50SQ... Series
Bulletin PD-2.060 rev. F 03/03
2www.irf.com
VFM Max. Forward Voltage Drop (1) 0.66 V @ 5A
* See Fig. 1 0.77 V @ 10A
0.52 V @ 5A
0.62 V @ 10A
IRM Max. Reverse Leakage Current (1) 0.55 mA TJ = 25 °C
* See Fig. 2 7 mA TJ = 125 °C
CTMax. Junction Capacitance 500 pF VR = 5VDC, (test signal range 100Khz to 1Mhz) 25 °C
LSTypical Series Inductance 10 nH Measured lead to lead 5mm from body
dv/dt Max. Voltage Rate of Change 10000 V/ µs
(Rated VR)
TJ = 25 °C
TJ = 125 °C
VR = rated VR
Parameters 50SQ Units Conditions
Electrical Specifications
TJMax. Junction Temperature Range -55 to 175 °C
Tstg Max. Storage Temperature Range -55 to 175 °C
RthJL Max. Thermal Resistance Junction 8.0 °C/W DC operation * See Fig. 4
to Lead 1/8 inch lead leangth
RthJA Typical Thermal Resistance, 44 °C/W
Junction to Air
wt Approximate Weight 1.4(0.049) g (oz.)
Case Style DO - 204AR JEDEC
Thermal-Mechanical Specifications
Parameters 50SQ Units Conditions
(1) Pulse Width < 300µs, Duty Cycle < 2%
IF(AV) Max. Average Forward Current 5 A 50% duty cycle @ TC = 119° C, rectangular wave form
* See Fig. 5
IFSM Max. Peak One Cycle Non-Repetitive 1900 5µs Sine or 3µs Rect. pulse
Surge Current * See Fig. 7 290 10ms Sine or 6ms Rect. pulse
EAS Non-Repetitive Avalanche Energy 7.5 mJ TJ = 25 °C, IAS = 1.0 Amps, L = 15 mH
IAR Repetitive Avalanche Current 1.0 A Current decaying linearly to zero in 1 µsec
Frequency limited by TJ max. VA = 1.5 x VR typical
Parameters 50SQ Units Conditions
Absolute Maximum Ratings
A
Part number 50SQ060 50SQ080 50SQ100
VRMax. DC Reverse Voltage (V) 60 80 100
VRWM Max. Working Peak Reverse Voltage (V)
Voltage Ratings
Following any rated
load condition and
with rated VRRM applied