PBA/PBW-14
MODEL
PBA150F-3R3
PBA150F-5 PBA150F-9 PBA150F-12 PBA150F-15 PBA150F-24 PBA150F-36 PBA150F-48
MAX OUTPUTWATTAGE[W] 99 150 150.3 156 150 156 154.8 158.4
DC OUTPUT 3.3V 30A 5V 30A 9V 16.7A 12V 13A 15V 10A 24V 6.5A 36V 4.3A 48V 3.3A
SPECIFICATIONS
MODEL
PBA150F-3R3
PBA150F-5 PBA150F-9 PBA150F-12 PBA150F-15 PBA150F-24 PBA150F-36 PBA150F-48
INPUT
VOLTAGE[V] AC85 - 264 1for DC120-370 (AC50 or DC70 Please refer to the instructionmanual 2.1 Inputvoltage *4)
CURRENT[A]
ACIN 100V
1.3typ 2.0typ
ACIN 200V
0.7typ 1.0typ
FREQUENCY[Hz] 50/60 (47 -63)
EFFICIENCY[%]
ACIN 100V
80typ 83typ 82typ 83typ 84typ 85typ 85typ 85typ
ACIN 200V
82typ 86typ 85typ 86typ 87typ 88typ 88typ 88typ
POWER FACTOR(Io=100%)
ACIN 100V
0.98typ 0.99typ
ACIN 200V
0.87typ 0.93typ
INRUSH CURRENT[A]
ACIN 100V
20typ (Io=100%)(
At cold start)
ACIN 200V
40typ (Io=100%)(
At cold start)
LEAKAGE CURRENT[mA] 0.4/0.75max (ACIN 100V/240V 60Hz,Io=100%,Accordingto IEC60950-1,DENAN)
OUTPUT
VOLTAGE[V] 3.3 591215243648
CURRENT[A] 30 30 16.7 13 10 6.5 4.3 3.3
LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 144max 192max
LOAD REGULATION[mV] 40max 40max 100max 100max 120max 150max 240max 240max
RIPPLE[mVp-p]
0to +50C
*1
80max 80max 120max 120max 120max 120max 150max 150max
-10 -0
C
*1
140max 140max 160max 160max 160max 160max 200max 200max
RIPPLE NOISE[mVp-p]
0to +50C
*1
120max 120max 150max 150max 150max 150max 250max 250max
-10 -0
C
*1
160max 160max 180max 180max 180max 180max 300max 300max
TEMPERATURE REGULATION[mV]
0to +50C
50max 50max 90max 120max 150max 240max 360max 480max
-10to +50C
60max 60max 120max 150max 180max 290max 450max 600max
DRIFT[mV]
*2
20max 20max 36max 48max 60max 96max 144max 192max
START-UP TIME[ms] 350typ(ACIN 100V,Io=100%)
HOLD-UP TIME[ms] 20typ (ACIN 100V,Io=100%)
OUTPUTVOLTAGE ADJUSTMENT RANGE[V]
2.85-3.63 4.00 - 5.50 7.50 - 10.0 10.0-13.2 13.2 - 18.0 19.2 - 27.0 28.8 - 39.6 39.0-53.0
OUTPUTVOLTAGE SETTING[V]
3.30-3.40 5.00 - 5.15 9.00 - 9.36 12.00-12.48 15.00-15.60 24.00 - 24.96 36.00 - 37.44 48.00-49.92
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION Worksover 105% of rated current and recovers automatically
OVERVOLTAGE PROTECTION[V]
4.00-5.25 5.75 - 7.00 11.5 - 14.0 15.0-18.0 20.0 - 25.0 30.0 - 37.0 43.0 - 50.0 58.0-65.0
OPERATING INDICATION LED (Green)
REMOTE SENSING Optional (Only -3R3,-5 Option-K)
REMOTE ON/OFF Optional (Requiredexternalpower source)
ISOLATION
INPUT- OUTPUT-RC
*3
AC3,000V1minute,Cutoff current=10mA,DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V1minute,Cutoff current=10mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-RC-FG
*3
AC500V1minute,Cutoff current=100mA,DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.ANDALTITUDE
-10 to +71C(Required Derating), 20 - 90%RH (Non condensing)3,000m (10,000feet)max
STORAGE TEMP.,HUMID.ANDALTITUDE
-20 to +75C,20 - 90%RH (Non condensing)9,000m (30,000feet)max
VIBRATION 10 - 55Hz,19.6m/s2(2G), 3minutes period,60minutes each alongX
,Yand Z axis
IMPACT 196.1m/s2(20G), 11ms,once eachX
,Y and Z axis
SAFETYAND
NOISE
REGULATIONS
AGENCY APPROVALS (At onlyACinput)
UL60950-1,C-UL(CSA60950-1), EN60950-1,EN50178Complieswith DEN-AN
CONDUCTEDNOISE Complies with FCC Part15 classB,VCCI-B,CISPR22-B,EN55011-B,EN55022-B
HARMONICATTENUATOR Complies with IEC61000-3-2
OTHERS CASE SIZE/WEIGHT 34X93X168mm [1.34X3.66X6.61 inches] (without terminalblock)(
WXHXD)/ 560g max (with cover : 630g max)
COOLINGMETHOD Convection
*6
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN
:RM101).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3
Applicable when Remote ON/OFF(optional) is added. RC is insulated with input, output and
FG.
*4
Derating is required.
*5
Please contact us about safety approvals for the model with option.
*6
Please contact us about class C.
*
Parallel operation with other model is not possible.
*
Derating is required when operated with cover.
*
A sound may occur from power supply at peak loading.
PBA150F
AC-DC Power Supplies Enclosed Type
PB A 150 F -5 -O
Ordering information
1 Series name
2 Single output
3 Output wattage
4 Universal input
5 Output voltage
6 Optional *5
C : with Coating
G :
Low leakage current
(0.15mA max / ACIN 240V)
E : Low leakage current
and EMI class A
(0.5mA max / ACIN 240V)
T : Vertical terminal block
J : Connector type
(Only -12,-15,-24,-36,-48)
R : with Remote ON/OFF
N : with Cover
(Only 24V UL508 is acquired)
N1
: with DIN rail and Cover
V :
Output voltage setting
potentiometer external-
ly
1 2 3 4 5 6
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
Cover is optional
Example recommended EMI/EMC filter
NAC-06-472
*
A higher current rating EMI/EMC filter
may be recommended in view of the
other devices that could be connected
in parallel with the power supply.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.