General-purpose Relay G2RS-(S) 267
General-purpose Relay
G2RS-(S)
Slim and Space-saving Power Plug-in Relay
Lockable test button models now available.
Built-in mechanical operation indicator.
Provided with nameplate.
AC type is equipped with a coil-disconnection self-
diagnostic function (LED type).
High switching power (1-pole: 10 A).
Environment-friendly (Cd, Pb free).
Wide range of Sockets also available.
RoHS Compliant.
LR
Model Number Structure
Model Number Legend
1. Relay Function
Blank:General-purpose
2. Number of Poles
1: 1 pole
2: 2 poles
3. Contact Form
Blank:SPDT
4. Contact Type
Blank:Single
5. Terminals
S: Plug-in
6. Classification
Blank:General-purpose
N: LED indicator
D: Diode
ND: LED indicator and diode
NI: LED indicator with test button
NDI: LED indicator and diode with test button
7. Rated Coil Voltage
Ordering Information
List of Models
G2R - - - (S)
1234 56 7
Classification Enclosure
rating
Coil ratings Contact form/Model
SPDT DPDT
Plug-in terminal General-purpose Unsealed AC/DC G2R-1-S G2R-2-S
LED indicator G2R-1-SN G2R-2-SN
LED indicator with test button G2R-1-SNI G2R-2-SNI
Diode DC G2R-1-SD G2R-2-SD
LED indicator and diode G2R-1-SND G2R-2-SND
LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI
Rated coil voltage
Note: When ordering, add the rated coil voltage and "(S)" to the model number. Rated coil voltages are given in the coil ratings table.
Example: G2R-1-S DC12 (S) New model
268 General-purpose Relay G2RS-(S)
Accessories (Order Separately)
Connecting Sockets
Note: 1. Use of P2CM Clips are optional. However, use of the P2CM Clip & Release Lever is recommended to ensure stable mounting.
2. “-E” models are of finger-safe product construction. Round terminals cannot be used. Use Y-shaped terminals.
Accessories for Screwless Clamp Terminal Socket (Option)
Mounting Tracks
*Used to mount several P2R-05A and P2R-08A Connecting Sockets side by side.
Specifications
Coil Ratings
* The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of ±10%.
Applicable Relay model Track/surface-mounting Socket Back-mounting Socket
Screwless clamp terminal
(See note.)
Screw terminal Terminals Model
1 pole
G2R-1-S(N)(D)(ND)(NI)(NDI)
P2RF-05-S
+
P2CM-S
P2RF-05-E
P2RF-05
PCB terminals P2R-05P, P2R-057P
Solder terminals P2R-05A
2 poles
G2R-2-S(N)(D)(ND)(NI)(NDI)
P2RF-08-S
+
P2CM-S
P2RF-08-E
P2RF-08
PCB terminals P2R-08P, P2R-087P
Solder terminals P2R-08A
Name Model
Clip & Release Lever P2CM-S
Nameplate R99-11 Nameplate for MY
Socket Bridge P2RM-SR (for AC), P2RM-SB (for DC)
Applicable Socket Description Model
Mounting track and accessories Mounting track 50 cm (l) x 7.3 mm (t)
1 m (l) x 7.3 mm (t)
1 m (l) x 16 mm (t)
PFP-50N
PFP-100N
PFP-100N2
End plate PFP-M
Spacer PFP-S
Mounting plate* Back-connecting Sockets P2R-P
Rated voltage Rated current* Coil
resistance*
Coil inductance (H)
(ref. value)
Must
operate
voltage
Must
release
voltage
Max.
voltage
Power
consumption
(approx.)
50 Hz 60 Hz Armature
OFF
Armature
ON
% of rated voltage
AC 24 V 43.5 mA 37.4 mA 253 Ω0.81 1.55 80% max. 30% min. 110% 0.9 VA at 60 Hz
110 V 9.5 mA 8.2 mA 5,566 Ω13.33 26.83
120 V 8.6 mA 7.5 mA 7,286 Ω16.13 32.46
230 V 4.4 mA 3.8 mA 27,172 Ω72.68 143.90
240 V 3.7 mA 3.2 mA 30,360 Ω90.58 182.34
Rated voltage Rated current* Coil
resistance*
Coil inductance (H)
(ref. value)
Must
operate
voltage
Must
release
voltage
Max.
voltage
Power
consumption
(approx.)
