PBA/PBW-2
MODEL PBA10F-5 PBA10F-12 PBA10F-24
MAX OUTPUTWATTAGE[W] 10 10.8 12
DC OUTPUT 5V 2A 12V 0.9A 24V 0.5A
SPECIFICATIONS
MODEL PBA10F-5 PBA10F-12 PBA10F-24
INPUT
VOLTAGE[V] AC85 -264 1for DC110-370 (AC50 or DC70 Please refer to the instruction manual 2.1 Inputvoltage *3)
CURRENT[A]
ACIN 100V
0.30typ (Io=100%)
ACIN 200V
0.20typ (Io=100%)
FREQUENCY[Hz] 50/60 (47-440)or DC
EFFICIENCY[%]
ACIN 100V
74typ 76typ 77typ
ACIN 200V
74typ 76typ 77typ
INRUSH CURRENT[A]
ACIN 100V
15typ (Io=100%)
ACIN 200V
30typ (Io=100%)
LEAKAGE CURRENT[mA] 0.15/0.30max (ACIN 100V/240V 60Hz,Io=100%,Accordingto IEC60950-1,DENAN)
OUTPUT
VOLTAGE[V] 51224
CURRENT[A] 2 0.9 0.5
LINE REGULATION[mV] 20max 48max 96max
LOAD REGULATION[mV] 40max 100max 150max
RIPPLE[mVp-p]
0to +50C
*1
80max 120max 120max
-10-0C
*1
*6
*6
140max 160max 160max
RIPPLE NOISE[mVp-p]
0to +50C
*1
120max 150max 150max
-10-0C
*1
160max 180max 180max
TEMPERATURE REGULATION[mV]
0to +50C
50max 120max 240max
-10to +50C
60max 150max 290max
DRIFT[mV]
*2
20max 48max 96max
START-UP TIME[ms]
200typ(ACIN 100V,Io=100%)*Start-up time is 700mstyp forlessthan 1minute of applying input again from turning off the inputvoltage.
HOLD-UP TIME[ms] 20typ (ACIN 100V,Io=100%)
OUTPUTVOLTAGE ADJUSTMENT RANGE[V]
4.50-5.50 10.0-13.2 19.2 - 27.0
OUTPUTVOLTAGE SETTING[V]
5.00-5.15 12.00 - 12.48 24.00-24.96
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Worksover 105%ofrated current and recovers automatically
OVERVOLTAGE PROTECTION[V]
5.75-7.00 15.0-18.0 30.0 - 37.0
OPERATING INDICATION LED (Green)
REMOTE ON/OFF None
ISOLATION
INPUT-OUTPUT AC3,000V 1minute,Cutoff current=10mA,DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V 1minute,Cutoff current=10mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-FG AC500V1minute,Cutoff current=25mA,DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATINGTEMP.,HUMID.ANDALTITUDE
-10 to +71C(Required Derating), 20-90%RH (Non condensing)3,000m (10,000feet)max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C,20-90%RH (Non condensing)9,000m (30,000feet)max
VIBRATION 10 - 55Hz,19.6m/s2(2G), 3minutes period,60minutes each along X,Y andZaxis
IMPACT196.1m/s2(20G), 11ms,once eachX
,Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS (At onlyACinput)
UL60950-1,C-UL(CSA60950-1), EN60950-1,EN50178 Complies with DEN-AN
CONDUCTED NOISE Complies withFCC Part15 classB,VCCI-B,CISPR22-B,EN55011-B,EN55022-B
HARMONICATTENUATOR Complies with IEC61000-3-2 (Notbuilt-into active filter *4)
OTHERS CASE SIZE/WEIGHT 31X78X68mm [1.22X3.07X2.68 inches] (without terminalblock)(
WXHXD)/ 150g max (with cover : 180g max)
COOLING METHOD Convection
*7
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN
:RM101).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3
Derating is required.
*4 When two or more units are used,they may not comply with the harmonic attenuator. Please
contact us for details.
*5
Please contact us about safety approvals for the model with option.
*6
Please contact us about dynamic load and input response.
*7
Please contact us about class C.
*
Parallel operation with other model is not possible.
*
Derating is required when operated with cover.
*
A sound may occur from power supply at peak loading.
PBA10F
AC-DC Power Supplies Enclosed Type
PB A 10 F -O -O
Ordering information
1 Series name
2 Single output
3 Output wattage
4 Universal input
5 Output voltage
6 Optional *5
C : with Coating
G :
Low leakage current
E :
Low leakage current
and EMI class A
T :
Vertical terminal block
J : Connector type
N : with Cover
(UL508 is acquired)
N1
: with DIN rail and Cover
V :
Output voltage setting
potentiometer external-
ly
R
1 2 3 4 5 6
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
Cover is optional
Example recommended EMI/EMC filter
NAC-06-472
*
A higher current rating EMI/EMC filter
may be recommended in view of the
other devices that could be connected
in parallel with the power supply.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
PBA/PBW-3
2.5
Cover name plate
Cover (option)
Name plate
M3
Mounting hole
2-M3
Mounting hole
2-M3
AC(N)
AC(L)
FG
-V
+V
Terminal cover Point A:C102
68
34.5
78
15.1±1.5
7.5
9.5
49.5±0.5
36±0.5
16.5±2
31
18
11
34.5
4
22.6±1.5
11.5
18
[0.71]
[0.65] [2.68]
[1.95]
[1.42] [0.43]
[0.16]
[0.59]
[0.89]
[0.1]
[0.48]
12.2±1.5
70.5
[2.78]
[0.3][0.37]
[1.36]
[1.36]
[1.22]
[0.71]
[3.07]
[0.45]
PBA10F
LED
Voltage adjust
Tolerance : ±1 [±0.04]
Weight : 150g max (with cover : 180g max)
PCB Material/thickness : CEM3 / 1.6mm [0.06]
Chassis material : Electric galvanizing steel board
Dimensions in mm, [ ]= inches
Mounting torque : 0.6N m(6.3kgf cm)max
Screw tightening torque : M3 0.8N m(8.5kgf cm)max
Please connect safety ground to the unit in 2-M3 holes.
External size of option T,J,N,N1 and V is different from standard model and refer to 7 Option of instruction manual for details.
