New Product Power Relays MK-S(X) MK-S-series Relays with DC-switching Models That Can Switch 220 VDC, 10 A (Resistive Load). * Switch a DC load of 220 VDC, 10 A (resistive load). * Models for AC Loads can switch 250 VAC, 15 A (resistive load). * Lineup includes models with SPST-NO and SPST-NO/SPSTNC contact forms. * Using a SPST-NO/SPST-NC contact form enables detecting contact welding. (When the NO contacts become welded, the NC contacts will maintain a minimum distance of 0.5 mm.) * Models available with operation indicators and built-in test buttons. * RoHS compliant. * Standards: UL, IEC (TUV certification) For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Ordering Information When your order, specify the rated voltage. General-purpose Relays Models for DC Loads Contact form SPST-NO Type Model Standard Models MKS1XT-10 Models with Built-in Operation Indicators MKS1XTN-10 Models with Test Button MKS1XTI-10 Models with Test Button and Built-in Operation Indicators MKS1XTIN-10 SPST-NO/SPST-NC Rated voltage (V) Model AC: 24, 100, 110, 120, 200, 220, 230, 240 DC: 12, 24, 48, 110, 220 AC: 24, 100, 110, 120, 200, 220, 230, 240 DC: 12, 24, 48, 110, 220 AC: 24, 100, 110, 120, 200, 220, 230, 240 DC: 12, 24, 48, 110, 220 AC: 24, 100, 110, 120, 200, 220, 230, 240 DC: 12, 24, 48, 110, 220 MKS2XT-11 MKS2XTN-11 MKS2XTI-11 MKS2XTIN-11 Rated voltage (V) AC: 24, 100, 110, 120, 200, 220, 230, 240 DC: 12, 24, 48, 110, 220 AC: 24, 100, 110, 120, 200, 220, 230, 240 DC: 12, 24, 48, 110, 220 AC: 24, 100, 110, 120, 200, 220, 230, 240 DC: 12, 24, 48, 110, 220 AC: 24, 100, 110, 120, 200, 220, 230, 240 DC: 12, 24, 48, 110, 220 Models for AC Loads Contact form SPST-NO Type Model Standard Models MKS1T-10 Models with Built-in Operation Indicators MKS1TN-10 Models with Test Button Models with Test Button and Built-in Operation Indicators MKS1TI-10 MKS1TIN-10 SPST-NO/SPST-NC Rated voltage (V) Model AC: 24, 100, 110, 120, 200, 220, 230, 240 DC: 12, 24, 48, 110, 220 AC: 24, 100, 110, 120, 200, 220, 230, 240 DC: 12, 24, 48, 110, 220 AC: 24, 100, 110, 120, 200, 220, 230, 240 DC: 12, 24, 48, 110, 220 AC: 24, 100, 110, 120, 200, 220, 230, 240 DC: 12, 24, 48, 110, 220 MKS2T-11 MKS2TN-11 MKS2TI-11 MKS2TIN-11 Rated voltage (V) AC: 24, 100, 110, 120, 200, 220, 230, 240 DC: 12, 24, 48, 110, 220 AC: 24, 100, 110, 120, 200, 220, 230, 240 DC: 12, 24, 48, 110, 220 AC: 24, 100, 110, 120, 200, 220, 230, 240 DC: 12, 24, 48, 110, 220 AC: 24, 100, 110, 120, 200, 220, 230, 240 DC: 12, 24, 48, 110, 220 Accessory (Order Separately) Connecting Socket Built-in diode Model Back-connecting Socket Classifications PCB Terminals No P7M-06P Front-connecting Socket Mounts to DIN Track or via screws No P7MF-06 Yes P7MF-06-D 1 MK-S(X) Specifications Ratings Operating Coil Item Rated voltage (V) 24 AC 50 Hz 60 Hz 110 96.3 Coil resistance () 26.6 23.1 110 24.2 21.0 932 120 22.2 19.3 1,130 200 13.3 11.6 3,160 220 12.1 10.5 3,550 230 11.5 10.0 4,250 240 11.0 9.6 4,480 24 126 63.2 Must operate voltage (V) Must release voltage (V) Maximum voltage allowable (V) Percentage of rated voltage Power consumption (VA, W) 48.4 100 12 DC Rated current (mA) 760 30% min. at 60 Hz 25% min. at 50 Hz 80% max. Approx. 2.3 VA at 60 Hz Approx. 2.7 VA at 50 Hz 110% 95 380 48 32.0 1,500 110 13.6 8,060 220 6.8 32,200 15% min. Approx. 1.5 W Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C with tolerances of +15%/-20% for AC rated current and 15% for DC coil resistance. 