SPECIFICATIONS
Model 1000A100
RATED OUTPUT POWER.......................................................1000 watts
INPUT FOR RATED OUTPUT.................................................1.0 milliwatt maximum
POWER OUTPUT @ 3dB COMPRESSION
Typical..........................................................................1250 watts
Minimum ......................................................................1100 watts
POWER OUTPUT @ 1dB COMPRESSION
Typical..........................................................................1100 watts
Minimum ......................................................................1000 watts
FREQUENCY RESPONSE.......................................................10 kHz - 100 MHz instantaneously
GAIN (at maximum setting)......................................................60 dB minimum
FLATNESS..............................................................................
±±
1.5 dB maximum
±±
0.5 dB with internal leveling
GAIN ADJUSTMENT (continuous range).................................18 dB minimum
INPUT IMPEDANCE...............................................................50 ohms, VSWR 1.5:1 maximum
OUTPUT IMPEDANCE...........................................................50 ohms, VSWR 2.5:1 maximum
MISMATCH TOLERANCE......................................................Will operate without damage, or oscillation with any
magnitude and phase of source and load impedance.
100% of rated power without foldback up to 6.0:1 mismatch, above
which may limit to 500 watts reflected power.
May limit at rated output.
MODULATION CAPABILITY..................................................Will faithfully reproduce AM, FM, or Pulse modulation
appearing on the input signal.
HARMONIC DISTORTION.....................................................Minus 20 dBc maximum at specified minimum 1dB
compressed power
THIRD ORDER INTERCEPT POINT.......................................68 dBm typical
RF POWER METER................................................................0 - 1200 watts full scale
PULSE MODE GATING CHARACTERISTICS
Signal (into 50 ohms).......................................................+ 2.0 to 6.0 VDC
Rise Time........................................................................0.5 microseconds maximum
Fall Time........................................................................0.5 microseconds maximum
RF Rise/Fall Time...........................................................10 nanoseconds maximum
PRIMARY POWER..................................................................See Model Configuration
CONNECTORS
RF..................................................................................See Model Configuration
External Leveling Inputs..................................................Type BNC female on front panel
Pulse Modulation Inputs..................................................Type BNC female on front panel
Detected RF Output.........................................................Type BNC female on front panel
Remote Control................................................................25 pin female subminiature D
COOLING...............................................................................Forced air (self contained fans)
WEIGHT, maximum.................................................................150 kg (330 lb)
SIZE (WxHxD)........................................................................56.1 x 149.9 x 58.4 cm
22.1 x 59.0 x 23.0 in
Model Configuration
Model Number Input Connector Output Connector Primary Power
1000A100 BNC female on front panel Type “C” female on front panel 180-240VAC, 50 -60Hz, single phase 6500 W Max
1000A100M1 BNC female on rear panel 7/16 female on rear panel 180-240VAC, 50 -60Hz single phase 6500W max
1000A100M2 BNC female on rear panel Type “C” female on rear panel 180-240VACm 50 -60Hz, single phase
1000A100M3 BNC female on front panel Type “C” female on front panel 400VAC, 50-60Hz, 3 phase, 5 wire, WYE connected,6500W max
1000A100M4 BNC female on front panel Type “C” female on front panel 208VAC, 50-60Hz, 3 phase, Delta connected, 6500W max
1000A100M5 BNC female on rear panel Type “C” female on rear panel 400VAC, 50-60Hz, 3 phase, 5 wire, WYE connected, 6500W max
1000A100M6 BNC female on rear panel Type “C” female on rear panel 208VAC, 50-60Hz, 3 phase, Delta connected, 6500W max