Armature
OFF
Armature
ON
% of rated voltage
DC 6 V 87.0 mA 69 Ω0.25 0.48 70% max. 15% min. 110% 0.53 W
12 V 43.2 mA 278 Ω0.98 2.35
24 V 21.6 mA 1,113 Ω3.60 8.25
48 V 11.4 mA 4,220 Ω15.2 29.82
General-purpose Relay G2RS-(S) 269
Contact Ratings
Note: P level: λ60 = 0.1 x 10-6/operation
Characteristics
Note: Values in the above table are the initial values.
*4,000 VAC, 50/60 Hz for 1 minute when the P2R-05A or P2R-08A Socket is used.
Approved Standards
UL Recognized (File No. E41643) - - Ambient Temp. = 40°C
CSA Certified (File No. LR31928)
IEC/VDE (EN61810)
LR
Number of poles 1 pole 2 poles
Load Resistive load
(cosφ = 1)
Inductive load
(cosφ = 0.4; L/R = 7 ms)
Resistive load
(cosφ = 1)
Inductive load
(cosφ = 0.4; L/R = 7 ms)
Rated load 10 A at 250 VAC;
10 A at 30 VDC
7.5 A at 250 VAC;
5 A at 30 VDC
5 A at 250 VAC;
5 A at 30 VDC
2 A at 250 VAC; 3 A at
30 VDC
Rated carry current 10 A 5 A
Max. switching voltage 440 VAC, 125 VDC 380 VAC, 125 VDC
Max. switching current 10 A 5 A
Max. switching capacity 2,500 VA,
300 W
1,875 VA,
150 W
1,250 VA,
150 W
500 VA,
90 W
Minimum permissible load 100 mA at 5 VDC 10 mA at 5 VDC
Item 1 pole 2 poles
Contact resistance 100 mΩ max.
Operate (set) time 15 ms max.
Release (reset) time AC: 10 ms max.; DC: 5 ms max.
(w/built-in diode: 20 ms max.)
AC: 15 ms max.; DC: 10 ms max.
(w/built-in diode: 20 ms max.)
Max. operating
frequency
Mechanical: 18,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
Insulation resistance 1,000 MΩ min. (at 500 VDC)
Dielectric strength 5,000 VAC, 50/60 Hz for 1 min between coil and
contacts*;
1,000 VAC, 50/60 Hz for 1 min between contacts of
same polarity
5,000 VAC, 50/60 Hz for 1 min between coil and contacts*;
3,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Shock resistance Destruction: 1,000 m/s2
Malfunction: 200 m/s2 when energized; 100 m/s2 when not energized
Service life Mechanical: AC coil: 10,000,000 operations min.;
DC coil: 20,000,000 operations min. (at 18,000 operations/hr)
Electrical: 100,000 operations min. (at 1,800 operations/hr under rated load) (DC coil type)
Ambient temperature Operating: –40°C to 70°C (with no icing or condensation)
Ambient humidity Operating: 5% to 85%
Weight Approx. 21 g
Model Contact
form
Coil ratings Contact ratings Cycles
G2R-1-S SPDT
5 to 110 VDC
5 to 240 VAC
10 A, 30 VDC (resistive)
10 A, 250 VAC (general use)
TV-3 (NO contact only)
6 x 103
G2R-2-S DPDT
5 A, 30 VDC (resistive)
5 A, 250 VAC (general use)
TV-3 (NO contact only)
6 x 103
Model Contact
form
Coil ratings Contact ratings Cycles
G2R-1-S SPDT
5 to 110 VDC
5 to 240 VAC
10 A, 30 VDC (resistive)
10 A, 250 VAC (general use)
TV-3 (NO contact only)
6 x 103
G2R-2-S DPDT
5 A, 30 VDC (resistive)
5 A, 250 VAC (general use)
TV-3 (NO contact only)
6 x 103
Contact
form
Coil ratings Contact ratings Cycles
1 pole
6, 12, 24, 48 VDC
24, 110, 120, 230,
240 VAC
5 A, 440 VAC (cosφ = 1.0)
10 A, 250 VAC (cosφ = 1.0)
