3Watt | AC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832)
F 052e R8.O 1 of 4 North America only
FEATURES:
Models
Single output
Model
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Temperature
range
(ºC)
Output
Voltage
(V)
Output
Current max
(mA)
Maximum
capacitive
Load
(µF)
115
VAC
230
VAC
277
VAC
480
VAC
AME3-3.3SAZ
90-305/47-440
130-430
-40 to +80
3.3
900
2200
63
64
62
AME3-5SAZ
90-305/47-440
130-430
-40 to +80
5
600
1100
67
67
65
AME3-12SAZ
90-305/47-440
130-430
-40 to +80
12
250
680
75
73
70
AME3-15SAZ
90-305/47-440
130-430
-40 to +80
15
200
560
78
74
71
AME3-24SAZ
90-305/47-440
130-430
-40 to +80
24
125
470
81
81
80
AME3-3.3SBAZ
90-528/47-440
130-745
-40 to +80
3.3
700
2200
61
61
60
54
AME3-5SBAZ
90-528/47-440
130-745
-40 to +80
5
600
1100
67
67
66
60
AME3-12SBAZ
90-528/47-440
130-745
-40 to +80
12
250
680
72
72
70
61
AME3-15SBAZ
90-528/47-440
130-745
-40 to +80
15
200
560
72
71
70
61
AME3-24SBAZ
90-528/47-440
130-745
-40 to +80
24
125
470
71
71
69
62
Input Specifications
Parameters
Conditions
Typical
Maximum
Units
Current (full load)
115 VAC
80
mA
230 VAC
40
mA
277 VAC
35
mA
480VAC
30
mA
Inrush current <2ms (cold start)
115 VAC
10
A
230 VAC
15
A
277 VAC
20
A
480 VAC
30
A
Leakage current
0.15
mA
External fuse
Recommended slow blow type
1
A
Input Dissipation (No Load)
0.3
W
Output Specifications
Parameters
Conditions
Typical
Maximum
Units
Voltage accuracy*
Full load
±5
%
Line regulation
LL-HL, Full Load
±3
%
Load regulation*
0-100% load
±5
%
Transient Recovery Time
200
µs
Transient Response Deviation
25% load step
±2
% of Vout
Minimum load
0
%
Ripple & Noise*
20 MHz Bandwidth, 0.1µF & 220µF E/C in parallel
200
mV p-p
*Measured at 115/230/277/480VAC (Typical input) with Full Load
Isolation Specifications
Parameters
Conditions
Typical
Rated
Units
Tested I/O voltage
60 sec
3000
VAC
Isolation Resistance
>1000
I/O Isolation 3000VAC
RoHS compliant
Operating Temp: -40oCto +80oC
Over load, Short Circuit Protection
Energy Star compliant
Ultra-small package
Input: 90-305VAC, 47-440Hz, or 130-430 VDC
Optional 90-528VAC, 47-440Hz, or 130-745 VDC
Click on Series name for product info on aimtec.com
Series AME3-AZ
3Watt | AC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832)
F 052e R8.O 2 of 4 North America only
General Specifications
Parameters
Conditions
Typical
Maximum
Units
Switching frequency
100
KHz
Over Load protection
Auto recovery
>125%
Short circuit protection
90-305VAC input models
90-528VAC input models
Continuous, Auto-recovery
Momentary, 3 sec
Operating temperature
AME3-xxSBAZ derating at 45°C
AME3-xxSAZ derating at 50°C
-40 to +80
oC
Storage temperature
-40 to +85
oC
Maximum Case temperature
100
oC
Cooling
Natural Convection*
Humidity
Non condensing
20~95
% RH
Case material
Plastic resin + Fiberglass (flammability to UL 94V-0)
Weight
25
g
Dimensions (L x W x H)
1.40 x 0.92 x 0.76 (35.60 x 23.31 x 19.32mm)
MTBF
> 400 000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load
> 100,000 hrs (MIL-HDBK -217F, t= at highest operating temperature)/Full Load
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, typical input voltages
115/230/277/480 VAC and at rated output load unless otherwise specified.
* Sufficient air space around is needed.
Environment Approval
Parameters
Conditions
Shock
Wave form: Half sine wave
Acceleration amplitude: 5gn
Bump duration: 30 ms
Number of bumps: 18 (3 in each direction for every axis)
Converter operation before and after test, body mounted (on chassis)
Vibrations
Test mode: Sweep sine
10-100Hz, speed 0.05Hz/s
Displacement: 1mm
Acceleration: 3g
3 loops 30min one cycle, 3h total, every axis tested
Converter operation before and after test, body mounted (on chassis)
Safety Specifications
Parameters
Agency approvals
cULus, CE, CB, FCC
Standards
Information technology Equipment
IEC/EN/UL 60950-1:2006+A11:2009
EMI - Conducted and radiated emission
EN55022, class B (* see note)
Harmonic Current Emissions
IEC/EN 61000-3-2, Class A
Voltage fluctuations and flicker
IEC/EN 61000-3-3, (EN60555-3)
Electrostatic Discharge Immunity
IEC 61000-4-2
RF, Electromagnetic Field Immunity
IEC 61000-4-3
Electrical Fast Transient/Burst Immunity
IEC 61000-4-4
Surge Immunity (1KV)
IEC 61000-4-5(SAZ:Level2,SBAZ:Level 1)
RF, Conducted Disturbance Immunity
IEC 61000-4-6
Power frequency Magnetic Field Immunity
IEC 61000-4-8
Voltage dips, Short Interruptions Immunity
IEC 61000-4-11
FCC part 15 Subpart B, Class B, ANSI C63.4 :2003
* Note: for 528VAC models to meet the EN55022 class B spec an external 0.33uF X capacitor is needed to be installed between AC L and
AC N as close as possible to the input of the power supply itself.
Series AME3-AZ
3Watt | AC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832)
F 052e R8.O 3 of 4 North America only
Pin Out Specifications*
* Note: Input Pins 1 and 2 can be “N” and "L" respectively when the input voltage is supplied from a single phase.
Input Pins 1 and 2 can be “L1” and "L2" respectively when the input voltage is supplied from 3 phase line to line voltage 208-480Vac (208
Y/ 120V 3-phase, 240 Y/ 120V 3-phase, 400 Y/ 230V 3-phase or 480 Y/ 277V 3-phase).
Derating
Note: Sufficient air space for natural air flow around must be considered.
Pin
Single
1*
AC Input (N) or (L1)
2*
AC Input (L) or (L2)
3
-V Output
4
+V Output
020 60
40 80
100
80
60
40
20
0
Safe Operating Area
Free Air Convection
Ambient Temperature º C
100
-40
Output Power %
-25 50
45°C AME3-xxSBAZ
45
50°C AME3-xxSAZ
Series AME3-AZ
3Watt | AC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832)
F 052e R8.O 4 of 4 North America only
Dimensions
35.60
(1.40)
15.24
(0.60)
28.00
(1.10)
19.32
(0.76)
4.10
(0.16)
Dimensions mm (inch)
Case Tolerance ±0.50 (±0.02)
Pin Diameter ±0.05(±0.002)
Pin Pitch Tolerance ±0.50 (±0.02)
0.60
(0.02)
ew
easuring point
4
2
17.80
(0.70)
1 Top Vi
Temperature m 3 11.655
(0.46)
DIV: 5.00 (0.20)
Ø 10.0 ( Ø 0.40)
Ø 0.60 ( Ø 0.02)
1 3
Top View 4
2
7.60
23.31
(0.92)
(0.29)
Side View
4.03
(0.15)
11.68
(0.45)
3.80
(0.14)
3.80
(0.14)
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.