2. Performance characteristic data are measured at a coil temperature of 23C. 3. The maximum allowable voltage is the maximum value of the allowable voltage range for the operating power supply for the relay coil. There is no continuous allowance. 4. The rated current is approximately 5 mA higher for Models with Built-in Operation Indicators (DC operating coils). 2 MK-S(X) Contact Ratings for Models for DC Loads Contact form Model Load Item Contact configuration Resistive load NO SPST-NO SPST-NO/SPST-NC MKS1XT(I)(N)-10 MKS2XT(I)(N)-11 Inductive load L/R = 7 ms DC13 class Resistive load Double-break Double-break --- Single-break NC AgSnIn Contact material NO Rated load Rated carry current Max. switching voltage Max. switching current Max. switching capacity (reference value) 10 A, 220 VDC Inductive load L/R = 7 ms 5 A, 220 VDC AgSnIn 0.4 A, 220 VDC 5 A, 220 VDC 3 A, 220 VDC 0.2 A, 220 VDC 2 A, 220 VDC 0.3 A, 220 VDC 0.1 A, 220 VDC NC --- NO 10 A 5A NC --- 2A NO 220 VDC NC --- NO 10 A 5A NO 220 VDC 0.4 A --- NC 2,200 W ----- NC DC13 class --- 5A 3A 0.2 A 2A 0.3 A 0.1 A 1,100 W --- --- 440 W --- --- Note: If the L/R of an inductive load exceeds 7 ms with a Model for a DC Load, the arc interruption time must be less than approximately 50 ms to use the Relay. Design the circuit so that the arc interruption time is 50 ms or less. * These values apply to a switching frequency of 30 times per minute. Contact Ratings for Models for AC Loads Contact form SPST-NO SPST-NO/SPST-NC MKS1T(I)(N)-10 MKS2T(I)(N)-11 Resistive load Resistive load NO Double-break Double-break NC --- Single-break Model Load Item Contact configuration AgSnIn AgSnIn 15 A, 250 VAC 15 A, 250 VAC NC --- 5 A, 250 VAC NO 15 A 15 A NC --- 5A NO 250 VAC NC --- NO 15 A NC --- 5A NO 3,750 VA 3,750 VA NC --- 1,250 VA Contact material Rated load Rated carry current Max. switching voltage Max. switching current Max. switching capacity (reference value) NO 250 VAC 15 A * These values apply to a switching frequency of 20 times per minute. 3 MK-S(X) Characteristics Contact resistance *1 100 m max. Operate time *2 AC: 20 ms max. DC: 30 ms max. Release time *2 Max. operating frequency 20 ms max. Mechanical 18,000 operations/h Rated load Models for DC loads: 1,800 times/hour Models for AC loads: 1,200 times/hour Insulation resistance *3 100 M min. 2,500 VAC 50/60 Hz for 1 min between Between coil and contacts Dielectric strength Between contacts of different polarity 2,500 VAC 50/60 Hz for 1 min between Between contacts of same polarity 1,000 VAC 50/60 Hz for 1 min Vibration resistance Destruction 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Malfunction 10 to 55 to 10 Hz, 0.50-mm single amplitude (1.0-mm double amplitude) Shock resistance Destruction Back-connecting Socket (P7M-06P) mounting: 1,000 m/s2 Front-connecting Socket (P7MF-06(-D)) mounting:500m/s2 Malfunction 100 m/s2 Endurance Mechanical 1,000,000 operations min. (at 18,000 operations/hr) Electrical *4 100,000 operations min. (at rated load and maximum switching frequency) Failure rate P level (reference value) 10 mA at 24 VDC Ambient operating temperature -40C to 60C (with no icing or condensation) Note: The range is -25C to 60C for models with built-in operation indicators. Ambient operating humidity 5% to 85% Weight SPST-NO: Approx. 73 g, SPST-NO/SPST-NC: Approx. 