Block diagram
2.5A
AC250V
NOISE
FILTER
INVERTERCONTROL
CURRENT
SENSING
RECTIFIER
AND
FILTER
CONTROL
AC IN
DC OUT
FG
Photocoupler
Photocoupler
TRANSFORMER
85 - 264V
INRUSH
CURRENT
LIMIT
FUSE
OVER VOLTAGE
PROTECTION
RECTIFIER
AND
FILTER
External view
PBA10F
PBA/PBW-4
MODEL PBA15F-3R3 PBA15F-5 PBA15F-9 PBA15F-12 PBA15F-15 PBA15F-24 PBA15F-48
MAX OUTPUTWATTAGE[W] 9.9 15 15.3 15.6 15 16.8 16.8
DC OUTPUT 3.3V3A5V3A9V 1.7A 12V 1.3A 15V 1A 24V 0.7A 48V 0.35A
SPECIFICATIONS
MODEL PBA15F-3R3 PBA15F-5 PBA15F-9 PBA15F-12 PBA15F-15 PBA15F-24 PBA15F-48
INPUT
VOLTAGE[V] AC85 -264 1for DC110-370 (AC50 or DC70 Please refer to the instruction manual 2.1 Inputvoltage *3)
CURRENT[A]
ACIN 100V
0.30typ (Io=100%)
0.4typ (Io=100%)
ACIN 200V
0.15typ (Io=100%)
0.2typ (Io=100%)
FREQUENCY[Hz] 50/60 (47-440)or DC
EFFICIENCY[%]
ACIN 100V
68typ 74typ 75typ 75typ 77typ 75typ 75typ
ACIN 200V
68typ 75typ 77typ 78typ 80typ 78typ 78typ
INRUSH CURRENT[A]
ACIN 100V
15typ (Io=100%)(
At cold start)
ACIN 200V
30typ (Io=100%)(
At cold start)
LEAKAGE CURRENT[mA] 0.15/0.30max (ACIN 100V/240V 60Hz,Io=100%,Accordingto IEC60950-1,DENAN)
OUTPUT
VOLTAGE[V] 3.3 5912152448
CURRENT[A] 331.7 1.3 1 0.7 0.35
LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 192max
LOAD REGULATION[mV] 40max 40max 100max 100max 120max 150max 240max
RIPPLE[mVp-p]
0to +50C
*1
80max 80max 120max 120max 120max 120max 150max
-10-0C
*1
*6
*6
140max 140max 160max 160max 160max 160max 200max
RIPPLE NOISE[mVp-p]
0to +50C
*1
120max 120max 150max 150max 150max 150max 250max
-10-0C
*1
160max 160max 180max 180max 180max 180max 300max
TEMPERATURE REGULATION[mV]
0to +50C
50max 50max 90max 120max 150max 240max 480max
-10to +50C
60max 60max 120max 150max 180max 290max 600max
DRIFT[mV]
*2
20max 20max 36max 48max 60max 96max 192max
START-UP TIME[ms]
200typ(ACIN 100V,Io=100%)*Start-up time is 700mstyp forlessthan 1minute of applying input again from turning off the inputvoltage.
HOLD-UP TIME[ms] 20typ (ACIN 100V,Io=100%)
OUTPUTVOLTAGE ADJUSTMENT RANGE[V]
2.85-3.60 4.50-5.50 7.50-10.0 10.0-13.2 13.2 - 18.0 19.2 - 27.0 39.0-53.0
OUTPUTVOLTAGE SETTING[V]
3.30-3.40 5.00-5.15 9.00-9.36 12.00 - 12.48 15.00-15.60 24.00-24.96 48.00-49.92
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Worksover 105%ofrated current and recovers automatically
OVERVOLTAGE PROTECTION[V]
4.00-5.25 5.75-7.00 11.5-14.0 15.0-18.0 20.0 - 25.0 30.0 - 37.0 58.0-65.0
OPERATING INDICATION LED (Green)
REMOTE ON/OFF None
ISOLATION
INPUT-OUTPUT AC3,000V 1minute,Cutoff current=10mA,DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V 1minute,Cutoff current=10mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-FG AC500V1minute,Cutoff current=25mA,DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATINGTEMP.,HUMID.ANDALTITUDE
-10 to +71C(Required Derating), 20-90%RH (Non condensing)3,000m (10,000feet)max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C,20-90%RH (Non condensing)9,000m (30,000feet)max
VIBRATION 10 - 55Hz,19.6m/s2(2G), 3minutes period,60minutes each along X,Y andZaxis
IMPACT196.1m/s2(20G), 11ms,once eachX
,Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS (At onlyACinput)
UL60950-1,C-UL(CSA60950-1), EN60950-1,EN50178 Complies with DEN-AN
CONDUCTED NOISE Complies withFCC Part15 classB,VCCI-B,CISPR22-B,EN55011-B,EN55022-B
HARMONICATTENUATOR Complies with IEC61000-3-2 (Notbuilt-into active filter *4)
OTHERS CASE SIZE/WEIGHT 31X78X85mm [1.22X3.07X3.35 inches] (without terminalblock)(
WXHXD)/ 200g max (with cover : 235g max)
COOLING METHOD Convection
*7
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN
:RM101).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3
Derating is required.
*4 When two or more units are used,they may not comply with the harmonic attenuator. Please
contact us for details.
*5
Please contact us about safety approvals for the model with option.
*6
Please contact us about dynamic load and input response.
*7
Please contact us about class C.
*
Parallel operation with other model is not possible.
*
Derating is required when operated with cover.
*
A sound may occur from power supply at peak loading.
PBA15F
AC-DC Power Supplies Enclosed Type
PB A 15 F -O -O
Ordering information
1 Series name
2 Single output
3 Output wattage
4 Universal input
5 Output voltage
6 Optional *5
C : with Coating
G :
Low leakage current
E :
Low leakage current
and EMI class A
T :
Vertical terminal block
J : Connector type
N : with Cover
(UL508 is acquired
[5V
, 12V, 24V])
N1
: with DIN rail and Cover
V :
Output voltage setting
potentiometer external-
ly
R
1 2 3 4 5 6
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
Cover is optional
Example recommended EMI/EMC filter
NAC-06-472
*
A higher current rating EMI/EMC filter
may be recommended in view of the
other devices that could be connected
in parallel with the power supply.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
PBA/PBW-5
2.5
Point A:C102
Cover (option)
Name plate
M3
Mounting hole
2-M3
Mounting hole
2-M3
AC(N)
AC(L)
FG
-V
+V
Terminal cover
15.1±1.5
5
18
31
34.5
34.5
78
36.5
11.5
85
16.5±2
70.5
12.2±1.5
18
22.6±1.5
31±0.5
60±0.5
9.5 7.5
PBA15F
PBW15F
LED
Voltage adjust
Cover name plate
Tolerance : ±1 [±0.04]
Weight : 200g max (with cover : 235g max)
PCB Material/thickness : CEM3 / 1.6mm [0.06]
Chassis material : Electric galvanizing steel board
Dimensions in mm, [ ]= inches
Mounting torque : 0.6N m(6.3kgf cm)max
Screw tightening torque : M3 0.8N m(8.5kgf cm)max
Please connect safety ground to the unit in 2-M3 holes.
External size of option T,J,N,N1 and V is different from standard model and refer to 7 Option of instruction manual for details.
