC, S-8241AED, S-8241AEF, S-8241AEI, S-8241AEJ, S-8241AEK,
S-8241AEM, S-8241AEO, S-8241AEP, S-8241AEQ, S-8241AET, S-8241AEW, S-8241AEX,
S-8241AEY, S-8241AFA, S-8241AFB
Table 10
Item Symbol Condition Min. Typ. Max. Unit
Test
Condition
Test
Circuit
DELAY TIME (Ta = 25°C)
Overcharge detection delay time t
CU
⎯
0.7 1.0 1.3 s 8 1
Overdischarge detection delay time t
DL
⎯
87.5 125 162.5 ms 8 1
Overcurrent 1 detection delay time t
lOV1
⎯
5.6 8 10.4 ms 9 1
Overcurrent 2 detection delay time t
lOV2
⎯
1.4 2 2.6 ms 9 1
Load short-circuiting detection delay time t
SHORT
⎯
⎯
10 50
μ
s 9 1
DELAY TIME (Ta =
−
40°C to
+
85°C)
*1
Overcharge detection delay time t
CU
⎯
0.55 1.0 1.7 s 8 1
Overdischarge detection delay time t
DL
⎯
69 125 212 ms 8 1
Overcurrent 1 detection delay time t
IOV1
⎯
4.4 8 14 ms 9 1
Overcurrent 2 detection delay time t
IOV2
⎯
1.1 2 3.4 ms 9 1
Load short-circuiting detection delay time t
SHORT
⎯
⎯
10 73
μ
s 9 1
*1. Since products are not screened at high and low temperature, the specification for this temperature range is guaranteed by
design, not tested in production.
(2) S-8241ABB, S-8241ABO, S-8241ABP, S-8241ABS, S-8241ACI, S-8241ACK, S-8241ACN,
S-8241ACZ, S-8241ADE, S-8241AEH, S-8241AEN, S-8241AER, S-8241AES, S-8241AEU
Table 11
Item Symbol Condition Min. Typ. Max. Unit
Test
Condition
Test
Circuit
DELAY TIME (Ta = 25°C)
Overcharge detection delay time t
CU
⎯
87.5 125 162.5 ms 8 1
Overdischarge detection delay time t
DL
⎯
21 31 41 ms 8 1
Overcurrent 1 detection delay time t
lOV1
⎯
11 16 21 ms 9 1
Overcurrent 2 detection delay time t
lOV2
⎯
1.4 2 2.6 ms 9 1
Load short-circuiting detection delay time t
SHORT
⎯
⎯
10 50
μ
s 9 1
DELAY TIME (Ta =
−
40°C to
+
85°C)
*1
Overcharge detection delay time t
CU
⎯
69 125 212 ms 8 1
Overdischarge detection delay time t
DL
⎯
17 31 53 ms 8 1
Overcurrent 1 detection delay time t
IOV1
⎯
9 16 27 ms 9 1
Overcurrent 2 detection delay time t
IOV2
⎯
1.1 2 3.4 ms 9 1
Load short-circuiting detection delay time t
SHORT
⎯
⎯
10 73
μ
s 9 1
*1. Since products are not screened at high and low temperature, the specification for this temperature range is guaranteed by
design, not tested in production.