Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Versatile Power Entry Module with Small Footprint P Series UL Recognized CSA Certified VDE Approved PE filtered PS non-filtered PS filtered P Series The P series CHAMELEON power entry module offers the most popular features in a small footprint design As the first 10A module to provide all five power entry functions in one compact design, the chameleon module readily adapts to its environment and the needs of international markets. * Snap-in or flange mounting * Standard IEC 60321-1 C14 power inlet * Both North American and metric fusing capabilities * Two voltage selection options (for 4-voltage selection, see the M, L or LA Series) * Optional DPST on/off switch * Filter options for general purpose, medical and high-performance EMI filtering The CHAMELEON module's compact design and modular construction allows selection of the required power entry feature -- without altering the panel cutout. And the CHAMELEON module, with its optional adapters, will fit several common panel cutouts. Filter Types The CHAMELEON module has four filter and one non-filtered option: S models provide an extended performance two element circuit EMI filter, with attenuation similar to the EEB Series power inlet filter. It offers protection for general purpose applications with stray Line to Ground and Line to Line noise that must be attenuated at the power inlet. These filters have limited leakage current and are available in current ratings of 3, 6 and 10A. L models feature a high performance medical filter designed to help bring most digital equipment (including switching power supplies) into compliance with EN55022, Level B (as well as FCC part 15J, Class B) conducted emissions limits. They are available with current ratings of 6 and 10A. These high performance versions are only available with mounting ears, single voltage selection, in a complete RFI shield with options for switch, fuses and current ratings. Mounting extenders are not compatible with the L or Z models. Z models provide a high performance three element differential mode circuit filter, with extended EMI attenuation similar to the M Series Z models, to help bring most digital equipment (including switching power supplies) into compliance with EN55022, Level B (as well as FCC Part 15J, Class B) conducted emissions limits. They are available with current ratings of 6 and 10A. These high performance versions are only available with mounting ears, single voltage selection, in a complete RFI shield with options for switch, fuses and current ratings. Mounting extenders are not compatible with the L or Z models. For minimum depth behind the panel, see the M Series B models are non-filtered and incorporate an interconnection block. The block connects the voltage selection terminals of an unfiltered CHAMELEON module with an IEC connector and an optional switch to reduce external wiring. Compatible with the A or B RFI shield options. H models provide susceptibility protection with minimal leakage current, and are suitable for patient care and non-patient care medical equipment. 192 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Versatile Power Entry Module with Small Footprint (continued) P Series Ordering Information Part numbers are constructed by selecting the alphanumeric character which represents the desired feature. Note: For any option where shown as "0" use the digit ZERO (0) not the letter (O). Mounting Style Extender Options1 Switch Options* Voltage Select2 Fuse Options Filter Type Filter Current Shield Options1 P S J 0 X S S 6 0 Mounting Style E = Mounting ears (Horizontal axis) S = Snap-in M = Mounting ears Switch Option 0 = Blank S = Double pole single throw (DPST) Fuse Options D = Dual fuse S = Single fuse Filter Current 0 = No filter 3 = 3A 6 = 6A X = 10A 3 (Vertical axis) Input Voltage Select 0 = Single voltage S = Dual voltage2 select (SMPS) X = Dual voltage2 select (series/parallel) Extender for J-Series or others Shield Options Filter Type 0 = No shield 0 = No filter A = Filter shield B = Interconnection B = Complete block3 Shield H = Medical Filter L = High Performance C = Complete can (for L & Z models) Medical4 S = General purpose Z = High Performance4 Power Inlet Filters & Power Entry Modules Extender Option 0 = None C = FN260 J = J Series L = L Series1 Notes: 1 L Series extender cannot be added to units with a shield. No style of extender can be added to units with B or C shields. 