All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
AC/DC Power Supplies
TOP-100 Series 100 Watt
General Specifications
Temperature coefficient 0.02 %/K
Humidity (non condensing) 0 – 95 % rel. H max.
Efficiency – Vin = 115 VAC 89 – 91 %
– Vin = 230 VAC 90 – 92 %
Switching frequency 100 kHz typ. (pulse width modulation)
Hold-up time – Vin = 115 VAC 10 ms typ.
– Vin = 230 VAC 15 ms typ.
Start-up time – Vin = 115 VAC <3.5s
– Vin = 230 VAC <2s
Isolation voltage – Input / Output 3000 VAC
– Input / Field Ground 1500 VAC
– Output / Field Ground 500 VAC
Isolation resistance (at 500 VDC) 100 Mohm min.
Earth leakage current 250 µA max.
Reliability, calculated MTBF at +25°C acc. to IEC 61709 www.tracopower.com/overview/top100
Isolation class class II double isolation
EMC emissions – Conducted input RI suppression EN 55022, class B (conductive plane to be
connected to safety earth)
– Harmonic current emissions IEC / EN 61000-3-2, class A
EMC immunity – Electrostatic discharge ESD IEC / EN 61000-4-2
– RF field immunity IEC / EN 61000-4-3
– Electrical fast transients/burst immunity IEC / EN 61000-4-4
– Surge IEC / EN 61000-4-5
– Conducted RF IEC / EN 61000-4-6
– Voltage dip IEC / EN 61000-4-11
Safety approvals and – CB certificate IEC 60950-1
certifications – SIQ certificate EN 60950-1
– UL coc UL 60950-1
– CSA certificate CSA C22.2 No. 60950-1-03
– Certification documents www.tracopower.com/overview/top100
Environment – Vibration acc. IEC 60068-2-6; 3 axis, sine sweep, 10–55Hz, 1g, 1oct/min
– Shock acc. IEC 60068-2-27 3 axis, 10g half sine, 11msShock
20 G (3 directions each 3 times)
Environmental compliance – Reach www.tracopower.com/info/reach-declaration.pdf
– RoHS RoHS directive 2011/65/EU
Connection pin connector (Molex)
Weight 140 g (4.9 oz)
Installation instructions :