82 g Note: The values given above are initial values. *1. The contact resistance was measured for 1 A at 5 VDC using the voltage drop method. *2. The operate time was measured with the rated voltage imposed and any contact bounce ignored at an ambient temperature of 23C. *3. The insulation resistance was measured with a 500-VDC insulation resistance tester at the same places as those used for checking the dielectric strength. *4. The electrical endurance was measured at an ambient temperature of 23C. Approved Standards UL508 (File No. E41515) * Model Coil ratings MKS1XT@-@ MKS2XT@-@ 12 to 220 VDC 24 to 240 VAC MKS1T@-@ MKS2T@-@ Contact ratings NO contacts 10 A, 220 VDC (Resistive) 5 A, 220 VDC L/R (T0.632) = 7 ms 0.4 A, 220 VDC L/R (T0.95) = 300 ms NO contacts 5 A, 220 VDC (Resistive) 3 A, 220 VDC L/R (T0.632) = 7 ms 0.2 A, 220 VDC L/R (T0.95) = 300 ms NC contacts 2 A, 220 VDC (Resistive) 0.3 A, 220 VDC L/R (T0.632) = 7 ms 0.1 A, 220 VDC L/R (T0.95) = 300 ms NO contacts 15 A, 250 VAC (Resistive) NO contacts 15 A, 250 VAC (Resistive) NC contacts 5 A, 250 VAC (Resistive) CSA Standard: CSA Certification by Operations 6,000 : CSA C22.2 No.14 IEC Standard/TUV Certification: IEC61810-1 (Certification No. R50104853) Model Coil ratings MKS1XT@-@ MKS2XT@-@ MKS1T@-@ MKS2T@-@ 4 12, 24, 48, 110, 220 VDC 24, 100, 110, 120, 200, 220, 230, 240 VAC Contact ratings NO contacts DC-1: 10 A, 220 VDC 5 A, 220 VDC L/R (T0.632) = 7 ms DC-13: 0.4 A, 220 VDC NO contacts DC-1: 5 A, 220 VDC 3 A, 220 VDC L/R (T0.632) = 7 ms DC-13: 0.2 A, 220 VDC NC contacts DC-1: 2 A, 220 VDC 0.3 A, 220 VDC L/R (T0.632) = 7 ms DC-13: 0.1 A, 220 VDC NO contacts AC-1: 15 A, 250 VAC 50/60 Hz NO contacts AC-1: 15 A, 250 VAC 50/60 Hz NC contacts AC-1: 5 A, 250 VAC 50/60 Hz Operations 100,000 MK-S(X) Engineering Data 100 DC resistive load 10 5 DC inductive load L/R = 7 ms 1 MKS2XT-11, MKS2XTN-11 MKS2XTI-11, MKS2XTIN-11 Switching current (A) Switching current (A) Maximum Switching Power MKS1XT-10, MKS1XTN-10 MKS1XTI-10, MKS1XTIN-10 100 1 10 100 1.000 0.01 Switching voltage (V) DC resistive load NC 15 10 AC resistive load 0.1 1.000 100 1.000 Switching voltage (V) AC resistive load NO 5 0.1 100 10 15 10 1 10 1 100 1 1 DC inductive load DC inductive load DC13 class DC13 class NO NC MKS2T-11, MKS2TN-11 MKS2TI-11, MKS2TIN-11 Switching current (A) 100 0.01 DC inductive load L/R = 7 ms NC 0.1 DC inductive load DC13 class MKS1T-10, MKS1TN-10 MKS1TI-10, MKS1TIN-10 Switching current (A) 5 3 2 0.3 0.2 0.1 0.01 10 1 0.4 DC inductive load L/R = 7 ms NO DC resistive load NO 0.01 Switching voltage (V) AC resistive load NC 1 10 100 1.000 Switching voltage (V) Ambient Temperature vs. Must Operate Voltage and Must Release Voltage MKS2XT-11 MKS2XT-11 Number of Relays: 5 DC Specification Must operate voltage Must release voltage 80 60 40 Must operate/release voltage (%) Must operate/release voltage (%) AC Specification (60 Hz) 100 100 Must operate voltage Must release voltage Number of Relays: 5 80 60 40 20 20 -40 23 60 -40 Ambient temperature (C) 23 60 Ambient temperature (C) 100 220 VDC 10 1 Switching current (A) Switching current (A) Inductive Load Switching Power (Models for DC Loads) MKS1XT-10, MKS1XTN-10 MKS2XT-11, MKS2XTN-11 MKS1XTI-10, MKS1XTIN-10 MKS2XTI-11, MKS2XTIN-11 10 220 VDC NO 1 0.1 NC 0.1 0 7 10 50 100 Load time constant (ms) 0.01 0 7 10 50 100 Load time constant (ms) 5 MK-S(X) Test Button The circuit can be checked using either of two modes. Test Button DC specification: Blue AC specification: Red Test Button Applications Example: Checking operation of Relays and sequence circuits. 