10 A, 30 VDC (0 ms)
100 x 103
2 poles
6, 12, 24, 48 VDC
24, 110, 120, 230,
240 VAC
5 A, 250 VAC (cosφ =1.0)
5 A, 30 VDC (0 ms) 100 x 103
Number
of poles
Coil ratings Contact ratings Cycles
1 pole 5 to 110 VDC
5 to 240 VDC
10 A, 250 VAC (general use)
7.5 A, 250 VAC (PF0.4)
10 A, 30 VDC (resistive)
5A, 30VDC (L/R=7ms)
100 x 103
2 poles 5 to 110 VDC
5 to 240 VDC
5 A, 250 VAC (general use)
2 A, 250 VAC (PF0.4)
5 A, 30 VDC (resistive)
3A, 30VDC (L/R=7ms)
100 x 103
270 General-purpose Relay G2RS-(S)
Engineering Data
Maximum Switching Capacity
Plug-in Relays
Electrical Service Life
Plug-in Relays
Ambient Temperature vs. Maximum Coil Voltage
100
10
1
0.1 1 10 100 1000
100
10
1
0.11 10 100 1000
Switching current (A)
Switching voltage (V) Switching voltage (V)
Switching current (A)
AC inductive load
(cosφ = 0.4) AC resistive
load
DC resistive
load
DC inductive load
(L/R = 7 ms)
AC inductive load
(cosφ = 0.4) AC resistive
load
DC resistive
load
DC inductive load
(L/R = 7 ms)
G2R-1-S G2R-2-S
5,000
1,000
500
100
50
5,000
1,000
500
100
50
10,000
Service LIfe (x103 operations)
Switching current (A) Switching current (A)
30-VDC inductive load (L/R = 7ms)
30-VDC inductive load (L/R = 7ms)
Service Life (x103 operations)
250-VAC/30-VDC
resistive load
250-VAC inductive load
(cosφ = 0.4)
250-VAC/30-VDC
resistive load
250-VAC
inductive load
(cosφ = 0.4)
G2R-2-S
G2R-1-S
Ambient temperature (°C)
Note: The maximum voltage refers to the maximum
value in a varying range of operating power
voltage, not a continuous voltage.
Maximum voltage (%)
DC coil
AC coil
General-purpose Relay G2RS-(S) 271
Dimensions
Unit: mm (inch)
Relays with Plug-in Terminals
SPDT Relays
DPDT Relays
Terminal Arrangement/Internal Connections
(Bottom View)
1
234
5
DC24V
20
(0.79)
1(0.04)
0.5 4.75
(0.19)
7.5 (0.29)
17.5
(0.69)
5.2
(0.20)
5.2
(0.20)
35.5 max.
(1.40)
29 (1.14) max. 13 max.
(0.51)
5 (0.20)
G2R-1-SND, G2R-1-SNDI (DC)
G2R-1-S G2R-1-SD (DC)
G2R-1-SN, G2R-1-SNI (AC) G2R-1-SN, G2R-1-SNI (DC)
1
23
4
524
5
1
3
24
5
1
3
1
23
4
5
G2R-1-S, G2R-1-SN, G2R-1-SNI
G2R-1-SD, G2R-1-SND, G2R-1-SNDI
(0.02)
272 General-purpose Relay G2RS-(S)
Track/Surface Mounting Sockets
Accessories for P2RF-@-S
Socket Bridge Clip and Release Lever
32.6 (1.28)
27.6 (1.09)
22.6
(0.89)
24.5
(0.96)
35.4
(1.39)
28.5 (1.12)
32.6
(1.28)
5.3
(0.21)
typical
92.0 max.
(3.62)
18.0 max.
(0.71)
38.2 max. (1.50)
36.5 max. (1.44)
Standard model Option (with ejector and
label attached)
P2RF-05-S Terminal Arrangement
(Top View)
11
14
12
A1 A2
32.6 (1.28)
27.6 (1.09)
22.6
(0.89)
24.5
(0.96)
35.4
(1.39)
3.4 (0.13) typical
28.6 (1.12)
32.6 (1.28)
5.3 typical
(0.21)
92.0 max.
(3.62)
18.0 max.
(0.71)
38.2 max. (1.50)
36.5 max.(1.44)
Standard model Option (with ejector
and label attached)
P2RF-08-S Terminal Arrangement
(Top View)
11
14
12
A1 A2
21
24
22
16.8
(0.66) 40.35
(1.59)
36
(1.42)
Note: The color of insulating coating indicates power type.