2 Dual voltage options are not available with L or Z Filter Types Fuse holder 3 When using the interconnection block, the last 3 digits of the part number are BX (0, A, or B) 4 High performance versions (L or Z filter types) are available with any switch or fuse option but only in 6 or 10A with horizontal (PE) or vertical (PM) mounting ears, single voltage (0), complete shield (C) and no extenders Optional switch * For alternative switch orientation options, please contact technical support or your Corcom product sales representative Optional filter The part number PS0SXSS6B would represent: P Series (P) with a snap-in mount (S) with no extender (0) a switch (S) dual voltage select (X) single fusing (S) general purpose filter (S) for 6A (6) with a B shield (B) 193 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Versatile Power Entry Module with Small Footprint (continued) P Series Voltage Selection Shield Options P series power entry modules include the voltage selector integral with the fuse holder. Three voltage selection options are each supported by one of three different fuse holders. The fifth digit of the part number specifies which of the three fuse holders is included to provide the desired voltage selection. The single voltage fuse holder (option "0") has no voltage indication markings. The dual voltage options select 115V or 230V by removing the fuse holder, flipping it over, and reinstalling it. Voltage selection is indicated through a window in the P Series door. The "SMPS" fuse holder (option "S") jumpers two independent P Series terminals to indicate 230V operation to a switching mode power supply. The "PRSR" parallel/serial fuse holder (option "X") connects the windings of the equipment's dual primary transformer (not included) to step down the voltage or double up the current. The markings on the voltage selection fuse holders also remind the user to install the appropriate fuse for the current at the selected voltage. The P series offers several RF shield options. The metal shield, optional on S, H and B filtered models, provides shielding from radiated emissions and provides an RF ground for the filter to the panel. This shield is available in two versions; a shield of the filter components (designated by an A as the final digit) and a complete shield (designated by B as the final digit). The A shield covers the filter portion of the module and increases performance of the filter by protecting the components from RFI coupling. This shield allows the use of the C or J extender. The B shield covers the entire power entry module with metal, protecting the filter from RFI coupling, and covering the mounting cut-out to block RFI entering or leaving the equipment. The B shield cannot be used with any extender. A complete metal enclosure is integral to both the high performance L and Z models, and must be specified by a C in the part number's final digit. This option is only available with the L or Z models. Input Voltage Selection Schemes S - "SPMS" Jumper Type 115V 230V Power on/off Hot A G Note 1 Note 1 Note 1 Note 1 B Ground Neutral C Power input Sel. Jumpers D H SMPS Provision for single fusing X - "PRSR" Parallel / Serial Type for Dual Primary Transformer 115V 230V Power on/off Hot "A" Shield G Note 1 Note 2 A B 115V "B" Shield Ground Note 1 Neutral C Note 2 H Provision for single fusing 115V D Transformer primary 194 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Versatile Power Entry Module with Small Footprint (continued) P Series Fuseholder Accessories Another feature of the P series power entry module is the versatile fusing arrangement. The fuse holder can hold two 1/4" x 1-1/4" (3AG) or 5 x 20mm (metric) fuses. Single fusing is supported with a conversion clip that shorts one of the two fuse positions, and is designated by an S in the sixth part number digit. A module designated for a single fuse may be reconfigured by the manufacturer or the user to accept two fuses by simply removing the shorting clip. For applications intended for dual fusing, specify a D in the sixth part number digit. GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord PA100: Power interconnect assembly For voltage select models. Designed for use with either filtered or non-filtered units, 6" wire leads Conversion Clip for Single Fuse Applications 3 Power Inlet Filters & Power Entry Modules PA101: Plug only PA102: Pins only for use with PA101 PA105: Same as PA100 but with two wires for units with no voltage selection Interconnection Block Installation of the unfiltered versions of the P series requires wiring of the IEC socket terminals to the optional switch and the switch to the fuse holder. Labor can be eliminated by ordering the module with an interconnection block. This feature, designated by "BX" in the seventh and eighth digits, pre wires the module so that only connection to the equipment must be done during