TECHNICAL DATASHEET ADP Series Power Adapters 19V 40W/65W/90W ADP 19V Highlights & Features - - - - - Energy Star Compliance (Level VI) IT safety approvals 100k Hours MTBF Over-Voltage/Load/Temperature & Short Circuit protections Low Leakage Current Safety Standards CB Certified for worldwide use Model Information ADP Series Power Adapters Model Number Input Voltage Range Output Voltage Output Current ADP-40KD BBBM 90-264Vac 19Vdc 2.1A ADP-65JH HBAN 90-264Vac 19Vdc 3.42A ADP-90MD HDM 90-264Vac 19Vdc 4.74A Specifications Input Ratings / Characteristics ADP-40KD BBBM ADP-65JH HBAN Nominal Input Voltage 100-240Vac Input Voltage Range 90-264Vac Nominal Input Frequency 50-60Hz Input Frequency Rang Input Current 47-63Hz 1.2A Max at 100Vac input voltage Inrush Current Limit (cold start) Efficiency at nominal input voltage 85% 84% >88% >85.30% No Load Power Consumption <0.1W @ 115Vac/60Hz , <0.3W @ 230Vac/50Hz Leakage Current <100uA at 240Vac/50Hz 1 1.5A Max at 100Vac input voltage No Damage Active Mode Efficiency @ 115Vac Active Mode Efficiency @ 230Vac ADP-90MD HDM www.DeltaPSU.com (January 2016, Rev. 1.0) >87% >88% <0.21W @ 115Vac/60Hz <50uA at 240Vac/50Hz <75uA at 240Vac/50Hz TECHNICAL DATASHEET ADP Series Power Adapters 19V 40W/65W/90W Output Ratings / Characteristics ADP-40KD BBBM ADP-65JH HBAN Rated Voltage 19V Voltage Range 18.05 ~ 19.95V Current Output Ripple and Noise Turn On delay time ADP-90MD HDM 2.1A 3.42A 4.74A 350 mV pk-pk 300mV pk-pk 380mV pk-pk 5 seconds @ 100-240Vac 2 seconds @ 100-240Vac Hold-up Time The output voltage shall be sustained 5mS within regulation requirement after loss 100Vac and maximum load. Rise Time DC output rise time from 10% to 90% of output voltage shall be less than 30mS at nominal line and maximum load Transient Load Response 0.1A to 100% load at 2.5A/us slew rate and frequency is 10Hz to 10KHz DC output rise time from 10% to 90% of output voltage shall be less than 100ms at nominal line and maximum load 0% to 50% and 50% to 100% 1.0A/us slew rate and frequency is 100Hz Environment ADP-40KD BBBM ADP-65JH HBAN Operating Temperature ADP-90MD HDM 0 C to +40 C Shipping/Storage Temperature -30 C to +80 C -20 C to +85 C. Operating Humidity 8% to 90% RH (Non-Condensing) Shipping/Storage Humidity 5% to 95% RH (Non-Condensing) Lightning Surge Immunity IEC-1000-4-5 Level 3 Requirements L-N 1KV/1.2 * 50uS 5 times No damage Electric Fast Transients (EFT) Electrostatic Discharge (ESD) IEC-61000-4-5 Level 3 requirements L-N 1KV/1.2 * 50uS 5 times No function error L-FG 2KV/1.2 * 50uS 5 times No damage. IEC-1000-4-4/1995 EN 61000-4-4 15KV air discharge 8KV contact discharge Between AC input and secondary AC 3KV test time 1 minute; 100% of line products of this Adapter shall be applied 3000Vac for 2 seconds between AC input terminals and output terminals. Cut off current 10mA. Dielectric Withstand Voltage (HIPOT) Between AC input and secondary AC 3KV test time 1 minute; 100% of line products of this Adapter shall be applied 3000Vac for 2 seconds between AC input terminals and output terminals. Cut off current 3mA. Insulation Resistance The insulation resistance shall be not less than 30M ohms after application of 500Vdc/10mA for 1 minute. Electromagnetic Interference (EMI) MTBF (a) FCC Class B (b) CISPR 22 Class B (c) VCCI Class B 150,000 hours Altitude 2 (a) FCC Class B (b) CISPR 22 Class B (c) VCCI Class B The insulation resistance shall be not less than 20M ohms after application of 500Vdc/10mA for 1 minute (a) FCC Class B (b) CISPR 22 Class B (c) VCCI Class B 100,000 hours 5,000m (16,400 ft) www.DeltaPSU.com (January 2016, Rev. 1.0) 100% of line products of this Adapter shall be applied 3000Vac for 1 seconds between AC input terminals and output terminals. Cut off current is 10mA. TECHNICAL DATASHEET ADP Series Power Adapters 19V 40W/65W/90W Protections Over Voltage Overload / Overcurrent ADP-40KD BBBM ADP-65JH HBAN ADP-90MD HDM The output shall be protected to latch off at over-voltage condition, maximum value can't be over 29V. The output shall be protected to latch off at over-voltage condition, maximum value can't be over 27V. The output shall be protected to latch off at over-voltage condition, maximum value shall be more than 22V and be less than 27V. The maximum constant current shall be more than 4.1A. The adapter shall be Auto-recovery The minimum constant current shall be more than 5.214A. The maximum constant current shall be less than 6.636A. The output shall be protected to latch off at over-current condition. The maximum constant current shall be more than 2.1A and be less than 5.0A at 90Vac and 264Vac. The adaptor shall be autorecovery. Latch Mode Over Temperature Auto-Recovery Short Circuit Mechanical ADP-40KD BBBM Color ADP-65JH HBAN ADP-90MD HDM Black Outline Dimensions (L x W x D) 89.5 * 37.0 * 26.5 mm 3.52 * 1.45 * 1.04 in AC Inlet Type DC Cable Type 108.0 * 46.0 * 29.5 mm 4.25 * 1.81 * 1.16 in 127.0 * 51.0 * 30.5 mm 5.0 * 2.0 * 1.2 in Socket C6 type UL 1571 22AWG DC Cable Length UL1571 #AWG18 #AWG18 1800 mm DC Connector - OD 5.5 mm 5.5 mm 5.5 mm DC Connector - ID 2.5 mm 2.5 mm 1.7 mm DC Connector - Length 12.5 mm 11 mm 11 mm 3 www.DeltaPSU.com (January 2016, Rev. 1.0) TECHNICAL DATASHEET ADP Series Power Adapters 19V 40W/65W/90W Mechanical ADP-40KD BBM ADP-65JH HBAN 4 www.DeltaPSU.com (January 2016, Rev. 1.0) TECHNICAL DATASHEET ADP Series Power Adapters 19V 40W/65W/90W ADP-90MD HDM 5 www.DeltaPSU.com (January 2016, Rev. 1.0)