[0.71]
[0.65] [3.35]
[1.22]
[2.36] [0.2]
[1.44]
[0.59]
[0.89]
[0.1]
[0.48]
[2.78]
[0.3][0.37]
[1.36]
[1.36]
[1.22]
[0.71]
[3.07]
[0.45]
Block diagram
2.5A
AC250V
AC IN
DC OUT
FG
85 - 264V
NOISE
FILTER
INVERTERCONTROL
CURRENT
SENSING
RECTIFIER
AND
FILTER
CONTROL
Photocoupler
Photocoupler
TRANSFORMER
INRUSH
CURRENT
LIMIT
FUSE
OVER VOLTAGE
PROTECTION
RECTIFIER
AND
FILTER
External view
PBA15F
PBA/PBW-6
MODEL PBA30F-3R3 PBA30F-5 PBA30F-9 PBA30F-12 PBA30F-15 PBA30F-24 PBA30F-48
MAX OUTPUTWATTAGE[W] 19.8 30 30.6 30 30 31.2 31.2
DC OUTPUT 3.3V6A5V6A9V 3.4A 12V 2.5A 15V 2A 24V 1.3A 48V 0.65A
SPECIFICATIONS
MODEL PBA30F-3R3 PBA30F-5 PBA30F-9 PBA30F-12 PBA30F-15 PBA30F-24 PBA30F-48
INPUT
VOLTAGE[V] AC85 -264 1for DC110-370 (AC50 or DC70 Please refer to the instruction manual 2.1 Inputvoltage *3)
CURRENT[A]
ACIN 100V
0.50typ (Io=100%)
0.70typ (Io=100%)
ACIN 200V
0.30typ (Io=100%)
0.40typ (Io=100%)
FREQUENCY[Hz] 50/60 (47-440)or DC
EFFICIENCY[%]
ACIN 100V
68typ 74typ 75typ 76typ 78typ 78typ 79typ
ACIN 200V
69typ 77typ 77typ 78typ 81typ 81typ 81typ
INRUSH CURRENT[A]
ACIN 100V
15typ (Io=100%)(
At cold start)
ACIN 200V
30typ (Io=100%)(
At cold start)
LEAKAGE CURRENT[mA] 0.30/0.65max (ACIN 100V/240V 60Hz,Io=100%,Accordingto IEC60950-1,DENAN)
OUTPUT
VOLTAGE[V] 3.3 5912152448
CURRENT[A] 663.4 2.5 2 1.3 0.65
LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 192max
LOAD REGULATION[mV] 40max 40max 100max 100max 120max 150max 240max
RIPPLE[mVp-p]
0to +50C
*1
80max 80max 120max 120max 120max 120max 150max
-10-0C
*1
*6
*6
140max 140max 160max 160max 160max 160max 200max
RIPPLE NOISE[mVp-p]
0to +50C
*1
120max 120max 150max 150max 150max 150max 250max
-10-0C
*1
160max 160max 180max 180max 180max 180max 300max
TEMPERATURE REGULATION[mV]
0to +50C
50max 50max 90max 120max 150max 240max 480max
-10to +50C
60max 60max 120max 150max 180max 290max 600max
DRIFT[mV]
*2
20max 20max 36max 48max 60max 96max 192max
START-UP TIME[ms]
200typ(ACIN 100V,Io=100%)*Start-up time is 700mstyp forlessthan 1minute of applying input again from turning off the inputvoltage.
HOLD-UP TIME[ms] 20typ (ACIN 100V,Io=100%)
OUTPUTVOLTAGE ADJUSTMENT RANGE[V]
2.85-3.60 4.50-5.50 7.50-10.0 10.0-13.2 13.2 - 18.0 19.2 - 27.0 39.0-53.0
OUTPUTVOLTAGE SETTING[V]
3.30-3.40 5.00-5.15 9.00-9.36 12.00 - 12.48 15.00-15.60 24.00-24.96 48.00-49.92
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Worksover 105%ofrated current and recovers automatically
OVERVOLTAGE PROTECTION[V]
4.00-5.25 5.75-7.00 11.5-14.0 15.0-18.0 20.0 - 25.0 30.0 - 37.0 58.0-65.0
OPERATING INDICATION LED (Green)
REMOTE ON/OFF None
ISOLATION
INPUT-OUTPUT AC3,000V 1minute,Cutoff current=10mA,DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V 1minute,Cutoff current=10mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-FG AC500V1minute,Cutoff current=25mA,DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATINGTEMP.,HUMID.ANDALTITUDE
-10 to +71C(Required Derating), 20-90%RH (Non condensing)3,000m (10,000feet)max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C,20-90%RH (Non condensing)9,000m (30,000feet)max
VIBRATION 10 - 55Hz,19.6m/s2(2G), 3minutes period,60minutes each along X,Y andZaxis
IMPACT196.1m/s2(20G), 11ms,once eachX
,Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS (At onlyACinput)
UL60950-1,C-UL(CSA60950-1), EN60950-1,EN50178 Complies with DEN-AN
CONDUCTED NOISE Complies withFCC Part15 classB,VCCI-B,CISPR22-B,EN55011-B,EN55022-B
HARMONICATTENUATOR Complies with IEC61000-3-2 (Notbuilt-into active filter *4)
OTHERS CASE SIZE/WEIGHT 31X78X103mm [1.22X3.07X4.06 inches] (without terminal block)(
WXHXD)/ 270g max (with cover : 310g max)
COOLING METHOD Convection
*7
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN
:RM101).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3
Derating is required.
*4 When two or more units are used,they may not comply with the harmonic attenuator. Please
contact us for details.
*5
Please contact us about safety approvals for the model with option.
*6
Please contact us about dynamic load and input response.
*7
Please contact us about class C.
*
Parallel operation with other model is not possible.
*
Derating is required when operated with cover.
*
A sound may occur from power supply at peak loading.
PBA30F
AC-DC Power Supplies Enclosed Type
PB A 30 F -O -O
Ordering information
1 Series name
2 Single output
3 Output wattage
4 Universal input
5 Output voltage
6 Optional *5
C : with Coating
G :
Low leakage current
E :
Low leakage current
and EMI class A
T :
Vertical terminal block
J : Connector type
N : with Cover
(UL508 is acquired
[5V
, 12V, 24V])
N1
: with DIN rail and Cover
V :
Output voltage setting
potentiometer external-
ly
R
1 2 3 4 5 6
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
Cover is optional
Example recommended EMI/EMC filter
NAC-06-472
*
A higher current rating EMI/EMC filter
may be recommended in view of the
other devices that could be connected
in parallel with the power supply.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
PBA/PBW-7
2.5
Terminal cover
+V
-V
FG
AC(L)
AC(N)
M3
Name plate
Cover (option)
Cover name plate
Point A:C102
2-M3
Mounting hole
2-M3
Mounting hole
15.1±1.5
22.6 ±1.5
8.5
75 ±0.5
40.546±0.5
36.5
16.5±2
11.5 9.5 7.5
18
70.5
12.2 ±1.5
18
78
103
31
34.5
PBA30F
PBW30F
Tolerance : ±1 [±0.04]
Weight : 270g max (with cover : 310g max)
PCB Material/thickness : CEM3 / 1.6mm [0.06]
Chassis material : Electric galvanizing steel board
Dimensions in mm, [ ]= inches
Mounting torque : 0.6N m(6.3kgf cm)max
Screw tightening torque : M3 0.8N m(8.5kgf cm)max
Please connect safety ground to the unit in 2-M3 holes.
External size of option T,J,N,N1 and V is different from standard model and refer to 7 Option of instruction manual for details.