installation. The interconnection block includes a plastic case to prevent access to the internal connections. PA400: J Extender Extends P Series height to fit J panel cutout PA410: L Extender Extends P Series width to fit L panel cutout PA420: C Extender Extends P Series height to fit C panel cutout PA400 Extender for J Series Extender J-Series or others The dimensions of this alternative are the same as the filtered versions. Fuse holder C & L Extenders can not be used with B Shields. L Extender can not be used with shields Optional switch 195 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Optional filter Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Versatile Power Entry Module with Small Footprint (continued) P Series Specifications Maximum leakage current each Line to Ground: H & L Models S & Z Models @ 120 VAC 60 Hz: 2 A .25 mA @ 250 VAC 50 Hz: 5 A .50 mA Hipot rating (one minute): Line to Ground: Line to Line: Electrical Schematics H Model LINE LOAD 2250 VDC 1450 VDC Rated Voltage(max.): 250VAC Operating Voltages: Selectable or Fixed 115/230 VAC S Model LINE Operating Frequency: LOAD 50/60 Hz Rated Current: Non-Filtered - 10A Filtered - 3, 6 or 10A L Model Fuseholder: LINE Accepts one or two fuses .25 x 1.25"(not included) or 5 x 20mm (not included) DPST 10,000 operations at 51A max. inrush Switch: LOAD Z Model LINE LOAD Case Styles Front View PM PE PS High Performance Version Only 2.88 2.39 73.15 60.71 2.496 63.4 1.22 30.98 2.29 58.16 1.58 40.13 1.95 49.53 1.22 30.98 196 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Versatile Power Entry Module with Small Footprint (continued) P Series Case Styles (continued) Extender Options C Extender - FN260 J Extender - J Series 2.51 63.75 2.72 69.08 Bottom edge Bottom edge Standard Models - Side and Rear View Non-Filtered Filtered 3 2.29 58.16 Power Inlet Filters & Power Entry Modules .225 5.715 2.13 54.10 1.93 49.02 High Performance Models - Side and Rear View PM PE 2.39 60.71 2.17 55.12 3.93 99.82 1.12 28.45 1.23 31.24 4.42 112.27 197 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Versatile Power Entry Module with Small Footprint (continued) P Series Case Styles (continued) Shield Options "A" Shield "B" Shield 2.19 55.63 Note: 2.19 55.63 Shields can only be used with filtered models. B shield may not be used with J or C extender Recommended Panel Cutout Cutout PM PE "A" 2.496 63.40 "B" R .06 1.524 1.575 40.00 .135 Note: Mounting Hole Diameter 3.43 For snap-in applications, the "A" sides must have a .020 [.508] radius on the installation side. Dimensions are for front mount applications. Rear mount dimensions should be determined based on customer's application parameters. Snap-in models allow for front mounting only. Not recommended for use in plastic panels. Style Dimension "A" Dimension "B" +.008 - .000 +.008 - .000 No Shield Shielded High Performance Standard High Performance 1.06 [26.92] 1.12 [28.45] 1.12 [28.45] 2.13 [54.10] 2.201 [55.91] PE 1.12 [28.45] 1.12 [28.45] 1.15 [29.21] 2.201 [55.91]* 2.201 [55.91] PS 1.06 [26.92] 1.12 [28.45] - 2.201 [55.91]* - PSC 1.06 [26.92] 1.12 [28.45] - 2.52 [64.01] - PSJ 1.06 [26.92] 1.12 [28.45] - 2.60 [66.04] - PSL 1.12 [28.45] - - 2.201 [55.91]* - PM *For panel thickness of 0.031 - 0.079 [0.787 - 2.01] only. Use 2.213 [56.21] for panel thickness of 0.083 - 0.114 [2.0 - 2.90] 198 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Versatile Power Entry Module with Small Footprint (continued) P Series Performance Data Typical Insertion Loss Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) Measured in closed 50 Ohm system S Models 3A 6A 10A db 100 db 100 db 100 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 0 0.1 1 10 30 Frequency in MHz 0 10 0.1 1 10 30 Frequency in MHz 0 0.1 1 10 30 Frequency in MHz 3 H Models 6A 10A db 100 db 100 db 100 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 0 0.1 1 10 30 Frequency in MHz 0 Power Inlet Filters & Power Entry Modules 3A 10 0.1 1 10 30 Frequency in MHz 0 0.1 1 10 30 Frequency in MHz L Models 6A 10A db 100 db 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 0 10 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 1 10 30 Frequency in MHz 0.1 1 10 30 Frequency in MHz Z Models 6A 10A db 100 db 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 0 10 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 199 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Versatile Power Entry Module with Small Footprint (continued) P Series Minimum Insertion Loss Measured in closed 50 Ohm system Differential Mode / Symmetrical (Line to Line) Common Mode / Asymmetrical (Line to Ground) 200 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com