AEV150 Series DC
Contactor Specication
Application
AEV150 series DC contactors are used for battery power supply, DC power control,
circuit protection and other electric vehicle power switch controls. Can also be used in
uninterruptible power supply and other electronic control systems.
Features
HIGH CURRENT AND HIGH VOLTAGE
Nitrogen sealed contacts to minimize arcing.
COMPACT STRUCTURE, LOW NOISE
Contact design yields reduced unit size, low noise while carrying or switching currents.
COIL ECONOMIZER
Built-in coil economizer – only 1.7W holding power @12VDC, limits back EMF to 0V.
HIGH SAFETY
There is no arc leakage due to tight sealing.
HIGH CONTACT RELIABILITY
Stable contact resistance no matter how harsh the environment with sealed contacts.
NO SPECIAL MOUNTING REQUIREMENT
Light weight actuator is less impacted by gravity with no special mounting orientation requirements.
VARIOUS APPLICATIONS
Application includes battery switch and standby equipment, DC power control, circuit protection, etc.
OPTIONAL AUXILIARY CONTACT
Allows for contact position signal.
EU ROHS DIRECTIVE (2011/65/EU) COMPLIANT
Nomenclauture
Series code:
AEV150” = AEV150 Series
Coil Voltage Code:
“M” = 12 - 24 VDC
Options (applied in this order):
Blank = Std. Options (Bottom Mount, Without Aux.
Contact & Polarized Load Terminals)
A” = With Aux. Contact (SPST-NO)
“N” = Non-Polar Load Terminals
Example AEV150 M AN
1
Performance Data
MAIN CONTACT LIFE
Contact arrangement 1 Form X (SPST-NO DM) Resistive load life See chart below
Rated Operating Voltage 12-900VDC Mechanical life 1,000,000 cycles
Continuous (Carry) Current 150A -200A (65 ˚C) AUX. CONTACT
Make/Break current See chart below Aux. Contact arrangement 1 Form A
Max short circuit current 2,000A @320VDC, 1 cycle *1 Aux. Contact Current Max 2A@30VDC/
3A@125VAC
Dielectric Between open Aux. Contact Current Min 100mA@8V
Withstanding Voltage contacts: 2,200Vrms *3
Between contact Aux. Contact Current Max 0.417ohms@30VDC/
and coil: 2,200 Vrms*3 0.150ohms @125VAC
Insulation Resistance*2 Terminal to Terminal/
Terminal to coil
New:Min100MΩ@500Vdc
Endoflife:Min50MΩ@500Vdc
VoltageDrop(@150A) ≤60mV
ENVIRONMENTAL DATA OPERATE / RELEASE TIME
Shock, 11ms ½ sine, operating 20G Peak Close (includes bounce) 25ms, Max.
Vibration, Sine, Peak, 20G 80—2,000Hz Bounce (after close only) 7ms, Max.
Operating
Ambient Temperature -40 to +85 ˚C Release (@2000A includes arc) 12ms, Max.*3
Altitude <4000m
Weight 0.95 Lb (0. 43 kg)
Note:
*1: Does not meet dielectric & IR after test.
*2: Thedetectionpositionisthesameasbreakdownvoltage,endoflifeis50MΩ.
*3: Leakage current<10mA,1min, @sea level.
AEV150 Series DC
Contactor Specication
2
Coil Data
COIL DATA
Voltage (will operate) 9-36VDC
Voltage (Max.) 36VDC
Pickup voltage (Max.) 9VDC
Hold voltage (Min.) 7.5 VDC
Dropout voltage (Min.) 6VDC
Inrush Current (Max.) 3.8A
Holding (Avg.) 0.13A@12VDC / 0.07A@24VDC
Estimated Make & Break Resistive Load Ratings
Electrical Load Life Ratings for Typical EV Applications
MAKE/BREAK LIFE CAPACITIVE & RESISTIVE LOADS AT 320VDC *1 *2
@90% pre-charge (make only), see chart below 50,000 cycles
@Min 80% pre-charge (make only), see chart below 50 cycles
@150A make/break (2 consecutive, reverse polarity)*1 12 cycles
1,500A(break only)
*1 1 cycle
*3
Note:
*1: Resistive load includes L=25uH. Load @2500A, test @200uH
*2: Life based on projected Weibull Life with 95% reliability.