6 Normal Mode 1 (momentary) Mode 2 (locked) Press the button for operation. (No tool is required.) Lock the contacts by pressing down on the button and turning it. MK-S(X) Dimensions (Unit: mm) General-purpose Relays Models for DC Loads Standard Models MKS1XT-10 MKS2XT-11 Models with Built-in Operation Indicators MKS1XTN-10 MKS2XTN-11 34.5 max. 34.5 max. Models for AC Loads 0.8 Standard Models MKS1T-10 MKS2T-11 Models with Built-in Operation Indicators MKS1TN-10 MKS2TN-11 44 max. 7.3 3.5 Models for DC Loads Models with Test Button MKS1XTI-10 MKS2XTI-11 Models with Test Button and Built-in Operation Indicators MKS1XTIN-10 MKS2XTIN-11 34.5 max. 34.5 max. Models for AC Loads 0.5 0.8 Models with Test Button MKS1TI-10 MKS2TI-11 Models with Test Button and Built-in Operation Indicators MKS1TIN-10 MKS2TIN-11 44 max. 29.7 7.3 Terminal Arrangement/Internal Connection (Bottom View) MKS1XT-10 MKS1XTI-10 MKS1XTN-10 MKS1XTIN-10 DC specification MKS2XT-11 MKS2XTI-11 MKS2XTN-11 MKS2XTIN-11 AC specification DC specification 2 4 6 (+) 4 8 A 6 (+) 4 8 B A (+) 4 A B MKS1TN-10 MKS1TIN-10 DC specification 6 (+) A 4 6 4 B A (+) A 6 4 B A (+) 6 4 B (-) A A A B AC specification 2 6 4 2 6 4 8 8 B 6 (+) MKS2TN-11 MKS2TIN-11 DC specification 8 4 8 (+) B (-) MKS2T-11 MKS2TI-11 AC specification 8 8 6 (+) 8 (+) 2 4 2 2 8 (+) 8 B (-) MKS1T-10 MKS1TI-10 6 (+) AC specification B A (+) 6 8 B (-) A B Note: 1. Wire properly using the correct coil polarity. 2. The contact terminals on Models for DC Loads have polarity. Wire properly using the correct polarity. 7 MK-S(X) Connecting Socket Back-connecting Socket P7M-06P Dimensions 39 max. Terminal Arrangement/Internal Connections PCB Mounting Holes (Bottom View) (Bottom View) 4 43 max. 2 5.5 6 0.9 8 39 max. A 8.3 7.7 B 21.9 4.35 22.1 7.7 0.9 8.3 5.5 Front-connecting Socket P7MF-06 P7MF-06-D Terminal Arrangement/Internal Connections (TOP View) Dimensions 7 P7MF-06 34 max. 78 max. 39 max. Six, M3 x 8 8 P7MF-06-D Mounting Holes (TOP View) Two, M4 or two 3.5-dia. hole 660.3 35.5 6 4 24.3 Note: 1. The internal connections diagram is for the MKS2(X)T@@-11. 2. The P7MF-06-D has polarity. Be careful to wire with the correct polarity. 310.2 MK-S(X) Accessory (Order Separately) Connecting Socket Socket Back-connecting Socket Front-connecting Socket PCB terminals Mounts to DIN Track or via screws P7M-06P P7MF-06 P7MF-06-D Number of poles 2 Note: 1. The P7M-06P, P7MF-06, and P7MF-06-D can be used with models for DC loads with an SPST-NO or SPST-NO/SPST-NC contact form or with models for AC loads with an SPST-NO or SPST-NO/SPST-NC contact form. 2. The P7MF-06-D has a built-in diode and can thus be used only with Relays with DC operating coils. Do not use it with a Relay with an AC operating coil. 3. Refer to Gang Mounting on page 10 for the conditions required for gang mounting. Relay Hold-down Clips Use the Clips to securely mount the Relay and prevent it from falling due to vibration or shock. Applicable Relay models MKS1XT-10 MKS1XTI-10 MKS1XTIN-10 MKS1XTN-10 MKS1T-10 MKS1TI-10 MKS1TIN-10 MKS1TN-10 Socket Back-connecting Socket PCB terminals P7M-06P Mounts to DIN Track or via screws P7MF-06 Front-connecting Socket PYC-A2 One Set (Two Clips) MKS2XT-11 MKS2XTI-11 MKS2XTIN-11 MKS2XTN-11 MKS2T-11 MKS2TI-11 MKS2TIN-11 MKS2TN-11 5 max. 42.8 PYC-A2 P7MF-06-D 4.5 1.2 4.5 Note: The minimum order for