Design Considerations (continued)
Output Filtering
The Austin MiniLynxTM 12 V SIP module is designed for low
output ripple voltage and will meet the maximum output ripple
specification with 1 µF ceramic and 10 µF tantalum capacitors
at the output of the module. However, additional output filtering
may be required by the system designer for a number of
reasons. First, there may be a need to further reduce the output
ripple and noise of the module. Second, the dynamic response
characteristics may need to be customized to a particular load
step change.
To reduce the output ripple and improve the dynamic response
to a step load change, additional capacitance at the output can
be used. Low ESR polymer and ceramic capacitors are
recommended to improve the dynamic response of the module.
For stable operation of the module, limit the capacitance to less
than the maximum output capacitance as specified in the
electrical specification table.
Safety Considerations
For safety agency approval the power module must be
installed in compliance with the spacing and separation
requirements of the end-use safety agency standards,
i.e., UL ANSI/UL* 62368-1 and CAN/CSA+ C22.2 No.
62368-1 Recognized, DIN VDE 0868-1/A11:2017
(EN62368-1:2014/A11:2017)
For the converter output to be considered meeting the
Requirements of safety extra-low voltage (SELV) or ES1,
the input must meet SELV/ES1 requirements. The power
module has extra-low voltage (ELV) outputs when all
inputs are ELV.
The input to these units is to be provided with a fast-
acting fuse with a maximum rating of 6A in the positive
input lead.