LED
Voltage adjust
[0.71]
[0.65] [4.06]
[1.81]
[2.95]
[0.33]
[1.59]
[0.59]
[0.89]
[0.1]
[0.48]
[2.78]
[0.3][0.37]
[1.44]
[1.36]
[1.22]
[0.71]
[3.07]
[0.45]
Block diagram
3.15A
AC250V
AC IN
DC OUT
FG
85 - 264V
NOISE
FILTER
INVERTERCONTROL
CURRENT
SENSING
RECTIFIER
AND
FILTER
RECTIFIER
AND
FILTER
CONTROL
Photocoupler
Photocoupler
TRANSFORMER
INRUSH
CURRENT
LIMIT
FUSE
OVER VOLTAGE
PROTECTION
External view
PBA30F
PBA/PBW-8
MODEL PBA50F-3R3 PBA50F-5 PBA50F-9 PBA50F-12 PBA50F-15 PBA50F-24 PBA50F-36 PBA50F-48
MAX OUTPUTWATTAGE[W] 33 50 50.4 51.6 52.5 52.8 50.4 52.8
DC OUTPUT 3.3V 10A 5V 10A 9V 5.6A 12V 4.3A 15V 3.5A 24V 2.2A 36V 1.4A 48V 1.1A
SPECIFICATIONS
MODEL PBA50F-3R3 PBA50F-5 PBA50F-9 PBA50F-12 PBA50F-15 PBA50F-24 PBA50F-36 PBA50F-48
INPUT
VOLTAGE[V] AC85 - 264 1for DC120-370 (AC50 or DC70 Please refer to the instructionmanual 2.1 Inputvoltage *4)
CURRENT[A]
ACIN 100V
0.5typ 0.7typ
ACIN 200V
0.3typ 0.4typ
FREQUENCY[Hz] 50/60 (47 -63)
EFFICIENCY[%]
ACIN 100V
75typ 80typ 79typ 80typ 81typ 82typ 83typ 83typ
ACIN 200V
76typ 82typ 81typ 82typ 83typ 84typ 85typ 85typ
POWER FACTOR(Io=100%)
ACIN 100V
0.98typ 0.99typ
ACIN 200V
0.87typ 0.93typ
INRUSH CURRENT[A]
ACIN 100V
15typ (Io=100%)(
At cold start)
ACIN 200V
30typ (Io=100%)(
At cold start)
LEAKAGE CURRENT[mA] 0.4/0.75max (ACIN 100V/240V 60Hz,Io=100%,Accordingto IEC60950-1,DENAN)
OUTPUT
VOLTAGE[V] 3.3 591215243648
CURRENT[A] 10 10 5.6 4.3 3.5 2.2 1.4 1.1
LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 144max 192max
LOAD REGULATION[mV] 40max 40max 100max 100max 120max 150max 240max 240max
RIPPLE[mVp-p]
0to +50C
*1
80max 80max 120max 120max 120max 120max 150max 150max
-10 -0
C
*1
140max 140max 160max 160max 160max 160max 200max 200max
RIPPLE NOISE[mVp-p]
0to +50C
*1
120max 120max 150max 150max 150max 150max 250max 250max
-10 -0
C
*1
160max 160max 180max 180max 180max 180max 300max 300max
TEMPERATURE REGULATION[mV]
0to +50C
50max 50max 90max 120max 150max 240max 360max 480max
-10to +50C
60max 60max 120max 150max 180max 290max 450max 600max
DRIFT[mV]
*2
20max 20max 36max 48max 60max 96max 144max 192max
START-UP TIME[ms] 350typ(ACIN 100V,Io=100%)
HOLD-UP TIME[ms] 20typ (ACIN 100V,Io=100%)
OUTPUTVOLTAGE ADJUSTMENT RANGE[V]
2.85-3.63 4.00 - 5.50 7.50 - 10.0 10.0-13.2 13.2 - 18.0 19.2 - 27.0 28.8 - 39.6 39.0-53.0
OUTPUTVOLTAGE SETTING[V]
3.30-3.40 5.00 - 5.15 9.00 - 9.36 12.00-12.48 15.00-15.60 24.00 - 24.96 35.00 - 37.44 48.00-49.92
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION Worksover 105% of rated current and recovers automatically
OVERVOLTAGE PROTECTION[V]
4.00-5.25 5.75 - 7.00 11.5 - 14.0 15.0-18.0 20.0 - 25.0 30.0 - 37.0 43.0 - 50.0 58.0-65.0
OPERATING INDICATION LED (Green)
REMOTE ON/OFF Optional (Requiredexternalpower source)
ISOLATION
INPUT- OUTPUT-RC
*3
AC3,000V1minute,Cutoff current=10mA,DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V1minute,Cutoff current=10mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-RC-FG
*3
AC500V1minute,Cutoff current=100mA,DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.ANDALTITUDE
-10 to +71C(Required Derating), 20 - 90%RH (Non condensing)3,000m (10,000feet)max
STORAGE TEMP.,HUMID.ANDALTITUDE
-20 to +75C,20 - 90%RH (Non condensing)9,000m (30,000feet)max
VIBRATION 10 - 55Hz,19.6m/s2(2G), 3minutes period,60minutes each alongX
,Yand Z axis
IMPACT 196.1m/s2(20G), 11ms,once eachX
,Y and Z axis
SAFETYAND
NOISE
REGULATIONS
AGENCY APPROVALS (At onlyACinput)
UL60950-1,C-UL(CSA60950-1), EN60950-1,EN50178Complieswith DEN-AN
CONDUCTEDNOISE Complies with FCC Part15 classB,VCCI-B,CISPR22-B,EN55011-B,EN55022-B
HARMONICATTENUATOR Complies with IEC61000-3-2
OTHERS CASE SIZE/WEIGHT 31X82X120mm [1.22X3.23X4.72 inches] (without terminalblock)(
WXHXD)/ 280g max (with cover : 325g max)
COOLINGMETHOD Convection
*6
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN
:RM101).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3
Applicable when Remote ON/OFF(optional) is added. RC is insulated with input, output and
FG.
*4
Derating is required.
*5
Please contact us about safety approvals for the model with option.
*6
Please contact us about class C.
*
Parallel operation with other model is not possible.
*
Derating is required when operated with cover.
*
A sound may occur from power supply at peak loading.
