MODEL NO: PAGE NO:1 of 5 PART NO: DTS120500U UNIT: mm | DATE: 06/14/02 All information contained herein applies only to th a above listed part number. Other versions of this part number with electrical or mechanical variations are available. Contact CUl Inc. for further assistance. 9615 SW Allen Bivd., Ste. 103, Beaverton OR 97005 800-275-4899 * 503-643-4899 Fax: 503-643-6129 www.cui.com 1. SPECIFICATION 1-0 INPUT REQUIREMENTS 1-1 INPUT VOLTAGE 100 TO 240 10 Vac FULL RANGE 1-2 INPUT FREQUENCY 47 TO 63 Hz 1-3 INPUT CURRENT 1)12AMAX., AT 115Vac FULL LOAD 2.)0.6 AMAX., AT 230Vac FULL LOAD 1-4 EFFICIENCY 78% TYP. AT FULL LOAD, (CV MODE), NOMINAL LINE 1-5 INRUSH CURRENT 1.) 40A MAX. AT 115Vac COLD START 2.) 80A MAX. AT 230Vac COLD START 1-6 HOLD UP TIME 8.3mS MIN.AT FULL LOAD, NOMINAL LINE 1-7 CONFIGURATION 3-WIRE INPUT AC LINE(LINE ,NEUTRAL,FG) 1-8 INPUT FUSE THE HOT LINE SIDE OF THE INPUT SHALL HAVE A FUSE 1-9 LINE REGULATION THE MAXIMUM VOLTAGE CHANGE ON DC OUTPUT SHALL BE WITHIN TOLERANCE WHEN AC INPUT VOLTAGE VARIES WITHIN THE RANGE SPECIFIED IN 1-1 1-10 INPUT PROTECTION DEVICE AN ADEQUATE INTERNAL FUSE ON THE AC INPUT LINE SHALL BE PROVIDED 1-11 POWER LINE NOISE THE POWER SUPPLY WILL HAVE AN ON BOARD AC FILTER THAT WILL MEET CONDUCTED NOISE SPECIFICATIONS OF FCC AND CISPR 1-12 HI-POT TESTS PRIMARY-SECONDARY 1.5K Vac FOR | MINUTE (LEAKAGE CURRENT 10mA) 1-13 INSULATION RESISTANCE INSULATION RESISTANCE SHALL BE MORE THAN 100Mohm AT 500Vde BETWEEN PRIMARY LINE, NEUTRAL LINE AND SECONDARY MODEL NO: PAGE NO:2 of 5 PART NO: DTS120500U UNIT: mm | DATE: 06/14/02 All information contained herein applies only to th bove listed part number, Other versions of this part number with electrical or mechanical variations are available. Contact CUl Inc. for further assistance. 9615 SW Alien Bivd., Ste. 103, Beaverton OR 97005 800-275-4899 * 503-643-4899 * Fax: 503-643-6129 www.cui.com 2-0 OUTPUT REQUIREMENTS 2-1 DC OUTPUT TOLERANCE OUTPUT CURRENT OUTPUT VOLTAGE | (ACCURACY) MIN. MAX. +12 Vde +/-5 % 0 5.0A 2-2 LOAD REGULATION VOLTAGE TOLERANCE REGULATION +12 Vde +/-5 % 11.4-12.6 Vde 2-3 DYNAMIC LOAD REGULATION +/-5% EXCURSION FOR 50% - 100% OR 100%-50% LOAD CHANGE OF DC OUTPUT AT ANY FREQUENCY UP TO IKHz (DUTY 50%) 2-4 RIPPLE NOISE THE POWER SUPPLY SHALL NOT EXCEED THE FOLLOWING LIMITS ON THE INDICATED VOLTAGES FOR 60Hz OR 50Hz RIPPLE , SWITCHING FREQUENCY RIPPLE AND NOISE AND DYNAMIC LOAD VARIATIONS MEASURED WITH A 20MHz BANDWIDTH OUTPUT RIPPLE/NOISE +12 Vde 150mV OUTPUT: OUT VOLTAGE RIPPLE/NOISE: 60Hz RIPPLE + SWITCHING RIPPLE AND NOISE RIPPLE NOISE ARE MEASURED AT THE END OF OUTPUT CABLES WHICH ARE ADDED A 0.luF CERAMIC CAPACITOR AND A 47uF ELECTROLYTIC CAPACITOR 2-5 OVER CURRENT PROTECTION (OVER POWER PROTECTION) THE POWER SUPPLY SHALL NOT BE DAMAGED BY A OVER CURRENT FROM THE OUTPUT TO RETURN LINE OUTPUT VOLTAGE MIN. MAX. +12 Vde --- TOA 2-6 OVER VOLTAGE