the PYC-A2 is ten clips. Socket Mounting Height P7M-06P 64 MK-S(X) 61 P7MF-06 P7MF-06-D MK-S(X) 74 70 75 79 9 MK-S(X) Safety Precautions Refer also to Precautions for All Relays. Precautions for Correct Use Installation Test Button * Models for DC loads (i.e., models with "X" in the model number) have permanent magnets built into the insulating block. If a permanent magnet or other magnetic body comes near the Relay, magnetic interference will occur with the built-in permanent magnet and the contact switching capacity will be decreased. * Models for AC loads do not contain a permanent magnet. * When mounting a P7MF-06(-D) Front-mounting Socket to a DIN Track, attach PFP-M End Plates on both sides of the Socket to prevent it from moving. Conditions for Gang Mounting Relays Socket Back-Connecting Socket Front-Connecting Socket Models for 10A DC Loads Models for 15A AC Loads * Rated current of Relay Applied current (A) * Gang mounting of the Front-Mounting Sockets is not possible if the contact carry current exceeds 10A.Provide space on both the right and left sides of the Sockets. The mounting pitch is given in the following diagram. 20 15 10 5 0 0 10 20 30 40 50 Mounting interval (mm) Mounting interval Wiring * The contact terminals on Models for DC Loads (i.e., models with "X" in the model number) have polarity. Wiring with incorrect polarity may result in inability to turn OFF the Relay or loss of functionality. * Wire models with built-in operation indicators with the correct coil polarity (DC operating coil). 10 Operating Environment Do not use the Relay in environments with combustible gas. Doing so may result in explosion due to arcing. Storage Gang Mounting Relay * Turn OFF the power supply before operating the test button. Always return the test button to the original position after you use it. * Do not use the test button as a switch. * The durability of the test button is 100 operations minimum. Models for DC Loads (i.e., models with "X" in the model number) are magnetized because they have a built-in magnet to deflect and extinguish the arc. Do not install the Relay near IC cards or other items that may be adversely affected by magnetism. Usage Use the Relay mounted in the P7M-06P or P7MF-06(-D) Socket. MK-S(X) Warranty and Application Considerations Read and Understand this Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used. Know and observe all prohibitions of use applicable to this product. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Disclaimers PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with your OMRON representative at any time to confirm actual specifications of purchased product. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. 11 OMRON Corporation Industrial Automation Company Control Devices Division H.Q. Strategy Planning Division Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 Japan Tel: (81) 75-344-7109/Fax: (81) 75-344-7149 Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69-2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 OMRON ELECTRONICS LLC One Commerce Drive Schaumburg, IL 60173-5302 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 Authorized Distributor: OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 OMRON Industrial Automation Global: www.ia.omron.com (c) OMRON Corporation 2008 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. CSM_5_2_1015 Printed in Japan Cat. No. J175-E1-02 0809