PBA50F
AC-DC Power Supplies Enclosed Type
PB A 50 F -5 -O
Ordering information
1 Series name
2 Single output
3 Output wattage
4 Universal input
5 Output voltage
6 Optional *5
C : with Coating
G :
Low leakage current
(0.15mA max / ACIN 240V)
E : Low leakage current
and EMI class A
(0.5mA max / ACIN 240V)
T : Vertical terminal block
J : Connector type
R :
with Remote ON/OFF
N : with Cover
(Only 24V UL508 is acquired)
N1
: with DIN rail and Cover
V :
Output voltage setting
potentiometer external-
ly
R
1 2 3 4 5 6
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
Cover is optional
Example recommended EMI/EMC filter
NAC-06-472
*
A higher current rating EMI/EMC filter
may be recommended in view of the
other devices that could be connected
in parallel with the power supply.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
PBA/PBW-9
Block diagram
FG
INRUSH
CURRENT
LIMIT
RECTIFIER
AND
FILTER
CONTROL
TRANSFORMER
CONTROL
OVER VOLTAGE
PROTECTION
DC OUT
NOISE
FILTER
RECTIFIER
AND
FILTER
INVERTER
AC IN 85 - 264V
FUSE
RECTIFIER
CURRENT
SENSING
BOOSTER
INDUCTOR
INVERTER
CONTROL
CURRENT
SENSING RC
EXTERNAL
SOURCE
E
OPTION
250V2A
External view
PBA50F
PBA50F
A
M3
2-M3
2-M3
AC(N)
AC(L)
-V
+V
35
120
1 2
(16.5)
(21.5)
(14)
(20)
(12)
82 0.5
4
(71)
77±
0.5
9.5 7.5
(11)
88±0.5 11
18
31 3.5
Point A
Terminal cover
Mounting hole
Mounting
hole
Voltage adjust
Name plate
LED
Cover (option)
CN3
Connector for Remote ON/OFF (option)
Tolerance : ±1 [±0.04]
External size of option T,J,R,N,N1 and V is different from standard model and refer to 7 Option of instruction manual for details.
Weight : 280g max (with cover : 325g max)
PCB Material/thickness : CEM3 / 1.6mm [0.06]
Chassis material : Aluminum
Dimensions in mm, [ ]= inches
Mounting torque : 0.49N m(5kgf cm)max
Screw tightening torque : M3 0.8N m(8.5kgf cm)max
FG
Please connect safety ground to the unit in 2-M3 holes.
Pin No.Contents
1
2
RC(+)
RC( -)
CN3 Option (Mfr : J.S.T.)
Connector type
Model B2B-XH-A
Mating Connector (Terminal)
XHP-2
BXH-001T-P0.6
or SXH-001T-P0.6
Barrier strip type
[0.79]
[0.65] [4.72]
[3.03]
[0.16]
[0.55]
[0.85]
[0.43]
[2.8]
[0.3][0.37]
[1.38]
[3.23] [0.02]
[0.47]
[3.46] [0.43]
[1.22]
[0.71]
[0.14]
( )
PBA/PBW-10
MODEL PBA75F-3R3 PBA75F-5 PBA75F-9 PBA75F-12 PBA75F-15 PBA75F-24 PBA75F-36 PBA75F-48
MAX OUTPUTWATTAGE[W] 49.5 75 75.6 75.6 75 76.8 75.6 76.8
DC OUTPUT 3.3V 15A 5V 15A 9V 8.4A 12V 6.3A 15V 5A 24V 3.2A 36V 2.1A 48V 1.6A
SPECIFICATIONS
MODEL PBA75F-3R3 PBA75F-5 PBA75F-9 PBA75F-12 PBA75F-15 PBA75F-24 PBA75F-36 PBA75F-48
INPUT
VOLTAGE[V] AC85 - 264 1for DC120-370 (AC50 or DC70 Please refer to the instructionmanual 2.1 Inputvoltage *4)
CURRENT[A]
ACIN 100V
0.7typ 1.0typ
ACIN 200V
0.4typ 0.5typ
FREQUENCY[Hz] 50/60 (47 -63)
EFFICIENCY[%]
ACIN 100V
77typ 81typ 80typ 81typ 82typ 83typ 84typ 84typ
ACIN 200V
78typ 83typ 82typ 83typ 84typ 85typ 86typ 86typ
POWER FACTOR(Io=100%)
ACIN 100V
0.98typ 0.99typ
ACIN 200V
0.87typ 0.93typ
INRUSH CURRENT[A]
ACIN 100V
15typ (Io=100%)(
At cold start)
ACIN 200V
30typ (Io=100%)(
At cold start)
LEAKAGE CURRENT[mA] 0.4/0.75max (ACIN 100V/240V 60Hz,Io=100%,Accordingto IEC60950-1,DENAN)
OUTPUT
VOLTAGE[V] 3.3 591215243648
CURRENT[A] 15 15 8.4 6.3 5 3.2 2.1 1.6
LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 144max 192max
LOAD REGULATION[mV] 40max 40max 100max 100max 120max 150max 240max 240max
RIPPLE[mVp-p]
0to +50C
*1
80max 80max 120max 120max 120max 120max 150max 150max
-10 -0
C
*1
140max 140max 160max 160max 160max 160max 200max 200max
RIPPLE NOISE[mVp-p]
0to +50C
*1
120max 120max 150max 150max 150max 150max 250max 250max
-10 -0
C
*1
160max 160max 180max 180max 180max 180max 300max 300max
TEMPERATURE REGULATION[mV]
0to +50C
50max 50max 90max 120max 150max 240max 360max 480max
-10to +50C
60max 60max 120max 150max 180max 290max 450max 600max
DRIFT[mV]
*2
20max 20max 36max 48max 60max 96max 144max 192max
START-UP TIME[ms] 350typ(ACIN 100V,Io=100%)
HOLD-UP TIME[ms] 20typ (ACIN 100V,Io=100%)
OUTPUTVOLTAGE ADJUSTMENT RANGE[V]
2.85-3.63 4.00 - 5.50 7.50 - 10.0 10.0-13.2 13.2 - 18.0 19.2 - 27.0 28.8 - 39.6 39.0-53.0
OUTPUTVOLTAGE SETTING[V]
3.30-3.40 5.00 - 5.15 9.00 - 9.36 12.00-12.48 15.00-15.60 24.00 - 24.96 36.00 - 37.44 48.00-49.92
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION Worksover 105% of rated current and recovers automatically
OVERVOLTAGE PROTECTION[V]
4.00-5.25 5.75 - 7.00 11.5 - 14.0 15.0-18.0 20.0 - 25.0 30.0 - 37.0 43.0 - 50.0 58.0-65.0
OPERATING INDICATION LED (Green)
REMOTE ON/OFF Optional (Requiredexternalpower source)
ISOLATION
INPUT- OUTPUT-RC
*3
AC3,000V1minute,Cutoff current=10mA,DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V1minute,Cutoff current=10mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-RC-FG
*3
AC500V1minute,Cutoff current=100mA,DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.ANDALTITUDE
-10 to +71C(Required Derating), 20 - 90%RH (Non condensing)3,000m (10,000feet)max
STORAGE TEMP.,HUMID.ANDALTITUDE
-20 to +75C,20 - 90%RH (Non condensing)9,000m (30,000feet)max
VIBRATION 10 - 55Hz,19.6m/s2(2G), 3minutes period,60minutes each alongX
,Yand Z axis
IMPACT 196.1m/s2(20G), 11ms,once eachX
,Y and Z axis
SAFETYAND
NOISE
REGULATIONS
AGENCY APPROVALS (At onlyACinput)
UL60950-1,C-UL(CSA60950-1), EN60950-1,EN50178Complieswith DEN-AN
CONDUCTEDNOISE Complies with FCC Part15 classB,VCCI-B,CISPR22-B,EN55011-B,EN55022-B
HARMONICATTENUATOR Complies with IEC61000-3-2
OTHERS CASE SIZE/WEIGHT 32X82X135mm [1.26X3.23X5.31 inches] (without terminalblock)(
WXHXD)/ 350g max (with cover : 400g max)
COOLINGMETHOD Convection
*6
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN
:RM101).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3
Applicable when Remote ON/OFF(optional) is added. RC is insulated with input, output and
FG.
