Series AME3-AZ
3Watt | AC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832)
F 052e R8.O 2 of 4 North America only
General Specifications
90-305VAC input models
90-528VAC input models
Continuous, Auto-recovery
Momentary, 3 sec
AME3-xxSBAZ derating at 45°C
AME3-xxSAZ derating at 50°C
Plastic resin + Fiberglass (flammability to UL 94V-0)
1.40 x 0.92 x 0.76 (35.60 x 23.31 x 19.32mm)
> 400 000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load
> 100,000 hrs (MIL-HDBK -217F, t= at highest operating temperature)/Full Load
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, typical input voltages
115/230/277/480 VAC and at rated output load unless otherwise specified.
* Sufficient air space around is needed.
Environment Approval
Wave form: Half sine wave
Acceleration amplitude: 5gn
Number of bumps: 18 (3 in each direction for every axis)
Converter operation before and after test, body mounted (on chassis)
3 loops 30min one cycle, 3h total, every axis tested
Converter operation before and after test, body mounted (on chassis)
Information technology Equipment
IEC/EN/UL 60950-1:2006+A11:2009
EMI - Conducted and radiated emission
EN55022, class B (* see note)
Harmonic Current Emissions
IEC/EN 61000-3-2, Class A
Voltage fluctuations and flicker
IEC/EN 61000-3-3, (EN60555-3)
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
IEC 61000-4-5(SAZ:Level2,SBAZ:Level 1)
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
FCC part 15 Subpart B, Class B, ANSI C63.4 :2003
* Note: for 528VAC models to meet the EN55022 class B spec an external 0.33uF X capacitor is needed to be installed between AC L and
AC N as close as possible to the input of the power supply itself.