PROTECTION 16V MAX. (OUTPUT CLAMPLED WITH ZENER DIODE, DO NOT TEST WITH EXTERNAL DC SOURCE) 2-7 SHORT-CIRCUIT PROTECTION A SHORT CIRCUIT PLACE AT ANY OUTPUT WILL CAUSE NO DAMAGE TO THIS ADAPTER MODEL NO: PAGE NO:3 of 5 PART NO: DTS120500U ro UNIT: mm | DATE: 06/14/02 All information contained herein applies only, s of this part number with electrical or mechanical variations are available. Contact CUl Inc. for further assistance. 9615 SW Allen Bivd., Ste. 103, Beaverton OR 97005 800-275-4899 503-643-4899 * Fax: 503-643-6129 www.cui.com 2-8 OPEN CIRCUIT PROTECTION WHEN PRIMARY POWER IS SUPPLIED WITH NO LOAD ON ANY OUTPUT LEVEL,NO DAMAGES OR HAZARDOUS CONDITIONS SHOULD OCCUR 2-9 STABILITY 2% MAX. AT CONSTANT LOAD WITH CONSTANT INPUT (AFTER 30 MINUTES OF OPERATION) 2-10 DROP-OUT(POWER LINE DISTURBANCE) OUTPUT VOLTAGES SHALL REMAIN WITHIN THE SPECIFIED REGULATION RANGE , THROUGH THE ABSENCE OF A LINE INPUT DURING 1/2 CYCLE, AT FULL LOAD AND MIN.AC LINE INPUT 2-11 VOLTAGE ISOLATION THE DC GROUND WILL BE ISOLATED FROM THE AC NEUTRAL AND AC LINE 2-12 COOLING COOLING SHALL BE NEUTRAL CONVECTION COOLING , THE POWER SUPPLY MUST BE CAPABLE OF OPERATION WHEN MOUNTED EITHER VERTICALLY OR HORIZONTALLY ACCORDING TO THE MECHANICAL DRAWING 2-13 CONTINUITY (GROUNGING) 100m OHM MAX. AT 25A 2-14 LEAKAGE CURRENT 0.75mA MAX. 2-15 LED DISPLAY DESCRIPTION GREEN POWER ON ON POWER OFF OFF 3-0 ENVIRONMENTAL REQUIREMENTS 3-1 TEMPERATURE 1.)OPERATION 0 TO 40 2.)STORAGE 20TO85 3-2 HUMIDITY 1)OPERATION 8 90 RH 2)STORAGE 5 90 RH 3-3 VIBRATION AND SHOCK NO EVIDENCE OF ANY MECHANICAL OR FUNCTIONAL DAMAGE AFTER THE VIBRATION AND SHOCK TESTING MODEL NO: PAGE NO:4 of 5 PART NO: DTS120500U UNIT: mm | DATE: 06/14/02 All information contained herein applies only t . her s of this part number with electrical or mechanical variations are available. Contact CUl Inc. for further assistance. 9615 SW Allen Blivd., Ste. 103, Beaverton OR 97005 800-275-4899 503-643-4899 * Fax: 503-643-6129 www.cui.com g ite 1 ~ ld a E i i | 0 | | _ g . A 9 4 ae ms > 60+/-0.5mm | | 34.5+/-0.5 MODEL NO: PAGE NO:5 of 5 PART NO: DTS120500U UNIT: mm | DATE: 06/14/02 All information contained herein applies only to above lis e part ni num er. er versions of this part number with electrical or mechanical variations are available. Contact CU Inc. for further assistance. 9615 SW Allen Bivd., Ste. 103, Beaverton OR 97005 800-275-4899 * 503-643-4899 * Fax: 503-643-6129 www.cui.com MODEL: EA10S0A-120 PART#: DTS120500UC-P5-ET AC INPUT: 100-240V~18A, 50-60Hz DC QUTPUT: 1eV--= 3.0A 100~240V S0-60Hz, 18A 100~200VA +12V~t+17V 3S.0A Jp bosooeel4 & 60W MAX, CAUTION: FOR INDOOR USE ONLY. LTE, USE ONLY Endast fr Kontorsmaskin Apparaten skall anslutas till Jordat, uttag, nar den ansluts till ett natverk _ [o1joqog 1l2e|3 4 [5 DATE CODE! at3 talstel7 ie p 10 \ LTE, POWER SUPPLY 4iTJ E209833 #ea& 3902B504 LPS MADE IN CHINA