SPECIFICATION
MODEL LPV-60-5 LPV-60-12 LPV-60-15 LPV-60-24 LPV-60-36 LPV-60-48
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
OUTPUT
LINEREGULATION
LOADREGULATION
SETUP,RISETIME Note.6
HOLDUP TIME(Typ.)
VOLTAGERANGE Note.4
FREQUENCY RANGE
EFFICIENCY (Typ.)
ACCURRENT (Typ.)
INPUT
INRUSHCURRENT(max.)
LEAKAGECURRENT
SAFETY STANDARDS
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
5V 12V 15V 24V 36V 48V
8A 5A 4A 2.5A 1.67A 1.25A
0~8A 0~5A 0~4A 0~2.5A 0~1.67A 0~1.25A
40W 60W 60W 60W 60W 60W
80mVp-p 120mVp-p 120mVp-p 150mVp-p 150mVp-p 150mVp-p
¡Ó
8.0%
¡Ó
1.0%
¡Ó
6.0%
90~264VAC 127~370VDC
47~63Hz
76% 83%
¡Ó
2.0%
¡Ó
5.0%
83% 86% 86% 86%
5.75~6.75V 13.8~16.2V 17.25~20.25V 27.6~32.4V 41.4~48.6V 55.2~64.8V
1.2A/115VAC1A/230VAC
0.25mA /240VAC
110~150%ratedoutputpower
Protectiontype:Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
CompliancetoEN55022(CISPR22)ClassB, EN61000-3-2Class A,EN61000-3-3
CompliancetoEN61000-4-2,3,4,5,6,8,11,EN55024,lightindustrylevel,criteria A
-30~+70
¢J
(Referto"DeratingCurve")
20~90%RH non-condensing
-40~+80 ,10~95%RH
¢J
¡Ó ¢J ¢J
0.03%/ (0~50 )
10~500Hz,2G10min./1cycle,periodfor 60min.eachalongX, Y,Zaxes
732Khrsmin.MIL-HDBK-217F(25 )
¢J
162.5*42.5*32mm(L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.
8. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minute.
¢J
0.4Kg;32pcs/13.8Kg/0.56CUFT
Protectiontype:Shutdowno/pvoltage,re-powerontorecover
60WSingleOutputSwitchingPowerSupply
¡½
Features :
LPV-60 serie s
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVAC
UL879(exceptforLPV-60-5),UL1310(exceptforLPV-60-5),CSA C22.2No.207-M89(exceptforLPV-60-5,LPV-60-48),
CAN/CSA C22.2No.223-M91(exceptforLPV-60-5,LPV-60-48),IP67approved;designreferto TUVEN60950-1
I/P-O/P:>100MOhms/500VDC/25 /70%RH
¢J
FileName:LPV-60-SPEC 2012-12-26
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
Constant voltage design
Universal AC input / Full range
Withstand 300VAC surge input for 5 seconds
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
Fully encapsulated with IP67 level
Class 2 power unit
ass LPS
Suitable for LED lighting and moving sign applications
100% full load burn-in test
Low cost, high reliability
2 years warranty
¡E
¢º
(Note.8)
Fully isolated plastic case
Class power unit, no FG
P
(Note.7)
500ms,20ms/230VAC5 atfullload ;00ms,20ms/115VAC (for5~36V)500ms,30ms/230VAC500ms,30ms/115VACatfullload(for48V)
50ms/230VAC16ms/115VACatfullload
( for 48V only) ( except for 5V,48V )
EMCIMMUNITY
EMCEMISSION
IP67
LPS
COLDSTART 60A(t =525smeasuredat50%I )at230VACwidth peak
£g