*4
Derating is required.
*5
Please contact us about safety approvals for the model with option.
*6
Please contact us about class C.
*
Parallel operation with other model is not possible.
*
Derating is required when operated with cover.
*
A sound may occur from power supply at peak loading.
PBA75F
AC-DC Power Supplies Enclosed Type
PB A 75 F -5 -O
Ordering information
1 Series name
2 Single output
3 Output wattage
4 Universal input
5 Output voltage
6 Optional *5
C : with Coating
G :
Low leakage current
(0.15mA max / ACIN 240V)
E : Low leakage current
and EMI class A
(0.5mA max / ACIN 240V)
T : Vertical terminal block
J : Connector type
R :
with Remote ON/OFF
N : with Cover
(Only 24V UL508 is acquired)
N1
: with DIN rail and Cover
V :
Output voltage setting
potentiometer external-
ly
R
1 2 3 4 5 6
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
Cover is optional
Example recommended EMI/EMC filter
NAC-06-472
*
A higher current rating EMI/EMC filter
may be recommended in view of the
other devices that could be connected
in parallel with the power supply.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
PBA/PBW-11
[0.79]
[0.55]
[0.85]
[0.43]
[2.8]
[0.65] [5.31]
[3.7]
[0.16]
[0.3][0.37]
[1.38]
[3.23][0.02]
[0.47]
[4.15] [0.35]
[1.26]
[0.71]
[0.14]
Point A
A
Terminal cover
M3
Mounting hole
2-M3
Voltage adjust
AC(N)
AC(L)
-V
+V
Tolerance : ±1 [±0.04]
Weight : 350g max (with cover : 400g max)
PCB Material/thickness : CEM3 / 1.6mm [0.06]
Chassis material : Aluminum
Dimensions in mm, [ ]= inches
Mounting torque : 0.49N m(5kgf cm)max
Screw tightening torque : M3 0.8N m(8.5kgf cm)max
Name plate
32
18
9
105.5±0.5
(16.5)
4
94±0.5
35
135
(21.5)
(14)
(20)
(11)
82
(12)
(71)
9.5 7.5
PBA75F
LED
Pin No.Contents
1
2
RC(+)
RC(-)
CN3 Option (Mfr : J.S.T.)
Connector type
Model B2B-XH-A
Mating Connector (Terminal)
XHP-2
BXH-001T-P0.6
or SXH-001T-P0.6
Barrier strip type
External size of option T,J,R,N,N1 and V is different from standard model and refer to 7 Option of instruction manual for details.
0.5
3.5
CN3
Connector for Remote ON/OFF (option)
Cover (option)
FG
Please connect safety ground to the unit in 2-M3 holes.
1 2
2-M3
Mounting
hole
()
Block diagram
FG
DC OUT
AC IN 85 - 264V
RC
E
250V3.15A INRUSH
CURRENT
LIMIT
RECTIFIER
AND
FILTER
CONTROL
TRANSFORMER
CONTROL
OVER VOLTAGE
PROTECTION
NOISE
FILTER
RECTIFIER
AND
FILTER
INVERTER
FUSE
RECTIFIER
CURRENT
SENSING
BOOSTER
INDUCTOR
INVERTER
CONTROL
CURRENT
SENSING
EXTERNAL
SOURCE
OPTION
External view
PBA75F
PBA/PBW-12
MODEL
PBA100F-3R3
PBA100F-5 PBA100F-9 PBA100F-12 PBA100F-15 PBA100F-24 PBA100F-36 PBA100F-48
MAX OUTPUTWATTAGE[W] 66 100 94.5 102 105 108 100.8 100.8
DC OUTPUT 3.3V 20A 5V 20A 9V 10.5A 12V 8.5A 15V 7A 24V 4.5A 36V 2.8A 48V 2.1A
SPECIFICATIONS
MODEL
PBA100F-3R3
PBA100F-5 PBA100F-9 PBA100F-12 PBA100F-15 PBA100F-24 PBA100F-36 PBA100F-48
INPUT
VOLTAGE[V] AC85 - 264 1for DC120-370 (AC50 or DC70 Please refer to the instructionmanual 2.1 Inputvoltage *4)
CURRENT[A]
ACIN 100V
0.9typ 1.3typ
ACIN 200V
0.5typ 0.7typ
FREQUENCY[Hz] 50/60 (47 -63)
EFFICIENCY[%]
ACIN 100V
77typ 82typ 80typ 81typ 83typ 84typ 84typ 84typ
ACIN 200V
79typ 84typ 82typ 83typ 86typ 86typ 86typ 86typ
POWER FACTOR(Io=100%)
ACIN 100V
0.98typ 0.99typ
ACIN 200V
0.87typ 0.93typ
INRUSH CURRENT[A]
ACIN 100V
20typ (Io=100%)(
At cold start)
ACIN 200V
40typ (Io=100%)(
At cold start)
LEAKAGE CURRENT[mA] 0.4/0.75max (ACIN 100V/240V 60Hz,Io=100%,Accordingto IEC60950-1,DENAN)
OUTPUT
VOLTAGE[V] 3.3 591215243648
CURRENT[A] 20 20 10.5 8.5 7 4.5 2.8 2.1
LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 144max 192max
LOAD REGULATION[mV] 40max 40max 100max 100max 120max 150max 240max 240max
RIPPLE[mVp-p]
0to +50C
*1
80max 80max 120max 120max 120max 120max 150max 150max
-10 -0
C
*1
140max 140max 160max 160max 160max 160max 200max 200max
RIPPLE NOISE[mVp-p]
0to +50C
*1
120max 120max 150max 150max 150max 150max 250max 250max
-10 -0
C
*1
160max 160max 180max 180max 180max 180max 300max 300max
TEMPERATURE REGULATION[mV]
0to +50C
50max 50max 90max 120max 150max 240max 360max 480max
-10to +50C
60max 60max 120max 150max 180max 290max 450max 600max
DRIFT[mV]
*2
20max 20max 36max 48max 60max 96max 144max 192max
START-UP TIME[ms] 350typ(ACIN 100V,Io=100%)
HOLD-UP TIME[ms] 20typ (ACIN 100V,Io=100%)
OUTPUTVOLTAGE ADJUSTMENT RANGE[V]
2.85-3.63 4.00 - 5.50 7.50 - 10.0 10.0-13.2 13.2 - 18.0 19.2 - 27.0 28.8 - 39.6 39.0-53.0
OUTPUTVOLTAGE SETTING[V]
3.20-3.40 5.00 - 5.15 9.00 - 9.36 12.00-12.48 15.00-15.60 24.00 - 24.96 36.00 - 37.44 48.00-49.92
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION Worksover 105% of rated current and recovers automatically
OVERVOLTAGE PROTECTION[V]
4.00-5.25 5.75 - 7.00 11.5 - 14.0 15.0-18.0 20.0 - 25.0 30.0 - 37.0 43.0 - 50.0 58.0-65.0
OPERATING INDICATION LED (Green)
REMOTE SENSING Optional (Only -3R3,-5 Option-K)
REMOTE ON/OFF Optional (Requiredexternalpower source)
ISOLATION
INPUT- OUTPUT-RC
*3
AC3,000V1minute,Cutoff current=10mA,DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V1minute,Cutoff current=10mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-RC-FG
*3
AC500V1minute,Cutoff current=100mA,DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.ANDALTITUDE
-10 to +71C(Required Derating), 20 - 90%RH (Non condensing)3,000m (10,000feet)max
STORAGE TEMP.,HUMID.ANDALTITUDE
-20 to +75C,20 - 90%RH (Non condensing)9,000m (30,000feet)max
VIBRATION 10 - 55Hz,19.6m/s2(2G), 3minutes period,60minutes each alongX
,Yand Z axis
IMPACT 196.1m/s2(20G), 11ms,once eachX
,Y and Z axis
SAFETYAND
NOISE
REGULATIONS
AGENCY APPROVALS (At onlyACinput)
UL60950-1,C-UL(CSA60950-1), EN60950-1,EN50178Complieswith DEN-AN
CONDUCTEDNOISE Complies with FCC Part15 classB,VCCI-B,CISPR22-B,EN55011-B,EN55022-B
HARMONICATTENUATOR Complies with IEC61000-3-2
OTHERS CASE SIZE/WEIGHT 32X93X147mm [1.26X3.66X5.79 inches] (without terminalblock)(
WXHXD)/ 440gmax (with cover : 500g max)
COOLINGMETHOD Convection
*6
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN
:RM101).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3
Applicable when Remote ON/OFF(optional) is added. RC is insulated with input, output and
FG.
