Click on Series name for product info on aimtec.com Series AME3-AZ 3Watt | AC-DC Converter FEATURES: * * * * * * RoHS compliant * Energy Star compliant * Ultra-small package I/O Isolation 3000VAC Operating Temp: -40oCto +80oC Over load, Short Circuit Protection Input: 90-305VAC, 47-440Hz, or 130-430 VDC Optional 90-528VAC, 47-440Hz, or 130-745 VDC Models Single output Input Voltage (VAC/Hz) Input Voltage (VDC) Temperature range (C) Output Voltage (V) Output Current max (mA) Maximum capacitive Load (F) AME3-3.3SAZ AME3-5SAZ AME3-12SAZ AME3-15SAZ AME3-24SAZ 90-305/47-440 90-305/47-440 90-305/47-440 90-305/47-440 90-305/47-440 130-430 130-430 130-430 130-430 130-430 -40 to +80 -40 to +80 -40 to +80 -40 to +80 -40 to +80 3.3 5 12 15 24 900 600 250 200 125 AME3-3.3SBAZ AME3-5SBAZ AME3-12SBAZ AME3-15SBAZ AME3-24SBAZ 90-528/47-440 90-528/47-440 90-528/47-440 90-528/47-440 90-528/47-440 130-745 130-745 130-745 130-745 130-745 -40 to +80 -40 to +80 -40 to +80 -40 to +80 -40 to +80 3.3 5 12 15 24 700 600 250 200 125 Model Efficiency Full load (%) 115 230 277 480 VAC VAC VAC VAC 2200 1100 680 560 470 63 67 75 78 81 64 67 73 74 81 62 65 70 71 80 2200 1100 680 560 470 61 67 72 72 71 61 67 72 71 71 60 66 70 70 69 54 60 61 61 62 Input Specifications Parameters Current (full load) Inrush current <2ms (cold start) Leakage current External fuse Input Dissipation (No Load) Conditions Typical 115 VAC 230 VAC 277 VAC 480VAC 115 VAC 230 VAC 277 VAC 480 VAC Recommended slow blow type Maximum Units 80 40 35 30 10 15 20 30 0.15 mA mA mA mA A A A A mA A W 1 0.3 Output Specifications Parameters Conditions Typical Voltage accuracy* Full load Line regulation LL-HL, Full Load Load regulation* 0-100% load Transient Recovery Time Transient Response Deviation 25% load step Minimum load Ripple & Noise* 20 MHz Bandwidth, 0.1F & 220F E/C in parallel *Measured at 115/230/277/480VAC (Typical input) with Full Load Maximum 5 3 5 200 2 0 200 Units % % % s % of Vout % mV p-p Isolation Specifications Parameters Tested I/O voltage Isolation Resistance www.aimtec.com F 052e R8.O Conditions Typical 60 sec >1000 Tel: +1 514 620 2722 1 of 4 Rated Units 3000 VAC M Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AME3-AZ 3Watt | AC-DC Converter General Specifications Parameters Switching frequency Over Load protection Short circuit protection Operating temperature Conditions Typical Maximum 100 >125% Auto recovery 90-305VAC input models 90-528VAC input models AME3-xxSBAZ derating at 45C AME3-xxSAZ derating at 50C Units KHz Continuous, Auto-recovery Momentary, 3 sec oC -40 to +80 Storage temperature Maximum Case temperature Cooling Humidity Case material Weight Dimensions (L x W x H) oC -40 to +85 100 oC Natural Convection* Non condensing 20~95 % RH Plastic resin + Fiberglass (flammability to UL 94V-0) 25 g 1.40 x 0.92 x 0.76 (35.60 x 23.31 x 19.32mm) > 400 000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load MTBF > 100,000 hrs (MIL-HDBK -217F, t= at highest operating temperature)/Full Load NOTE: All specifications in this datasheet are measured at an ambient temperature of 25C, humidity<75%, typical input voltages 115/230/277/480 VAC and at rated output load unless otherwise specified. * Sufficient air space around is needed. Environment Approval Parameters Shock Conditions Wave form: Half sine wave Acceleration amplitude: 5gn Bump duration: 30 ms Number of bumps: 18 (3 in each direction for every axis) Converter operation before and after test, body mounted (on chassis) Test mode: Sweep sine 10-100Hz, speed 0.05Hz/s Vibrations Displacement: 1mm Acceleration: 3g 3 loops 30min one cycle, 3h total, every axis tested Converter operation before and after test, body mounted (on chassis) Safety Specifications Parameters Agency approvals cULus, CE, CB, FCC Information technology Equipment IEC/EN/UL 60950-1:2006+A11:2009 EMI - Conducted and radiated emission EN55022, class B (* see note) Harmonic Current Emissions IEC/EN 61000-3-2, Class A Voltage fluctuations and flicker IEC/EN 61000-3-3, (EN60555-3) Electrostatic Discharge Immunity IEC 61000-4-2 RF, Electromagnetic Field Immunity IEC 61000-4-3 Standards Electrical Fast Transient/Burst Immunity IEC 61000-4-4 Surge Immunity (1KV) IEC 61000-4-5(SAZ:Level2,SBAZ:Level 1) RF, Conducted Disturbance Immunity IEC 61000-4-6 Power frequency Magnetic Field Immunity IEC 61000-4-8 Voltage dips, Short Interruptions Immunity IEC 61000-4-11 FCC part 15 Subpart B, Class B, ANSI C63.4 :2003 * Note: for 528VAC models to meet the EN55022 class B spec an external 0.33uF X capacitor is needed to be installed between AC L and AC N as close as possible to the input of the power supply itself. www.aimtec.com F 052e R8.O Tel: +1 514 620 2722 2 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AME3-AZ 3Watt | AC-DC Converter Pin Out Specifications* Pin Single 1* 2* 3 4 AC Input (N) or (L1) AC Input (L) or (L2) -V Output +V Output * Note: Input Pins 1 and 2 can be "N" and "L" respectively when the input voltage is supplied from a single phase. Input Pins 1 and 2 can be "L1" and "L2" respectively when the input voltage is supplied from 3 phase line to line voltage 208-480Vac (208 Y/ 120V 3-phase, 240 Y/ 120V 3-phase, 400 Y/ 230V 3-phase or 480 Y/ 277V 3-phase). Derating Free Air Convection 45C AME3-xxSBAZ Output Power % 100 50C AME3-xxSAZ 80 Safe Operating Area 60 40 20 0 -40 -25 0 20 40 45 50 60 80 100 Ambient Temperature C Note: Sufficient air space for natural air flow around must be considered. www.aimtec.com F 052e R8.O Tel: +1 514 620 2722 3 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AME3-AZ 3Watt | AC-DC Converter Dimensions 17.80 (0.70) 35.60 3.80 (0.14) 4.03 (0.15) (1.40) Top Vi ew 1 15.24 1 3 Top View (0.60) 7.60 (0.29) 4 Temp eratu rem easuring point 3 11.655 (0.46) 23.31 4 (0.92) 11.68 (0.45) 2 2 28.00 3.80 (0.14) DIV: 5.00(0.20) (1.10) O 10.0 ( O 0.40) O 0.60 ( O 0.02) 19.32 Side View (0.76) 4.10 (0.16) Dimensions mm (inch) Case Tolerance 0.50 (0.02) Pin Diameter 0.05 (0.002) Pin Pitch Tolerance 0.50 (0.02) 0.60 (0.02) NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec's standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052e R8.O Tel: +1 514 620 2722 4 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only