Model Power Color
P2RM-SR
P2RM-SB
AC
DC
Red
Blue
General-purpose Relay G2RS-(S) 273
39.5±0.1
(1.55±0.004)
P2RF-05
P2RF-08
7(0.28)
4
(0.16)
2 (0.08)
19.5 (0.77)
7 (0.28)
4 (0.16)
2 (0.08)
19.5 (0.77)
P2RF-05-E
11.5
(0.45)
(11)
(12)
(14)
(A1)
(A2)
1
2
3
4
5
39.5±0.1
(1.55 ±0.004)
2 (0.08)
1.5
(0.06)
5 (0.20)
2 (0.08)
3 (0.12)
39.5
(1.55)
11.5 (0.45)
P2RF-08-E
8
63
72
54
(A1)
(A2)
(21)
(22)
(24)
(11)
(12)
(14)
1
2 (0.08)
5
(0.20)
39.5
(1.55)
35.5
(1.40)
35.5
(1.40)
35.5
(1.40)
30±0.05
(1.18±0.002)
35.5
(1.40)
30±0.05
(1.18±0.002)
3.2 (0.13)
dia. hole
P2RF-05
P2RF-08
Five, M3.5 x 8
19.5 max.
(0.77)
4 (0.16)
dia. holes
30 max.(1.18)
54 max.
(2.12)
4.2 (0.16)
dia. hole
19.5 max.
(0.77)
Eight, M3.5 x 8
4 (0.16)
dia. holes
30 max.(1.18)
54 max.
(2.12)
4.2 (0.16) dia. hole
P2RF-05-E
3.2 (0.13)
dia. hole
Five, M3.5×7
85.5 max.
(3.37)
16.0 max.
(0.63)
Note: Pin numbers in parentheses apply to DIN standard.
61 max.
(2.40)
Eight, M3×8
3.5 (0.14)
dia. hole
16.0 (0.63) max.
P2RF-08-E
Terminal Arrangement
(Top View)
Mounting Holes
(for Surface Mounting)
Terminal Arrangement
(Top View)
Mounting Holes
(for Surface Mounting)
M3 or 3.2 (0.13)
dia. hole
M3 or 3.2 (0.13)
dia. hole
Terminal Arrangement
(Top View)
Mounting Holes
(for Surface Mounting)
Terminal Arrangement
(Top View)
Mounting Holes
(for Surface Mounting)
85.5 max
(3.37)
3.5 (0.14)
dia. hole
48 max.
(1.89)
M3 or 3.5
(0.14) dia.
48.0 max.
(1.89)
61.0 max.
(2.40)
M3 or 3.5 (0.14)
dia. hole
71.5 max.
(2.81)
71.5 max.
(2.89)
274 General-purpose Relay G2RS-(S)
Mounting Height of Relay with Track/Surface Mounting Sockets
Back-connecting Sockets
P2RF-@P2RF-@-E
67.0
(2.64) 70.5
(2.77)
66.5
(2.62)
62.0
(2.44)
28.6
(1.12)
65.0
(2.56)
5.30 (0.21) typical
P2RF-@-S
72.0
(2.83)
1(0.04)
4 (0.16) 7 (0.27)
6 (0.24)
4.5 (0.18)
4 (0.16)
3.5
(0.14)
1.2 (0.05)
1.5 (0.06)
7 (0.27) 4 (0.16)
4 (0.14)
6 (0.24)
4.5 (0.18)
15 (0.59)
4 (0.16)
7 (2.27)
4 (0.16) 7 (0.27)
0.3
(0.01)
5 (0.20)
1 (0.04)
2.8 (0.11)
1.5 (0.06)
7.5 (0.29)
7.5
(0.29)
5 (0.20)
5 (0.20)
4.3 (0.17) typical
5 (0.20) typical
15
(0.59)
Five, 1.6 (0.06)
dia. holes
5 (0.20)
20
(0.79)
20
(0.79)
P2R-05P (1-pole)
14.5 max.
(0.57) Tolerance: ±0.1
Mounting Holes
P2R-08P (2-pole)
Terminal plate thickness: 0.3 (0.01)
14.5 max.
(0.57)
Eight, 1.3 (0.05)
dia. holes
Terminal Arrangement
(Bottom View)
Mounting HolesTerminal Arrangement
(Bottom View)
36.5 max.
(1.44)
35.5 max.
(1.40)
36.5 max. (1.44)
35.5 max.
(1.40)
General-purpose Relay G2RS-(S) 275
7 (0.28)
5 (0.20)
1.2 (0.05)
0.3
(0.01)
6.7 (0.26)
5 (0.20)
6 (0.24)
7 (0.28)
1.2 (0.05)
0.3
(0.01)
5 (0.20)
7 (0.28)
5 (0.20)
2.8(0.11)
2.6 (0.10)
7.5
(0.30)
13.6±0.1
(0.54±0.004)
1.5 (0.06)
3.8 (0.15)
16.7
(0.66)
30.5±0.2
(1.20±0.008)
20
(0.79)
P2R-05A (1-pole)
Panel Cutout
P2R-08A (2-pole)
Five, 3 x 1.8-dia. holes
(0.12 x 0.07)
Terminal plate thickness: 0.3
14.5 max.