*3: Does not meet dielectric and IR after test.
AEV150 Series DC
Contactor Specication
Note:
1. For resistive loads with 300uH
maximum inductance.
2. End of life when dielectric strength
between terminals falls below
50MΩ@500V.
3. The maximum make current is 650A
to avoid contact welding.
4. Estimates based on extrapolated
data.Usertoconrmperformance
in application.
Estimated
Life (Cycles)
Load Current (A)
3
AEV150 Series DC
Contactor Specication
AEV150 Capacitive Make Test Curves for Pre-Charged Motor Controller
Outline Dimensions: in. (mm)
Current (A)
Time (ms)
4
80% Minimum
Pre Charge
90% Nominal
Pre Charge
1.07±0.01
[26.7±0.3]
Φ0.23±0.01
[Φ5.8±0.3]
Φ2.29±0.02
[Φ58.2±0.6]
0.57±0.01
[14.2±0.3]
15.4±0.4
[390.0±10.0]
Φ2.04±0.02
[Φ52.0±0.6]
Two M8x1.25 Screw Terminal
2 Washers2 Lock Washers, 2 Nuts
Torque: 80-100 lb.in (8.8-11 N.m)
+C Positive
Terminal
Two #10 Mounting Holes
Torque15-30 lb.in1.7-3.3N.m
0.51±0.01
[12.7±0.3]
-C Negative Terminal
2.07±0.01
[51.6±0.3]
2.50±0.02
[62.4±0.6]
2.87±0.02
[71.8±0.6]
1.68±0.01
[41.9±0.3]
3.21±0.02
[80.3±0.6]
2.21±0.02
[55.3±0.6]
2.74±0.02
[68.4±0.6]
C
C
+-
Coil Wires
Red Wire (+)
Black Wire(-)
Optional Aux.
Contact
White Wires
Wire Length
390±10mm
AEV150 Series DC
Contactor Specication
Application Note:
1. Besuretousewashertopreventscrewsfromloosening.Screwtighteningtorquerangeisspeciedasbelow.
Exceeding the maximum torque can lead to product failure.
Contact torque (M8): 80 - 100 lb.in (8.8 - 11 N.m)
Mounting torque: 15 - 30 lb.in (1.7 - 3.3 N.m)
2. Contact Terminals are polarized so refer to drawing during connecting. There is a reverse surge absorption
circuit so that it is not necessary to use a surge protective device.
3. Do not use if dropped.
4. Avoidinstallinginastrongmagneticeld(closetoatransformerormagnet),ornearaheatsource.
5. Electrical life
Use per load capability and life cycle limits so as not to cause a failure. (treat the contactor as a product with
speciedlifeandreplaceitwhennecessary).Itispossibletomakepartsburnaroundthecontactoronce
operating failure occurs. It is necessary to take layout considerations into account and to make sure power shall
be cut off within 1 second.
6. Lifetime of internal gas diffusion
Thecontactorissealedandlledwithgas,lifetimeofgasdiffusionisdeterminedbytemperatureincontact
chamber (ambient temperature + temperature generated by contact operation). Operate only in an ambient
temperature from -40 to +85 ˚C.
7. If inductive load(L/R>1ms) then a surge current protection device should be connected in parallel to the
inductive load.
8. Drive power must be greater than coil power or it will reduce performance capability.
9. Avoid debris or oil contamination of the main terminals to optimize contact and avoid excess heat generation.
10. Unit operates after power applied for 0.1s, do not rapidily switch unit.