*4
Derating is required.
*5
Please contact us about safety approvals for the model with option.
*6
Please contact us about class C.
*
Parallel operation with other model is not possible.
*
Derating is required when operated with cover.
*
A sound may occur from power supply at peak loading.
PBA100F
AC-DC Power Supplies Enclosed Type
PB A 100 F -5 -O
Ordering information
1 Series name
2 Single output
3 Output wattage
4 Universal input
5 Output voltage
6 Optional *5
C : with Coating
G :
Low leakage current
(0.15mA max / ACIN 240V)
E : Low leakage current
and EMI class A
(0.5mA max / ACIN 240V)
T : Vertical terminal block
J : Connector type
(Only -12,-15,-24,-36,-48)
R : with Remote ON/OFF
N : with Cover
(Only 24V UL508 is acquired)
N1
: with DIN rail and Cover
V :
Output voltage setting
potentiometer external-
ly
R
1 2 3 4 5 6
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
Cover is optional
Example recommended EMI/EMC filter
NAC-06-472
*
A higher current rating EMI/EMC filter
may be recommended in view of the
other devices that could be connected
in parallel with the power supply.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
PBA/PBW-13
A
3-M3
2-M3
M4
AC(N)
AC(L)
-V
-V
+V
+V
Name plate
32
13±0.5
9.5
15
112.5 ±0.5
(13.5)
124±0.5
33.5
4
(11)
(20)
(81)
(23.5)
(14)
93
(10)
147
8.6
10
18
PBA100F
Tolerance : ±1 [±0.04]
Weight : 440g max (with cover : 500g max)
PCB Material/thickness : CEM3 / 1.6mm [0.06]
Chassis material : Aluminum
Dimensions in mm, [ ]= inches
Mounting torque : 0.49N m(5kgf cm)max
Mounting torque : M4:1.6N m(16.9kgf cm)max
Point A
Terminal cover
Mounting hole
Mounting
hole
Voltage adjust LED
External size of option T,J,R,N,N1,V and K is different from standard model and refer to 7 Option of instruction manual for details.
0.53.5
CN4
Connector for Remote sensing (option : only -3R3, -5)
CN3
Connector for Remote ON/OFF (option)
Cover (option)
FG(
)
Please connect safety ground to FG terminal on the unit.
1 2
Pin No.Contents
1
2
RC(+)
RC(-)
CN3 Option (Mfr : J.S.T.)
Connector type
Model B2B-XH-A
Mating Connector (Terminal)
XHP-2
BXH-001T-P0.6
or SXH-001T-P0.6
Barrier strip type
[0.79]
[0.55]
[0.93]
[0.43]
[3.19]
[0.53] [5.79]
[4.88]
[0.16]
[0.34][0.39]
[1.32]
[3.66] [0.02]
[0.39]
[0.71]
[4.43] [0.59]
[1.26]
[0.51][0.37]
[0.14]
()
Block diagram
FG
DC OUT
AC IN 85 - 264V
RC
E
250V3.15A INRUSH
CURRENT
LIMIT
RECTIFIER
AND
FILTER
CONTROL
TRANSFORMER
CONTROL
OVER VOLTAGE
PROTECTION
NOISE
FILTER
RECTIFIER
AND
FILTER
INVERTER
FUSE
RECTIFIER
CURRENT
SENSING
BOOSTER
INDUCTOR
INVERTER
CONTROL
CURRENT
SENSING
EXTERNAL
SOURCE
OPTION
External view
PBA100F
PBA/PBW-14
MODEL
PBA150F-3R3
PBA150F-5 PBA150F-9 PBA150F-12 PBA150F-15 PBA150F-24 PBA150F-36 PBA150F-48
MAX OUTPUTWATTAGE[W] 99 150 150.3 156 150 156 154.8 158.4
DC OUTPUT 3.3V 30A 5V 30A 9V 16.7A 12V 13A 15V 10A 24V 6.5A 36V 4.3A 48V 3.3A
SPECIFICATIONS
MODEL
PBA150F-3R3
PBA150F-5 PBA150F-9 PBA150F-12 PBA150F-15 PBA150F-24 PBA150F-36 PBA150F-48
INPUT
VOLTAGE[V] AC85 - 264 1for DC120-370 (AC50 or DC70 Please refer to the instructionmanual 2.1 Inputvoltage *4)
CURRENT[A]
ACIN 100V
1.3typ 2.0typ
ACIN 200V
0.7typ 1.0typ
FREQUENCY[Hz] 50/60 (47 -63)
EFFICIENCY[%]
ACIN 100V
80typ 83typ 82typ 83typ 84typ 85typ 85typ 85typ
ACIN 200V
82typ 86typ 85typ 86typ 87typ 88typ 88typ 88typ
POWER FACTOR(Io=100%)
ACIN 100V
0.98typ 0.99typ
ACIN 200V
0.87typ 0.93typ
INRUSH CURRENT[A]
ACIN 100V
20typ (Io=100%)(
At cold start)
ACIN 200V
40typ (Io=100%)(
At cold start)
LEAKAGE CURRENT[mA] 0.4/0.75max (ACIN 100V/240V 60Hz,Io=100%,Accordingto IEC60950-1,DENAN)
OUTPUT
VOLTAGE[V] 3.3 591215243648
CURRENT[A] 30 30 16.7 13 10 6.5 4.3 3.3
LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 144max 192max
LOAD REGULATION[mV] 40max 40max 100max 100max 120max 150max 240max 240max
RIPPLE[mVp-p]
0to +50C
*1
80max 80max 120max 120max 120max 120max 150max 150max
-10 -0
C
*1
140max 140max 160max 160max 160max 160max 200max 200max
RIPPLE NOISE[mVp-p]
0to +50C
*1
120max 120max 150max 150max 150max 150max 250max 250max
-10 -0
C
*1
160max 160max 180max 180max 180max 180max 300max 300max
TEMPERATURE REGULATION[mV]
0to +50C
50max 50max 90max 120max 150max 240max 360max 480max
-10to +50C
60max 60max 120max 150max 180max 290max 450max 600max
DRIFT[mV]
*2
20max 20max 36max 48max 60max 96max 144max 192max
START-UP TIME[ms] 350typ(ACIN 100V,Io=100%)
HOLD-UP TIME[ms] 20typ (ACIN 100V,Io=100%)
OUTPUTVOLTAGE ADJUSTMENT RANGE[V]