(0.57)
Terminal plate thickness: 0.3
14.5 max.
(0.57)
Terminal Arrangement
(Bottom View)
Recommended thickness of
the panel is 1.6 to 2.0 mm
36.5 max.
(1.44)
35.5 max.
(1.40)
35.5 max.
(1.40)
Eight, 3 x 1.2
(0.12 x 0.05)dia. holes
36.5 max.
(1.44)
P2R-057P
P2R-087P
4.5±0.1
(0.18±0.004)
15±0.1(0.59±0.004)
4±0.1 (0.16±0.004)
5 (0.20)
4±0.1
(0.16±0.004)
6±0.1(0.24±0.004)
7±0.1(0.27±0.004)
7.5
(0.30)
5 (0.20)
5 (0.20)
8.1(0.32) typical
0.7 (0.03)
8.9 (0.35)
8.7
(0.34)
8.7
(0.34)
16.4 (0.65)
10.4
(0.41)
1(0.04)
7.4 (0.29)
7.5 (0.30)
16.4(0.65)
1 (0.04)
10.4
(0.41)
7.4 (0.29)
29.6
(1.17)
29.1
(1.15)
20
(0.79)
14 max. (0.55)
14 max.
(0.55)
Mounting HolesTerminal Arrangement
(Bottom View)
Mounting HolesTerminal Arrangement
(Bottom View)
37 max.
(1.46)
41 max.
(1.61)
Five, 1.6 (0.06)
dia. holes
37 max.
(1.46)
41 max.
(1.61)
Eight, 1.3 (0.05)
dia. holes
276 General-purpose Relay G2RS-(S)
Mounting Height of Relay with Back-connecting Sockets
Mounting Tracks
End Plate Spacer
Precautions
!CAUTION
Do not use the test button for any purpose other than testing. Be
sure not to touch the test button accidentally as this will turn the
contacts ON. Before using the test button, confirm that circuits, the
load, and any other connected item will operate safely.
!CAUTION
Check that the test button is released before turning ON relay cir-
cuits.
!CAUTION
If the test button is pulled out too forcefully, it may bypass the mo-
mentary testing position and go straight into the locked position.
!CAUTION
Use an insulated tool when you operate the test button.
Precautions for P2RF-@-S Connection
Do not move the screwdriver up, down, or from side to side while it
is inserted in the hole. Doing so may cause damage to internal
components (e.g., deformation of the clamp spring or cracks in the
housing) or cause deterioration of insulation.
Do not insert the screwdriver at an angle. Doing so may break the
side of the socket and result in a short-circuit.
G2R-@7P
44.5
(1.75)
38.0
(1.50)
G2R Relay G2R Relay
P2R-_P
Socket
P2R-_A
Socket
G2R-@P G2R-@A
47.5
(1.87)
PFP-100N, PFP-50N PFP-100N2
4.5
(0.18)
15 (0.59) 25 25 (0.98) 25 25
10
10 (0.39)
1,000 (39.37)
or 500 (19.68)
7.3±0.15
(0.29±0.006)
35±0.3 27±0.15
1
4.5 (0.18)
15 (0.59)
25
25 (0.98)
25 25 15
10
10 (0.39)
1,000
(39.37)
35±0.3
(1.38±0.01)
27
(1.06)
24
(0.94)
16 (0.63)
1 (0.04) 1.5 (0.06)
15(0.59)
or 5 (0.20)
29.2
(1.15)
It is recommended to use a panel 1.6 to 2.0 mm thick.
PFP-M PFP-S
11.5
(0.45)
10 (0.39)
6.2 (0.24)
1.8 (0.07)
1 (0.04)
1.8
(0.07)
1.3 (0.05)
4.8 (0.19)
5 (0.20)
16 (0.63)
12 (0.47)
10 (0.39)
16.5 (0.65)
50
(1.97)
35.3
(1.39)
35.5
(1.40) 44.3
(1.74)
34.8
(1.37)
M4 x 8 pan
head screw
General-purpose Relay G2RS-(S)
MEMO
General-purpose Relay G2RS-(S)
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.components.omron.com
Cat. No. X301-E-1b Printed in USA
OMRON ELECTRONIC
COMPONENTS LLC
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
09/11 Specifications subject to change without notice
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.