2.85-3.63 4.00 - 5.50 7.50 - 10.0 10.0-13.2 13.2 - 18.0 19.2 - 27.0 28.8 - 39.6 39.0-53.0
OUTPUTVOLTAGE SETTING[V]
3.30-3.40 5.00 - 5.15 9.00 - 9.36 12.00-12.48 15.00-15.60 24.00 - 24.96 36.00 - 37.44 48.00-49.92
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION Worksover 105% of rated current and recovers automatically
OVERVOLTAGE PROTECTION[V]
4.00-5.25 5.75 - 7.00 11.5 - 14.0 15.0-18.0 20.0 - 25.0 30.0 - 37.0 43.0 - 50.0 58.0-65.0
OPERATING INDICATION LED (Green)
REMOTE SENSING Optional (Only -3R3,-5 Option-K)
REMOTE ON/OFF Optional (Requiredexternalpower source)
ISOLATION
INPUT- OUTPUT-RC
*3
AC3,000V1minute,Cutoff current=10mA,DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V1minute,Cutoff current=10mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-RC-FG
*3
AC500V1minute,Cutoff current=100mA,DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.ANDALTITUDE
-10 to +71C(Required Derating), 20 - 90%RH (Non condensing)3,000m (10,000feet)max
STORAGE TEMP.,HUMID.ANDALTITUDE
-20 to +75C,20 - 90%RH (Non condensing)9,000m (30,000feet)max
VIBRATION 10 - 55Hz,19.6m/s2(2G), 3minutes period,60minutes each alongX
,Yand Z axis
IMPACT 196.1m/s2(20G), 11ms,once eachX
,Y and Z axis
SAFETYAND
NOISE
REGULATIONS
AGENCY APPROVALS (At onlyACinput)
UL60950-1,C-UL(CSA60950-1), EN60950-1,EN50178Complieswith DEN-AN
CONDUCTEDNOISE Complies with FCC Part15 classB,VCCI-B,CISPR22-B,EN55011-B,EN55022-B
HARMONICATTENUATOR Complies with IEC61000-3-2
OTHERS CASE SIZE/WEIGHT 34X93X168mm [1.34X3.66X6.61 inches] (without terminalblock)(
WXHXD)/ 560g max (with cover : 630g max)
COOLINGMETHOD Convection
*6
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN
:RM101).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3
Applicable when Remote ON/OFF(optional) is added. RC is insulated with input, output and
FG.
*4
Derating is required.
*5
Please contact us about safety approvals for the model with option.
*6
Please contact us about class C.
*
Parallel operation with other model is not possible.
*
Derating is required when operated with cover.
*
A sound may occur from power supply at peak loading.
PBA150F
AC-DC Power Supplies Enclosed Type
PB A 150 F -5 -O
Ordering information
1 Series name
2 Single output
3 Output wattage
4 Universal input
5 Output voltage
6 Optional *5
C : with Coating
G :
Low leakage current
(0.15mA max / ACIN 240V)
E : Low leakage current
and EMI class A
(0.5mA max / ACIN 240V)
T : Vertical terminal block
J : Connector type
(Only -12,-15,-24,-36,-48)
R : with Remote ON/OFF
N : with Cover
(Only 24V UL508 is acquired)
N1
: with DIN rail and Cover
V :
Output voltage setting
potentiometer external-
ly
R
1 2 3 4 5 6
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
Cover is optional
Example recommended EMI/EMC filter
NAC-06-472
*
A higher current rating EMI/EMC filter
may be recommended in view of the
other devices that could be connected
in parallel with the power supply.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
PBA/PBW-15
PBA150F
9
93
34
19
(13.5) 168
58.5
37.5
78±0.5 2-M3
2-M3
TB1
M4
+V
+V
-V
-V
AC(L)
AC(N)
A
139.5±0.5
10 8.6
(81)
(14.5)
(20.5)
[0.81]
[0.57]
[0.53] [6.61]
[3.07]
[5.49]
[0.35]
[2.3]
[0.94]
[3.19]
[1.48]
[0.75]
[1.34] [3.66]
[0.02]
[0.34][0.39][0.39]
[0.14]
(11.5)
[0.45]
(24)
(10)
Tolerance : ±1 [±0.04]
Weight : 560g max (with cover : 630g max)
Keep drawing current per pin below 20A for TB1.
PCB Material/thickness : CEM3 / 1.6mm [0.06]
Chassis material : Aluminum
Dimensions in mm, [ ]= inches
Mounting torque : 0.49N m(5kgf cm)max
Mounting torque : M4:1.6N m(16.9kgf cm)max
Name plate
Point A
Terminal cover
Mounting hole
Mounting
hole
Voltage adjust LED
External size of option T,J,R,N,N1,V and K is different from standard model and refer to 7 Option of instruction manual for details.
0.5
3.5
CN4
Connector for Remote sensing (option : only -3R3, -5)
CN3
Connector for Remote ON/OFF (option)
Cover
(option)
FG(
)
Please connect safety ground to FG terminal on the unit.
1 2
Pin No.Contents
1
2
RC(+)
RC(-)
CN3 Option (Mfr : J.S.T.)
Connector type
Model B2B-XH-A
Mating Connector (Terminal)
XHP-2
BXH-001T-P0.6
or SXH-001T-P0.6
Barrier strip type
()
Block diagram
FG
DC OUT
AC IN 85 - 264V
RC
E
250V4A INRUSH
CURRENT
LIMIT
RECTIFIER
AND
FILTER
CONTROL
TRANSFORMER
CONTROL
OVER VOLTAGE
PROTECTION
NOISE
FILTER
RECTIFIER
AND
FILTER
INVERTER
FUSE
RECTIFIER
CURRENT
SENSING
BOOSTER
INDUCTOR
INVERTER
CONTROL
CURRENT
SENSING
EXTERNAL
SOURCE
OPTION
External view
PBA150F